Haohui Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Haohui Zhang has a total of 274 co-authors. Here are the top co-authors by number of shared publications:
- Yonggang Huang
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
15 shared publications - John Allen Rogers
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, 60208, USA
11 shared publications Kaiqing Zhang
Department of Civil and Environmental Engineering, Northwestern University, Evanston, IL 60208, USA
8 shared publications- Yue Wang
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
6 shared publications - Mingzheng Wu
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, USA
5 shared publications - Shupeng Li
Department of Civil and Environmental Engineering, Northwestern University, Evanston, IL 60208, USA
5 shared publications
Latest Publications
- 16 October 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (42)
Local control of Cre-regulated genetic modeling in vivo using wireless implantable optoelectronics
Effective modeling of chronic human diseases in vivo requires precise spatiotemporal regulation of molecular processes at defined tissue locations. Optogenetic and optoelectronic tools can provide such control but targeting internal organs such as the lungs remain challenging. To address this, we developed E-LightR-Cre recombinase, enabling precise, spatially restricted gene activation with no dark-state activity and robust blue light responsiveness. To achieve local activation of E-LightR-Cre in specific organ sites, we engineered wireless, fully implantable optoelectronic devices enabling focal illumination of murine lungs with no discernible organ damage. The size of the activated area is controlled by modulating light intensity and duration. Using implanted optoelectronic devices, we activated E-LightR-Cre in a selected area of mouse lungs and achieved local regulation of targeted genes. Light-regulated expression of the oncogenic KRas-G12D mutant in mouse lungs induced local formation of oncogenic lesions. These results show that our protein engineering and adaptable optoelectronic approaches enable facile application of optogenetic tools for locally controlled disease modeling in vivo.
- 16 October 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (42)
Local control of Cre-regulated genetic modeling in vivo using wireless implantable optoelectronics
Effective modeling of chronic human diseases in vivo requires precise spatiotemporal regulation of molecular processes at defined tissue locations. Optogenetic and optoelectronic tools can provide such control but targeting internal organs such as the lungs remain challenging. To address this, we developed E-LightR-Cre recombinase, enabling precise, spatially restricted gene activation with no dark-state activity and robust blue light responsiveness. To achieve local activation of E-LightR-Cre in specific organ sites, we engineered wireless, fully implantable optoelectronic devices enabling focal illumination of murine lungs with no discernible organ damage. The size of the activated area is controlled by modulating light intensity and duration. Using implanted optoelectronic devices, we activated E-LightR-Cre in a selected area of mouse lungs and achieved local regulation of targeted genes. Light-regulated expression of the oncogenic KRas-G12D mutant in mouse lungs induced local formation of oncogenic lesions. These results show that our protein engineering and adaptable optoelectronic approaches enable facile application of optogenetic tools for locally controlled disease modeling in vivo.
- Open Access
- 18 September 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (38)
A compact, wireless fluorimeter system for continuous, real-time monitoring of tissue perfusion via in vivo fluorescence signals
In vivo fluorescence signals provide physiological and pathological insights for the interpretation of biological states associated with anatomical abnormalities or disease. Conventional methods for measuring fluorescence signals rely on bulky, costly instrumentation for imaging or for localized sensing. Here, we report a compact, wireless fluorimeter system for continuous, real-time measurements of the dynamics of fluorescence signals at locations of interest across the body. The approach represents a type of wearable that enables quantitative, interpretable fluorescence readouts and automatic data streaming to standard smart devices. The platform is compatible with injectable fluorescent species of medical relevance, such as indocyanine green, fluorescein, and methylene blue. Measurements from ischemic rodent and healthy porcine models, as well as those associated with limb amputation/replantation studies in rodents, demonstrate physiologically meaningful fluorescence profiles, with validation against ex situ blood analysis. These conceptual and technical advances offer the potential for convenient, continuous monitoring of fluorescence signals to support disease management and long-term patient care.
