SLShupeng Li

Shupeng Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shupeng Li has a total of 298 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Local control of Cre-regulated genetic modeling in vivo using wireless implantable optoelectronics

    by Trisha Bansal, Min-Kyu Lee, Courtney Coleman, Young-Mee Kim, Dane Hintermueller, Yaner Chen, Varsha Sreekanth, Chad R. Haney, Olga A. Karginova, Raudel Avila, et al.

    Effective modeling of chronic human diseases in vivo requires precise spatiotemporal regulation of molecular processes at defined tissue locations. Optogenetic and optoelectronic tools can provide such control but targeting internal organs such as the lungs remain challenging. To address this, we developed E-LightR-Cre recombinase, enabling precise, spatially restricted gene activation with no dark-state activity and robust blue light responsiveness. To achieve local activation of E-LightR-Cre in specific organ sites, we engineered wireless, fully implantable optoelectronic devices enabling focal illumination of murine lungs with no discernible organ damage. The size of the activated area is controlled by modulating light intensity and duration. Using implanted optoelectronic devices, we activated E-LightR-Cre in a selected area of mouse lungs and achieved local regulation of targeted genes. Light-regulated expression of the oncogenic KRas-G12D mutant in mouse lungs induced local formation of oncogenic lesions. These results show that our protein engineering and adaptable optoelectronic approaches enable facile application of optogenetic tools for locally controlled disease modeling in vivo.

  • Open Access

    Healing cascades and infections in wounds monitored using a wearable sensor of gaseous flux

    by Seunghee Cho, Ansen Tan, Zixi Chen, Kyung Rok Pyun, Shupeng Li, Fujie Yin, Aiwa Zhang, Neena Feldman, Evan J. Neuhart, Amara Devi Moreno, et al.

    Capabilities for quantitative monitoring of chronic wounds remain an unmet clinical need, as existing diagnostic approaches rely on semiquantitative evaluation of symptoms that lack sensitivity especially during early stages of infection. Here, we present a scheme for tracking wound physiology that leverages a miniature, wireless skin-interfaced device for noncontact, transient measurements of the flux of volatile organic compounds (VOCs) and water vapor from the wound microenvironment. Unlike emerging smart bandage platforms that rely on physical contact with the fragile wound bed to interrogate liquid-phase biomarkers, this strategy uses an engineered microclimate and suspended suite of sensors to measure the diffusive transport of wound-derived gases across the wound surface but separated from it. The result enables quantitative evaluation of metabolic activity and healing progression without perturbing the healing tissues. In biofilm growth models of Staphylococcus aureus , measurements demonstrate that trends in VOC flux correlate strongly with bacterial growth kinetics and precede any visible biofilm formation. Longitudinal monitoring of infected and noninfected wounds on diabetic mice shows that concurrent measurements of water vapor and VOC flux provide complementary physiological insights, capturing both the trajectory of barrier restoration and the dynamics of bacterial burden. The findings establish this noncontact sensing scheme as a distinct and clinically translatable paradigm for wound monitoring, with broad implications for noninvasive surveillance of disease states in which tissue metabolic activity and skin barrier integrity serve as actionable physiological readouts.

  • Open Access

    A wearable biomechanical system for medical evaluation of soft tissue disorders.

    by Min-Seung Jo, Hee-Sup Shin, Jin-Tae Kim, Shupeng Li, Sonwoo Jung, Jungyeon Kim, Tae Wan Park, Jodi L Johnson, Carrie Richardson, Eseosa Olive Osaghae, et al.

    Evaluating soft tissue elasticity provides critical biomechanical insights essential for the precise characterization of various physiological and pathological conditions. Here, we present the clinical validation of a wireless, compact wearable system designed for direct, location-specific monitoring of the elastic modulus of the skin and underlying tissues via vibro-rotational biomechanical dynamics. Validated by computational models and experiments, the device uses a tunable skin interface to enable depth-controlled measurements across diverse anatomical sites. Two human subject studies, one involving patients with cancer-related lymphedema and the other involving patients with systemic scleroderma, yield data that correlate with standard clinical metrics. This technology offers the potential for longitudinal assessments in these and other contexts, in both clinical and home settings.


  • Open Access

    Analytical modeling for suction cup designs for skin-interfaced wearable devices

    by Shupeng Li, John A. Rogers, Yonggang Huang

    Stable mounting is a central requirement for skin-interfaced wearable biomedical devices, because accurate and long-term measurements with clinical utility typically demand intimate contact with the skin, whereas practical use also requires gentle removal to minimize skin irritation and damage. Existing mounting strategies often struggle to satisfy these competing requirements simultaneously, especially under prolonged wear or in the presence of sweat and moisture. Suction-based mounting has recently emerged as a promising alternative because it can provide strong, reversible, and adhesive-free attachment, yet its underlying mechanics remain insufficiently understood. Here, we establish analytical models for the deformation and force of suction cups in a fully explicit form, covering both the cone suction cup and an optimized ring suction cup design. Unlike previous approaches that rely on indirect quantities such as the pressure difference and contact radius, which are not available before experiments and therefore cannot serve as controllable design variables, the present framework yields direct relations between suction performance and geometry parameters, material properties, and loading conditions, including the maximum push down displacement and the subsequent pull up displacement. The resulting formulas agree closely with accurate numerical solutions and lead to compact scaling laws that clearly identify how geometry and material parameters govern suction performance. These results provide a quantitative and physically transparent foundation for the design of suction-based mounting strategies in wearable devices.

  • A wirelessly powered, light-controlled, bioresorbable stimulation system with programmable polyphasic waveforms

    by Jong Uk Kim, Seung Gi Seo, Hongkai Wang, Eric Rytkin, Jiarui Gong, Jie Zhou, Junhwan Choi, Jiwon Kim, Sun Young Park, Anna Pfenniger, et al.


