Çağatay Yıldız
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Çağatay Yıldız has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Müslüm Arıcı
Mechanical Engineering Department, Engineering Faculty, Kocaeli University, Kocaeli 41001, Turkey
10 shared publications Dong Li
7 shared publications- Amin Shahsavar
Kermanshah University of Technology
4 shared publications - Mustafa Seçilmiş4 shared publications
- Ekrem Tunçbilek
Kocaeli Üniversitesi
3 shared publications Müslüm Arıcı
3 shared publications
Latest Publications
- 1 September 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (9)
Coupled effects of dome-shaped geometry and inclination on buoyancy-driven flow and melting dynamics in latent heat storage units
Combined effects of enclosure geometry and inclination angle on the melting behavior of coconut oil as a bio-based phase change material (PCM) were numerically assessed. A conventional square enclosure (SQ) and three different dome-shaped enclosures (D1, D2, and D3) with varying dome heights but identical PCM volumes were evaluated at four inclination angles of θ = 0°, 30°, 60°, and 90°. Simulations were conducted using the enthalpy-porosity technique, and the numerical procedure was validated against experimental data. The contour results indicate that the D3 configuration, which has the highest dome, redistributes the circulation in the upper region and facilitates the upward motion of thermal plumes. Quantitatively, tilting the reference SQ from θ = 0° to θ = 90° reduced the melting time from 111 to 49 min, achieving a 55.8% reduction. A corresponding reduction of 52.3% was observed for D3 configuration. Furthermore, at the vertical orientation (θ = 0°), the constant-volume D3 modification reduced the total melting time to 96.5 min, which was 13% lower than that of SQ. Additionally, in the side-heating orientation, SQ required 83.5 min to reach the target energy storage of 280 kJ, whereas D3 reached the same value in 62.5 min, corresponding to a 25.1% reduction in charging time. These outcomes show that the relative benefit of the constant-volume D3 configuration is greater in the side-heating orientation, where natural convection is weaker. Consequently, within the investigated two-dimensional, constant-volume configuration, the combined modification of the top boundary geometry and enclosure width is promising for improving melting and charging performance, particularly in the side-heating orientation.
- 1 September 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (9)
Coupled effects of dome-shaped geometry and inclination on buoyancy-driven flow and melting dynamics in latent heat storage units
Combined effects of enclosure geometry and inclination angle on the melting behavior of coconut oil as a bio-based phase change material (PCM) were numerically assessed. A conventional square enclosure (SQ) and three different dome-shaped enclosures (D1, D2, and D3) with varying dome heights but identical PCM volumes were evaluated at four inclination angles of θ = 0°, 30°, 60°, and 90°. Simulations were conducted using the enthalpy-porosity technique, and the numerical procedure was validated against experimental data. The contour results indicate that the D3 configuration, which has the highest dome, redistributes the circulation in the upper region and facilitates the upward motion of thermal plumes. Quantitatively, tilting the reference SQ from θ = 0° to θ = 90° reduced the melting time from 111 to 49 min, achieving a 55.8% reduction. A corresponding reduction of 52.3% was observed for D3 configuration. Furthermore, at the vertical orientation (θ = 0°), the constant-volume D3 modification reduced the total melting time to 96.5 min, which was 13% lower than that of SQ. Additionally, in the side-heating orientation, SQ required 83.5 min to reach the target energy storage of 280 kJ, whereas D3 reached the same value in 62.5 min, corresponding to a 25.1% reduction in charging time. These outcomes show that the relative benefit of the constant-volume D3 configuration is greater in the side-heating orientation, where natural convection is weaker. Consequently, within the investigated two-dimensional, constant-volume configuration, the combined modification of the top boundary geometry and enclosure width is promising for improving melting and charging performance, particularly in the side-heating orientation.
- 17 March 2026
- Published by Türkiye Enerji Stratejileri ve Politikalari Araştirma Merkezi (TESPAM) in International Journal of Energy Studies
- Vol. 11 (1) , 437-460
Effect of concave and convex side-wall curvature on natural convective heat transfer in trapezoidal enclosures
Focusing on the enhancement effects of fluid flow alteration on natural convective heat transfer in enclosures, this study presents a numerical investigation about natural convection behavior inside the concave and convex shaped trapezoidal-based enclosures. The side walls of a two-dimensional standard isosceles trapezoidal enclosure (TE) were modified to constitute concave and convex enclosures based on the reference geometry. Regarding the wall curvature, three different concave (C1, C2, and C3) and three different convex (V1, V2, and V3) enclosures were examined in terms of natural convective heat transfer, considering three different Rayleigh numbers (Ra=104, 105, and 106). The governing equations of the problem was solved by finite volume based commercial software, and the heat transfer performance was discussed over dimensionless streamline and temperature contours, as well as quantified by average Nusselt numbers (Nu). The numerical outcomes revealed that the curvature of side walls have significant effects on buoyancy-driven fluid flow and heat transfer. The fluid flow was squeezed and restricted in concave enclosures, particularly at high Ra, while double longitudinal circulations were generally formed in convex enclosures. Hence, utilization of concave enclosures led to a significant decrease in Nu, approaching 45%, while the convex-shaped enclosures resulted in a remarkable improvement in Nu, which can reach up to 18.6% depending on the Ra, compared to the reference enclosure. Regarding the outcomes of the work, convex-structured enclosures were found to be superior for enhancing heat transfer and were recommended for engineering applications such as cooling of electronics, solar thermal energy and relevant heat exchangers.
