Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ning Zhu has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Cluster level entropy enhancement in neutral acetate electrolytes enables economical and durable zinc air batteries

    by Weinan Zhao, Yi Wang, Hossein Mashhadimoslem, Ning Zhu, Peyman Karimi, Zuankai Wang, Ali Elkamel, Zhongchao Tan, Aiping Yu, Zhongwei Chen

    Neutral zinc–air batteries provide a viable alternative to alkaline systems by avoiding salt creep and carbonate passivation. Among candidate electrolytes, acetate-based formulations are particularly attractive for their low cost, sustainability, and compatibility with ambient-air operation. However, their widespread adoption is limited by a trade-off between two concentration regimes. Dilute electrolytes trigger side reactions and lack ionic strength, while concentrated ones suffer from kinetic limitations due to contact ion pair clustering. Here, we propose a cluster-level entropy enhancement strategy that optimizes the mesoscopic configuration of the electrolyte by disrupting large clusters in concentrated acetate electrolytes. This entropy enhancement improves zinc ion diffusivity and kinetics, mitigates interfacial concentration gradients, and maintains local ionic strength for fast electrochemical reactions, as evidenced by various synchrotron X-ray techniques and theoretical simulations. Consequently, the zinc–air batteries in neutral electrolyte deliver over 1800 hours at 0.1 mA cm-2 (1 mAh cm-2, 61.4% round-trip efficiency) and 500 hours at 1 mA cm-2 (12 mAh cm-2, 51.2% round-trip efficiency) in ambient air. This study extends the application of sustainable acetate electrolytes in neutral zinc–air batteries and illustrates a mesoscopic tuning approach applicable to aqueous energy systems with metal electrodes and concentrated solvents.


  • Open Access

    Development of a deep learning method for phase retrieval image enhancement in phase contrast microcomputed tomography

    by Xiao Fan Ding, Xiaoman Duan, Naitao Li, Zahra Khoz, Fang‐Xiang Wu, Xiongbiao Chen, Ning Zhu

    Propagation‐based imaging (one method of X‐ray phase contrast imaging) with microcomputed tomography (PBI‐µCT) offers the potential to visualise low‐density materials, such as soft tissues and hydrogel constructs, which are difficult to be identified by conventional absorption‐based contrast µCT. Conventional µCT reconstruction produces edge‐enhanced contrast (EEC) images which preserve sharp boundaries but are susceptible to noise and do not provide consistent grey value representation for the same material. Meanwhile, phase retrieval (PR) algorithms can convert edge enhanced contrast to area contrast to improve signal‐to‐noise ratio (SNR), and contrast‐to‐noise ratio (CNR) but usually results to over‐smoothing, thus creating inaccuracies in quantitative analysis. To alleviate these problems, this study developed a deep learning‐based method called edge view enhanced phase retrieval (EVEPR), by strategically integrating the complementary spatial features of denoised EEC and PR images, and further applied this method to segment the hydrogel constructs in vivo and ex vivo. EVEPR used paired denoised EEC and PR images to train a deep convolutional neural network (CNN) on a dataset‐to‐dataset basis. The CNN had been trained on important high‐frequency details, for example, edges and boundaries from the EEC image and area contrast from PR images. The CNN predicted result showed enhanced area contrast beyond conventional PR algorithms while improving SNR and CNR. The enhanced CNR especially allowed for the image to be segmented with greater efficiency. EVEPR was applied to in vitro and ex vivo PBI‐µCT images of low‐density hydrogel constructs. The enhanced visibility and consistency of hydrogel constructs was essential for segmenting such material which usually exhibit extremely poor contrast. The EVEPR images allowed for more accurate segmentation with reduced manual adjustments. The efficiency in segmentation allowed for the generation of a sizeable database of segmented hydrogel scaffolds which were used in conventional data‐driven segmentation applications. EVEPR was demonstrated to be a robust post‐image processing method capable of significantly enhancing image quality by training a CNN on paired denoised EEC and PR images. This method not only addressed the common issues of over‐smoothing and noise susceptibility in conventional PBI‐µCT image processing but also allowed for efficient and accurate in vitro and ex vivo image processing applications of low‐density materials.


  • Open Access

    Correction: Ko et al. Timing of Mouse Molar Formation Is Independent of Jaw Length Including Retromolar Space. J. Dev. Biol. 2021, 9, 8

    by Daisy (Jihyung) Ko, Tess Kelly, Lacey Thompson, Jasmene K. Uppal, Nasim Rostampour, Mark Adam Webb, Ning Zhu, George Belev, Prosanta Mondal, David M. L. Cooper, et al.

