Chiara Di Vece
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chiara Di Vece has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Danail Stoyanov
Department of Computer Science and UCL Hawkes Institute, University College London, London, UK
4 shared publications- Danail Stoyanov
University College London
4 shared publications Francisco Vasconcelos
Department of Computer Science and UCL Hawkes Institute, University College London, London, UK
4 shared publicationsRaffaele Napolitano
Fetal Medicine Unit, Women’s Health Division, UCLH NHS Foundation Trust and Elizabeth Garrett Anderson, Institute for Women’s Health, University College London, London, UK
4 shared publicationsBrian Dromey
Department of Computer Science and UCL Hawkes Institute, University College London, London, UK
3 shared publicationsDafna Ben Bashat
Tel Aviv Sourasky Medical Center, Sagol Brain Institute, Tel Aviv, Israel
3 shared publications
Latest Publications
- Open Access
- 14 April 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
A multicentre benchmark dataset for comprehensive landmark-based fetal ultrasound biometry
Accurate fetal growth assessment from ultrasound (US) relies on precise biometry measured by manually identifying anatomical landmarks in standard planes. Manual annotation of landmarks is time-consuming, operator-dependent, and sensitive to variability across scanners and sites, limiting the reproducibility of automated approaches. There is a need for multi-source, annotated datasets to develop artificial intelligence-assisted fetal growth assessment methods. To address this bottleneck, we present an open-access, multicentre benchmark dataset of fetal US images with expert anatomical landmark annotations for clinically used fetal biometric measurements. These measurements include head biparietal and occipitofrontal diameters, abdominal transverse and anteroposterior diameters, and femoral length. The dataset contains 4,513 de-identified US images from 1,904 subjects acquired at four clinical sites using seven different US devices. We provide subject-disjoint train/test splits, evaluation code, and baseline results to enable fair and reproducible comparisons of methods. Using an automated landmark-based fetal biometry model on pre-selected standard planes, we quantify domain shift and show that training and evaluation confined to a single centre can overestimate performance relative to multicentre testing. To the best of our knowledge, this is the first publicly available multicentre, multi-device, landmark-annotated dataset that covers all primary fetal biometry measures, providing a robust benchmark for studying domain shift and multicentre generalisation and enabling more reliable AI-assisted fetal biometry across centres. All data and annotations are available on the UCL Research Data Repository . Training code and evaluation pipelines are available at https://github.com/surgical-vision/Multicentre-Fetal-Biometry.git .
- 14 April 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessA multicentre benchmark dataset for comprehensive landmark-based fetal ultrasound biometry
Accurate fetal growth assessment from ultrasound (US) relies on precise biometry measured by manually identifying anatomical landmarks in standard planes. Manual annotation of landmarks is time-consuming, operator-dependent, and sensitive to variability across scanners and sites, limiting the reproducibility of automated approaches. There is a need for multi-source, annotated datasets to develop artificial intelligence-assisted fetal growth assessment methods. To address this bottleneck, we present an open-access, multicentre benchmark dataset of fetal US images with expert anatomical landmark annotations for clinically used fetal biometric measurements. These measurements include head biparietal and occipitofrontal diameters, abdominal transverse and anteroposterior diameters, and femoral length. The dataset contains 4,513 de-identified US images from 1,904 subjects acquired at four clinical sites using seven different US devices. We provide subject-disjoint train/test splits, evaluation code, and baseline results to enable fair and reproducible comparisons of methods. Using an automated landmark-based fetal biometry model on pre-selected standard planes, we quantify domain shift and show that training and evaluation confined to a single centre can overestimate performance relative to multicentre testing. To the best of our knowledge, this is the first publicly available multicentre, multi-device, landmark-annotated dataset that covers all primary fetal biometry measures, providing a robust benchmark for studying domain shift and multicentre generalisation and enabling more reliable AI-assisted fetal biometry across centres. All data and annotations are available on the UCL Research Data Repository . Training code and evaluation pipelines are available at https://github.com/surgical-vision/Multicentre-Fetal-Biometry.git .
