Aline Batista Gonçalves Franco
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Aline Batista Gonçalves Franco has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Geraldo Alberto Pinheiro de Carvalho
Faculdade São Leopoldo Mandic
8 shared publications - Sérgio Candido Dias
Faculdade São Leopoldo Mandic
7 shared publications - Amanda Gonçalves Franco
University of Itaúna
6 shared publications - Elimario Venturin Ramos
Faculdade São Leopoldo Mandic
6 shared publications - Caio Marques Martins
Faculdade São Leopoldo Mandic
5 shared publications - Fabiano Perez
Faculdade São Leopoldo Mandic
5 shared publications
Latest Publications
- Open Access
- 19 December 2022
- Published by Instituto de Filosofia e Ciências Humanas - UNICAMP in Brazilian Journal of Oral Sciences
- Vol. 22, e239079
Use of scanning electron microscope to evaluate the marginal fit of protocol bars obtained through benchtop or intraoral digital scanners
Aim: To evaluate the marginal fit of protocol bars milled from digital models obtained by conventional molding followed by bench scanning or digital molding with an intraoral scanner. Methods: Four morse-cone implants and the mini-pillars were installed in a 3D printed mandible model (master model). Digital models of the master model were obtained by (n=10): (Group A - Conventional) conventional (analog) molding of the master model followed by bench scanning or (Group B - Digital) molding of the master model with an intraoral scanner. All-on-four protocol bars were designed and milled from the digital models for both groups and screwed into the master model. Scanning electron microscopy (SEM) images from the distal, central, and mesial regions of each implant were obtained and the implant-protocol bar marginal fit was measured in an image software (Image J). The mean misfit of each region was analyzed by two-factor ANOVA, Tukey test, and Student’s t-test (0,05 = 0.05). Results: The digital approach (B) showed higher misadaptation than the conventional approach (A, p < 0.05), regardless of the region evaluated. In group A, the central region showed higher maladjustment than the mesial region (p0.05). Conclusion: The conventional method of acquiring digital models using the bench scanner produced bars for the All-On-Four protocol with better marginal fit than the digital models obtained with an intraoral scanner.
- 19 December 2022
- Published by Instituto de Filosofia e Ciências Humanas - UNICAMP in Brazilian Journal of Oral Sciences
- Vol. 22, e239079
Open AccessUse of scanning electron microscope to evaluate the marginal fit of protocol bars obtained through benchtop or intraoral digital scanners
Aim: To evaluate the marginal fit of protocol bars milled from digital models obtained by conventional molding followed by bench scanning or digital molding with an intraoral scanner. Methods: Four morse-cone implants and the mini-pillars were installed in a 3D printed mandible model (master model). Digital models of the master model were obtained by (n=10): (Group A - Conventional) conventional (analog) molding of the master model followed by bench scanning or (Group B - Digital) molding of the master model with an intraoral scanner. All-on-four protocol bars were designed and milled from the digital models for both groups and screwed into the master model. Scanning electron microscopy (SEM) images from the distal, central, and mesial regions of each implant were obtained and the implant-protocol bar marginal fit was measured in an image software (Image J). The mean misfit of each region was analyzed by two-factor ANOVA, Tukey test, and Student’s t-test (0,05 = 0.05). Results: The digital approach (B) showed higher misadaptation than the conventional approach (A, p < 0.05), regardless of the region evaluated. In group A, the central region showed higher maladjustment than the mesial region (p0.05). Conclusion: The conventional method of acquiring digital models using the bench scanner produced bars for the All-On-Four protocol with better marginal fit than the digital models obtained with an intraoral scanner.