- 18 September 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (38)
Open AccessA compact, wireless fluorimeter system for continuous, real-time monitoring of tissue perfusion via in vivo fluorescence signals
In vivo fluorescence signals provide physiological and pathological insights for the interpretation of biological states associated with anatomical abnormalities or disease. Conventional methods for measuring fluorescence signals rely on bulky, costly instrumentation for imaging or for localized sensing. Here, we report a compact, wireless fluorimeter system for continuous, real-time measurements of the dynamics of fluorescence signals at locations of interest across the body. The approach represents a type of wearable that enables quantitative, interpretable fluorescence readouts and automatic data streaming to standard smart devices. The platform is compatible with injectable fluorescent species of medical relevance, such as indocyanine green, fluorescein, and methylene blue. Measurements from ischemic rodent and healthy porcine models, as well as those associated with limb amputation/replantation studies in rodents, demonstrate physiologically meaningful fluorescence profiles, with validation against ex situ blood analysis. These conceptual and technical advances offer the potential for convenient, continuous monitoring of fluorescence signals to support disease management and long-term patient care.
- 17 June 2026
- Published by Springer Nature in Nature Biomedical Engineering
Skin-interfaced microfluidic capsule and portable lab-on-a-disc platform for sweat-based monitoring of prenatal nutrient balance
Effective management of prenatal nutrient concentrations, such as those associated with folate, is critical for the health of the prospective mother and child, but quantifying them currently requires frequent blood tests and specialized laboratories. Human sweat is a non-invasive alternative to blood that is well suited for point-of-care biosensing. Here we present a skin-interfaced microcapsule that enables collection and storage of pristine, microlitre volumes of sweat and supports an efficient interface to a portable lab-on-a-disc platform for folate quantification. This platform automates an entire enzyme-linked immunoassay sequence for measuring folate in sweat, including incubation, washing, mixing and detection, and facilitates wireless data transmission. A series of tests in human participants reveal a dose-response relationship between oral intake of folate supplements and sweat folate levels, with a strong correlation in levels between sweat and serum. In addition, daily tracking of sweat folate concentrations shows clear differences between control periods without supplementation and daily intake periods. This technology creates possibilities for the routine use of sweat for precise point-of-care assessment of prenatal nutrient bioavailability.
- 17 June 2026
- Published by Springer Nature in Nature Biomedical Engineering
Skin-interfaced microfluidic capsule and portable lab-on-a-disc platform for sweat-based monitoring of prenatal nutrient balance
Effective management of prenatal nutrient concentrations, such as those associated with folate, is critical for the health of the prospective mother and child, but quantifying them currently requires frequent blood tests and specialized laboratories. Human sweat is a non-invasive alternative to blood that is well suited for point-of-care biosensing. Here we present a skin-interfaced microcapsule that enables collection and storage of pristine, microlitre volumes of sweat and supports an efficient interface to a portable lab-on-a-disc platform for folate quantification. This platform automates an entire enzyme-linked immunoassay sequence for measuring folate in sweat, including incubation, washing, mixing and detection, and facilitates wireless data transmission. A series of tests in human participants reveal a dose-response relationship between oral intake of folate supplements and sweat folate levels, with a strong correlation in levels between sweat and serum. In addition, daily tracking of sweat folate concentrations shows clear differences between control periods without supplementation and daily intake periods. This technology creates possibilities for the routine use of sweat for precise point-of-care assessment of prenatal nutrient bioavailability.
- Open Access
- 20 May 2026
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (50) , e15913
Hot‐Film and Calorimetric Methods With Transient Heating for Measurement of High Biofluid Flow Rate
Accurate measurement of biofluid flow rate is critical for clinical diagnostics and physiological monitoring, such as in cerebrospinal fluid shunt assessment and vascular blood flow evaluation. Thermal flow sensors, particularly hot‐film and calorimetric types, are widely used in biomedical settings due to their broad dynamic range and long‐term stability. However, their performance declines at high flow rates. To overcome this drawback, we propose a transient heating method that applies a short‐duration thermal pulse and tracks the peak temperature response. This method, validated by experiments using artificial blood and vessels, significantly improves sensitivity to the flow rate change at high flow rates and reduces energy consumption. There exists an optimal heating time to maximize sensitivity to the flow rate. A contour plot of flow rate sensitivity vs. the heating time and flow rate is obtained to guide the selection of optimal heating time for different flow conditions.
