Mark Adam Webb
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mark Adam Webb has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Ning Zhu
Canadian Light Source, University of Saskatchewan, 44 Innovation Boulevard, Saskatoon, SK S7N 2V3, Canada
3 shared publications - Aimy Bazylak
University of Toronto
2 shared publications - Chaeyoung Tina Ham
University of Toronto
2 shared publications - Daisy (Jihyung) Ko
Department of Anatomy, Physiology & Pharmacology, College of Medicine, University of Saskatchewan, 107 Wiggins Road, Saskatoon, SK S7N 5E5, Canada
2 shared publications - David M. L. Cooper
Department of Anatomy, Physiology & Pharmacology, College of Medicine, University of Saskatchewan, 107 Wiggins Road, Saskatoon, SK S7N 5E5, Canada
2 shared publications - George Belev
Canadian Light Source, University of Saskatchewan, 44 Innovation Boulevard, Saskatoon, SK S7N 2V3, Canada
2 shared publications
Latest Publications
- Open Access
- 18 May 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 683
Distinction and relationship between local and pore-scale saturation in fuel cell gas diffusion layers clarified via high-speed operando tomography
- 18 May 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 683
Open AccessDistinction and relationship between local and pore-scale saturation in fuel cell gas diffusion layers clarified via high-speed operando tomography
- Open Access
- 8 September 2025
- Published by Wiley in Advanced Science
- Vol. 12 (44) , e07606
The Role of Operating Temperature on Pore‐Scale Gas Transport in Polymer Electrolyte Membrane Electrolyzers
In this study, the effects of operating temperature on pore‐scale gas bubble transport in a carbon‐based anode porous transport layer (PTL) of a polymer electrolyte membrane (PEM) electrolyzer is revealed using operando X‐ray computed tomography (CT). Higher temperature operation (80 °C compared to 40 °C) led to a lower total gas bubble volume fraction in the PTL (0.25 to 0.17; 32% lower), which is attributed to improved water transport and gas removal. Higher temperatures led to fewer bubbles in the PTL (13% less at 80 °C compared to 40 °C) as well as a greater occurrence of smaller bubbles (35% increase in skewness of the bubble size distribution), and this behavior is attributed to faster rates of nucleation and bubble detachment from the electrode. The formation of gas slugs is also observed in the anode channels at 60 °C and 80 °C, which is attributed to the faster detachment and coalescence of bubbles from the PTL/flow field interface.
- 8 September 2025
- Published by Wiley in Advanced Science
- Vol. 12 (44) , e07606
Open AccessThe Role of Operating Temperature on Pore‐Scale Gas Transport in Polymer Electrolyte Membrane Electrolyzers
In this study, the effects of operating temperature on pore‐scale gas bubble transport in a carbon‐based anode porous transport layer (PTL) of a polymer electrolyte membrane (PEM) electrolyzer is revealed using operando X‐ray computed tomography (CT). Higher temperature operation (80 °C compared to 40 °C) led to a lower total gas bubble volume fraction in the PTL (0.25 to 0.17; 32% lower), which is attributed to improved water transport and gas removal. Higher temperatures led to fewer bubbles in the PTL (13% less at 80 °C compared to 40 °C) as well as a greater occurrence of smaller bubbles (35% increase in skewness of the bubble size distribution), and this behavior is attributed to faster rates of nucleation and bubble detachment from the electrode. The formation of gas slugs is also observed in the anode channels at 60 °C and 80 °C, which is attributed to the faster detachment and coalescence of bubbles from the PTL/flow field interface.