- Open Access
- 5 September 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (12)
A hipossalivação e sua relação com medicamentos anti-hipertensivos
A Hipertensão Arterial Sistêmica é uma doença crônica multifatorial, que, caso não seja tratada de forma contínua, aumenta consideravelmente o risco de eventos cardiovasculares, que podem ser fatais. Para o controle dessa condição clínica, existe uma grande diversidade de medicamentos com mecanismos de ação distintos, e efeitos adversos variados. Devido à alta prevalência de pacientes hipertensos nos consultórios odontológicos, este trabalho tem por objetivo demonstrar a influência do uso de medicamentos anti-hipertensivos no desenvolvimento da hipossalivação. A hipossalivação consiste na diminuição quantitativa do fluxo salivar, que pode ser causada por uma série de fatores, e que leva à sensação de boca seca pelo paciente, denominada xerostomia. Este estudo revisa as classes medicamentosas mais utilizadas para o tratamento da hipertensão arterial sistêmica, que apresentam como um de seus efeitos colaterais a hipossalivação. Entre suas diversas funções, a saliva exerce um importante controle na microbiota bucal. Sua ausência ou a diminuição de seu fluxo normal pode causar um aumento na prevalência de cárie, doença periodontal, patógenos oportunistas e traumatismos, principalmente em usuários de próteses. Por fim, são propostos métodos para a redução dos efeitos adversos dos medicamentos causadores de hipossalivação.
- 5 September 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (12)
Open AccessA hipossalivação e sua relação com medicamentos anti-hipertensivos
A Hipertensão Arterial Sistêmica é uma doença crônica multifatorial, que, caso não seja tratada de forma contínua, aumenta consideravelmente o risco de eventos cardiovasculares, que podem ser fatais. Para o controle dessa condição clínica, existe uma grande diversidade de medicamentos com mecanismos de ação distintos, e efeitos adversos variados. Devido à alta prevalência de pacientes hipertensos nos consultórios odontológicos, este trabalho tem por objetivo demonstrar a influência do uso de medicamentos anti-hipertensivos no desenvolvimento da hipossalivação. A hipossalivação consiste na diminuição quantitativa do fluxo salivar, que pode ser causada por uma série de fatores, e que leva à sensação de boca seca pelo paciente, denominada xerostomia. Este estudo revisa as classes medicamentosas mais utilizadas para o tratamento da hipertensão arterial sistêmica, que apresentam como um de seus efeitos colaterais a hipossalivação. Entre suas diversas funções, a saliva exerce um importante controle na microbiota bucal. Sua ausência ou a diminuição de seu fluxo normal pode causar um aumento na prevalência de cárie, doença periodontal, patógenos oportunistas e traumatismos, principalmente em usuários de próteses. Por fim, são propostos métodos para a redução dos efeitos adversos dos medicamentos causadores de hipossalivação.
- Open Access
- 13 May 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (7)
Flexural strength of milled polymer bars, with and without glass fiber reinforcement
The aim of this study is to test and compare the flexural strength of milled polymer bars, with and without glass fiber reinforcement. The number of samples in the study was defined through a pilot study on a universal testing machine (EMIC) (n = 5). The brands analyzed in this study were Arch Free Metal, Zantex, Bioplas and PEEK. All samples were submitted to thermal aging before the three-point flexural test. Fracture patterns were analyzed using a Scanning Electron Microscope. Results show that the Arch Free Metal bar presented the largest flexural strength, followed by Zantex and PEEK bars, that lacked statistical difference, and Bioplas bars. Regarding fracture patterns, Arch Free Metal and Zantex bars were partially fractured and showed partial glass fiber rupture; PEEK bars were not fractured and showed plastic behavior; and Bioplas bars were fractured. It is possible to conclude that the reinforced polymer bar Arch Free Metal has a better performance in terms of flexural strength than the other tested materials.
- 13 May 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (7)
Open AccessFlexural strength of milled polymer bars, with and without glass fiber reinforcement
The aim of this study is to test and compare the flexural strength of milled polymer bars, with and without glass fiber reinforcement. The number of samples in the study was defined through a pilot study on a universal testing machine (EMIC) (n = 5). The brands analyzed in this study were Arch Free Metal, Zantex, Bioplas and PEEK. All samples were submitted to thermal aging before the three-point flexural test. Fracture patterns were analyzed using a Scanning Electron Microscope. Results show that the Arch Free Metal bar presented the largest flexural strength, followed by Zantex and PEEK bars, that lacked statistical difference, and Bioplas bars. Regarding fracture patterns, Arch Free Metal and Zantex bars were partially fractured and showed partial glass fiber rupture; PEEK bars were not fractured and showed plastic behavior; and Bioplas bars were fractured. It is possible to conclude that the reinforced polymer bar Arch Free Metal has a better performance in terms of flexural strength than the other tested materials.