- 20 May 2026
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (50) , e15913
Open AccessHot‐Film and Calorimetric Methods With Transient Heating for Measurement of High Biofluid Flow Rate
Accurate measurement of biofluid flow rate is critical for clinical diagnostics and physiological monitoring, such as in cerebrospinal fluid shunt assessment and vascular blood flow evaluation. Thermal flow sensors, particularly hot‐film and calorimetric types, are widely used in biomedical settings due to their broad dynamic range and long‐term stability. However, their performance declines at high flow rates. To overcome this drawback, we propose a transient heating method that applies a short‐duration thermal pulse and tracks the peak temperature response. This method, validated by experiments using artificial blood and vessels, significantly improves sensitivity to the flow rate change at high flow rates and reduces energy consumption. There exists an optimal heating time to maximize sensitivity to the flow rate. A contour plot of flow rate sensitivity vs. the heating time and flow rate is obtained to guide the selection of optimal heating time for different flow conditions.
- 14 May 2026
- Published by Elsevier in Engineering Fracture Mechanics
- Vol. 342
A non-affine transient network model for large-deformation fracture of polymer gels
- 14 May 2026
- Published by Elsevier in Engineering Fracture Mechanics
- Vol. 342
A non-affine transient network model for large-deformation fracture of polymer gels
- Open Access
- 23 February 2026
- Published by Elsevier in SSRN Electronic Journal
A Non-Affine Transient Network Model for Large-Deformation Fracture of Polymer Gels
A unified thermodynamic framework for polymers undergoing non-affine deformation is developed based on transient network theory. The formulation accommodates multiple classes of non-affine kinematics, allowing systematic construction of constitutive models for different mechanical problems. To address fracture behavior, the number of network segments is introduced as a key internal variable, leading to a new non-affine relation. The resulting model captures strain-hardening behavior and reproduces limiting-chain extensibility with a descriptive capability comparable to the Gent model. This provides a consistent theoretical basis for modeling large-deformation fracture in polymer gels. Phase-field fracture simulations demonstrate that the network segment number has a pronounced influence on macroscopic responses, including force–displacement behavior and crack propagation paths. The predicted fracture trajectories of perforated plate specimens agree well with experimental observations, supporting the robustness of the proposed framework. Motivated by recent experimental advances in locally tuning crosslinking states through external physical fields, finite element simulations of heterogeneous structures are further performed, demonstrating the potential of the proposed framework for gel design and for achieving synergistic enhancement of stiffness and fracture toughness.
- 23 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Non-Affine Transient Network Model for Large-Deformation Fracture of Polymer Gels
A unified thermodynamic framework for polymers undergoing non-affine deformation is developed based on transient network theory. The formulation accommodates multiple classes of non-affine kinematics, allowing systematic construction of constitutive models for different mechanical problems. To address fracture behavior, the number of network segments is introduced as a key internal variable, leading to a new non-affine relation. The resulting model captures strain-hardening behavior and reproduces limiting-chain extensibility with a descriptive capability comparable to the Gent model. This provides a consistent theoretical basis for modeling large-deformation fracture in polymer gels. Phase-field fracture simulations demonstrate that the network segment number has a pronounced influence on macroscopic responses, including force–displacement behavior and crack propagation paths. The predicted fracture trajectories of perforated plate specimens agree well with experimental observations, supporting the robustness of the proposed framework. Motivated by recent experimental advances in locally tuning crosslinking states through external physical fields, finite element simulations of heterogeneous structures are further performed, demonstrating the potential of the proposed framework for gel design and for achieving synergistic enhancement of stiffness and fracture toughness.
- Top Cited PapersOpen Access
- 18 February 2026
- Published by Springer Nature in Nature Biomedical Engineering
Shape-conformal porous frameworks for full coverage of neural organoids and high-resolution electrophysiology
Human neural organoids are essential platforms for fundamental and applied research due partly to their complex, three-dimensional neuronal circuit geometries. Standard and recently developed neural interface technologies have shortcomings in their ability to electrically characterize and control neural activity in these systems, owing to their limited accessibility to neuron populations and microelectrode densities. Here we report a shape-matched, soft, three-dimensional mesoscale framework with nearly full surface coverage to neural organoids that supports high channel count interfaces for precision electrophysiology and programmed electrical stimulation. The neural interface is designed via inverse modelling techniques and self-assembles three-dimensionally around the organoids. Three-dimensional reconstruction of neural activities allows high-resolution spatial electrophysiology to reveal network-level characteristics in neural organoids. The porous framework offers options for simultaneous fluorescence imaging, localized optogenetic neuromodulation, longitudinal monitoring, pharmacological evaluations and modelling of neural disease phenotypes, demonstrating broad applicability for studies of human-derived cortical and spinal organoids.
