JOJoshua Ottaway

Joshua Ottaway

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Joshua Ottaway has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Classification and Peroxide Value Prediction of Naturally Aged Edible Oils Using Raman and Infrared Spectral Analysis

    by William E. Gilbraith, J. Chance Carter, Kristl Adams, Isio Sota-Uba, Barry K. Lavine, Karl S. Booksh, Joshua M. Ottaway

    Developing global classification and calibration models for identifying edible oil type and predicting peroxide value, a measure of the degree of oxidation directly related to oil freshness is predicated on capturing variance differences within and between growing seasons across a large set of 19 naturally aged (5–7 years) oil types. Our approach utilizes a larger sample set and longer aging period than reported studies (typically 2–5 years), includes multiple growing seasons, and is based on natural rather than accelerated thermal aging of oil samples. We provide spectroscopic data (Raman scattering, near- and mid-infrared absorption) for 19 edible oil types, which represent the most diverse and only naturally aged sample set reported to date. The data, which consist of three data collection campaigns acquired using different analytical methods at different times during the aging process, provide opportunities to investigate and validate new machine learning approaches for classification, calibration, and data fusion. In the supplemental material, vibrational spectroscopy data from all samples are included along with the R programming language code for preprocessing data and building basic classification and calibration models.


  • Open Access

    Radiolysis of Organic Solvents in the Presence of Plutonium

    by M. Zavarin, P. Zhao, M. Lane, J. Oakdale, E. Balboni, K. Morrison, J M Ottaway, K. Blobaum

    The U.S. Department of Energy's Office of Scientific and Technical Information

  • Open Access

    Standoff Detection of Oil and Powder Mixtures at 12 Meters Using a Tunable Quantum Cascade Laser-Based System with a Close Focus Telescope and Uncooled Infrared Detector

    by J. Chance Carter, Phillip H. Paul, Joshua M. Ottaway, Peter Haugen, Anastacia M. Manuel

    We have designed and demonstrated a quantum cascade laser (QCL) based standoff system that utilizes an uncooled mercury cadmium telluride (MCT) detector with lock-in signal processing for chemical identification at a distance of 12.5 meters in indoor ambient light conditions. In the system, a tunable quad-QCL operating (1 MHz) in quasi-continuous wave mode between 8.45 and 10.03 μm (∼1182 to 1000 cm −1 ) serves as the active mid-infrared source for remotely interrogating mineral, powder, and thin film oil samples including powder mixtures (6, 12.5, 25, and 50%) of crystalline quartz (SiO 2 ) in KBr. Light as reflected from a given sample is collected using a 10-inch (25.4 cm) Dall Kirkham telescope and coupled with ZnSe optics to an uncooled MCT detector. The mixture dependence of the highly transparent KBr and strongly absorbing quartz was found to fit a modified version of the Schatz reflectance model for compacted powder mixtures. All reflectance spectra reported are relative to an Au-coated diffuse reflector. A NIST traceable polystyrene standard reflector was also used to determine the QCL wavelength tuning range and calibration.


  • Open Access

    Differentiation of Edible Oils by Type Using Raman Spectroscopy and Pattern Recognition Methods

    by Francis Kwofie, Barry K. Lavine, Joshua Ottaway, Karl Booksh

    The application of Raman spectroscopy and pattern recognition methods to the problem of discriminating edible oils by type was investigated. Two-hundred and eighty-six Raman spectra obtained from 53 samples spanning 15 varieties of edible oils were collected for 90 s at 2 cm –1 resolution. Employing a Whittaker filter, all Raman spectra were baseline corrected after removing the high-intensity fluorescent background in each spectrum. The Raman spectral data were then examined using the three major types of pattern recognition methodology: mapping and display, discriminant development and clustering. The 15 varieties of edible oils could be partitioned into five distinct groups based on their degree of saturation and the ratio of polyunsaturated fatty acids to monounsaturated fatty acids. Edible oils assigned to one group could be readily differentiated from those assigned to other groups, whereas Raman spectra within the same group more closely resembled each other and therefore would be more difficult to classify by type.


