Robert J. Marchbanks
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Robert J. Marchbanks has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Anthony A. Birch
University Hospital Southampton NHS Foundation Trust
3 shared publications - Cherith M. Campbell-Bell
Rinri Therapeutics Ltd., Sheffield, UK
2 shared publications - Ann-Marie Hughes
School of Health Sciences, University of Southampton, Southampton SO17 1BJ, UK
1 shared publication - Christopher Myles Kipps
Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton, UK
1 shared publication - Christopher T. Freeman
University of Southampton
1 shared publication - Diederik Bulters
Wessex Neurological Centre, University Hospital Southampton NHS Foundation Trust, Southampton, UK
1 shared publication
Latest Publications
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 33 (5) , 1509-1520
Model Predictive Valve Control to Assist Lung Pressure Profile Tracking
In U.K. 60 000 people have a brain tumor and typically are unaware of its presence until symptoms occur. Currently, there is no mass screening available due to limitations in diagnostic techniques. Measurement of intracranial pressure (ICP) [via tympanic membrane displacement (TMD)] is a potential low-cost, accessible solution; however, pressure fluctuations degrade its accuracy. This article solves the problem by assisting participants to precisely track airway pressure profiles. This stabilizes intrathoracic pressure, significantly reducing the fluctuations and enabling accurate diagnosis of ICP. This article develops and evaluates the first model of lung pressure tracking to embed volitional control action. A clinically feasible identification approach is then derived, together with a novel model predictive control (MPC) framework, embedding a valve control subsystem. Results with ten participants confirm that tracking is improved by an average of 22%.
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 33 (5) , 1509-1520
Model Predictive Valve Control to Assist Lung Pressure Profile Tracking
In U.K. 60 000 people have a brain tumor and typically are unaware of its presence until symptoms occur. Currently, there is no mass screening available due to limitations in diagnostic techniques. Measurement of intracranial pressure (ICP) [via tympanic membrane displacement (TMD)] is a potential low-cost, accessible solution; however, pressure fluctuations degrade its accuracy. This article solves the problem by assisting participants to precisely track airway pressure profiles. This stabilizes intrathoracic pressure, significantly reducing the fluctuations and enabling accurate diagnosis of ICP. This article develops and evaluates the first model of lung pressure tracking to embed volitional control action. A clinically feasible identification approach is then derived, together with a novel model predictive control (MPC) framework, embedding a valve control subsystem. Results with ten participants confirm that tracking is improved by an average of 22%.
- Open Access
- 28 February 2022
- Published by Elsevier in Cerebral Circulation - Cognition and Behavior
- Vol. 3, 100132
Pulsatile tympanic membrane displacement is associated with cognitive score in healthy subjects
- 28 February 2022
- Published by Elsevier in Cerebral Circulation - Cognition and Behavior
- Vol. 3, 100132
Open AccessPulsatile tympanic membrane displacement is associated with cognitive score in healthy subjects
- Open Access
- 1 February 2021
- Published by IOP Publishing in Physiological Measurement
- Vol. 42 (2) , 025001
A vascular subtraction method for improving the variability of evoked tympanic membrane displacement measurements
Objective . Evoked tympanic membrane displacement (TMD) measurements show a correlation with intracranial pressure (ICP). Attempts to use these measurements for non-invasive monitoring of ICP in patients have been limited by high measurement variability. Pulsing of the tympanic membrane at the cardiac frequency has been shown to be a significant source of the variability. In this study we describe a post processing method to remove the cardiac pulse waveform and assess the impact of this on the measurement and its repeatability. Approach . Three-hundred and sixteen healthy volunteers were recruited for evoked TMD measurements. The measurements were quantified by V m , defined as the mean displacement between the point of maximum inward displacement and the end of the stimulus. A sample of spontaneously pulsing TMDs was measured immediately before the evoked measurements. Simultaneous recording of the ECG allowed a heartbeat template to be extracted from the spontaneous data and subtracted from the evoked data. Intra-subject repeatability of V m was assessed from 20 repeats of the evoked measurement. Results with and without subtraction of the heartbeat template were compared. The difference was tested for significance using the Wilcoxon sign rank test. Main results . In left and right ears, both sitting and supine, application of the pulse correction significantly reduced the intra-subject variability of V m ( p value range 4.0 × 10 −27 to 2.0 × 10 −31 ). The average improvement was from 98 ± 6 nl to 56 ± 4 nl. Significance . The pulse subtraction technique substantially improves the repeatability of evoked TMD measurements. This justifies further investigations to assess the use of TMD measurements in clinical applications where non-invasive tracking of changes in ICP would be useful.
- 1 February 2021
- Published by IOP Publishing in Physiological Measurement
- Vol. 42 (2) , 025001
Open AccessA vascular subtraction method for improving the variability of evoked tympanic membrane displacement measurements
Objective . Evoked tympanic membrane displacement (TMD) measurements show a correlation with intracranial pressure (ICP). Attempts to use these measurements for non-invasive monitoring of ICP in patients have been limited by high measurement variability. Pulsing of the tympanic membrane at the cardiac frequency has been shown to be a significant source of the variability. In this study we describe a post processing method to remove the cardiac pulse waveform and assess the impact of this on the measurement and its repeatability. Approach . Three-hundred and sixteen healthy volunteers were recruited for evoked TMD measurements. The measurements were quantified by V m , defined as the mean displacement between the point of maximum inward displacement and the end of the stimulus. A sample of spontaneously pulsing TMDs was measured immediately before the evoked measurements. Simultaneous recording of the ECG allowed a heartbeat template to be extracted from the spontaneous data and subtracted from the evoked data. Intra-subject repeatability of V m was assessed from 20 repeats of the evoked measurement. Results with and without subtraction of the heartbeat template were compared. The difference was tested for significance using the Wilcoxon sign rank test. Main results . In left and right ears, both sitting and supine, application of the pulse correction significantly reduced the intra-subject variability of V m ( p value range 4.0 × 10 −27 to 2.0 × 10 −31 ). The average improvement was from 98 ± 6 nl to 56 ± 4 nl. Significance . The pulse subtraction technique substantially improves the repeatability of evoked TMD measurements. This justifies further investigations to assess the use of TMD measurements in clinical applications where non-invasive tracking of changes in ICP would be useful.