- Open Access
- 28 February 2025
- Published by MDPI AG in Journal of Developmental Biology
- Vol. 13 (1) , 7
Correction: Ko et al. Timing of Mouse Molar Formation Is Independent of Jaw Length Including Retromolar Space. J. Dev. Biol. 2021, 9, 8
There was an error in the original publication
- 28 February 2025
- Published by MDPI AG in Journal of Developmental Biology
- Vol. 13 (1) , 7
Open AccessCorrection: Ko et al. Timing of Mouse Molar Formation Is Independent of Jaw Length Including Retromolar Space. J. Dev. Biol. 2021, 9, 8
There was an error in the original publication
- Open Access
- 16 February 2025
- Published by Elsevier in Engineering Failure Analysis
- Vol. 172
Hydrogen uptake and embrittlement behavior in pipeline steels: Insights from slow strain rate testing and synchrotron micro-CT imaging
- 16 February 2025
- Published by Elsevier in Engineering Failure Analysis
- Vol. 172
Open AccessHydrogen uptake and embrittlement behavior in pipeline steels: Insights from slow strain rate testing and synchrotron micro-CT imaging
- Open Access
- 15 July 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (5) , 1346-1357
Hard X-ray imaging and tomography at the Biomedical Imaging and Therapy beamlines of Canadian Light Source
The Biomedical Imaging and Therapy facility of the Canadian Light Source comprises two beamlines, which together cover a wide X-ray energy range from 13 keV up to 140 keV. The beamlines were designed with a focus on synchrotron applications in preclinical imaging and veterinary science as well as microbeam radiation therapy. While these remain a major part of the activities of both beamlines, a number of recent upgrades have enhanced the versatility and performance of the beamlines, particularly for high-resolution microtomography experiments. As a result, the user community has been quickly expanding to include researchers in advanced materials, batteries, fuel cells, agriculture, and environmental studies. This article summarizes the beam properties, describes the endstations together with the detector pool, and presents several application cases of the various X-ray imaging techniques available to users.
- 15 July 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (5) , 1346-1357
Open AccessHard X-ray imaging and tomography at the Biomedical Imaging and Therapy beamlines of Canadian Light Source
The Biomedical Imaging and Therapy facility of the Canadian Light Source comprises two beamlines, which together cover a wide X-ray energy range from 13 keV up to 140 keV. The beamlines were designed with a focus on synchrotron applications in preclinical imaging and veterinary science as well as microbeam radiation therapy. While these remain a major part of the activities of both beamlines, a number of recent upgrades have enhanced the versatility and performance of the beamlines, particularly for high-resolution microtomography experiments. As a result, the user community has been quickly expanding to include researchers in advanced materials, batteries, fuel cells, agriculture, and environmental studies. This article summarizes the beam properties, describes the endstations together with the detector pool, and presents several application cases of the various X-ray imaging techniques available to users.
- Open Access
- 3 October 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (10) , e0291757
MRI overestimates articular cartilage thickness and volume compared to synchrotron radiation phase-contrast imaging
Accurate evaluation of morphological changes in articular cartilage are necessary for early detection of osteoarthritis (OA). 3T magnetic resonance imaging (MRI) has highly sensitive contrast resolution and is widely used clinically to detect OA. However, synchrotron radiation phase-contrast imaging computed tomography (SR-PCI) can also provide contrast to tissue interfaces that do not have sufficient absorption differences, with the added benefit of very high spatial resolution. Here, MRI was compared with SR-PCI for quantitative evaluation of human articular cartilage. Medial tibial condyles were harvested from non-OA donors and from OA patients receiving knee replacement surgery. Both imaging methods revealed that average cartilage thickness and cartilage volume were significantly reduced in the OA group, compared to the non-OA group. When comparing modalities, the superior resolution of SR-PCI enabled more precise mapping of the cartilage surface relative to MRI. As a result, MRI showed significantly higher average cartilage thickness and cartilage volume, compared to SR-PCI. These data highlight the potential for high-resolution imaging of articular cartilage using SR-PCI as a solution for early OA diagnosis. Recognizing current limitations of using a synchrotron for clinical imaging, we discuss its nascent utility for preclinical models, particularly longitudinal studies of live animal models of OA.