- Open Access
- 12 January 2026
- Published by Springer Nature in Research Square
A multi-centre, multi-device benchmark dataset for landmark-based comprehensive fetal biometry
Accurate fetal growth assessment from ultrasound (US) relies on precise biometry measured by manually identifying anatomical landmarks in standard planes. Manual landmarking is time-consuming, operator-dependent, and sensitive to variability across scanners and sites, limiting the reproducibility of automated approaches. There is a need for multi-source annotated datasets to develop artificial intelligence-assisted fetal growth assessment methods. To address this bottleneck, we present an open, multi-centre, multi-device benchmark dataset of fetal US images with expert anatomical landmark annotations for clinically used fetal biometric measurements. These measurements include head bi-parietal and occipito-frontal diameters, abdominal transverse and antero-posterior diameters, and femoral length. The dataset contains 4,513 de-identified US images from 1,904 subjects acquired at three clinical sites using seven different US devices. We provide standardised, subject-disjoint train/test splits, evaluation code, and baseline results to enable fair and reproducible comparison of methods. Using an automatic biometry model, we quantify domain shift and demonstrate that training and evaluation confined to a single centre substantially overestimate performance relative to multi-centre testing. To the best of our knowledge, this is the first publicly available multi-centre, multi-device, landmark-annotated dataset that covers all primary fetal biometry measures, providing a robust benchmark for domain adaptation and multi-centre generalisation in fetal biometry and enabling more reliable AI-assisted fetal growth assessment across centres. All data, annotations, training code, and evaluation pipelines are made publicly available at https://github.com/surgical-vision/Multicentre-Fetal-Biometry.git.
- 12 January 2026
- Published by Springer Nature in Research Square
Open AccessA multi-centre, multi-device benchmark dataset for landmark-based comprehensive fetal biometry
Accurate fetal growth assessment from ultrasound (US) relies on precise biometry measured by manually identifying anatomical landmarks in standard planes. Manual landmarking is time-consuming, operator-dependent, and sensitive to variability across scanners and sites, limiting the reproducibility of automated approaches. There is a need for multi-source annotated datasets to develop artificial intelligence-assisted fetal growth assessment methods. To address this bottleneck, we present an open, multi-centre, multi-device benchmark dataset of fetal US images with expert anatomical landmark annotations for clinically used fetal biometric measurements. These measurements include head bi-parietal and occipito-frontal diameters, abdominal transverse and antero-posterior diameters, and femoral length. The dataset contains 4,513 de-identified US images from 1,904 subjects acquired at three clinical sites using seven different US devices. We provide standardised, subject-disjoint train/test splits, evaluation code, and baseline results to enable fair and reproducible comparison of methods. Using an automatic biometry model, we quantify domain shift and demonstrate that training and evaluation confined to a single centre substantially overestimate performance relative to multi-centre testing. To the best of our knowledge, this is the first publicly available multi-centre, multi-device, landmark-annotated dataset that covers all primary fetal biometry measures, providing a robust benchmark for domain adaptation and multi-centre generalisation in fetal biometry and enabling more reliable AI-assisted fetal growth assessment across centres. All data, annotations, training code, and evaluation pipelines are made publicly available at https://github.com/surgical-vision/Multicentre-Fetal-Biometry.git.
- Open Access
A multi-centre, multi-device benchmark dataset for landmark-based comprehensive fetal biometry
Accurate fetal growth assessment from ultrasound (US) relies on precise biometry measured by manually identifying anatomical landmarks in standard planes. Manual landmarking is time-consuming, operator-dependent, and sensitive to variability across scanners and sites, limiting the reproducibility of automated approaches. There is a need for multi-source annotated datasets to develop artificial intelligence-assisted fetal growth assessment methods. To address this bottleneck, we present an open, multi-centre, multi-device benchmark dataset of fetal US images with expert anatomical landmark annotations for clinically used fetal biometric measurements. These measurements include head bi-parietal and occipito-frontal diameters, abdominal transverse and antero-posterior diameters, and femoral length. The dataset comprises 4,513 de-identified US images from 1,904 subjects acquired at three clinical sites using seven different US devices. We provide standardised, subject-disjoint train/test splits, evaluation code, and baseline results to enable fair and reproducible comparison of methods. Using an automatic biometry model, we quantify domain shift and demonstrate that training and evaluation confined to a single centre substantially overestimate performance relative to multi-centre testing. To the best of our knowledge, this is the first publicly available multi-centre, multi-device, landmark-annotated dataset that covers all primary fetal biometry measures, providing a robust benchmark for domain adaptation and multi-centre generalisation in fetal biometry and enabling more reliable AI-assisted fetal growth assessment across centres. All data, annotations, training code, and evaluation pipelines are made publicly available.