  • Open Access

    Spatial Heterodyne Raman Spectrometer (SHRS) for In Situ Chemical Sensing Using Sapphire and Silica Optical Fiber Raman Probes

    by Joshua M. Ottaway, Ashley Allen, Abigail Waldron, Phillip H. Paul, S. Michael Angel, J. Chance Carter

    A spatial heterodyne Raman spectrometer (SHRS), constructed using a modular optical cage and lens tube system, is described for use with a commercial silica and a custom single-crystal (SC) sapphire fiber Raman probe. The utility of these fiber-coupled SHRS chemical sensors is demonstrated using 532 nm laser excitation for acquiring Raman measurements of solid (sulfur) and liquid (cyclohexane) Raman standards as well as real-world, plastic-bonded explosives (PBX) comprising 1,3,5- triamino- 2,4,6- trinitrobenzene (TATB) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) energetic materials. The SHRS is a fixed grating-based dispersive interferometer equipped with an array detector. Each Raman spectrum was extracted from its corresponding fringe image (i.e., interferogram) using a Fourier transform method. Raman measurements were acquired with the SHRS Littrow wavelength set at the laser excitation wavelength over a spectral range of ∼1750 cm −1 with a spectral resolution of ∼8 cm −1 for sapphire and ∼10 cm −1 for silica fiber probes. The large aperture of the SHRS allows much larger fiber diameters to be used without degrading spectral resolution as demonstrated with the larger sapphire collection fiber diameter (330 μm) compared to the silica fiber (100 μm). Unlike the dual silica fiber Raman probe, the dual sapphire fiber Raman probe did not include filtering at the fiber probe tip nearest the sample. Even so, SC sapphire fiber probe measurements produced less background than silica fibers allowing Raman measurements as close as ∼85 cm −1 to the excitation laser. Despite the short lengths of sapphire fiber used to construct the sapphire probe, well-defined, sharp sapphire Raman bands at 420, 580, and 750 cm −1 were observed in the SHRS spectra of cyclohexane and the highly fluorescent HMX-based PBX. SHRS measurements of the latter produced low background interference in the extracted Raman spectrum because the broad band fluorescence (i.e., a direct current, or DC, component) does not contribute to the interferogram intensity (i.e., the alternating current, or AC, component). SHRS spectral resolution, throughput, and signal-to-noise ratio are also discussed along with the merits of using sapphire Raman bands as internal performance references and as internal wavelength calibration standards in Raman measurements.


  • Incorporating brand variability into classification of edible oils by Raman spectroscopy

    by Francis Kwofie, Barry K. Lavine, Joshua Ottaway, Karl Booksh

    Two‐hundred and fifteen Raman spectra of 15 edible oils or blends of edible oils from 53 samples spanning multiple brands purchased over 3 years were investigated using a genetic algorithm for spectral pattern recognition. Using a hierarchical approach to classification, the 15 edible oils could be divided into two groups based on their degree of unsaturation. While edible oils from any particular batch within a class are well clustered and can be differentiated from other varieties of edible oils that are also from a single source, incorporating uncontrolled variability from sources (by purchasing edible oils under different brand names) and seasons (by purchasing edible oils over a 3‐year period) presented a far more challenging classification problem for edible oils within the same group. The between‐source and yearly variability within one class of edible oils is often comparable to differences between the average spectra of the different varieties of edible oils, thereby preventing either a reliable classification of the edible oils or the detection of adulterants in an edible oil if a single model, spanning all sources and years of oils, is to be constructed. The novelty of this study arises from the incorporation of edible oils gathered systematically over the span of 3 years, introducing a heretofore unseen variance to the chemical compositions of the edible oils that are being classified. This is the first time that many different edible oils and commercially available brands thereof have been classified simultaneously.


  • Raman Microspectroscopic Mapping with Multivariate Curve Resolution–Alternating Least Squares (MCR-ALS) Applied to the High-Pressure Polymorph of Titanium Dioxide, TiO 2 -II

    by Joseph P. Smith, Frank C. Smith, Joshua Ottaway, Alexandra E. Krull-Davatzes, Bruce M. Simonson, Billy P. Glass, Karl S. Booksh