- 3 October 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (10) , e0291757
Open AccessMRI overestimates articular cartilage thickness and volume compared to synchrotron radiation phase-contrast imaging
Accurate evaluation of morphological changes in articular cartilage are necessary for early detection of osteoarthritis (OA). 3T magnetic resonance imaging (MRI) has highly sensitive contrast resolution and is widely used clinically to detect OA. However, synchrotron radiation phase-contrast imaging computed tomography (SR-PCI) can also provide contrast to tissue interfaces that do not have sufficient absorption differences, with the added benefit of very high spatial resolution. Here, MRI was compared with SR-PCI for quantitative evaluation of human articular cartilage. Medial tibial condyles were harvested from non-OA donors and from OA patients receiving knee replacement surgery. Both imaging methods revealed that average cartilage thickness and cartilage volume were significantly reduced in the OA group, compared to the non-OA group. When comparing modalities, the superior resolution of SR-PCI enabled more precise mapping of the cartilage surface relative to MRI. As a result, MRI showed significantly higher average cartilage thickness and cartilage volume, compared to SR-PCI. These data highlight the potential for high-resolution imaging of articular cartilage using SR-PCI as a solution for early OA diagnosis. Recognizing current limitations of using a synchrotron for clinical imaging, we discuss its nascent utility for preclinical models, particularly longitudinal studies of live animal models of OA.
- Open Access
- 12 March 2021
- Published by MDPI AG in Journal of Developmental Biology
- Vol. 9 (1) , 8
Timing of Mouse Molar Formation Is Independent of Jaw Length Including Retromolar Space
For humans and other mammals to eat effectively, teeth must develop properly inside the jaw. Deciphering craniodental integration is central to explaining the timely formation of permanent molars, including third molars which are often impacted in humans, and to clarifying how teeth and jaws fit, function and evolve together. A factor long-posited to influence molar onset time is the jaw space available for each molar organ to form within. Here, we tested whether each successive molar initiates only after a minimum threshold of space is created via jaw growth. We used synchrotron-based micro-CT scanning to assess developing molars in situ within jaws of C57BL/6J mice aged E10 to P32, encompassing molar onset to emergence. We compared total jaw, retromolar and molar lengths, and molar onset times, between upper and lower jaws. Initiation time and developmental duration were comparable between molar upper and lower counterparts despite shorter, slower-growing retromolar space in the upper jaw, and despite size differences between upper and lower molars. Timing of molar formation appears unmoved by jaw length including space. Conditions within the dental lamina likely influence molar onset much more than surrounding jaw tissues. We theorize that molar initiation is contingent on sufficient surface area for the physical reorganization of dental epithelium and its invagination of underlying mesenchyme.
- 12 March 2021
- Published by MDPI AG in Journal of Developmental Biology
- Vol. 9 (1) , 8
Open AccessTiming of Mouse Molar Formation Is Independent of Jaw Length Including Retromolar Space
For humans and other mammals to eat effectively, teeth must develop properly inside the jaw. Deciphering craniodental integration is central to explaining the timely formation of permanent molars, including third molars which are often impacted in humans, and to clarifying how teeth and jaws fit, function and evolve together. A factor long-posited to influence molar onset time is the jaw space available for each molar organ to form within. Here, we tested whether each successive molar initiates only after a minimum threshold of space is created via jaw growth. We used synchrotron-based micro-CT scanning to assess developing molars in situ within jaws of C57BL/6J mice aged E10 to P32, encompassing molar onset to emergence. We compared total jaw, retromolar and molar lengths, and molar onset times, between upper and lower jaws. Initiation time and developmental duration were comparable between molar upper and lower counterparts despite shorter, slower-growing retromolar space in the upper jaw, and despite size differences between upper and lower molars. Timing of molar formation appears unmoved by jaw length including space. Conditions within the dental lamina likely influence molar onset much more than surrounding jaw tissues. We theorize that molar initiation is contingent on sufficient surface area for the physical reorganization of dental epithelium and its invagination of underlying mesenchyme.