- 18 February 2026
- Published by Springer Nature in Nature Biomedical Engineering
Top Cited PapersOpen AccessShape-conformal porous frameworks for full coverage of neural organoids and high-resolution electrophysiology
Human neural organoids are essential platforms for fundamental and applied research due partly to their complex, three-dimensional neuronal circuit geometries. Standard and recently developed neural interface technologies have shortcomings in their ability to electrically characterize and control neural activity in these systems, owing to their limited accessibility to neuron populations and microelectrode densities. Here we report a shape-matched, soft, three-dimensional mesoscale framework with nearly full surface coverage to neural organoids that supports high channel count interfaces for precision electrophysiology and programmed electrical stimulation. The neural interface is designed via inverse modelling techniques and self-assembles three-dimensionally around the organoids. Three-dimensional reconstruction of neural activities allows high-resolution spatial electrophysiology to reveal network-level characteristics in neural organoids. The porous framework offers options for simultaneous fluorescence imaging, localized optogenetic neuromodulation, longitudinal monitoring, pharmacological evaluations and modelling of neural disease phenotypes, demonstrating broad applicability for studies of human-derived cortical and spinal organoids.
- Top Cited Papers
- 26 January 2026
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 10 (11) , 2379-2392
A filamentary soft robotic probe for multimodal in utero monitoring of fetal health
Fetal surgery offers valuable opportunities to address severe congenital disabilities, yet accurate evaluation of fetal physiological changes during in utero procedures to mitigate the risk of operative complications remains an unmet need. Conventional unimodal approaches lack predictive value, specificity and compatibility with minimally invasive interventions. Here we present a bioelectronic system featuring a multimodal, steerable filamentary probe that interfaces directly with the fetus in utero, enabling reliable and minimally invasive monitoring of various physiological parameters. Integrated soft robotic actuators ensure consistent contact through controlled navigation and force delivery, creating a gentle and secure interface with delicate fetal surfaces. In a sheep fetal surgery model, the multifunctional probe effectively monitored in utero conditions during fetoscopic surgeries, detecting fetal bradycardia, hypoxia and hypothermia, potentially informing for early intervention. Experimental results on rodents and large animal fetuses demonstrate potential for direct translation to human use. This system offers continuous, comprehensive fetal monitoring, addressing gaps in current clinical practices, and provides real-time insights during fetal surgeries.
- 26 January 2026
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 10 (11) , 2379-2392
Top Cited PapersA filamentary soft robotic probe for multimodal in utero monitoring of fetal health
Fetal surgery offers valuable opportunities to address severe congenital disabilities, yet accurate evaluation of fetal physiological changes during in utero procedures to mitigate the risk of operative complications remains an unmet need. Conventional unimodal approaches lack predictive value, specificity and compatibility with minimally invasive interventions. Here we present a bioelectronic system featuring a multimodal, steerable filamentary probe that interfaces directly with the fetus in utero, enabling reliable and minimally invasive monitoring of various physiological parameters. Integrated soft robotic actuators ensure consistent contact through controlled navigation and force delivery, creating a gentle and secure interface with delicate fetal surfaces. In a sheep fetal surgery model, the multifunctional probe effectively monitored in utero conditions during fetoscopic surgeries, detecting fetal bradycardia, hypoxia and hypothermia, potentially informing for early intervention. Experimental results on rodents and large animal fetuses demonstrate potential for direct translation to human use. This system offers continuous, comprehensive fetal monitoring, addressing gaps in current clinical practices, and provides real-time insights during fetal surgeries.
- 8 December 2025
- Published by Springer Nature in Nature Neuroscience
- Vol. 29 (1) , 234-245
Patterned wireless transcranial optogenetics generates artificial perception
Synthesizing perceivable artificial neural inputs independent of typical sensory channels remains a fundamental challenge in developing next-generation brain−machine interfaces. Establishing a minimally invasive, wirelessly effective and miniaturized platform with long-term stability is crucial for creating research methods and clinically meaningful biointerfaces capable of mediating artificial perceptual feedback. Here we demonstrate a miniaturized, fully implantable transcranial optogenetic neural stimulator designed to generate artificial perceptions by patterning large cortical ensembles wirelessly in real time. Experimentally validated numerical simulations characterized light and heat propagation, whereas neuronal responses were assessed by in vivo electrophysiology and molecular methods. Cue discrimination during operant learning demonstrated the wireless genesis of artificial percepts sensed by mice, where spatial distance across large cortical networks and sequential order-based analyses of discrimination predicted performance. These conceptual and technical advances expand understanding of artificially patterned neural activity and its perception by the brain to guide the evolution of next-generation all-optical brain−machine communication.
