Linguo Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Linguo Liu has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Anwen Shen
2 shared publications- Anwen Shen
National Key Laboratory of Science and Technology on Multispectral Information Processing and Key Laboratory of Image Processing and Intelligent Control, School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan, China
2 shared publications - Jie Ye
National Key Laboratory of Science and Technology on Multispectral Information Processing and Key Laboratory of Image Processing and Intelligent Control, School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan, China
2 shared publications Jinbang Xu
2 shared publications- Songtao Huang
National Key Laboratory of Science and Technology on Multispectral Information Processing and Key Laboratory of Image Processing and Intelligent Control, School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan, China
2 shared publications - Banghua Du
China Southern Power Grid Technology Co., Ltd., Guangzhou 510080, China
1 shared publication
Latest Publications
- Open Access
- 20 May 2026
- Published by MDPI AG in Journal of Composites Science
- Vol. 10 (5) , 278
Coupled Response of Internal Pneumatic Pressurization and External Mechanical Loading in Rhombic Composite Laminates
This study investigates the coupled quasi-static response and stable-state switching behavior of mechanically prestressed rhombic bistable composite laminates under internal pneumatic pressurization and external mechanical loading. A rhombic bistable composite laminate with embedded fluidic channels is proposed, where pneumatic pressurization is employed to reconfigure the deformation state and modulate the coupling between the laminate morphology and external actuation loads. An efficient reduced-order analytical model is developed to capture the interactions among geometric configuration, prestrain distribution, internal pressure, and external mechanical loading, enabling the rapid prediction of the deformation evolution and load–deflection response under coupled loading conditions. The main innovation of this work is integrating rhombic geometric tailoring, intrinsic pneumatic actuation, and multimode external loading into a unified analytical framework. The results demonstrate that the interior angle, prestrain distribution, and loading mode can effectively regulate equilibrium morphology, snap-through energy, and actuation efficiency. Parametric analyses reveal that the rhombic geometry introduces pronounced shear–bending coupling, providing an additional geometric degree of freedom for tailoring bistable configurations and energy barriers. In particular, a smaller interior angle generally reduces the snap-through energy barrier, whereas front-side prestrain increases the energy required for stable-state switching by enhancing the initial curvature. Comparisons among different loading modes further show that transverse point loading provides the highest energy conversion efficiency, in-plane loading requires the largest input energy, and pressure-assisted actuation exhibits intermediate efficiency. These findings provide fundamental insights and practical design guidelines for programmable morphing and load-efficient stable-state switching for rhombic composite laminates operating under coupled internal–external loading environments.
- 20 May 2026
- Published by MDPI AG in Journal of Composites Science
- Vol. 10 (5) , 278
Open AccessCoupled Response of Internal Pneumatic Pressurization and External Mechanical Loading in Rhombic Composite Laminates
This study investigates the coupled quasi-static response and stable-state switching behavior of mechanically prestressed rhombic bistable composite laminates under internal pneumatic pressurization and external mechanical loading. A rhombic bistable composite laminate with embedded fluidic channels is proposed, where pneumatic pressurization is employed to reconfigure the deformation state and modulate the coupling between the laminate morphology and external actuation loads. An efficient reduced-order analytical model is developed to capture the interactions among geometric configuration, prestrain distribution, internal pressure, and external mechanical loading, enabling the rapid prediction of the deformation evolution and load–deflection response under coupled loading conditions. The main innovation of this work is integrating rhombic geometric tailoring, intrinsic pneumatic actuation, and multimode external loading into a unified analytical framework. The results demonstrate that the interior angle, prestrain distribution, and loading mode can effectively regulate equilibrium morphology, snap-through energy, and actuation efficiency. Parametric analyses reveal that the rhombic geometry introduces pronounced shear–bending coupling, providing an additional geometric degree of freedom for tailoring bistable configurations and energy barriers. In particular, a smaller interior angle generally reduces the snap-through energy barrier, whereas front-side prestrain increases the energy required for stable-state switching by enhancing the initial curvature. Comparisons among different loading modes further show that transverse point loading provides the highest energy conversion efficiency, in-plane loading requires the largest input energy, and pressure-assisted actuation exhibits intermediate efficiency. These findings provide fundamental insights and practical design guidelines for programmable morphing and load-efficient stable-state switching for rhombic composite laminates operating under coupled internal–external loading environments.