- Open Access
- 17 April 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (6)
Influence of different surface treatments on the shear strength between acrylic resin and two materials: Polyether Ether Ketone (PEEK) / ZANTEXR
The present study assesses the shear strength of Polyether Ether Ketone (PEEK) and Zantex to thermopolymerizable acrylic resin (TAR) with different surface treatments. To this end, 100 test specimens were produced and divided into two groups: G1(PEEK + TAR) and G2 (Zantex + TAR). Each group was subdivided into the subgroups A, B, C, D and E (n=10) according to surface pre-treatment: A: TAR + PEEK/Zantex without surface treatment (control); B: TAR + PEEK/Zantex treated with Palabond; C: TAR + PEEK/Zantex blasted with aluminum oxide (Al2O3) of 125 µm; D: TAR + PEEK /Zantex treated with Al2O3 of 125 µm + Palabond; and E: TAR + PEEK/Zantex prepared with groove-shaped retentions. The structures were tested in a Universal testing machine EMIC DL2000. Two-way variance analysis showed significant difference between materials and surface treatments (p < 0.001). Multiple comparisons were done with Tukey’s test and failure modes were analyzed with the G test. Statistical analysis showed that Zantex outperformed PEEK for most treatments and showed similar performance in the subgroups treated with Al2O3. Within the PEEK group, the use of grooves and Palabond combined with blasting showed the best results; in the Zantex group, the best results were obtained with Palabond and Palabond combined with blasting. Regarding failure modes, PEEK showed only adhesive failures and Zantex’s failures were dependent on treatment. Therefore, the surface treatment method applied to the polymers studied here contribute to the material’s adhesion to acrylic resin.
- 17 April 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (6)
Open AccessInfluence of different surface treatments on the shear strength between acrylic resin and two materials: Polyether Ether Ketone (PEEK) / ZANTEXR
The present study assesses the shear strength of Polyether Ether Ketone (PEEK) and Zantex to thermopolymerizable acrylic resin (TAR) with different surface treatments. To this end, 100 test specimens were produced and divided into two groups: G1(PEEK + TAR) and G2 (Zantex + TAR). Each group was subdivided into the subgroups A, B, C, D and E (n=10) according to surface pre-treatment: A: TAR + PEEK/Zantex without surface treatment (control); B: TAR + PEEK/Zantex treated with Palabond; C: TAR + PEEK/Zantex blasted with aluminum oxide (Al2O3) of 125 µm; D: TAR + PEEK /Zantex treated with Al2O3 of 125 µm + Palabond; and E: TAR + PEEK/Zantex prepared with groove-shaped retentions. The structures were tested in a Universal testing machine EMIC DL2000. Two-way variance analysis showed significant difference between materials and surface treatments (p < 0.001). Multiple comparisons were done with Tukey’s test and failure modes were analyzed with the G test. Statistical analysis showed that Zantex outperformed PEEK for most treatments and showed similar performance in the subgroups treated with Al2O3. Within the PEEK group, the use of grooves and Palabond combined with blasting showed the best results; in the Zantex group, the best results were obtained with Palabond and Palabond combined with blasting. Regarding failure modes, PEEK showed only adhesive failures and Zantex’s failures were dependent on treatment. Therefore, the surface treatment method applied to the polymers studied here contribute to the material’s adhesion to acrylic resin.
