IOI. Olcina

I. Olcina

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


I. Olcina has a total of 789 co-authors. Here are the top co-authors by number of shared publications:

  • D. N. McKinsey

    Lawrence Berkeley National Laboratory (LBNL)

    3 shared publications
  • A Ames

    SLAC National Accelerator Laboratory, Menlo Park, CA 94025-7015, United States of America

    2 shared publications
  • A Baker

    11Department of Physics, Imperial College London, Blackett Laboratory, London SW7 2AZ, United Kingdom

    2 shared publications
  • A Bhatti

    16Department of Physics, University of Maryland, College Park, MD 20742-4111, United States of America

    2 shared publications
  • A Chawla

    40Department of Physics, Royal Holloway, University of London, Egham, TW20 0EX, United Kingdom

    2 shared publications
  • A Cottle

    Department of Physics and Astronomy, University College London (UCL), London WC1E 6BT, United Kingdom

    2 shared publications

Latest Publications

  • Open Access

    Neutrinoless double beta decay sensitivity of the XLZD rare event observatory

    by J Aalbers, K Abe, M Adrover, S Ahmed Maouloud, D S Akerib, A K Al Musalhi, F Alder, L Althueser, D W P Amaral, C S Amarasinghe, et al.

    The XLZD collaboration is developing a two-phase xenon time projection chamber with an active mass of 60–80 t capable of probing the remaining weakly interacting massive particle-nucleon interaction parameter space down to the so-called neutrino fog. In this work we show that, based on the performance of currently operating detectors using the same technology and a realistic reduction of radioactivity in detector materials, such an experiment will also be able to competitively search for neutrinoless double beta decay in 136Xe using a natural-abundance xenon target. XLZD can reach a 3σ discovery potential half-life of 5.7 × 1027 years (and a 90% CL exclusion of 1.3 × 1028 years) with 10 years of data taking, corresponding to a Majorana mass range of 7.3–31.3 meV (4.8–20.5 meV). XLZD will thus exclude the inverted neutrino mass ordering parameter space and will start to probe the normal ordering region for most of the nuclear matrix elements commonly considered by the community.


  • Open Access

    New constraints on ultraheavy dark matter from the LZ experiment

    by J. Aalbers, D. S. Akerib, A. K. Al Musalhi, F. Alder, C. S. Amarasinghe, A. Ames, T. J. Anderson, N. Angelides, H. M. Araújo, J. E. Armstrong, et al.

    Searches for dark matter with liquid xenon time projection chamber experiments have traditionally focused on the region of the parameter space that is characteristic of weakly interacting massive particles, ranging from a few GeV/c2 to a few TeV/c2. Models of dark matter with a mass much heavier than this are well motivated by early production mechanisms different from the standard thermal freeze-out, but they have generally been less explored experimentally. In this work, we present a reanalysis of the first science run of the LZ experiment, with an exposure of 0.9  tonne×yr, to search for ultraheavy particle dark matter. The signal topology consists of multiple energy deposits in the active region of the detector forming a straight line, from which the velocity of the incoming particle can be reconstructed on an event-by-event basis. Zero events with this topology were observed after applying the data selection calibrated on a simulated sample of signal-like events. New experimental constraints are derived, which rule out previously unexplored regions of the dark matter parameter space of spin-independent interactions beyond a mass of 1017  GeV/c2.


  • Open Access

    New constraints on ultraheavy dark matter from the LZ experiment

    by J Aalbers, D Akerib, A Al Musalhi, F Alder, C Amarasinghe, A Ames, T Anderson, N Angelides, H Araújo, J Armstrong, et al.

    Searches for dark matter with liquid xenon time projection chamber experiments have traditionally focused on the region of the parameter space that is characteristic of weakly interacting massive particles, ranging from a few GeV/$c^2$ to a few TeV/$c^2$. Models of dark matter with a mass much heavier than this are well motivated by early production mechanisms different from the standard thermal freeze-out, but they have generally been less explored experimentally. In this work, we present a re-analysis of the first science run (SR1) of the LZ experiment, with an exposure of $0.9$ tonne$\times$year, to search for ultraheavy particle dark matter. The signal topology consists of multiple energy deposits in the active region of the detector forming a straight line, from which the velocity of the incoming particle can be reconstructed on an event-by-event basis. Zero events with this topology were observed after applying the data selection calibrated on a simulated sample of signal-like events. New experimental constraints are derived, which rule out previously unexplored regions of the dark matter parameter space of spin-independent interactions beyond a mass of 10$^{17}$ GeV/$c^2$.