Open AccessA multi-centre, multi-device benchmark dataset for landmark-based comprehensive fetal biometry
Accurate fetal growth assessment from ultrasound (US) relies on precise biometry measured by manually identifying anatomical landmarks in standard planes. Manual landmarking is time-consuming, operator-dependent, and sensitive to variability across scanners and sites, limiting the reproducibility of automated approaches. There is a need for multi-source annotated datasets to develop artificial intelligence-assisted fetal growth assessment methods. To address this bottleneck, we present an open, multi-centre, multi-device benchmark dataset of fetal US images with expert anatomical landmark annotations for clinically used fetal biometric measurements. These measurements include head bi-parietal and occipito-frontal diameters, abdominal transverse and antero-posterior diameters, and femoral length. The dataset comprises 4,513 de-identified US images from 1,904 subjects acquired at three clinical sites using seven different US devices. We provide standardised, subject-disjoint train/test splits, evaluation code, and baseline results to enable fair and reproducible comparison of methods. Using an automatic biometry model, we quantify domain shift and demonstrate that training and evaluation confined to a single centre substantially overestimate performance relative to multi-centre testing. To the best of our knowledge, this is the first publicly available multi-centre, multi-device, landmark-annotated dataset that covers all primary fetal biometry measures, providing a robust benchmark for domain adaptation and multi-centre generalisation in fetal biometry and enabling more reliable AI-assisted fetal growth assessment across centres. All data, annotations, training code, and evaluation pipelines are made publicly available.
- 12 May 2025
- Published by Springer Nature
- p. 120-137
Mismatched: Evaluating the Limits of Image Matching Approaches and Benchmarks
- 12 May 2025
- Published by Springer Nature
- p. 120-137
Mismatched: Evaluating the Limits of Image Matching Approaches and Benchmarks
- 11 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (4) , 3174-3181
Robotic Arm Platform for Multi-View Image Acquisition and 3D Reconstruction in Minimally Invasive Surgery
Minimally invasive surgery (MIS) offers significant benefits, such as reduced recovery time and minimised patient trauma, but poses challenges in visibility and access, making accurate 3D reconstruction a significant tool in surgical planning and navigation. This work introduces a robotic arm platform for efficient multi-view image acquisition and precise 3D reconstruction in MIS settings. We adapted a laparoscope to a robotic arm and captured ex-vivo images of several ovine organs across varying lighting conditions (operating room and laparoscopic) and trajectories (spherical and laparoscopic). We employed recently released learning-based feature matchers combined with COLMAP to produce our reconstructions. The reconstructions were evaluated against high-precision laser scans for quantitative evaluation. Our results show that whilst reconstructions suffer most under realistic MIS lighting and trajectory, two matching methods achieve close to sub-millimetre accuracy with 0.80 and 0.76 mm Chamfer distances and 1.06 and 0.98 mm RMSEs for ALIKED and GIM respectively. Our best reconstruction results occur with operating room lighting and spherical trajectories. Our robotic platform provides a tool for controlled, repeatable multi-view data acquisition for 3D generation in MIS environments, which can lead to new datasets necessary for novel learning-based surgical models.
- 11 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (4) , 3174-3181
Robotic Arm Platform for Multi-View Image Acquisition and 3D Reconstruction in Minimally Invasive Surgery
Minimally invasive surgery (MIS) offers significant benefits, such as reduced recovery time and minimised patient trauma, but poses challenges in visibility and access, making accurate 3D reconstruction a significant tool in surgical planning and navigation. This work introduces a robotic arm platform for efficient multi-view image acquisition and precise 3D reconstruction in MIS settings. We adapted a laparoscope to a robotic arm and captured ex-vivo images of several ovine organs across varying lighting conditions (operating room and laparoscopic) and trajectories (spherical and laparoscopic). We employed recently released learning-based feature matchers combined with COLMAP to produce our reconstructions. The reconstructions were evaluated against high-precision laser scans for quantitative evaluation. Our results show that whilst reconstructions suffer most under realistic MIS lighting and trajectory, two matching methods achieve close to sub-millimetre accuracy with 0.80 and 0.76 mm Chamfer distances and 1.06 and 0.98 mm RMSEs for ALIKED and GIM respectively. Our best reconstruction results occur with operating room lighting and spherical trajectories. Our robotic platform provides a tool for controlled, repeatable multi-view data acquisition for 3D generation in MIS environments, which can lead to new datasets necessary for novel learning-based surgical models.