- Open Access
- 9 March 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (4)
Análisis de la resistencia adhesiva de postes de fibra de vidrio sometidos al ensayo mecánico de cizallamiento por extrusión en diferentes protocolos de cementación
El objetivo fue evaluar la resistencia al cizallamiento por extrusión y verificar el tipo de falla de postes de fibra de vidrio que han recibido diferentes tratamientos de superficie, y testar el adhesivo multiuso Single Bond Universal® (3M ESPE). Métodos: Ochenta incisivos bovinos con tratamiento endodóntico fueran aleatoriamente repartidos en cuatro grupos; Grupo I: los postes recibieron aplicación de silano; Grupo II: ningún tipo de tratamiento; Grupo III: silano y adhesivo; y Grupo IV: solamente adhesivo. Los grupos fueran sometidos a ciclaje térmico por 5.000 ciclos, las raíces seccionadas y sometidas al teste push out. Resultados: Con la silanización y la aplicación del adhesivo, la resistencia entre el poste de fibra de vidrio y la dentina ha sido significativamente menor en relación solamente la silanización. La asociación silano-adhesivo causó perjuicio a la unión. Conclusiones: La silanización por si solo es que se constituyó en el tratamiento que mejoró la resistencia unión. Fallas adhesivas fueran las más prevalentes.
- 9 March 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (4)
Open AccessAnálisis de la resistencia adhesiva de postes de fibra de vidrio sometidos al ensayo mecánico de cizallamiento por extrusión en diferentes protocolos de cementación
El objetivo fue evaluar la resistencia al cizallamiento por extrusión y verificar el tipo de falla de postes de fibra de vidrio que han recibido diferentes tratamientos de superficie, y testar el adhesivo multiuso Single Bond Universal® (3M ESPE). Métodos: Ochenta incisivos bovinos con tratamiento endodóntico fueran aleatoriamente repartidos en cuatro grupos; Grupo I: los postes recibieron aplicación de silano; Grupo II: ningún tipo de tratamiento; Grupo III: silano y adhesivo; y Grupo IV: solamente adhesivo. Los grupos fueran sometidos a ciclaje térmico por 5.000 ciclos, las raíces seccionadas y sometidas al teste push out. Resultados: Con la silanización y la aplicación del adhesivo, la resistencia entre el poste de fibra de vidrio y la dentina ha sido significativamente menor en relación solamente la silanización. La asociación silano-adhesivo causó perjuicio a la unión. Conclusiones: La silanización por si solo es que se constituyó en el tratamiento que mejoró la resistencia unión. Fallas adhesivas fueran las más prevalentes.
- Open Access
- 9 March 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (4)
Influence of surface treatment on the shear strength of Ultra Translucent Multi Layered Zirconia Katana
The aim of this study is to assess how shear strength of Ultra Translucent Multi Layered Zirconia Katana (UTML) is affected by the conditioning with 10% hydrofluoric acid combined with the current surface treatment protocol: air, primer containing 10-MDP, and cement. Samples of UTML Zirconia Katana were machined to measure 5x5x10 units of measurement, attached, and divided into two groups. In the control group, samples were treated with 27 um aluminum oxide blasting at 4 bars, application of Zr primer containing 10-MDP and, finally, cement Panávia V5. In the experimental group, samples were also treated with 10% hydrofluoric acid following blasting and prior to the primer application. The test specimens were submitted to shear mechanical strength test on a universal testing machine EMIC DL2000 (EMIC, São Paulo, Brazil), surface analysis with Scanning Electron Microscope (SEM) (Sputter Coaster Emitech, K450) and surface roughness. Results showed that the bond strength of specimens conditioned with acid was 41% higher (p = 0.031). Student’s t test showed that the samples conditioned with acid were rougher than those without conditioning (p = 0.045). Microscopic analysis showed surface alterations on samples conditioned with acid. It is possible to conclude that the group conditioned with hydrofluoric acid showed better adhesive behavior.
