XFXikun Fu

Xikun Fu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xikun Fu has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Transient Stability Enhancement of Multi-Inverter Microgrids

    by Jingxi Yang, Chi K. Tse, Meng Huang, Dong Liu, Xikun Fu, Chao Charles Liu

    Large-scale distributed renewable energy sources (RESs) are entering the power system through grid-forming and grid-following inverters (GFMIs and GFLIs). These inverters can cluster together to create an islanded microgrid that optimizes the use of RESs. However, the microgrid may lose synchronization during a temporary short-circuit fault. It has been observed that the critical fault clearing time can increase if GFLIs inject a significant amount of reactive power or if GFMIs operate at slightly higher cutoff frequencies in their low-pass filters. This phenomenon is related to a specific hidden periodic orbit and the relative region of the stable equilibrium point's (SEP's) basin of attraction. Due to the presence of the aforementioned hidden periodic orbit, the phase-locked loop is able to operate normally during the fault, which effectively ensures the synchronization stability for the post-fault system. The sustainability of this hidden periodic orbit depends on the appropriate injection of reactive power by GFLIs. Moreover, increasing the cutoff frequencies of GFMIs leads to a homoclinic bifurcation, which enlarges the SEP's basin of attraction and guarantees successful resynchronization of the inverters after the fault is cleared. Simulations and experiments have confirmed these findings.


  • Comparison of Homoclinic Bifurcations Between Grid-Following and Grid-Forming Converters

    by Jingxi Yang, Chi K. Tse, Meng Huang, Dong Liu, Chao Charles Liu, Xikun Fu

    A second-order model is developed to describe the essential behavior of the grid-following converter (GFLC) and the grid-forming converter (GFMC) for studying the synchronization characteristics of grid-connected converter systems. In this article, a general set of criteria in terms of the manifolds and saddle quantity is derived for studying the homoclinic bifurcation behavior of GFLCs and GFMCs. It is shown that three unstable periodic orbits and two homoclinic bifurcations may exist for the GFLC, while only one stable periodic orbit and one homoclinic bifurcation may exist for the GFMC. It is also found that after the onset of the first homoclinic bifurcation, the stable equilibrium point (SEP) is surrounded by the stable manifolds of the unstable equilibrium point (UEP), which forms the SEP's basin of attraction, for both GFLCs and GFMCs. In this case, the converters may lose their synchronization if the trajectory crosses over the UEP. Therefore, system parameters should be designed to avoid the onset of the aforementioned bifurcation so that the SEP's basin of attraction can be significantly enlarged to contain the UEP. As a result, the GFLC or GFMC can eventually resynchronize with the grid even when its trajectory passes the UEP. Finally, experimental results are provided to verify these theoretical findings.


  • Synchronization Stability of Grid-Following VSC Considering Interactions of Inner Current Loop and Parallel-Connected Converters

    by Xikun Fu, Meng Huang, Chi K. Tse, Jingxi Yang, Yangjian Ling, Xiaoming Zha

    In the grid-following (GFL) voltage source converter (VSC), the synchronization process of phase-locked loop (PLL) can be seriously affected by the interactions from the inner current loop and other parallel-connected VSCs. In this paper, we focus on the influences of these interactions on the synchronization stability of GFL-VSC. Firstly, these interactions are classified into static and dynamic interactions by the mechanism of how they affect the dynamic of PLL. Then, their influence on the synchronization stability is estimated based on a novel Lyapunov stability criterion, which is derived from the extended invariance principle. On this basis, in terms of the physical mechanism, we reveal how the VSC exhibits the non-asymptotic synchronization (i.e., limit cycles) and cascading synchronization instability. In addition, we get the maximum range of static and dynamic interactions that the VSC endure, which can provide the practical design guidance for the VSC. Finally, simulations and experiments are performed to verify the theoretical findings.


  • Cascading Synchronization Instability in Multi-VSC Grid-Connected System

    by Xikun Fu, Meng Huang, Shangzhi Pan, Xiaoming Zha

    In this letter, a cascading synchronization instability phenomenon is reported in a multi-voltage-source-converter (VSC) grid. By adopting the equal area criterion, it is revealed that during the fault transient, there is static interaction that increases equivalent mechanical power for the original stable-operating VSC. Due to the fast power angle swing of the unstable VSC, there is nonnegligible dynamic interaction, which may decrease its synchronization stability margin. The effect of system parameters on synchronization stability is studied, and the simulation and experimental results verify the analysis.