- Open Access
Measuring proximity to standard planes during fetal brain ultrasound scanning
This paper introduces a novel pipeline designed to bring ultrasound (US) plane pose estimation closer to clinical use for more effective navigation to the standard planes (SPs) in the fetal brain. We propose a semi-supervised segmentation model utilizing both labeled SPs and unlabeled 3D US volume slices. Our model enables reliable segmentation across a diverse set of fetal brain images. Furthermore, the model incorporates a classification mechanism to identify the fetal brain precisely. Our model not only filters out frames lacking the brain but also generates masks for those containing it, enhancing the relevance of plane pose regression in clinical settings. We focus on fetal brain navigation from 2D ultrasound (US) video analysis and combine this model with a US plane pose regression network to provide sensorless proximity detection to SPs and non-SPs planes; we emphasize the importance of proximity detection to SPs for guiding sonographers, offering a substantial advantage over traditional methods by allowing earlier and more precise adjustments during scanning. We demonstrate the practical applicability of our approach through validation on real fetal scan videos obtained from sonographers of varying expertise levels. Our findings demonstrate the potential of our approach to complement existing fetal US technologies and advance prenatal diagnostic practices.
Open AccessMeasuring proximity to standard planes during fetal brain ultrasound scanning
This paper introduces a novel pipeline designed to bring ultrasound (US) plane pose estimation closer to clinical use for more effective navigation to the standard planes (SPs) in the fetal brain. We propose a semi-supervised segmentation model utilizing both labeled SPs and unlabeled 3D US volume slices. Our model enables reliable segmentation across a diverse set of fetal brain images. Furthermore, the model incorporates a classification mechanism to identify the fetal brain precisely. Our model not only filters out frames lacking the brain but also generates masks for those containing it, enhancing the relevance of plane pose regression in clinical settings. We focus on fetal brain navigation from 2D ultrasound (US) video analysis and combine this model with a US plane pose regression network to provide sensorless proximity detection to SPs and non-SPs planes; we emphasize the importance of proximity detection to SPs for guiding sonographers, offering a substantial advantage over traditional methods by allowing earlier and more precise adjustments during scanning. We demonstrate the practical applicability of our approach through validation on real fetal scan videos obtained from sonographers of varying expertise levels. Our findings demonstrate the potential of our approach to complement existing fetal US technologies and advance prenatal diagnostic practices.
- Open Access
- 31 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (1) , 41-52
Ultrasound Plane Pose Regression: Assessing Generalized Pose Coordinates in the Fetal Brain
In obstetric ultrasound (US) scanning, the learner’s ability to mentally build a three-dimensional (3D) map of the fetus from a two-dimensional (2D) US image represents a significant challenge in skill acquisition. We aim to build a US plane localization system for 3D visualization, training, and guidance without integrating additional sensors. This work builds on top of our previous work, which predicts the six-dimensional (6D) pose of arbitrarily oriented US planes slicing the fetal brain with respect to a normalized reference frame using a convolutional neural network (CNN) regression network. Here, we analyze in detail the assumptions of the normalized fetal brain reference frame and quantify its accuracy with respect to the acquisition of transventricular (TV) standard plane (SP) for fetal biometry. We investigate the impact of registration quality in the training and testing data and its subsequent effect on trained models. Finally, we introduce data augmentations and larger training sets that improve the results of our previous work, achieving median errors of $2.97~mm$ and 6.63° for translation and rotation, respectively.
- 31 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (1) , 41-52
Open AccessUltrasound Plane Pose Regression: Assessing Generalized Pose Coordinates in the Fetal Brain
In obstetric ultrasound (US) scanning, the learner’s ability to mentally build a three-dimensional (3D) map of the fetus from a two-dimensional (2D) US image represents a significant challenge in skill acquisition. We aim to build a US plane localization system for 3D visualization, training, and guidance without integrating additional sensors. This work builds on top of our previous work, which predicts the six-dimensional (6D) pose of arbitrarily oriented US planes slicing the fetal brain with respect to a normalized reference frame using a convolutional neural network (CNN) regression network. Here, we analyze in detail the assumptions of the normalized fetal brain reference frame and quantify its accuracy with respect to the acquisition of transventricular (TV) standard plane (SP) for fetal biometry. We investigate the impact of registration quality in the training and testing data and its subsequent effect on trained models. Finally, we introduce data augmentations and larger training sets that improve the results of our previous work, achieving median errors of $2.97~mm$ and 6.63° for translation and rotation, respectively.