- 8 December 2025
- Published by Springer Nature in Nature Neuroscience
- Vol. 29 (1) , 234-245
Patterned wireless transcranial optogenetics generates artificial perception
Synthesizing perceivable artificial neural inputs independent of typical sensory channels remains a fundamental challenge in developing next-generation brain−machine interfaces. Establishing a minimally invasive, wirelessly effective and miniaturized platform with long-term stability is crucial for creating research methods and clinically meaningful biointerfaces capable of mediating artificial perceptual feedback. Here we demonstrate a miniaturized, fully implantable transcranial optogenetic neural stimulator designed to generate artificial perceptions by patterning large cortical ensembles wirelessly in real time. Experimentally validated numerical simulations characterized light and heat propagation, whereas neuronal responses were assessed by in vivo electrophysiology and molecular methods. Cue discrimination during operant learning demonstrated the wireless genesis of artificial percepts sensed by mice, where spatial distance across large cortical networks and sequential order-based analyses of discrimination predicted performance. These conceptual and technical advances expand understanding of artificially patterned neural activity and its perception by the brain to guide the evolution of next-generation all-optical brain−machine communication.
- Open Access
- 13 August 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 122 (33)
Analytical solutions for light propagation of LED
Analytical solutions of diffusion theory for light propagation in turbid media are essential for optical diagnostics and therapeutic applications, including cerebral oximetry, hemodynamic monitoring, and photostimulation. While existing solutions work reasonably well for collimated light sources—lasers and optical fibers—analytical solutions for LEDs remain missing, despite the growing use of LEDs in wearable and implantable bioelectronics. We present a method to solve the diffusion theory and derive analytical solutions for two biomedically relevant configurations: 1) surface-mounted LEDs on semi-infinite media (e.g., wearable devices) and 2) embedded LEDs in infinite media (e.g., implantable devices). Beyond a distance of 4 times the scattering length of the medium to the LED source, our analytical solutions are reasonably accurate, within 6% error for 1) and 3% for 2). This represents significant improvements over existing analytical solutions, characterized by 26% and 15% error, respectively. Using our analytical solutions, we derive tissue optical properties ( μ a and μ s ′ ) from diffuse reflectance results with <7% error, and we determine the irradiance threshold for photostimulation, aligned with experimental optogenetic activation data. Our analytical solutions are readily adaptable to various biomedical applications, offering a rigorous theoretical foundation for next-generation LED-based bioelectronics, to enable more accurate optical diagnostics and therapies in clinical applications.
- 13 August 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 122 (33)
Open AccessAnalytical solutions for light propagation of LED
Analytical solutions of diffusion theory for light propagation in turbid media are essential for optical diagnostics and therapeutic applications, including cerebral oximetry, hemodynamic monitoring, and photostimulation. While existing solutions work reasonably well for collimated light sources—lasers and optical fibers—analytical solutions for LEDs remain missing, despite the growing use of LEDs in wearable and implantable bioelectronics. We present a method to solve the diffusion theory and derive analytical solutions for two biomedically relevant configurations: 1) surface-mounted LEDs on semi-infinite media (e.g., wearable devices) and 2) embedded LEDs in infinite media (e.g., implantable devices). Beyond a distance of 4 times the scattering length of the medium to the LED source, our analytical solutions are reasonably accurate, within 6% error for 1) and 3% for 2). This represents significant improvements over existing analytical solutions, characterized by 26% and 15% error, respectively. Using our analytical solutions, we derive tissue optical properties ( μ a and μ s ′ ) from diffuse reflectance results with <7% error, and we determine the irradiance threshold for photostimulation, aligned with experimental optogenetic activation data. Our analytical solutions are readily adaptable to various biomedical applications, offering a rigorous theoretical foundation for next-generation LED-based bioelectronics, to enable more accurate optical diagnostics and therapies in clinical applications.