Sérgio Candido Dias
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sérgio Candido Dias has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Aline Batista Gonçalves Franco
Faculdade São Leopoldo Mandic
7 shared publications - Geraldo Alberto Pinheiro de Carvalho
Faculdade São Leopoldo Mandic
7 shared publications - Elimario Venturin Ramos
Faculdade São Leopoldo Mandic
6 shared publications - Caio Marques Martins
Faculdade São Leopoldo Mandic
5 shared publications - Fabiano Perez
Faculdade São Leopoldo Mandic
5 shared publications - Silvio Mecca Junior
Faculdade São Leopoldo Mandic
5 shared publications
Latest Publications
- Open Access
- 19 December 2022
- Published by Instituto de Filosofia e Ciências Humanas - UNICAMP in Brazilian Journal of Oral Sciences
- Vol. 22, e239079
Use of scanning electron microscope to evaluate the marginal fit of protocol bars obtained through benchtop or intraoral digital scanners
Aim: To evaluate the marginal fit of protocol bars milled from digital models obtained by conventional molding followed by bench scanning or digital molding with an intraoral scanner. Methods: Four morse-cone implants and the mini-pillars were installed in a 3D printed mandible model (master model). Digital models of the master model were obtained by (n=10): (Group A - Conventional) conventional (analog) molding of the master model followed by bench scanning or (Group B - Digital) molding of the master model with an intraoral scanner. All-on-four protocol bars were designed and milled from the digital models for both groups and screwed into the master model. Scanning electron microscopy (SEM) images from the distal, central, and mesial regions of each implant were obtained and the implant-protocol bar marginal fit was measured in an image software (Image J). The mean misfit of each region was analyzed by two-factor ANOVA, Tukey test, and Student’s t-test (0,05 = 0.05). Results: The digital approach (B) showed higher misadaptation than the conventional approach (A, p < 0.05), regardless of the region evaluated. In group A, the central region showed higher maladjustment than the mesial region (p0.05). Conclusion: The conventional method of acquiring digital models using the bench scanner produced bars for the All-On-Four protocol with better marginal fit than the digital models obtained with an intraoral scanner.
- 19 December 2022
- Published by Instituto de Filosofia e Ciências Humanas - UNICAMP in Brazilian Journal of Oral Sciences
- Vol. 22, e239079
Open AccessUse of scanning electron microscope to evaluate the marginal fit of protocol bars obtained through benchtop or intraoral digital scanners
Aim: To evaluate the marginal fit of protocol bars milled from digital models obtained by conventional molding followed by bench scanning or digital molding with an intraoral scanner. Methods: Four morse-cone implants and the mini-pillars were installed in a 3D printed mandible model (master model). Digital models of the master model were obtained by (n=10): (Group A - Conventional) conventional (analog) molding of the master model followed by bench scanning or (Group B - Digital) molding of the master model with an intraoral scanner. All-on-four protocol bars were designed and milled from the digital models for both groups and screwed into the master model. Scanning electron microscopy (SEM) images from the distal, central, and mesial regions of each implant were obtained and the implant-protocol bar marginal fit was measured in an image software (Image J). The mean misfit of each region was analyzed by two-factor ANOVA, Tukey test, and Student’s t-test (0,05 = 0.05). Results: The digital approach (B) showed higher misadaptation than the conventional approach (A, p < 0.05), regardless of the region evaluated. In group A, the central region showed higher maladjustment than the mesial region (p0.05). Conclusion: The conventional method of acquiring digital models using the bench scanner produced bars for the All-On-Four protocol with better marginal fit than the digital models obtained with an intraoral scanner.
- Open Access
- 13 May 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (7)
Flexural strength of milled polymer bars, with and without glass fiber reinforcement
The aim of this study is to test and compare the flexural strength of milled polymer bars, with and without glass fiber reinforcement. The number of samples in the study was defined through a pilot study on a universal testing machine (EMIC) (n = 5). The brands analyzed in this study were Arch Free Metal, Zantex, Bioplas and PEEK. All samples were submitted to thermal aging before the three-point flexural test. Fracture patterns were analyzed using a Scanning Electron Microscope. Results show that the Arch Free Metal bar presented the largest flexural strength, followed by Zantex and PEEK bars, that lacked statistical difference, and Bioplas bars. Regarding fracture patterns, Arch Free Metal and Zantex bars were partially fractured and showed partial glass fiber rupture; PEEK bars were not fractured and showed plastic behavior; and Bioplas bars were fractured. It is possible to conclude that the reinforced polymer bar Arch Free Metal has a better performance in terms of flexural strength than the other tested materials.