    There was an error in the original publication

  • Open Access

    Development of a low-dose strategy for propagation-based imaging helical computed tomography (PBI-HCT): high image quality and reduced radiation dose

    by Xiaoman Duan, Xiao Fan Ding, Samira Khoz, Xiongbiao Chen, Ning Zhu

    Background. Propagation-based imaging computed tomography (PBI-CT) has been recently emerging for visualizing low-density materials due to its excellent image contrast and high resolution. Based on this, PBI-CT with a helical acquisition mode (PBI-HCT) offers superior imaging quality (e.g., fewer ring artifacts) and dose uniformity, making it ideal for biomedical imaging applications. However, the excessive radiation dose associated with high-resolution PBI-HCT may potentially harm objects or hosts being imaged, especially in live animal imaging, raising a great need to reduce radiation dose.Methods. In this study, we strategically integrated Sparse2Noise (a deep learning approach) with PBI-HCT imaging to reduce radiation dose without compromising image quality. Sparse2Noise uses paired low-dose noisy images with different photon fluxes and projection numbers for high-quality reconstruction via a convolutional neural network (CNN). Then, we examined the imaging quality and radiation dose of PBI-HCT imaging using Sparse2Noise, as compared to when Sparse2Noise was used in low-dose PBI-CT imaging (circular scanning mode). Furthermore, we conducted a comparison study on the use of Sparse2Noise versus two other state-of-the-art low-dose imaging algorithms (i.e., Noise2Noise and Noise2Inverse) for imaging low-density materials using PBI-HCT at equivalent dose levels. Results. Sparse2Noise allowed for a 90% dose reduction in PBI-HCT imaging while maintaining high image quality. As compared to PBI-CT imaging, the use of Sparse2Noise in PBI-HCT imaging shows more effective by reducing additional radiation dose (30%–36%). Furthermore, helical scanning mode also enhances the performance of existing low-dose algorithms (Noise2Noise and Noise2Inverse); nevertheless, Sparse2Noise shows significantly higher signal-to-noise ratio (SNR) value compared to Noise2Noise and Noise2Inverse at the same radiation dose level. Conclusions and significance. Our proposed low-dose imaging strategy Sparse2Noise can be effectively applied to PBI-HCT imaging technique and requires lower dose for acceptable quality imaging. This would represent a significant advance imaging for low-density materials imaging and for future live animals imaging applications.


  • Open Access

    Development of A deep Learning-based algorithm for High-Pitch helical computed tomography imaging

    by Xiaoman Duan, Xiao Fan Ding, Samira Khoz, Xiongbiao Chen, Ning Zhu


  • Open Access

    Hard X-ray imaging and tomography at the Biomedical Imaging and Therapy beamlines of Canadian Light Source

    by Sergey Gasilov, M. Adam Webb, Arash Panahifar, Ning Zhu, Omar Marinos, Toby Bond, David M. L. Cooper, Dean Chapman

    The Biomedical Imaging and Therapy facility of the Canadian Light Source comprises two beamlines, which together cover a wide X-ray energy range from 13 keV up to 140 keV. The beamlines were designed with a focus on synchrotron applications in preclinical imaging and veterinary science as well as microbeam radiation therapy. While these remain a major part of the activities of both beamlines, a number of recent upgrades have enhanced the versatility and performance of the beamlines, particularly for high-resolution microtomography experiments. As a result, the user community has been quickly expanding to include researchers in advanced materials, batteries, fuel cells, agriculture, and environmental studies. This article summarizes the beam properties, describes the endstations together with the detector pool, and presents several application cases of the various X-ray imaging techniques available to users.


  • Sparse2Noise: Low-dose synchrotron X-ray tomography without high-quality reference data

    by Xiaoman Duan, Xiao Fan Ding, Naitao Li, Fang-Xiang Wu, Xiongbiao Chen, Ning Zhu


  • Construction of desolvated ionic COF artificial SEI layer stabilized Zn metal anode by in-situ electrophoretic deposition

    by Leixin Yang, Qianyi Ma, Yuelong Yin, Dan Luo, Yujie Shen, Haozhen Dou, Ning Zhu, Renfei Feng, Yaping Kong, Aiping Yu, et al.


  • Open Access

    In situ wet pharmaceutical granulation captured using synchrotron radiation based dynamic micro-CT

    by Xiao Fan Ding, Sima Zeinali Danalou, Lifeng Zhang, Ning Zhu

    Synchrotron radiation based dynamic micro-computed tomography (micro-CT) is a powerful technique available at synchrotron light sources for investigating evolving microstructures. Wet granulation is the most widely used method of producing pharmaceutical granules, precursors to products like capsules and tablets. Granule microstructures are known to influence product performance, so this is an area for potential application of dynamic CT. Here, lactose monohydrate (LMH) was used as a representative powder to demonstrate dynamic CT capabilities. Wet granulation of LMH has been observed to occur on the order of several seconds, which is too fast for lab-based CT scanners to capture the changing internal structures. The superior X-ray photon flux from synchrotron light sources makes sub-second data acquisition possible and well suited for analysis of the wet-granulation process. Moreover, synchrotron radiation based imaging is non-destructive, does not require altering the sample in any way, and can enhance image contrast with phase-retrieval algorithms. Dynamic CT can bring insights to wet granulation, an area of research previously only studied via 2D and/or ex situ techniques. Through efficient data-processing strategies, dynamic CT can provide quantitative analysis of how the internal microstructure of an LMH granule evolves during the earliest moments of wet granulation. Here, the results revealed granule consolidation, the evolving porosity, and the influence of aggregates on granule porosity.