  • Open Access

    Hot‐Film and Calorimetric Methods With Transient Heating for Measurement of High Biofluid Flow Rate

    by Yuanting Wei, Shupeng Li, Kyung Rok Pyun, Tianyu Yang, Bosung Kim, Haotian Yang, John A. Rogers, Yonggang Huang, Haohui Zhang

    Accurate measurement of biofluid flow rate is critical for clinical diagnostics and physiological monitoring, such as in cerebrospinal fluid shunt assessment and vascular blood flow evaluation. Thermal flow sensors, particularly hot‐film and calorimetric types, are widely used in biomedical settings due to their broad dynamic range and long‐term stability. However, their performance declines at high flow rates. To overcome this drawback, we propose a transient heating method that applies a short‐duration thermal pulse and tracks the peak temperature response. This method, validated by experiments using artificial blood and vessels, significantly improves sensitivity to the flow rate change at high flow rates and reduces energy consumption. There exists an optimal heating time to maximize sensitivity to the flow rate. A contour plot of flow rate sensitivity vs. the heating time and flow rate is obtained to guide the selection of optimal heating time for different flow conditions.


  • Top Cited Papers

    A non-contact wearable device for monitoring epidermal molecular flux

    by Jaeho Shin, Joseph Woojin Song, Matthew Thomas Flavin, Seunghee Cho, Shupeng Li, Ansen Tan, Kyung Rok Pyun, Aaron G Huang, Huifeng Wang, Seongmin Jeong, et al.

    Existing wearable technologies rely on physical coupling to the body to establish optical1,2, fluidic3,4, thermal5,6 and/or mechanical7,8 measurement interfaces. Here we present a class of wearable device platforms that instead relies on physical decoupling to define an enclosed chamber immediately adjacent to the skin surface. Streams of vapourized molecular substances that pass out of or into the skin alter the properties of the microclimate defined in this chamber in ways that can be precisely quantified using an integrated collection of wireless sensors. A programmable, bistable valve dynamically controls access to the surrounding environment, thereby creating a transient response that can be quantitatively related to the inward and outward fluxes of the targeted species by analysing the time-dependent readings from the sensors. The systems reported here offer unique capabilities in measuring the flux of water vapour, volatile organic compounds and carbon dioxide from various locations on the body, each with distinct relevance to clinical care and/or exposure to hazardous vapours. Studies of healing processes associated with dermal wounds in models of healthy and diabetic mice and of responses in models using infected wounds reveal characteristic flux variations that provide important insights, particularly in scenarios in which the non-contact operation of the devices avoids potential damage to fragile tissues.


  • Wireless, battery-free, remote photoactivation of caged-morphine for photopharmacological pain modulation without side effects

    by Minsung Kim, Marc López-Cano, Kaiqing Zhang, Yue Wang, Xavier Gómez-Santacana, África Flores, Mingzheng Wu, Shupeng Li, Haohui Zhang, Yuanting Wei, et al.


  • Top Cited Papers

    Millimetre-scale bioresorbable optoelectronic systems for electrotherapy

    by Yamin Zhang, Eric Rytkin, Liangsong Zeng, Jong Uk Kim, Lichao Tang, Haohui Zhang, Aleksei Mikhailov, Kaiyu Zhao, Yue Wang, Li Ding, et al.

    Temporary pacemakers are essential for the care of patients with short-lived bradycardia in post-operative and other settings1,2,3,4. Conventional devices require invasive open-heart surgery or less invasive endovascular surgery, both of which are challenging for paediatric and adult patients5,6,7,8. Other complications9,10,11 include risks of infections, lacerations and perforations of the myocardium, and of displacements of external power supplies and control systems. Here we introduce a millimetre-scale bioresorbable optoelectronic system with an onboard power supply and a wireless, optical control mechanism with generalized capabilities in electrotherapy and specific application opportunities in temporary cardiac pacing. The extremely small sizes of these devices enable minimally invasive implantation, including percutaneous injection and endovascular delivery. Experimental studies demonstrate effective pacing in mouse, rat, porcine, canine and human cardiac models at both single-site and multi-site locations. Pairing with a skin-interfaced wireless device allows autonomous, closed-loop operation upon detection of arrhythmias. Further work illustrates opportunities in combining these miniaturized devices with other medical implants, with an example of arrays of pacemakers for individual or collective use on the frames of transcatheter aortic valve replacement systems, to provide unique solutions that address risks for atrioventricular block following surgeries. This base technology can be readily adapted for a broad range of additional applications in electrotherapy, such as nerve and bone regeneration, wound therapy and pain management.


  • Top Cited Papers

    Full freedom-of-motion actuators as advanced haptic interfaces

    by Kyoung-Ho Ha, Jaeyoung Yoo, Shupeng Li, Yuxuan Mao, Shengwei Xu, Hongyuan Qi, Hanbing Wu, Chengye Fan, Hanyin Yuan, Jin-Tae Kim, et al.

    The sense of touch conveys critical environmental information, facilitating object recognition, manipulation, and social interaction, and can be engineered through haptic actuators that stimulate cutaneous receptors. An unfulfilled challenge lies in haptic interface technologies that can engage all the various mechanoreceptors in a programmable, spatiotemporal fashion across large areas of the body. Here, we introduce a small-scale actuator technology that can impart omnidirectional, superimposable, dynamic forces to the surface of skin, as the basis for stimulating individual classes of mechanoreceptors or selected combinations of them. High-bit haptic information transfer and realistic virtual tactile sensations are possible, as illustrated through human subject perception studies in extended reality applications that include advanced hand navigation, realistic texture reproduction, and sensory substitution for music perception.