- 13 May 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (7)
Open AccessFlexural strength of milled polymer bars, with and without glass fiber reinforcement
The aim of this study is to test and compare the flexural strength of milled polymer bars, with and without glass fiber reinforcement. The number of samples in the study was defined through a pilot study on a universal testing machine (EMIC) (n = 5). The brands analyzed in this study were Arch Free Metal, Zantex, Bioplas and PEEK. All samples were submitted to thermal aging before the three-point flexural test. Fracture patterns were analyzed using a Scanning Electron Microscope. Results show that the Arch Free Metal bar presented the largest flexural strength, followed by Zantex and PEEK bars, that lacked statistical difference, and Bioplas bars. Regarding fracture patterns, Arch Free Metal and Zantex bars were partially fractured and showed partial glass fiber rupture; PEEK bars were not fractured and showed plastic behavior; and Bioplas bars were fractured. It is possible to conclude that the reinforced polymer bar Arch Free Metal has a better performance in terms of flexural strength than the other tested materials.
- Open Access
- 17 April 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (6)
Influence of different surface treatments on the shear strength between acrylic resin and two materials: Polyether Ether Ketone (PEEK) / ZANTEXR
The present study assesses the shear strength of Polyether Ether Ketone (PEEK) and Zantex to thermopolymerizable acrylic resin (TAR) with different surface treatments. To this end, 100 test specimens were produced and divided into two groups: G1(PEEK + TAR) and G2 (Zantex + TAR). Each group was subdivided into the subgroups A, B, C, D and E (n=10) according to surface pre-treatment: A: TAR + PEEK/Zantex without surface treatment (control); B: TAR + PEEK/Zantex treated with Palabond; C: TAR + PEEK/Zantex blasted with aluminum oxide (Al2O3) of 125 µm; D: TAR + PEEK /Zantex treated with Al2O3 of 125 µm + Palabond; and E: TAR + PEEK/Zantex prepared with groove-shaped retentions. The structures were tested in a Universal testing machine EMIC DL2000. Two-way variance analysis showed significant difference between materials and surface treatments (p < 0.001). Multiple comparisons were done with Tukey’s test and failure modes were analyzed with the G test. Statistical analysis showed that Zantex outperformed PEEK for most treatments and showed similar performance in the subgroups treated with Al2O3. Within the PEEK group, the use of grooves and Palabond combined with blasting showed the best results; in the Zantex group, the best results were obtained with Palabond and Palabond combined with blasting. Regarding failure modes, PEEK showed only adhesive failures and Zantex’s failures were dependent on treatment. Therefore, the surface treatment method applied to the polymers studied here contribute to the material’s adhesion to acrylic resin.
- 17 April 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (6)
Open AccessInfluence of different surface treatments on the shear strength between acrylic resin and two materials: Polyether Ether Ketone (PEEK) / ZANTEXR
The present study assesses the shear strength of Polyether Ether Ketone (PEEK) and Zantex to thermopolymerizable acrylic resin (TAR) with different surface treatments. To this end, 100 test specimens were produced and divided into two groups: G1(PEEK + TAR) and G2 (Zantex + TAR). Each group was subdivided into the subgroups A, B, C, D and E (n=10) according to surface pre-treatment: A: TAR + PEEK/Zantex without surface treatment (control); B: TAR + PEEK/Zantex treated with Palabond; C: TAR + PEEK/Zantex blasted with aluminum oxide (Al2O3) of 125 µm; D: TAR + PEEK /Zantex treated with Al2O3 of 125 µm + Palabond; and E: TAR + PEEK/Zantex prepared with groove-shaped retentions. The structures were tested in a Universal testing machine EMIC DL2000. Two-way variance analysis showed significant difference between materials and surface treatments (p < 0.001). Multiple comparisons were done with Tukey’s test and failure modes were analyzed with the G test. Statistical analysis showed that Zantex outperformed PEEK for most treatments and showed similar performance in the subgroups treated with Al2O3. Within the PEEK group, the use of grooves and Palabond combined with blasting showed the best results; in the Zantex group, the best results were obtained with Palabond and Palabond combined with blasting. Regarding failure modes, PEEK showed only adhesive failures and Zantex’s failures were dependent on treatment. Therefore, the surface treatment method applied to the polymers studied here contribute to the material’s adhesion to acrylic resin.