  • Open Access

    Nuclear recoil response of liquid xenon and its impact on solar 8B neutrino and dark matter searches

    by X. Xiang, R. J. Gaitskell, R. Liu, J. Bang, J. Xu, W. H. Lippincott, J. Aalbers, J. E. Y. Dobson, M. Szydagis, G. R. C. Rischbieter, et al.

    Knowledge of the ionization and scintillation responses of liquid xenon (LXe) to nuclear recoils is crucial for LXe-based dark matter experiments. Current calibrations carry large uncertainties in the low-energy region below ∼3  keVnr where signals from dark matter particles of <10  GeV/c2 masses are expected. The coherent elastic neutrino-nucleus scattering (CEνNS) by solar B8 neutrinos also results in a continuum of nuclear recoil events below 3.0  keVnr (99% of events), which further complicates low-mass dark matter searches in LXe experiments. In this paper, we describe a method to quantify the uncertainties of low-energy LXe responses using published calibration data, followed by case studies to evaluate the impact of yield uncertainties on B8 searches and low-mass dark matter sensitivity in a typical ton-scale LXe experiment. We conclude that naively omitting yield uncertainties leads to overly optimistic limits by factor ∼2 for a 6 GeV weakly interacting massive particle mass. Future nuclear recoil light yield calibrations could allow experiments to recover this sensitivity and also improve the accuracy of solar B8 flux measurements.


  • Open Access

    Study of dielectric breakdown in liquid xenon with XeBrA: The xenon breakdown apparatus

    by J. Watson, I. Olcina, J. Soria, D. N. McKinsey, S. Kravitz, E. E. Deck, E. P. Bernard, L. Tvrznikova, W. L. Waldron, Q. Riffard, et al.

    Maintaining the electric fields necessary for the current generation of noble liquid time projection chambers (TPCs), with drift lengths exceeding 1 m, requires a large negative voltage applied to their cathode. Delivering such high voltage is associated with an elevated risk of electrostatic discharge and electroluminescence, which would be detrimental to the performance of the experiment. The Xenon Breakdown Apparatus (XeBrA) is a 5-l, high voltage test chamber built to investigate the contributing factors to electrical breakdown in noble liquids. In this work, we present the main findings after conducting scans over stressed electrode areas, surface finish, pressure, and high voltage ramp speed in the medium of liquid xenon. Area scaling and surface finish were observed to be the dominant factors affecting breakdown, whereas no significant changes were observed with varying pressure or ramp speed. A general rise in both the anode current and photon rate was observed in the last 30 s, leading up to a breakdown, with a marked increase in the last couple of seconds. In addition, the position of breakdowns was reconstructed with a system of high-speed cameras and a moderate correlation with the Fowler–Nordheim field emission model was found. Tentative evidence for bubble nucleation being the originating mechanism of breakdown in the liquid was also observed. We deem the results presented in this work to be of particular interest for the design of future, large TPCs, and practical recommendations are provided.


  • Open Access

    Study of dielectric breakdown in liquid xenon with the XeBrA experiment

    by J. Watson, I. Olcina, J. Soria, D. N. McKinsey, S. Kravitz, E. E. Deck, E. P. Bernard, L. Tvrznikova, W. L. Waldron, Q. Riffard, et al.

    Maintaining the electric fields necessary for the current generation of noble liquid time projection chambers (TPCs), with drift lengths exceeding one meter, requires a large negative voltage applied to their cathode. Delivering such high voltage is associated with an elevated risk of electrostatic discharge and electroluminescence, which would be detrimental to the performance of the experiment. The Xenon Breakdown Apparatus (XeBrA) is a five-liter, high voltage test chamber built to investigate the contributing factors to electrical breakdown in noble liquids. In this work, we present the main findings after conducting scans over stressed electrode areas, surface finish, pressure, and high voltage ramp speed in the medium of liquid xenon. Area scaling and surface finish were observed to be the dominant factors affecting breakdown, whereas no significant changes were observed with varying pressure or ramp speed. A general rise in both anode current and photon rate was observed in the last 30 seconds leading up to a breakdown, with a marked increase in the last couple of seconds. In addition, the position of breakdowns was reconstructed with a system of high-speed cameras and a moderate correlation with the Fowler-Nordheim field emission model was found. Tentative evidence for bubble nucleation being the originating mechanism of breakdown in the liquid was also observed. We deem the results presented in this work to be of particular interest for the design of future, large TPCs, and practical recommendations are provided.

  • Response of photomultiplier tubes to xenon scintillation light

    by B. López Paredes, H.M. Araújo, F. Froborg, N. Marangou, I. Olcina, T.J. Sumner, R. Taylor, A. Tomás, A. Vacheret