- 9 March 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (4)
Open AccessInfluence of surface treatment on the shear strength of Ultra Translucent Multi Layered Zirconia Katana
The aim of this study is to assess how shear strength of Ultra Translucent Multi Layered Zirconia Katana (UTML) is affected by the conditioning with 10% hydrofluoric acid combined with the current surface treatment protocol: air, primer containing 10-MDP, and cement. Samples of UTML Zirconia Katana were machined to measure 5x5x10 units of measurement, attached, and divided into two groups. In the control group, samples were treated with 27 um aluminum oxide blasting at 4 bars, application of Zr primer containing 10-MDP and, finally, cement Panávia V5. In the experimental group, samples were also treated with 10% hydrofluoric acid following blasting and prior to the primer application. The test specimens were submitted to shear mechanical strength test on a universal testing machine EMIC DL2000 (EMIC, São Paulo, Brazil), surface analysis with Scanning Electron Microscope (SEM) (Sputter Coaster Emitech, K450) and surface roughness. Results showed that the bond strength of specimens conditioned with acid was 41% higher (p = 0.031). Student’s t test showed that the samples conditioned with acid were rougher than those without conditioning (p = 0.045). Microscopic analysis showed surface alterations on samples conditioned with acid. It is possible to conclude that the group conditioned with hydrofluoric acid showed better adhesive behavior.
- Open Access
- 6 February 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (3)
Shear bond strength of resinous cements to Zirconia Katana™ UTML
The aim of this study is to assess the bond strength of three resinous cements to Zirconia Katana™ UTML (Kuraray Noritake Dental Inc, Miyoshi, Aichi, Japan). Thirty-six blocks of Zirconia were milled and included in polyvynil chloride (PVC) pipes with self-polymerizable acrylic resin. Each sample was polished in a polishing machine, blasted with aluminum particles, cleaned with ultrasound, and dried with compressed air. The cementation was done according to the protocol recommended by the manufacturer. The samples were divided in 3 groups (n=12) according to the resinous cement used: Group R - RelyX™ U200 Automix (3M ESPE, Sumaré, São Paulo, Brazil); Group M - Multilink® N (Ivoclar Vivadent, Schaan, Liechtenstein); and Group P - Panavia™ V5 Paste (Kuraray Noritake Dental Inc, Cotia, São Paulo, Brazil). The shear stress test was performed in EMIC DL2000 (EMIC, São Paulo, SP, Brazil), and failure type was analyzed. Average bond strengths were 5.4 kgf, 5.8 kgf, and 6.68 kgf for groups R1, M1 and P1, respectively. Variance analysis showed no significant difference between groups. None of the groups showed cohesive failure; there was no significant difference in the frequency of mixed and adhesive failure between groups. All three cements showed similar performance in the tests.
- 6 February 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (3)
Open AccessShear bond strength of resinous cements to Zirconia Katana™ UTML
The aim of this study is to assess the bond strength of three resinous cements to Zirconia Katana™ UTML (Kuraray Noritake Dental Inc, Miyoshi, Aichi, Japan). Thirty-six blocks of Zirconia were milled and included in polyvynil chloride (PVC) pipes with self-polymerizable acrylic resin. Each sample was polished in a polishing machine, blasted with aluminum particles, cleaned with ultrasound, and dried with compressed air. The cementation was done according to the protocol recommended by the manufacturer. The samples were divided in 3 groups (n=12) according to the resinous cement used: Group R - RelyX™ U200 Automix (3M ESPE, Sumaré, São Paulo, Brazil); Group M - Multilink® N (Ivoclar Vivadent, Schaan, Liechtenstein); and Group P - Panavia™ V5 Paste (Kuraray Noritake Dental Inc, Cotia, São Paulo, Brazil). The shear stress test was performed in EMIC DL2000 (EMIC, São Paulo, SP, Brazil), and failure type was analyzed. Average bond strengths were 5.4 kgf, 5.8 kgf, and 6.68 kgf for groups R1, M1 and P1, respectively. Variance analysis showed no significant difference between groups. None of the groups showed cohesive failure; there was no significant difference in the frequency of mixed and adhesive failure between groups. All three cements showed similar performance in the tests.