  • Homoclinic Bifurcation of a Grid-Forming Voltage Source Converter

    by Jingxi Yang, Chi K. Tse, Meng Huang, Xikun Fu

    Under transient disturbance, the grid-forming voltage-source converter may lose its synchronization with the grid, inducing sustained low-frequency oscillation in instantaneous power, current, and phase angle. The physical origin of such oscillations is found to be a homoclinic bifurcation in this article. Before the system runs into a homoclinic bifurcation, a stable equilibrium point (SEP) and a stable periodic orbit coexist. When a large transient disturbance is applied, the system exhibits a periodic orbit, which manifests itself as low-frequency oscillation. Moreover, after the homoclinic bifurcation, the periodic orbit subsides, and only a single attractor, the SEP, exists in the phase space. In this case, the grid-forming converter is able to resynchronize with the grid even under transient disturbances. Bifurcation diagrams are derived as the boundaries of stable operation in the parameter space, which serve as practical design guidelines to avoid sustained oscillations. Cycle-by-cycle simulations and laboratory experiments are performed to verify the analytical findings.


  • Hamilton-Based Stability Criterion and Attraction Region Estimation for Grid-Tied Inverters Under Large-Signal Disturbances

    by Zhen Tian, Yingjie Tang, Xiaoming Zha, Jianjun Sun, Meng Huang, Xikun Fu, Fei Liu

    As the crucial interface of renewable energy integration, the stable operation of power converters under grid faults and external disturbances has become much more important. However, synchronization instability of grid-tied inverters has been found caused by the phase-locked loop (PLL) under some critical operating conditions, such as the grid voltage sag, current surge, and transmission line faults. Due to the strong nonlinearity, transient stability analysis of inverters with PLL becomes much more complicated under large-signal perturbations and weak grid conditions. In this article, the large-signal synchronization stability of grid-tied inverters is investigated from the energy perspective. Based on the structural resemblance between the PLL and synchronous generator, the energy function is constructed to establish a port-Hamiltonian model for the grid-tied inverter. For the nonlinear inverter system, an explicit Hamilton-based stability criterion is developed for grid-tied converters according to the concept of dissipativity and LaSalle’s theorem. Moreover, the analytical stability boundary is acquired based on the proposed stability criterion and attraction region estimation, covering both controller parameters and grid parameters. To verify the effectiveness of the proposed analysis approach, extensive simulation and experimental results are presented. Compared with the conventional large-signal methods, the proposed Hamilton-based approach has explicit physical meaning and high accuracy.


  • Clustering-Based Modeling and Interaction Analysis of Multiple Differently Parameterized Grid-Side Inverters in PMSG Wind Turbines

    by Shuhan Liao, Yandong Chen, Meng Huang, Xikun Fu, Xiaoming Zha, Lei Wang, An Luo, Josep M. Guerrero

    Interactions of identical inverters in weak grids have received wide attentions. However, in a practical wind farm, parameters of grid-side inverters and lengths of collecting lines are not completely the same. In this case, a multi-inverter system is not symmetric, and thus the interaction mechanism could be more complicated than that of identical inverters. To investigate the interaction mechanism of differently parameterized inverters, this paper proposes a clustering-based modeling method, in which inverters with identical parameters are classified as one group. The clustering-based model allows for efficient stability assessment using three low-order transfer function matrices, instead of a full-order dynamic model. The root locus analysis is applied in the clustering-based model for stability analysis. Results show that the interconnection of distinct groups of inverters deteriorates common current stability, but has no impact on interactive current stability. The simulation and rtlab-based experimental results validate the effectiveness of the proposed model and the interaction mechanism of differently parameterized inverters.


  • Top Cited Papers

    Large-Signal Stability of Grid-Forming and Grid-Following Controls in Voltage Source Converter: A Comparative Study

    by Xikun Fu, Jianjun Sun, Meng Huang, Zhen Tian, Han Yan, Herbert Ho-Ching Iu, Pan Hu, Xiaoming Zha

    The grid-forming and grid-following controls are adopted in three-phase voltage source converters according to different grid conditions. However, the basic operation principle of the two kinds of control are different and will leads to the instability of the grid-connected system through various paths. In this paper, the energy function model of the grid-forming and grid-following controlled converters are established and compared in detail. The influence of system parameters is studied, and the large-signal stability boundaries are derived through a general method. Moreover, compared to the grid-forming controlled converter, the grid-following converter will lose stability by exhibiting a varying damping coefficient transient. The equivalent damping coefficient can be used as a criterion of whether the grid-forming/following control is suitable for the weak/strong grid condition. The simulation and experiment results show the difference of the transient process and validate the control criterion for different grid strength under large-signal disturbance.