Mustafa Seçilmiş
Mustafa Seçilmiş has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Çağatay Yıldız
Mechanical Engineering Department, Engineering Faculty, Kocaeli University 1 , İzmit, 41001 Kocaeli
4 shared publications Dong Li
3 shared publicationsMüslüm Arıcı
2 shared publications- Sandro Nižetić
University of Split
2 shared publications - Amin Shahsavar
Kermanshah University of Technology
1 shared publication - Ekrem Tunçbilek
Kocaeli Üniversitesi
1 shared publication
Latest Publications
- Open Access
- 2 February 2025
- Published by Union of Mechanical and Electrotechnical Engineers and Technicians of Serbia (SMEITS)
- Vol. 55 (1) , 145-154
Assessment of thermal energy storage unit coupled with air-source heat pump
Coupling thermal energy storage systems to heat pumps is an effective way to manage the utilization of thermal energy with respect to its demand. In this work, a thermal energy storage (TES) unit consisting of water and phase change material (PCM) was investigated experimentally by a laboratory scale test rig where lauric acid was used as PCM. The experiments were conducted for the cases including only water inside the TES unit and for those involving water and PCM inside the TES unit, separately. Using the data obtained from the experiments as well as by the knowledge of the system operation, a numerical model was established via grey-box modeling approach. Developed model allowed to investigate an impact of various PCMs and different effective thermal conductivity values of PCMs on the heating times, as well as the load shifting potential, in consideration of four different heating loads. The experimental results showed that incorporation of lauric acid into the TES unit resulted in lower heating times by 16% during thermal discharge; however, its inclusion improved the coefficient of performance significantly. Furthermore, the load shifting index was also improved by 10% using PCM, instead of using water only. Numerical outcomes revealed that using PCMs with high latent heat capacity and with a phase change temperature around the mean of the lowest and highest water storage temperatures could help achieving longer heating time (~4%) during discharge. Besides, load shifting could be enhanced using the aforementioned PCM (RT44HC). Consequently, it was deduced that the low thermal conductivity of PCMs is significant challenge for thermal energy storage. The heat transfer enhancement implementations are strongly recommended to achieve further improvement in the aforementioned performance parameters.
- 2 February 2025
- Published by Union of Mechanical and Electrotechnical Engineers and Technicians of Serbia (SMEITS)
- Vol. 55 (1) , 145-154
Open AccessAssessment of thermal energy storage unit coupled with air-source heat pump
Coupling thermal energy storage systems to heat pumps is an effective way to manage the utilization of thermal energy with respect to its demand. In this work, a thermal energy storage (TES) unit consisting of water and phase change material (PCM) was investigated experimentally by a laboratory scale test rig where lauric acid was used as PCM. The experiments were conducted for the cases including only water inside the TES unit and for those involving water and PCM inside the TES unit, separately. Using the data obtained from the experiments as well as by the knowledge of the system operation, a numerical model was established via grey-box modeling approach. Developed model allowed to investigate an impact of various PCMs and different effective thermal conductivity values of PCMs on the heating times, as well as the load shifting potential, in consideration of four different heating loads. The experimental results showed that incorporation of lauric acid into the TES unit resulted in lower heating times by 16% during thermal discharge; however, its inclusion improved the coefficient of performance significantly. Furthermore, the load shifting index was also improved by 10% using PCM, instead of using water only. Numerical outcomes revealed that using PCMs with high latent heat capacity and with a phase change temperature around the mean of the lowest and highest water storage temperatures could help achieving longer heating time (~4%) during discharge. Besides, load shifting could be enhanced using the aforementioned PCM (RT44HC). Consequently, it was deduced that the low thermal conductivity of PCMs is significant challenge for thermal energy storage. The heat transfer enhancement implementations are strongly recommended to achieve further improvement in the aforementioned performance parameters.