- Open Access
- 9 March 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (4)
Análisis de la resistencia adhesiva de postes de fibra de vidrio sometidos al ensayo mecánico de cizallamiento por extrusión en diferentes protocolos de cementación
El objetivo fue evaluar la resistencia al cizallamiento por extrusión y verificar el tipo de falla de postes de fibra de vidrio que han recibido diferentes tratamientos de superficie, y testar el adhesivo multiuso Single Bond Universal® (3M ESPE). Métodos: Ochenta incisivos bovinos con tratamiento endodóntico fueran aleatoriamente repartidos en cuatro grupos; Grupo I: los postes recibieron aplicación de silano; Grupo II: ningún tipo de tratamiento; Grupo III: silano y adhesivo; y Grupo IV: solamente adhesivo. Los grupos fueran sometidos a ciclaje térmico por 5.000 ciclos, las raíces seccionadas y sometidas al teste push out. Resultados: Con la silanización y la aplicación del adhesivo, la resistencia entre el poste de fibra de vidrio y la dentina ha sido significativamente menor en relación solamente la silanización. La asociación silano-adhesivo causó perjuicio a la unión. Conclusiones: La silanización por si solo es que se constituyó en el tratamiento que mejoró la resistencia unión. Fallas adhesivas fueran las más prevalentes.
- 9 March 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (4)
Open AccessAnálisis de la resistencia adhesiva de postes de fibra de vidrio sometidos al ensayo mecánico de cizallamiento por extrusión en diferentes protocolos de cementación
El objetivo fue evaluar la resistencia al cizallamiento por extrusión y verificar el tipo de falla de postes de fibra de vidrio que han recibido diferentes tratamientos de superficie, y testar el adhesivo multiuso Single Bond Universal® (3M ESPE). Métodos: Ochenta incisivos bovinos con tratamiento endodóntico fueran aleatoriamente repartidos en cuatro grupos; Grupo I: los postes recibieron aplicación de silano; Grupo II: ningún tipo de tratamiento; Grupo III: silano y adhesivo; y Grupo IV: solamente adhesivo. Los grupos fueran sometidos a ciclaje térmico por 5.000 ciclos, las raíces seccionadas y sometidas al teste push out. Resultados: Con la silanización y la aplicación del adhesivo, la resistencia entre el poste de fibra de vidrio y la dentina ha sido significativamente menor en relación solamente la silanización. La asociación silano-adhesivo causó perjuicio a la unión. Conclusiones: La silanización por si solo es que se constituyó en el tratamiento que mejoró la resistencia unión. Fallas adhesivas fueran las más prevalentes.
- Open Access
- 9 March 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (4)
Influence of surface treatment on the shear strength of Ultra Translucent Multi Layered Zirconia Katana
The aim of this study is to assess how shear strength of Ultra Translucent Multi Layered Zirconia Katana (UTML) is affected by the conditioning with 10% hydrofluoric acid combined with the current surface treatment protocol: air, primer containing 10-MDP, and cement. Samples of UTML Zirconia Katana were machined to measure 5x5x10 units of measurement, attached, and divided into two groups. In the control group, samples were treated with 27 um aluminum oxide blasting at 4 bars, application of Zr primer containing 10-MDP and, finally, cement Panávia V5. In the experimental group, samples were also treated with 10% hydrofluoric acid following blasting and prior to the primer application. The test specimens were submitted to shear mechanical strength test on a universal testing machine EMIC DL2000 (EMIC, São Paulo, Brazil), surface analysis with Scanning Electron Microscope (SEM) (Sputter Coaster Emitech, K450) and surface roughness. Results showed that the bond strength of specimens conditioned with acid was 41% higher (p = 0.031). Student’s t test showed that the samples conditioned with acid were rougher than those without conditioning (p = 0.045). Microscopic analysis showed surface alterations on samples conditioned with acid. It is possible to conclude that the group conditioned with hydrofluoric acid showed better adhesive behavior.
- 9 March 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (4)
Open AccessInfluence of surface treatment on the shear strength of Ultra Translucent Multi Layered Zirconia Katana
The aim of this study is to assess how shear strength of Ultra Translucent Multi Layered Zirconia Katana (UTML) is affected by the conditioning with 10% hydrofluoric acid combined with the current surface treatment protocol: air, primer containing 10-MDP, and cement. Samples of UTML Zirconia Katana were machined to measure 5x5x10 units of measurement, attached, and divided into two groups. In the control group, samples were treated with 27 um aluminum oxide blasting at 4 bars, application of Zr primer containing 10-MDP and, finally, cement Panávia V5. In the experimental group, samples were also treated with 10% hydrofluoric acid following blasting and prior to the primer application. The test specimens were submitted to shear mechanical strength test on a universal testing machine EMIC DL2000 (EMIC, São Paulo, Brazil), surface analysis with Scanning Electron Microscope (SEM) (Sputter Coaster Emitech, K450) and surface roughness. Results showed that the bond strength of specimens conditioned with acid was 41% higher (p = 0.031). Student’s t test showed that the samples conditioned with acid were rougher than those without conditioning (p = 0.045). Microscopic analysis showed surface alterations on samples conditioned with acid. It is possible to conclude that the group conditioned with hydrofluoric acid showed better adhesive behavior.