- Open Access
- 6 February 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (3)
Analysis of compressive strength of occlusal splints manufactured with three liquid resins at three angles of orientation on 3D printer
The aim of this study is to analyze the compressive strength of occlusal splints manufactured with three different liquid resins in a 3D printer and in three angles of orientation. The resins used here are (n=12): Resilab Clear (Wilcos do Brasil, Petrópolis, RJ, Brazil), Prizma Smart Print Bio (Makertech Labs, Tatuí, SP, Brazil), and Cosmos Splint (Yller Biomateriais, Pelotas, RS, Brazil); each resin group are divided into three subgroups according to orientation of manufacture: 0, 45 and 90 degrees. A dental manikin was scanned and the file was used to manufacture a steel hemiarch model. This model was used to design the occlusal splints and as a basis for the tests. The splints were designed with flat occlusal surface and minimum thickness of 2 mm. The compressive test was performed with constant force of 200N, velocity of 0.5 mm/min, along the entire occlusal surface until fracture. Results show no difference between the resins, regardless of orientation of manufacture. The orientation showed no intragroup effect for resins Prizma Smart Print Bio and Resilab Clear; the resin Cosmos showed larger compressive strength for the samples manufactured at 45 degrees than at 0 degree. The 90-degree samples were intermediary and showed no difference from other angles. This study shows that the three resins had similar behavior in terms of compressive strength, except for the intragroup effect of orientation of Cosmos Splint resin, where plates manufactured at 0 degree performed worse than those at 45 degrees.
- 6 February 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (3)
Open AccessAnalysis of compressive strength of occlusal splints manufactured with three liquid resins at three angles of orientation on 3D printer
The aim of this study is to analyze the compressive strength of occlusal splints manufactured with three different liquid resins in a 3D printer and in three angles of orientation. The resins used here are (n=12): Resilab Clear (Wilcos do Brasil, Petrópolis, RJ, Brazil), Prizma Smart Print Bio (Makertech Labs, Tatuí, SP, Brazil), and Cosmos Splint (Yller Biomateriais, Pelotas, RS, Brazil); each resin group are divided into three subgroups according to orientation of manufacture: 0, 45 and 90 degrees. A dental manikin was scanned and the file was used to manufacture a steel hemiarch model. This model was used to design the occlusal splints and as a basis for the tests. The splints were designed with flat occlusal surface and minimum thickness of 2 mm. The compressive test was performed with constant force of 200N, velocity of 0.5 mm/min, along the entire occlusal surface until fracture. Results show no difference between the resins, regardless of orientation of manufacture. The orientation showed no intragroup effect for resins Prizma Smart Print Bio and Resilab Clear; the resin Cosmos showed larger compressive strength for the samples manufactured at 45 degrees than at 0 degree. The 90-degree samples were intermediary and showed no difference from other angles. This study shows that the three resins had similar behavior in terms of compressive strength, except for the intragroup effect of orientation of Cosmos Splint resin, where plates manufactured at 0 degree performed worse than those at 45 degrees.
- Open Access
- 16 January 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (2)
The biomechanics of the bone and of metal, Zantex and PEEK bars in normal and osteoporotic condition, surrounding implants over protocols: an analysis by the Finite Element Method
This study aims to assess the biomechanical behavior of the alveolar bone surrounding the implants over protocol with metal, Polyether ether ketone (PEEK) and Zantex bars, in normal and osteoporotic conditions. For the simulation, geometric models of the mandibular arch were designed containing 5 implants and two variables. The first variable is the bone condition - normal and osteoporotic-, and the second is the material used in the protocol bars – metal, PEEK and Zantex. Simulation was performed using the Finite Elements Method. Results showed that the largest load peaks were concentrated in the medullary bone, both in the normal and osteoporotic conditions. The osteoporotic bone was subjected to more loads than the normal bone in all simulated structures. PEEK and Zantex bars are generally effective load dissipators, showing better performance than Ni-Cr in both types of bone. It is important to assess the bone condition and its relationship with the material used in protocol-type prostheses infrastructure.