    The high-pressure, α-PbO 2 -structured polymorph of titanium dioxide (TiO 2 -II) was recently identified in micrometer-sized grains recovered from four Neoarchean spherule layers deposited between ∼2.65 and ∼2.54 billion years ago. Several lines of evidence support the interpretation that these layers represent distal impact ejecta layers. The presence of shock-induced TiO 2 -II provides physical evidence to further support an impact origin for these spherule layers. Detailed characterization of the distribution of TiO 2 -II in these grains may be useful for correlating the layers, estimating the paleodistances of the layers from their source craters, and providing insight into the formation of the TiO 2 -II. Here we report the investigation of TiO 2 -II-bearing grains from these four spherule layers using multivariate curve resolution–alternating least squares (MCR-ALS) applied to Raman microspectroscopic mapping. Raman spectra provide evidence of grains consisting primarily of rutile (TiO 2 ) and TiO 2 -II, as shown by Raman bands at 174 cm –1 (TiO 2 -II), 426 cm –1 (TiO 2 -II), 443 cm –1 (rutile), and 610 cm –1 (rutile). Principal component analysis (PCA) yielded a predominantly three-phase system comprised of rutile, TiO 2 -II, and substrate-adhesive epoxy. Scanning electron microscopy (SEM) suggests heterogeneous grains containing polydispersed micrometer- and submicrometer-sized particles. Multivariate curve resolution–alternating least squares applied to the Raman microspectroscopic mapping yielded up to five distinct chemical components: three phases of TiO 2 (rutile, TiO 2 -II, and anatase), quartz (SiO 2 ), and substrate-adhesive epoxy. Spectral profiles and spatially resolved chemical maps of the pure chemical components were generated using MCR-ALS applied to the Raman microspectroscopic maps. The spatial resolution of the Raman microspectroscopic maps was enhanced in comparable, cost-effective analysis times by limiting spectral resolution and optimizing spectral acquisition parameters. Using the resolved spectra of TiO 2 -II generated from MCR-ALS analysis, a Raman spectrum for pure TiO 2 -II was estimated to further facilitate its identification.


  • Feasibility Study for Transforming Spectral and Instrumental Artifacts for Multivariate Calibration Maintenance

    by Joshua Ottaway, John H. Kalivas

    Frequently, a spectral-based multivariate calibration model formed on a particular instrument (primary) needs to predict samples measured on other (secondary) instruments of the same spectral type. This situation is often referred to as calibration maintenance or transfer. A new calibration maintenance approach is developed in this paper using spectral differences between instruments. In conjunction with a sample weighting scheme, spectral differences are piecewise (wavelength window) or full spectrum fitted with modeling terms (correction terms) such as polynomials and derivatives. Results demonstrating the potential usefulness of the new method using a near infrared (NIR) benchmark dataset are presented in this paper. The process does not need a standardization sample set measured in the primary condition. Thus, the new approach is a “hybrid” between the popular methods of extended inverted multiplicative signal correction (EISC) and direct standardization (DS) or piecewise DS (PDS). It is found that prediction errors reduce for samples measured in the secondary condition compared to those based on no calibration transfer. Prediction errors are also comparable to those from a full calibration in the secondary condition. In addition to instrument correction, an extension of the new approach is discussed (but not tested) for predicting new samples changing over time due to new chemical, physical, and environmental measurement conditions including individually or combinations of temperature, sample particle size, and new spectrally responding species.


  • Adaptive Regression via Subspace Elimination

    by Joshua Ottaway, Joseph P. Smith, Karl S. Booksh

  • Spectral Multivariate Calibration without Laboratory Prepared or Determined Reference Analyte Values

    by Josh Ottaway, Jeremy A. Farrell, John H. Kalivas

    An essential part to calibration is establishing the analyte calibration reference samples. These samples must characterize the sample matrix and measurement conditions (chemical, physical, instrumental, and environmental) of any sample to be predicted. Calibration usually requires measuring spectra for numerous reference samples in addition to determining the corresponding analyte reference values. Both tasks are typically time-consuming and costly. This paper reports on a method named pure component Tikhonov regularization (PCTR) that does not require laboratory prepared or determined reference values. Instead, an analyte pure component spectrum is used in conjunction with nonanalyte spectra for calibration. Nonanalyte spectra can be from different sources including pure component interference samples, blanks, and constant analyte samples. The approach is also applicable to calibration maintenance when the analyte pure component spectrum is measured in one set of conditions and nonanalyte spectra are measured in new conditions. The PCTR method balances the trade-offs between calibration model shrinkage and the degree of orthogonality to the nonanalyte content (model direction) in order to obtain accurate predictions. Using visible and near-infrared (NIR) spectral data sets, the PCTR results are comparable to those obtained using ridge regression (RR) with reference calibration sets. The flexibility of PCTR also allows including reference samples if such samples are available.