- Open Access
- 6 February 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (3)
Shear bond strength of resinous cements to Zirconia Katana™ UTML
The aim of this study is to assess the bond strength of three resinous cements to Zirconia Katana™ UTML (Kuraray Noritake Dental Inc, Miyoshi, Aichi, Japan). Thirty-six blocks of Zirconia were milled and included in polyvynil chloride (PVC) pipes with self-polymerizable acrylic resin. Each sample was polished in a polishing machine, blasted with aluminum particles, cleaned with ultrasound, and dried with compressed air. The cementation was done according to the protocol recommended by the manufacturer. The samples were divided in 3 groups (n=12) according to the resinous cement used: Group R - RelyX™ U200 Automix (3M ESPE, Sumaré, São Paulo, Brazil); Group M - Multilink® N (Ivoclar Vivadent, Schaan, Liechtenstein); and Group P - Panavia™ V5 Paste (Kuraray Noritake Dental Inc, Cotia, São Paulo, Brazil). The shear stress test was performed in EMIC DL2000 (EMIC, São Paulo, SP, Brazil), and failure type was analyzed. Average bond strengths were 5.4 kgf, 5.8 kgf, and 6.68 kgf for groups R1, M1 and P1, respectively. Variance analysis showed no significant difference between groups. None of the groups showed cohesive failure; there was no significant difference in the frequency of mixed and adhesive failure between groups. All three cements showed similar performance in the tests.
- 6 February 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (3)
Open AccessShear bond strength of resinous cements to Zirconia Katana™ UTML
The aim of this study is to assess the bond strength of three resinous cements to Zirconia Katana™ UTML (Kuraray Noritake Dental Inc, Miyoshi, Aichi, Japan). Thirty-six blocks of Zirconia were milled and included in polyvynil chloride (PVC) pipes with self-polymerizable acrylic resin. Each sample was polished in a polishing machine, blasted with aluminum particles, cleaned with ultrasound, and dried with compressed air. The cementation was done according to the protocol recommended by the manufacturer. The samples were divided in 3 groups (n=12) according to the resinous cement used: Group R - RelyX™ U200 Automix (3M ESPE, Sumaré, São Paulo, Brazil); Group M - Multilink® N (Ivoclar Vivadent, Schaan, Liechtenstein); and Group P - Panavia™ V5 Paste (Kuraray Noritake Dental Inc, Cotia, São Paulo, Brazil). The shear stress test was performed in EMIC DL2000 (EMIC, São Paulo, SP, Brazil), and failure type was analyzed. Average bond strengths were 5.4 kgf, 5.8 kgf, and 6.68 kgf for groups R1, M1 and P1, respectively. Variance analysis showed no significant difference between groups. None of the groups showed cohesive failure; there was no significant difference in the frequency of mixed and adhesive failure between groups. All three cements showed similar performance in the tests.
- Open Access
- 6 February 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (3)
Analysis of compressive strength of occlusal splints manufactured with three liquid resins at three angles of orientation on 3D printer
The aim of this study is to analyze the compressive strength of occlusal splints manufactured with three different liquid resins in a 3D printer and in three angles of orientation. The resins used here are (n=12): Resilab Clear (Wilcos do Brasil, Petrópolis, RJ, Brazil), Prizma Smart Print Bio (Makertech Labs, Tatuí, SP, Brazil), and Cosmos Splint (Yller Biomateriais, Pelotas, RS, Brazil); each resin group are divided into three subgroups according to orientation of manufacture: 0, 45 and 90 degrees. A dental manikin was scanned and the file was used to manufacture a steel hemiarch model. This model was used to design the occlusal splints and as a basis for the tests. The splints were designed with flat occlusal surface and minimum thickness of 2 mm. The compressive test was performed with constant force of 200N, velocity of 0.5 mm/min, along the entire occlusal surface until fracture. Results show no difference between the resins, regardless of orientation of manufacture. The orientation showed no intragroup effect for resins Prizma Smart Print Bio and Resilab Clear; the resin Cosmos showed larger compressive strength for the samples manufactured at 45 degrees than at 0 degree. The 90-degree samples were intermediary and showed no difference from other angles. This study shows that the three resins had similar behavior in terms of compressive strength, except for the intragroup effect of orientation of Cosmos Splint resin, where plates manufactured at 0 degree performed worse than those at 45 degrees.