- 16 January 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (2)
Open AccessThe biomechanics of the bone and of metal, Zantex and PEEK bars in normal and osteoporotic condition, surrounding implants over protocols: an analysis by the Finite Element Method
This study aims to assess the biomechanical behavior of the alveolar bone surrounding the implants over protocol with metal, Polyether ether ketone (PEEK) and Zantex bars, in normal and osteoporotic conditions. For the simulation, geometric models of the mandibular arch were designed containing 5 implants and two variables. The first variable is the bone condition - normal and osteoporotic-, and the second is the material used in the protocol bars – metal, PEEK and Zantex. Simulation was performed using the Finite Elements Method. Results showed that the largest load peaks were concentrated in the medullary bone, both in the normal and osteoporotic conditions. The osteoporotic bone was subjected to more loads than the normal bone in all simulated structures. PEEK and Zantex bars are generally effective load dissipators, showing better performance than Ni-Cr in both types of bone. It is important to assess the bone condition and its relationship with the material used in protocol-type prostheses infrastructure.
- Open Access
- 1 January 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (1)
Associação entre a infecção pelo SARS-CoV-2 e o aparecimento de manifestações orais: uma revisão sistemática
O objetivo desta revisão sistemática qualitativa é estabelecer a relações entre a infecção pelo SARS-CoV-2 e o aparecimento de manifestações bucais. Os resultados foram obtidos após extensa pesquisa e revisão de artigos atualmente publicados sobre o tema em questão. Estudos apontam que a mucosa da cavidade oral pode ser uma rota de alto risco para a infecção pelo SARS-CoV-2, levantando a hipótese de que lesões podem se desenvolver na cavidade bucal em decorrência da infecção pelo vírus. As alterações mais comumente relatadas são os distúrbios do paladar, como disgeusia, hipogeusia e ageusia. Lesões de mucosa, como úlceras, erosões, mucosites, bolhas, máculas e placas, também foram encontradas em pacientes acometidos, variando em quantidade, aparência de cor e localização. Sensação de boca seca, alterações na ATM e infecções virais e fúngicas oportunistas foram relatadas em alguns casos. No entanto, ainda não está clara a relação direta de causa e efeito entre a infecção pelo SARS-CoV-2 e o aparecimento de lesões na cavidade bucal. Autores defendem que o estado geral de imunossupressão, estresse e/ou alterações vasculares, inerentes à doença COVID-19, podem explicar o aparecimento dessas lesões. É evidente, portanto, que existe uma relação entre COVID-19 e o desenvolvimento de lesões bucais, porém mais estudos são necessários para entender a patogenia dessas alterações.
- 1 January 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (1)
Open AccessAssociação entre a infecção pelo SARS-CoV-2 e o aparecimento de manifestações orais: uma revisão sistemática
O objetivo desta revisão sistemática qualitativa é estabelecer a relações entre a infecção pelo SARS-CoV-2 e o aparecimento de manifestações bucais. Os resultados foram obtidos após extensa pesquisa e revisão de artigos atualmente publicados sobre o tema em questão. Estudos apontam que a mucosa da cavidade oral pode ser uma rota de alto risco para a infecção pelo SARS-CoV-2, levantando a hipótese de que lesões podem se desenvolver na cavidade bucal em decorrência da infecção pelo vírus. As alterações mais comumente relatadas são os distúrbios do paladar, como disgeusia, hipogeusia e ageusia. Lesões de mucosa, como úlceras, erosões, mucosites, bolhas, máculas e placas, também foram encontradas em pacientes acometidos, variando em quantidade, aparência de cor e localização. Sensação de boca seca, alterações na ATM e infecções virais e fúngicas oportunistas foram relatadas em alguns casos. No entanto, ainda não está clara a relação direta de causa e efeito entre a infecção pelo SARS-CoV-2 e o aparecimento de lesões na cavidade bucal. Autores defendem que o estado geral de imunossupressão, estresse e/ou alterações vasculares, inerentes à doença COVID-19, podem explicar o aparecimento dessas lesões. É evidente, portanto, que existe uma relação entre COVID-19 e o desenvolvimento de lesões bucais, porém mais estudos são necessários para entender a patogenia dessas alterações.