- Open Access
- 25 May 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 159
Controller parameter optimization of LCL-type grid-connected inverters for passivity margin enhancement
- 25 May 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 159
Open AccessController parameter optimization of LCL-type grid-connected inverters for passivity margin enhancement
- Open Access
- 6 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 66505-66515
Passivity Enhancement and Grid-Current Distortion Mitigation for Inverter-Side Current Controlled LCL-Type Grid-Connected Inverters
Inverter-side current (ISC) control has been widely used in LCL-type grid-connected inverters due to its cost-effectiveness. However, the ISC-controlled inverters suffer from instability and injected grid current distortion under weak grid conditions, such as grid impedance variations and background harmonics. To solve these problems, this article presents an admittance shaping scheme based on capacitor voltage feedforward (CVF) for ISC-controlled LCL-type grid-connected inverters. A delay compensated proportional CVF method is used to shape the inverter output admittance to be passive almost up to the Nyquist frequency. Then, another high-pass filter-based CVF method is employed to shape the grid harmonic admittance to greatly reduce the admittance magnitude at the harmonic frequencies. Thanks to the proposed admittance shaping scheme, the ISC-controlled inverter system can operate stably regardless of the grid impedance and has excellent grid-current harmonic suppression capability. The effectiveness of the proposed admittance shaping scheme is verified by detailed simulation and experimental results.
- 6 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 66505-66515
Open AccessPassivity Enhancement and Grid-Current Distortion Mitigation for Inverter-Side Current Controlled LCL-Type Grid-Connected Inverters
Inverter-side current (ISC) control has been widely used in LCL-type grid-connected inverters due to its cost-effectiveness. However, the ISC-controlled inverters suffer from instability and injected grid current distortion under weak grid conditions, such as grid impedance variations and background harmonics. To solve these problems, this article presents an admittance shaping scheme based on capacitor voltage feedforward (CVF) for ISC-controlled LCL-type grid-connected inverters. A delay compensated proportional CVF method is used to shape the inverter output admittance to be passive almost up to the Nyquist frequency. Then, another high-pass filter-based CVF method is employed to shape the grid harmonic admittance to greatly reduce the admittance magnitude at the harmonic frequencies. Thanks to the proposed admittance shaping scheme, the ISC-controlled inverter system can operate stably regardless of the grid impedance and has excellent grid-current harmonic suppression capability. The effectiveness of the proposed admittance shaping scheme is verified by detailed simulation and experimental results.
- Open Access
An Improved Frequency-Adaptive Virtual Variable Sampling-Based Repetitive Control for an Active Power Filter
To eliminate the harmonics caused by nonlinear loads, repetitive controllers are widely applied as current controllers for active power filters (APF). In practice, a variation in grid frequency leads to the appearance of a fractional-order delay filter. As a result, the resonant frequency of the repetitive controller will deviate from the fundamental frequency and the controller cannot compensate for harmonics accurately. To solve this problem, an improved frequency-adaptive repetitive controller based on virtual variable sampling (IMFA-VVS-RC) for APF is proposed in this paper. To enhance the system stability margin, the proposed RC introduces an infinite impulse response (IIR) low-pass filter. The proposed RC has a high stability margin at high frequencies due to the low gain of the IIR low-pass filter in the region above the cutoff frequency. In this way, the influence of model uncertainty and parameter uncertainty on system stability are reduced at high frequencies. At the same time, compared with the conventional repetitive controller (CRC), the proposed RC for APF has a better harmonic suppression ability when the frequency varies. Experiments have verified the effectiveness of the scheme adopted for APF.
Open AccessAn Improved Frequency-Adaptive Virtual Variable Sampling-Based Repetitive Control for an Active Power Filter
To eliminate the harmonics caused by nonlinear loads, repetitive controllers are widely applied as current controllers for active power filters (APF). In practice, a variation in grid frequency leads to the appearance of a fractional-order delay filter. As a result, the resonant frequency of the repetitive controller will deviate from the fundamental frequency and the controller cannot compensate for harmonics accurately. To solve this problem, an improved frequency-adaptive repetitive controller based on virtual variable sampling (IMFA-VVS-RC) for APF is proposed in this paper. To enhance the system stability margin, the proposed RC introduces an infinite impulse response (IIR) low-pass filter. The proposed RC has a high stability margin at high frequencies due to the low gain of the IIR low-pass filter in the region above the cutoff frequency. In this way, the influence of model uncertainty and parameter uncertainty on system stability are reduced at high frequencies. At the same time, compared with the conventional repetitive controller (CRC), the proposed RC for APF has a better harmonic suppression ability when the frequency varies. Experiments have verified the effectiveness of the scheme adopted for APF.