- Open Access
- 30 April 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 17 (5) , 833-839
Deep learning-based plane pose regression in obstetric ultrasound
Purpose: In obstetric ultrasound (US) scanning, the learner’s ability to mentally build a three-dimensional (3D) map of the fetus from a two-dimensional (2D) US image represents a major challenge in skill acquisition. We aim to build a US plane localisation system for 3D visualisation, training, and guidance without integrating additional sensors. Methods: We propose a regression convolutional neural network (CNN) using image features to estimate the six-dimensional pose of arbitrarily oriented US planes relative to the fetal brain centre. The network was trained on synthetic images acquired from phantom 3D US volumes and fine-tuned on real scans. Training data was generated by slicing US volumes into imaging planes in Unity at random coordinates and more densely around the standard transventricular (TV) plane. Results: With phantom data, the median errors are 0.90 mm/1.17 $$^\circ $$ and 0.44 mm/1.21 $$^\circ $$ for random planes and planes close to the TV one, respectively. With real data, using a different fetus with the same gestational age (GA), these errors are 11.84 mm/25.17 $$^\circ $$ . The average inference time is 2.97 ms per plane. Conclusion: The proposed network reliably localises US planes within the fetal brain in phantom data and successfully generalises pose regression for an unseen fetal brain from a similar GA as in training. Future development will expand the prediction to volumes of the whole fetus and assess its potential for vision-based, freehand US-assisted navigation when acquiring standard fetal planes.- 30 April 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 17 (5) , 833-839
Open AccessDeep learning-based plane pose regression in obstetric ultrasound
Purpose: In obstetric ultrasound (US) scanning, the learner’s ability to mentally build a three-dimensional (3D) map of the fetus from a two-dimensional (2D) US image represents a major challenge in skill acquisition. We aim to build a US plane localisation system for 3D visualisation, training, and guidance without integrating additional sensors. Methods: We propose a regression convolutional neural network (CNN) using image features to estimate the six-dimensional pose of arbitrarily oriented US planes relative to the fetal brain centre. The network was trained on synthetic images acquired from phantom 3D US volumes and fine-tuned on real scans. Training data was generated by slicing US volumes into imaging planes in Unity at random coordinates and more densely around the standard transventricular (TV) plane. Results: With phantom data, the median errors are 0.90 mm/1.17 $$^\circ $$ and 0.44 mm/1.21 $$^\circ $$ for random planes and planes close to the TV one, respectively. With real data, using a different fetus with the same gestational age (GA), these errors are 11.84 mm/25.17 $$^\circ $$ . The average inference time is 2.97 ms per plane. Conclusion: The proposed network reliably localises US planes within the fetal brain in phantom data and successfully generalises pose regression for an unseen fetal brain from a similar GA as in training. Future development will expand the prediction to volumes of the whole fetus and assess its potential for vision-based, freehand US-assisted navigation when acquiring standard fetal planes. - 16 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (3) , 6061-6067
Position-Based Dynamics Simulator of Brain Deformations for Path Planning and Intra-Operative Control in Keyhole Neurosurgery
Many tasks in robot-assisted surgery require planning and controlling manipulators’ motions that interact with highly deformable objects. This study proposes a realistic, time-bounded simulator based on Position-based Dynamics (PBD) simulation that mocks brain deformations due to catheter insertion for pre-operative path planning and intra-operative guidance in keyhole surgical procedures. It maximizes the probability of success by accounting for uncertainty in deformation models, noisy sensing, and unpredictable actuation. The PBD deformation parameters were initialized on a parallelepiped-shaped simulated phantom to obtain a reasonable starting guess for the brain white matter. They were calibrated by comparing the obtained displacements with deformation data for catheter insertion in a composite hydrogel phantom. Knowing the gray matter brain structures’ different behaviors, the parameters were fine-tuned to obtain a generalized human brain model. The brain structures’ average displacement was compared with values in the literature. The simulator's numerical model uses a novel approach with respect to the literature, and it has proved to be a close match with real brain deformations through validation using recorded deformation data of in-vivo animal trials with a mean mismatch of 4.73 $\pm$ 2.15%. The stability, accuracy, and real-time performance make this model suitable for creating a dynamic environment for KN path planning, pre-operative path planning, and intra-operative guidance.
