Charles Ajith Wijayawardhana
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Charles Ajith Wijayawardhana has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
H. Brian Halsall
University of Cincinnati, Cincinnati, Ohio
5 shared publicationsWilliam R. Heineman
University of Cincinnati, Cincinnati, Ohio
5 shared publications- Christian Militzer
SGL Carbon GmbH 2 , Drachenburgstraße 1, DE-53170 Bonn, Germany
2 shared publications Gunther Wittstock
2 shared publicationsH.Brian Halsall
Department of Chemistry, University of Cincinnati, P.O. Box 210172, Cincinnati, OH 45221-0172, USA
2 shared publications- Henrik Pedersen
Department of Physics, Chemistry and Biology, Linköping University , SE-581 83 Linköping
2 shared publications
Latest Publications
- Open Access
- 27 April 2023
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 41 (3)
Superconformal silicon carbide coatings via precursor pulsed chemical vapor deposition
In this work, silicon carbide (SiC) coatings were successfully grown by pulsed chemical vapor deposition (CVD). The precursors silicon tetrachloride (SiCl4) and ethylene (C2H4) were not supplied in a continuous flow but were pulsed alternately into the growth chamber with H2 as a carrier and a purge gas. A typical pulsed CVD cycle was SiCl4 pulse—H2 purge—C2H4 pulse—H2 purge. This led to growth of superconformal SiC coatings, which could not be obtained under similar process conditions using a constant flow CVD process. We propose a two-step framework for SiC growth via pulsed CVD. During the SiCl4 pulse, a layer of Si is deposited. In the following C2H4 pulse, this Si layer is carburized, and SiC is formed. The high chlorine surface coverage after the SiCl4 pulse is believed to enable superconformal growth via a growth inhibition effect.
- 27 April 2023
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 41 (3)
Open AccessSuperconformal silicon carbide coatings via precursor pulsed chemical vapor deposition
In this work, silicon carbide (SiC) coatings were successfully grown by pulsed chemical vapor deposition (CVD). The precursors silicon tetrachloride (SiCl4) and ethylene (C2H4) were not supplied in a continuous flow but were pulsed alternately into the growth chamber with H2 as a carrier and a purge gas. A typical pulsed CVD cycle was SiCl4 pulse—H2 purge—C2H4 pulse—H2 purge. This led to growth of superconformal SiC coatings, which could not be obtained under similar process conditions using a constant flow CVD process. We propose a two-step framework for SiC growth via pulsed CVD. During the SiCl4 pulse, a layer of Si is deposited. In the following C2H4 pulse, this Si layer is carburized, and SiC is formed. The high chlorine surface coverage after the SiCl4 pulse is believed to enable superconformal growth via a growth inhibition effect.
- Open Access
- 4 June 2022
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 126 (23) , 9918-9925
Controlled CVD Growth of Highly ⟨111⟩-Oriented 3C-SiC
- 4 June 2022
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 126 (23) , 9918-9925
Open AccessControlled CVD Growth of Highly ⟨111⟩-Oriented 3C-SiC
- 1 January 2004
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 561, 83-91
Monitoring β-galactosidase activity by means of scanning electrochemical microscopy
- 1 January 2004
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 561, 83-91
Monitoring β-galactosidase activity by means of scanning electrochemical microscopy
- 27 August 2002
- Published by Wiley
Electrochemical Immunoassay
The sections in this article areIntroduction: Enzyme Electrochemical Immunoassays: Electrochemical Detection: TheE‐S‐PSystem: Heterogeneous Enzyme Immunoassay: Ultrasensitive Heterogeneous Enzyme Assays in Small Volumes: Homogeneous Enzyme Immunoassay: Nonenzyme Electrochemical Immunoassays: Nonenzyme Homogeneous Immunoassays: Heterogeneous Nonenzymatic Immunoassays: Electrochemical Immunosensors: Applications: Conclusion:
- 27 August 2002
- Published by Wiley
Electrochemical Immunoassay
The sections in this article areIntroduction: Enzyme Electrochemical Immunoassays: Electrochemical Detection: TheE‐S‐PSystem: Heterogeneous Enzyme Immunoassay: Ultrasensitive Heterogeneous Enzyme Assays in Small Volumes: Homogeneous Enzyme Immunoassay: Nonenzyme Electrochemical Immunoassays: Nonenzyme Homogeneous Immunoassays: Heterogeneous Nonenzymatic Immunoassays: Electrochemical Immunosensors: Applications: Conclusion:
- 27 September 2001
- Published by Elsevier in Analytica Chimica Acta
- Vol. 444 (1) , 13-26
“Bugbead”: an artificial microorganism model used as a harmless simulant for pathogenic microorganisms
- 27 September 2001
- Published by Elsevier in Analytica Chimica Acta
- Vol. 444 (1) , 13-26
“Bugbead”: an artificial microorganism model used as a harmless simulant for pathogenic microorganisms
- 1 September 2001
- Published by Springer Nature in Biomedical Microdevices
- Vol. 3 (3) , 191-200
Development and Characterization of Microfluidic Devices and Systems for Magnetic Bead-Based Biochemical Detection
- 1 September 2001
- Published by Springer Nature in Biomedical Microdevices
- Vol. 3 (3) , 191-200
Development and Characterization of Microfluidic Devices and Systems for Magnetic Bead-Based Biochemical Detection
- 30 January 2001
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 126 (3) , 337-341
Small volume bead assay for ovalbumin with electrochemical detection
A bead based sandwich enzyme immunoassay coupled to electrochemical detection for ovalbumin has been developed. The enzyme label alkaline phosphatase was used to convert the substrate 4-aminophenyl phosphate to electroactive product 4-aminophenol. The detection was done in a microdrop by continuously monitoring the enzyme turnover with a rotating disk electrode. This reduces dilution of the enzyme product, a key to achieving low detection limits. The assay developed has a detection limit of 0.1 ng ml−1. Assay sensitivity in complex matrices such as food and serum was compared.
