Tatsuhiko Miyatake
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tatsuhiko Miyatake has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Hironao Sakaki
Kansai Institute for Photon Science, National Institutes for Quantum Science and Technology (QST) 1 , 8-1-7 Umemidai, Kizugawa, Kyoto 619-0215
2 shared publications - Kota Mizushima
Department of Accelerator and Medical Physics, Institute for Quantum Medical Science, National Institutes for Quantum Science and Technology, Chiba, Japan
2 shared publications - Shunya Matsuba
Department of Accelerator and Medical Physics, Institute for Quantum Medical Science, National Institutes for Quantum Science and Technology, Chiba, Japan
2 shared publications - Tetsuya Fujimoto
Accelerator Engineering Corporation, Chiba, Japan
2 shared publications - Ye Yang
Lawrence Berkeley National Laboratory, Berkeley, CA, USA
2 shared publications - Yoshiyuki Iwata
Department of Accelerator and Medical Physics, Institute for Quantum Medical Science, National Institutes for Quantum Science and Technology, Chiba, Japan
2 shared publications
Latest Publications
- 24 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Design Study of Conical-Canted-Cosine-Theta Scanning Magnet for Heavy Ion Therapy
In heavy ion therapy, miniaturizing not only the accelerators, beamlines, or magnets but also the power supplies are crucial for downsizing the facility and reducing the installation costs. The use of combined-function superconducting magnets and discrete-cosine-theta combined X-Y scanning magnets (SCM) has already significantly reduced the gantry’s rotating radius. However, reducing the length of the beam delivery system by introducing conventional SCM significantly increases the power supply’s nominal capacity. In this study, a canted-cosine-theta (CCT) SCM is proposed to address these challenges while maintaining the same length of the beam delivery system. Its magnetic field strength is less dependent on the aperture, making it particularly suitable for SCM that requires a large aperture at the outlet. This paper describes the conceptual design of a combined X-Y SCM with conical-CCT winding and its performance.
- 24 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Design Study of Conical-Canted-Cosine-Theta Scanning Magnet for Heavy Ion Therapy
In heavy ion therapy, miniaturizing not only the accelerators, beamlines, or magnets but also the power supplies are crucial for downsizing the facility and reducing the installation costs. The use of combined-function superconducting magnets and discrete-cosine-theta combined X-Y scanning magnets (SCM) has already significantly reduced the gantry’s rotating radius. However, reducing the length of the beam delivery system by introducing conventional SCM significantly increases the power supply’s nominal capacity. In this study, a canted-cosine-theta (CCT) SCM is proposed to address these challenges while maintaining the same length of the beam delivery system. Its magnetic field strength is less dependent on the aperture, making it particularly suitable for SCM that requires a large aperture at the outlet. This paper describes the conceptual design of a combined X-Y SCM with conical-CCT winding and its performance.
- Open Access
- 1 August 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (8)
Evaluation of the spatial resolution of Gafchromic™ HD-V2 radiochromic film characterized by the modulation transfer function
The Modulation Transfer Function (MTF) characteristics of radiochromic film (RCF) dosimetry with optical systems were evaluated with an RCF, HD-V2, which is transferred with the line patterns of the resolution test chart. In the evaluation using a GT-X980 flatbed scanner, a high contrast spatial resolution with an MTF of ≥0.8 is limited to about 83.3 μm due to artifacts such as scattering of the HD-V2 transmitted light. To achieve high contrast at higher spatial frequencies, a test bench microdensitometer (TBMD) was developed, and its optical performance, dose equivalent response, and spatial resolution characteristics with MTF were evaluated. The TBMD had a minimum readout focal diameter of 13 μm, and its high contrast spatial resolution with an MTF of ≥0.8 is about 11.9 μm. The result that the optical density error increases with decreasing focal diameter in the TBMD supports our hypothesis that these errors are based on the non-uniformity of the shading and surface roughness of the HD-V2 active layer monomers.
- 1 August 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (8)
Open AccessEvaluation of the spatial resolution of Gafchromic™ HD-V2 radiochromic film characterized by the modulation transfer function
The Modulation Transfer Function (MTF) characteristics of radiochromic film (RCF) dosimetry with optical systems were evaluated with an RCF, HD-V2, which is transferred with the line patterns of the resolution test chart. In the evaluation using a GT-X980 flatbed scanner, a high contrast spatial resolution with an MTF of ≥0.8 is limited to about 83.3 μm due to artifacts such as scattering of the HD-V2 transmitted light. To achieve high contrast at higher spatial frequencies, a test bench microdensitometer (TBMD) was developed, and its optical performance, dose equivalent response, and spatial resolution characteristics with MTF were evaluated. The TBMD had a minimum readout focal diameter of 13 μm, and its high contrast spatial resolution with an MTF of ≥0.8 is about 11.9 μm. The result that the optical density error increases with decreasing focal diameter in the TBMD supports our hypothesis that these errors are based on the non-uniformity of the shading and surface roughness of the HD-V2 active layer monomers.
- Open Access
- 1 May 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 999
Denoising application for electron spectrometer in laser-driven ion acceleration using a Simulation-supervised Learning based CDAE
- 1 May 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 999
Open AccessDenoising application for electron spectrometer in laser-driven ion acceleration using a Simulation-supervised Learning based CDAE