- 16 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (3) , 6061-6067
Position-Based Dynamics Simulator of Brain Deformations for Path Planning and Intra-Operative Control in Keyhole Neurosurgery
Many tasks in robot-assisted surgery require planning and controlling manipulators’ motions that interact with highly deformable objects. This study proposes a realistic, time-bounded simulator based on Position-based Dynamics (PBD) simulation that mocks brain deformations due to catheter insertion for pre-operative path planning and intra-operative guidance in keyhole surgical procedures. It maximizes the probability of success by accounting for uncertainty in deformation models, noisy sensing, and unpredictable actuation. The PBD deformation parameters were initialized on a parallelepiped-shaped simulated phantom to obtain a reasonable starting guess for the brain white matter. They were calibrated by comparing the obtained displacements with deformation data for catheter insertion in a composite hydrogel phantom. Knowing the gray matter brain structures’ different behaviors, the parameters were fine-tuned to obtain a generalized human brain model. The brain structures’ average displacement was compared with values in the literature. The simulator's numerical model uses a novel approach with respect to the literature, and it has proved to be a close match with real brain deformations through validation using recorded deformation data of in-vivo animal trials with a mean mismatch of 4.73 $\pm$ 2.15%. The stability, accuracy, and real-time performance make this model suitable for creating a dynamic environment for KN path planning, pre-operative path planning, and intra-operative guidance.
- Open Access
- 12 March 2021
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 16 (4) , 639-647
Psychomotor skills development for Veress needle placement using a virtual reality and haptics-based simulator
Purpose: Veress needle (VN) insertion, if not correctly performed, could cause severe injuries to intra-abdominal organs and vessels. Therefore, cognitive and psychomotor skills training is needed. Virtual reality (VR) and haptic technologies have the potential to offer realistic simulations.Methods: We developed a novel VR and haptic surgical simulator for VN insertion to teach trainees how to correctly puncture the abdominal wall, experiencing realistic tactile sensations throughout the simulation. The simulator allows for both procedural and realistic training. We released two different versions: the first using the OpenHaptics $$^{\text {TM}}$$ (OH) Toolkit and the second exploiting CHAI3D. We evaluated the learning effect using different performance indexes (time to perform the procedure, error in insertion angle, number of undesired contacts with organs) in an insertion task for both experienced urologists and students.Results: A general improvement of the chosen performance indexes was registered in the second repetition of the task for both groups. From the questionnaires, the simulator leveraging OH provides the trainee with a more precise haptic feedback, whereas the one exploiting CHAI3D allows them to perform the procedure more easily thanks to the better visualization of the virtual environment. The results proved that the participants appreciated both implementations, and the System Usability Scale (SUS) test resulted in a “good” usability.Conclusion: The haptics-based and VR simulator has shown the potential to be an important resource for the basic urological training in obtaining the pneumoperitoneum and improving the acquisition of the necessary psychomotor skills, allowing for extended and more effective training without compromising patient safety.- 12 March 2021
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 16 (4) , 639-647
Open AccessPsychomotor skills development for Veress needle placement using a virtual reality and haptics-based simulator
Purpose: Veress needle (VN) insertion, if not correctly performed, could cause severe injuries to intra-abdominal organs and vessels. Therefore, cognitive and psychomotor skills training is needed. Virtual reality (VR) and haptic technologies have the potential to offer realistic simulations.Methods: We developed a novel VR and haptic surgical simulator for VN insertion to teach trainees how to correctly puncture the abdominal wall, experiencing realistic tactile sensations throughout the simulation. The simulator allows for both procedural and realistic training. We released two different versions: the first using the OpenHaptics $$^{\text {TM}}$$ (OH) Toolkit and the second exploiting CHAI3D. We evaluated the learning effect using different performance indexes (time to perform the procedure, error in insertion angle, number of undesired contacts with organs) in an insertion task for both experienced urologists and students.Results: A general improvement of the chosen performance indexes was registered in the second repetition of the task for both groups. From the questionnaires, the simulator leveraging OH provides the trainee with a more precise haptic feedback, whereas the one exploiting CHAI3D allows them to perform the procedure more easily thanks to the better visualization of the virtual environment. The results proved that the participants appreciated both implementations, and the System Usability Scale (SUS) test resulted in a “good” usability.Conclusion: The haptics-based and VR simulator has shown the potential to be an important resource for the basic urological training in obtaining the pneumoperitoneum and improving the acquisition of the necessary psychomotor skills, allowing for extended and more effective training without compromising patient safety.