- 17 March 2026
- Published by Türkiye Enerji Stratejileri ve Politikalari Araştirma Merkezi (TESPAM) in International Journal of Energy Studies
- Vol. 11 (1) , 437-460
Effect of concave and convex side-wall curvature on natural convective heat transfer in trapezoidal enclosures
Focusing on the enhancement effects of fluid flow alteration on natural convective heat transfer in enclosures, this study presents a numerical investigation about natural convection behavior inside the concave and convex shaped trapezoidal-based enclosures. The side walls of a two-dimensional standard isosceles trapezoidal enclosure (TE) were modified to constitute concave and convex enclosures based on the reference geometry. Regarding the wall curvature, three different concave (C1, C2, and C3) and three different convex (V1, V2, and V3) enclosures were examined in terms of natural convective heat transfer, considering three different Rayleigh numbers (Ra=104, 105, and 106). The governing equations of the problem was solved by finite volume based commercial software, and the heat transfer performance was discussed over dimensionless streamline and temperature contours, as well as quantified by average Nusselt numbers (Nu). The numerical outcomes revealed that the curvature of side walls have significant effects on buoyancy-driven fluid flow and heat transfer. The fluid flow was squeezed and restricted in concave enclosures, particularly at high Ra, while double longitudinal circulations were generally formed in convex enclosures. Hence, utilization of concave enclosures led to a significant decrease in Nu, approaching 45%, while the convex-shaped enclosures resulted in a remarkable improvement in Nu, which can reach up to 18.6% depending on the Ra, compared to the reference enclosure. Regarding the outcomes of the work, convex-structured enclosures were found to be superior for enhancing heat transfer and were recommended for engineering applications such as cooling of electronics, solar thermal energy and relevant heat exchangers.
- 8 November 2025
- Published by Elsevier in Thermal Science and Engineering Progress
- Vol. 68
Effect of ultrasonic frequency and power on PCM solidification: An experimental assessment
- 8 November 2025
- Published by Elsevier in Thermal Science and Engineering Progress
- Vol. 68
Effect of ultrasonic frequency and power on PCM solidification: An experimental assessment
- Open Access
- 2 February 2025
- Published by Union of Mechanical and Electrotechnical Engineers and Technicians of Serbia (SMEITS)
- Vol. 55 (1) , 145-154
Assessment of thermal energy storage unit coupled with air-source heat pump
Coupling thermal energy storage systems to heat pumps is an effective way to manage the utilization of thermal energy with respect to its demand. In this work, a thermal energy storage (TES) unit consisting of water and phase change material (PCM) was investigated experimentally by a laboratory scale test rig where lauric acid was used as PCM. The experiments were conducted for the cases including only water inside the TES unit and for those involving water and PCM inside the TES unit, separately. Using the data obtained from the experiments as well as by the knowledge of the system operation, a numerical model was established via grey-box modeling approach. Developed model allowed to investigate an impact of various PCMs and different effective thermal conductivity values of PCMs on the heating times, as well as the load shifting potential, in consideration of four different heating loads. The experimental results showed that incorporation of lauric acid into the TES unit resulted in lower heating times by 16% during thermal discharge; however, its inclusion improved the coefficient of performance significantly. Furthermore, the load shifting index was also improved by 10% using PCM, instead of using water only. Numerical outcomes revealed that using PCMs with high latent heat capacity and with a phase change temperature around the mean of the lowest and highest water storage temperatures could help achieving longer heating time (~4%) during discharge. Besides, load shifting could be enhanced using the aforementioned PCM (RT44HC). Consequently, it was deduced that the low thermal conductivity of PCMs is significant challenge for thermal energy storage. The heat transfer enhancement implementations are strongly recommended to achieve further improvement in the aforementioned performance parameters.
- 2 February 2025
- Published by Union of Mechanical and Electrotechnical Engineers and Technicians of Serbia (SMEITS)
- Vol. 55 (1) , 145-154
Open AccessAssessment of thermal energy storage unit coupled with air-source heat pump
Coupling thermal energy storage systems to heat pumps is an effective way to manage the utilization of thermal energy with respect to its demand. In this work, a thermal energy storage (TES) unit consisting of water and phase change material (PCM) was investigated experimentally by a laboratory scale test rig where lauric acid was used as PCM. The experiments were conducted for the cases including only water inside the TES unit and for those involving water and PCM inside the TES unit, separately. Using the data obtained from the experiments as well as by the knowledge of the system operation, a numerical model was established via grey-box modeling approach. Developed model allowed to investigate an impact of various PCMs and different effective thermal conductivity values of PCMs on the heating times, as well as the load shifting potential, in consideration of four different heating loads. The experimental results showed that incorporation of lauric acid into the TES unit resulted in lower heating times by 16% during thermal discharge; however, its inclusion improved the coefficient of performance significantly. Furthermore, the load shifting index was also improved by 10% using PCM, instead of using water only. Numerical outcomes revealed that using PCMs with high latent heat capacity and with a phase change temperature around the mean of the lowest and highest water storage temperatures could help achieving longer heating time (~4%) during discharge. Besides, load shifting could be enhanced using the aforementioned PCM (RT44HC). Consequently, it was deduced that the low thermal conductivity of PCMs is significant challenge for thermal energy storage. The heat transfer enhancement implementations are strongly recommended to achieve further improvement in the aforementioned performance parameters.