- 30 January 2001
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 126 (3) , 337-341
Small volume bead assay for ovalbumin with electrochemical detection
A bead based sandwich enzyme immunoassay coupled to electrochemical detection for ovalbumin has been developed. The enzyme label alkaline phosphatase was used to convert the substrate 4-aminophenyl phosphate to electroactive product 4-aminophenol. The detection was done in a microdrop by continuously monitoring the enzyme turnover with a rotating disk electrode. This reduces dilution of the enzyme product, a key to achieving low detection limits. The assay developed has a detection limit of 0.1 ng ml−1. Assay sensitivity in complex matrices such as food and serum was compared.
- 1 May 2000
- Published by Wiley in Electroanalysis
- Vol. 12 (9) , 640-644
Electrochemical Immunoassay with Microscopic Immunomagnetic Bead Domains and Scanning Electrochemical Microscopy
- 1 May 2000
- Published by Wiley in Electroanalysis
- Vol. 12 (9) , 640-644
Electrochemical Immunoassay with Microscopic Immunomagnetic Bead Domains and Scanning Electrochemical Microscopy
- 11 December 1999
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 72 (2) , 333-338
Spatially Addressed Deposition and Imaging of Biochemically Active Bead Microstructures by Scanning Electrochemical Microscopy
A new procedure is described to deposit paramagnetic beads on surfaces to form microscopic agglomerates. By using surface-modified beads, microscopic structures with defined biochemical activity are formed. The shape and size of agglomerates were characterized by scanning electron microscopy (SEM), and the biochemical activity was mapped with scanning electrochemical microscopy (SECM). This approach is demonstrated using beads modified with anti-mouse antibodies (Ab). After allowing them to react with a conjugate of mouse IgG and alkaline phosphatase (ALP), the beads were deposited as agglomerates of well-defined size and shape. The biochemical activity was recorded in the generation−collection SECM mode by oxidizing 4-aminophenol formed in the ALP-catalyzed hydrolysis of 4-aminophenyl phosphate at the surface of the beads. The signal height correlated with both the amount of beads present in one agglomerate and the proportion of Ab binding sites saturated with the ALP−mouse IgG conjugate. The feedback mode of the SECM was used to image streptavidin-coated beads after reaction with biotinylated glucose oxidase.
- 11 December 1999
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 72 (2) , 333-338
Spatially Addressed Deposition and Imaging of Biochemically Active Bead Microstructures by Scanning Electrochemical Microscopy
A new procedure is described to deposit paramagnetic beads on surfaces to form microscopic agglomerates. By using surface-modified beads, microscopic structures with defined biochemical activity are formed. The shape and size of agglomerates were characterized by scanning electron microscopy (SEM), and the biochemical activity was mapped with scanning electrochemical microscopy (SECM). This approach is demonstrated using beads modified with anti-mouse antibodies (Ab). After allowing them to react with a conjugate of mouse IgG and alkaline phosphatase (ALP), the beads were deposited as agglomerates of well-defined size and shape. The biochemical activity was recorded in the generation−collection SECM mode by oxidizing 4-aminophenol formed in the ALP-catalyzed hydrolysis of 4-aminophenyl phosphate at the surface of the beads. The signal height correlated with both the amount of beads present in one agglomerate and the proportion of Ab binding sites saturated with the ALP−mouse IgG conjugate. The feedback mode of the SECM was used to image streptavidin-coated beads after reaction with biotinylated glucose oxidase.
- 25 October 1999
- Published by Elsevier in Analytica Chimica Acta
- Vol. 399 (1-2) , 3-11
Micro volume rotating disk electrode (RDE) amperometric detection for a bead-based immunoassay
- 25 October 1999
- Published by Elsevier in Analytica Chimica Acta
- Vol. 399 (1-2) , 3-11
Micro volume rotating disk electrode (RDE) amperometric detection for a bead-based immunoassay