Heri Nugraha
Research Subjects
Heri Nugraha has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
A Achmadi
National Standardization Agency of Indonesia - BSN Kawasan Puspiptek, Serpong, Banten, Indonesia
1 shared publicationA Imaduddin
Research Center for Metallurgy and Material - LIPI Gedung 470, Kawasan Puspiptek, Serpong, Banten, Indonesia
1 shared publicationA S Wismogroho
Research Center for Physics - LIPI Gedung 442, Kawasan Puspiptek, Serpong, Banten, Indonesia
1 shared publicationAditya Achmadi
National Standardization Agency of Indonesia Serpong 15314, Tangerang Selatan, Banten, Indonesia
1 shared publicationAgung Imaduddin
Research Center for Metallurgy and Material, Indonesian Institute of Sciences Serpong 15314, Tangerang Selatan, Banten, Indonesia
1 shared publicationAgus Sukarto Wismogroho
Research Center for Physics, Indonesian Institute of Sciences Serpong 15314, Tangerang Selatan, Banten, Indonesia
1 shared publication
Latest Publications
- Open Access
- 1 June 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2243 (1) , 012039
Real-Time Monitoring System for Thermocouple Inhomogeneity Equipment
Thermocouple inhomogeneity equipment was developed to measure the Seebeck coefficient characteristic in each wire position based on the effect of temperature exposure along the thermocouple wire. Temperature and distance sensors are used to measure the temperature output of the heating system and the movement of the thermocouple position. We developed a real-time measurement system to monitor the measurement of the thermocouple sensor based on a microcontroller. This monitoring system is needed to monitor changes in the ice bath during measurement, if the ice bath was unstable or being melting, it can affect the output voltage of the thermocouple. The program was compiled and uploaded to ESP 32 then monitoring data with an open-source internet of things called Thingspeak was used as a platform to retrieve and display the collected data. Real-time monitoring of distance from ultrasonic and temperature of heat source (heat gun) can be accessed through web applications and smartphones. The data were analyzed based on conditions for Seebeck value of inhomogeneity and validated with standard calibration using the liquid bath. This study has been considered successfully implemented that performs on IoT platforms and was adaptively ready to monitor thermocouple inhomogeneity equipment.
- 1 June 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2243 (1) , 012039
Open AccessReal-Time Monitoring System for Thermocouple Inhomogeneity Equipment
Thermocouple inhomogeneity equipment was developed to measure the Seebeck coefficient characteristic in each wire position based on the effect of temperature exposure along the thermocouple wire. Temperature and distance sensors are used to measure the temperature output of the heating system and the movement of the thermocouple position. We developed a real-time measurement system to monitor the measurement of the thermocouple sensor based on a microcontroller. This monitoring system is needed to monitor changes in the ice bath during measurement, if the ice bath was unstable or being melting, it can affect the output voltage of the thermocouple. The program was compiled and uploaded to ESP 32 then monitoring data with an open-source internet of things called Thingspeak was used as a platform to retrieve and display the collected data. Real-time monitoring of distance from ultrasonic and temperature of heat source (heat gun) can be accessed through web applications and smartphones. The data were analyzed based on conditions for Seebeck value of inhomogeneity and validated with standard calibration using the liquid bath. This study has been considered successfully implemented that performs on IoT platforms and was adaptively ready to monitor thermocouple inhomogeneity equipment.
- Open Access
- 1 February 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1825 (1) , 012031
Development of Inhomogeneity Measurement System for Type T Thermocouple with Local Heating Method
The voltage of thermocouple during process contribution is determined by the absolute thermal electromotive force coefficient in each wire and the temperature difference across the section. This paper described the development of a system as a local heating method for measurements of inhomogeneities in type T thermocouples with various temperature scanning using hot air. The system could control automatically measurement voltage, temperature, distance, and speed of the stepper motor for moving the hot air scanning along with the thermocouple and control with temperature monitoring. Both the measuring and reference junctions were using an ice bath kept at 0 °C. In this paper calculation of interpretation of the measurement results of inhomogeneity using movable heating zone system of type T thermocouples and the system could detected inhomogeneity of thermocouple and there have different characteristics of voltage and seebeck effect.
- 1 February 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1825 (1) , 012031
Open AccessDevelopment of Inhomogeneity Measurement System for Type T Thermocouple with Local Heating Method
The voltage of thermocouple during process contribution is determined by the absolute thermal electromotive force coefficient in each wire and the temperature difference across the section. This paper described the development of a system as a local heating method for measurements of inhomogeneities in type T thermocouples with various temperature scanning using hot air. The system could control automatically measurement voltage, temperature, distance, and speed of the stepper motor for moving the hot air scanning along with the thermocouple and control with temperature monitoring. Both the measuring and reference junctions were using an ice bath kept at 0 °C. In this paper calculation of interpretation of the measurement results of inhomogeneity using movable heating zone system of type T thermocouples and the system could detected inhomogeneity of thermocouple and there have different characteristics of voltage and seebeck effect.