- 6 February 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (3)
Open AccessAnalysis of compressive strength of occlusal splints manufactured with three liquid resins at three angles of orientation on 3D printer
The aim of this study is to analyze the compressive strength of occlusal splints manufactured with three different liquid resins in a 3D printer and in three angles of orientation. The resins used here are (n=12): Resilab Clear (Wilcos do Brasil, Petrópolis, RJ, Brazil), Prizma Smart Print Bio (Makertech Labs, Tatuí, SP, Brazil), and Cosmos Splint (Yller Biomateriais, Pelotas, RS, Brazil); each resin group are divided into three subgroups according to orientation of manufacture: 0, 45 and 90 degrees. A dental manikin was scanned and the file was used to manufacture a steel hemiarch model. This model was used to design the occlusal splints and as a basis for the tests. The splints were designed with flat occlusal surface and minimum thickness of 2 mm. The compressive test was performed with constant force of 200N, velocity of 0.5 mm/min, along the entire occlusal surface until fracture. Results show no difference between the resins, regardless of orientation of manufacture. The orientation showed no intragroup effect for resins Prizma Smart Print Bio and Resilab Clear; the resin Cosmos showed larger compressive strength for the samples manufactured at 45 degrees than at 0 degree. The 90-degree samples were intermediary and showed no difference from other angles. This study shows that the three resins had similar behavior in terms of compressive strength, except for the intragroup effect of orientation of Cosmos Splint resin, where plates manufactured at 0 degree performed worse than those at 45 degrees.
- Open Access
- 2 March 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (3)
Shear bond strength between resin cement and lithium disilicate ceramics after intrinsic staining
Shear bond strength between resin cement and lithium disilicate ceramics after different etching protocols, different heat treatments, and intrinsic staining was tested. Lithium disilicate specimens were 10 mm long by 5 mm wide by 2 mm thick and were divided into 5 groups (n=10): Group 1: specimens heated to 840 ºC; Group 2: specimens submitted to double heating treatment (heated to 840 ºC, cooled down, heated to 770 ºC); Group 3: specimens heated to 840 ºC, cooled down, intrinsically stained, heated to 770 ºC; Group 4: specimens heated to 840 ºC, cooled down, heated to 800 ºC; Group 5: specimens heated to 840 ºC, cooled down, intrinsically stained, heated to 800 ºC. Groups 1, 3, and 5 were etched with 10% hydrofluoric acid (HF) and analyzed by scanning electron microscopy (SEM) at 10,000´. Specimens from groups 2 and 4 were not etched with HF. Energy dispersive spectrometry (EDS) and SEM analyzed specimen staining physicochemical changes in groups 3 and 5. The resin cement samples were 1-mm in diameter and 2-mm in height. Analysis of variance and independent t test were used to compare the groups in the study (p0.05). Shear bond strength between resin cement and lithium disilicate ceramics was not influenced by intrinsic staining. Topography of the ceramic material changed with different heating temperatures and with acid etching.
- 2 March 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (3)
Open AccessShear bond strength between resin cement and lithium disilicate ceramics after intrinsic staining
Shear bond strength between resin cement and lithium disilicate ceramics after different etching protocols, different heat treatments, and intrinsic staining was tested. Lithium disilicate specimens were 10 mm long by 5 mm wide by 2 mm thick and were divided into 5 groups (n=10): Group 1: specimens heated to 840 ºC; Group 2: specimens submitted to double heating treatment (heated to 840 ºC, cooled down, heated to 770 ºC); Group 3: specimens heated to 840 ºC, cooled down, intrinsically stained, heated to 770 ºC; Group 4: specimens heated to 840 ºC, cooled down, heated to 800 ºC; Group 5: specimens heated to 840 ºC, cooled down, intrinsically stained, heated to 800 ºC. Groups 1, 3, and 5 were etched with 10% hydrofluoric acid (HF) and analyzed by scanning electron microscopy (SEM) at 10,000´. Specimens from groups 2 and 4 were not etched with HF. Energy dispersive spectrometry (EDS) and SEM analyzed specimen staining physicochemical changes in groups 3 and 5. The resin cement samples were 1-mm in diameter and 2-mm in height. Analysis of variance and independent t test were used to compare the groups in the study (p0.05). Shear bond strength between resin cement and lithium disilicate ceramics was not influenced by intrinsic staining. Topography of the ceramic material changed with different heating temperatures and with acid etching.