THThomas John Howe

Thomas John Howe

*This is an algorithmically generated author record based on publicly available information.

Thomas John Howe has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Bioactive Glass Dressings for Infected Wounds: A Systematic Review

    by Nandesh C. Patel, Thomas J. Howe, Henry A. Claireaux, Julian R. Jones, Arul Ramasamy

    Wounds pose a clinical challenge due to their susceptibility to infection and complex healing environments. Wound infection with multi‐drug‐resistant bacteria increases the mortality and morbidity, with new strategies needed to treat them. Bioactive glasses are biodegradable glasses that interact with biological systems by releasing ions such as Na + , Ca 2+ and borate. They are emerging as promising adjuncts in managing infected wounds. This review aims to synthesise the current evidence on the role of bioactive glass in infected wounds. This systematic review was reported as per PRISMA 2020 and PRISMA‐S. Medline, EMBASE and CINAHL Complete were searched using a research librarian designed strategy. In vivo studies were screened in duplicate by two blinded authors and quality was assessed with no limitation on study type. Heterogeneity precluded meta‐analysis. Twenty in vivo animal studies were included. Most studies investigated mesoporous or dense nanoparticles ( n = 17) in murine models ( n = 20) infected with S. aureus . Overall, bioactive glass preparations had faster wound healing compared to comparators by day 14. They consistently reduced bacterial burden in infected animal wound models, with faster and more complete remodelling resulting in better structural and functional skin regeneration. Despite promising results, certainty of evidence was low. This systematic review demonstrates the promise of bioactive glass wound dressings for infected wounds. Findings complement those showing benefit in diabetic chronic wound healing in addition to bone and joint infection. Further research is required to compare bioactive glass dressings to standard‐of‐care dressings to pave the way for first‐in‐human trials to translate these biomaterials for clinical use.

  • Open Access

    Assessment of proprietary and improvised pelvic binders: time to application and displacement during casualty evacuation

    by Thomas John Howe, H Claireaux, G Morgan, L McMenemy, S D Masouros, A Ramasamy

    Introduction: Pelvic injuries resulting from high-energy trauma have an approximately 10% mortality rate. Suspected pelvic injuries are treated with pelvic binders to stabilise fractured bones and promote tamponade until surgical treatment. The effectiveness of pelvic binders in reducing mortality risk depends on accurate positioning of the binder. This study quantifies the ability of proprietary and improvised pelvic binders to maintain their positioning during a simulated casualty evacuation. Methods: One improvised and three proprietary pelvic binders were tested in their ability to maintain their initial placement. Combat Medical Technicians applied binders to healthy subjects and then performed a simulated casualty evacuation. The time taken to apply each binder was measured. The evacuation consisted of: 20 m casualty drag, transfer onto a soft stretcher, 100 m evacuation on a soft stretcher, transfer onto a rigid stretcher and transfer into a field ambulance. Binder placement was measured using bony landmarks after the initial positioning and after each phase of the simulated casualty evacuation. Results: The field-expedient pelvic splint (FEPS), SAM Pelvic Sling II (SAM) and T-POD Pelvic Stabilisation Device (TPOD) all remained within 45 mm of vertical displacement from their initial placement, which is considered an acceptable range for optimal binder functionality. The Prometheus Pelvic Splint (PROM) fell within this range in 83% of trials. The SAM was the fastest binder to apply, followed by the TPOD, and then the FEPS and PROM which took similar times to apply. Conclusions: Binders were mostly able to maintain their positioning during the simulated casualty evacuations carried out in this study but differed in their application times. The improvised binder (FEPS) performed comparably to the proprietary binders tested, and its low cost and weight make it a good alternative to proprietary binders in the austere environment.


  • Open Access

    Mechanical assessment of proprietary and improvised pelvic binders for use in the prehospital environment

    by Thomas John Howe, H Claireaux, H Fox, G Morgan, L McMenemy, S D Masouros, A Ramasamy

    Introduction Pelvic fractures often result from high-energy trauma and are associated with a 10% mortality rate and significant morbidity. Pelvic binders are applied in suspected pelvic injury to stabilise fractured bone, decrease bleeding and potentiate tamponade. A binder must hold the pelvis with sufficient force for this effect to be achieved. This study aims to quantify the ability of proprietary and improvised pelvic binders to hold a target tensile force over time. Methods The ability of three proprietary and three improvised binders to hold a binding force for 2 hours was tested. A uniaxial materials testing machine was used to tension each binder to 150 N and then hold the displacement for 2 hours; the drop in tension over time was recorded for each binder. The ability to hold tension above 130 N after 2 hours was set as the metric of binder performance. Results The median tension at 2 hours was above 130 N for the SAM Pelvic Sling II and T-POD Pelvic Stabilisation Device and was below 130 N for the Prometheus Pelvic Splint, field-expedient pelvic splint (FES) and the Personal Clothing System-Multi-Terrain Pattern Combat Trousers binders. The tension in the improvised FES after 2 hours was approximately at the target 130 N; however, in 40% of the tests, it held above 130 N. Conclusions Binders varied in their ability to maintain sufficient tension to treat a pelvic fracture over the 2-hour testing period. The FES performed well under our testing regime; with relatively low cost and weight, it represents a good alternative to proprietary binders for the austere environment.


  • Open Access

    The Abbreviated Mental Test Score; Is There a Need for a Contemporaneous Update?

    by Kizzie A. Peters, Thomas J. Howe, Daniel Rossiter, Kirsty J. Hutchinson, Philip A. Rosell

    Introduction: Designed in 1972 the Abbreviated Mental Test Score (AMTS) is widely used to assess a cognition on hospital admission. The Nottingham Hip Fracture Score uses this in predicting morbidity/mortality in neck of femur fracture. The consequences of misappropriating cognitive impairment could have lasting implications. Questions about the monarchy or World War One and Two may be inappropriate for today’s diverse society. Materials and Methods: 100 patients were questioned during routine fracture clinic appointments. Patients were asked: In what year did WWII start? Who is the current monarch? Please state a memorable event in your lifetime that you would not expect another person of the same age to forget. Two-tailed Z-tests were performed between the observed proportions and those from the original AMTS validation study. Results: Only 47% (n = 47) were able to correctly answer the year in which WW2 started. A statistically significant difference when compared to the upper and lower limits from the original study (z = -4.191, p < .001.). Significance was not seen in the second question, with 97% (n-97) identifying the monarch correctly. 51% (n = 51) of participants suggested the terrorist attack on the World Trade Centre in New York as an alternative memorable event. Discussion: Some hospitals now use the 4 “A”s Test (4-AT) as a screening tool for delirium. Without amendments to the Nottingham Hip Fracture Score, AMTS use is likely to continue in orthogeriatric patients. Over time there will be a need for the AMTS to be reviewed so that it remains a true assessment of cognition. Its limitations regarding language and culture is widely acknowledged and several validated variants have been published in the literaure. Conclusions: We highlight a potential future issue with the AMTS and raise considerations for the development of an alternative question to better meet the needs of the orthogeriatric population.