- 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (7) , 7892-7902
Accurate Harmonic Calculation for Digital SPWM of VSI With Dead-Time Effect
This paper presents an accurate model of digitally controlled voltage source inverter (VSI) with dead-time effect. The impact of two nonlinear behaviors of digital sinusoidal pulse width modulation (DSPWM) and dead-time on the output waveform is analyzed in time domain. The problematic waveform with SPWM is displayed, which highlights the necessity of establishing a new model. In frequency domain, considering the dead time effect on the current, double-Fourier transform is used to give a harmonic expression without a current sign function. Furthermore, this avoids the error caused by the measurement of the current polarity, so the exact amplitude of each harmonic of the output voltage can be accurately calculated, which is important for eliminating specific harmonics and improving power quality. Moreover, the problem caused by the current zero-crossing is solved. The result of the analysis is verified by simulation and experiment on DSP and SIC platform. And the result shows that the harmonics and their amplitudes are in good agreement with our formula.
- 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (7) , 7892-7902
Accurate Harmonic Calculation for Digital SPWM of VSI With Dead-Time Effect
This paper presents an accurate model of digitally controlled voltage source inverter (VSI) with dead-time effect. The impact of two nonlinear behaviors of digital sinusoidal pulse width modulation (DSPWM) and dead-time on the output waveform is analyzed in time domain. The problematic waveform with SPWM is displayed, which highlights the necessity of establishing a new model. In frequency domain, considering the dead time effect on the current, double-Fourier transform is used to give a harmonic expression without a current sign function. Furthermore, this avoids the error caused by the measurement of the current polarity, so the exact amplitude of each harmonic of the output voltage can be accurately calculated, which is important for eliminating specific harmonics and improving power quality. Moreover, the problem caused by the current zero-crossing is solved. The result of the analysis is verified by simulation and experiment on DSP and SIC platform. And the result shows that the harmonics and their amplitudes are in good agreement with our formula.
- 18 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (9) , 7965-7974
Frequency Adaptive Proportional-Repetitive Control for Grid-Connected Inverters
The repetitive control (RC) scheme, which can achieve zero steady-state error tracking of any periodic signal with a known integer period, is widely employed in grid-connected inverters to mitigate feed-in current harmonics. However, the conventional RC (CRC) scheme cannot exactly compensate harmonics with fractional period caused by grid frequency variations. Furthermore, the small RC gain of the CRC scheme causes slow transient response. In this article, a proportional-repetitive control (PRC) scheme, which can accommodate a larger RC gain than the CRC scheme, is proposed to provide fast transient response for RC systems. In order to enhance the frequency adaptability of the PRC scheme with a fixed sampling rate, the Thiran all-pass filter, which is a type of infinite impulse response filter for approximating the fractional delay (FD), is used as the FD filter to achieve fast online tuning of the FD and the fast update of the coefficients. The proposed frequency adaptive PRC (FA-PRC) scheme provides grid-connected inverters with a control solution with excellent dynamic performance and accurate frequency adaptability to eliminate harmonic distortion even in the presence of grid frequency variations. A comprehensive series of experiments have demonstrated the effectiveness of the proposed FA-PRC scheme.
- 18 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (9) , 7965-7974
Frequency Adaptive Proportional-Repetitive Control for Grid-Connected Inverters
The repetitive control (RC) scheme, which can achieve zero steady-state error tracking of any periodic signal with a known integer period, is widely employed in grid-connected inverters to mitigate feed-in current harmonics. However, the conventional RC (CRC) scheme cannot exactly compensate harmonics with fractional period caused by grid frequency variations. Furthermore, the small RC gain of the CRC scheme causes slow transient response. In this article, a proportional-repetitive control (PRC) scheme, which can accommodate a larger RC gain than the CRC scheme, is proposed to provide fast transient response for RC systems. In order to enhance the frequency adaptability of the PRC scheme with a fixed sampling rate, the Thiran all-pass filter, which is a type of infinite impulse response filter for approximating the fractional delay (FD), is used as the FD filter to achieve fast online tuning of the FD and the fast update of the coefficients. The proposed frequency adaptive PRC (FA-PRC) scheme provides grid-connected inverters with a control solution with excellent dynamic performance and accurate frequency adaptability to eliminate harmonic distortion even in the presence of grid frequency variations. A comprehensive series of experiments have demonstrated the effectiveness of the proposed FA-PRC scheme.