Sophinese Iskander-Rizk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sophinese Iskander-Rizk has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Behrooz Fereidoonnezhad
Department of Biomechanical Engineering, Faculty of Mechanical Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, The Netherlands
2 shared publications Antonius F.W. Van der Steen
Department of Cardiology, Erasmus MC University Medical Center Rotterdam, Rotterdam, the Netherlands
1 shared publicationAstrid M. Moerman
Department of Cardiology, Erasmus MC University Medical Center Rotterdam, Rotterdam, the Netherlands
1 shared publication- Bruno Lopez-Rodriguez
Department of Imaging Physics (ImPhys), Faculty of Applied Sciences Delft University of Technology Delft The Netherlands
1 shared publication - Gerard Jan Verbiest
Delft University of Technology
1 shared publication - Gijs van Soest
Erasmus University Medical Center
1 shared publication
Latest Publications
- Open Access
- 1 December 2025
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (1) , 015017
A multiscale framework for in silico thrombus generation and photoacoustic simulations
Thrombus composition and microstructure play a critical role in determining the treatment success for thrombus-related diseases such as ischemic stroke and deep vein thrombosis. However, no in vivo diagnostic method can fully capture thrombus microstructure yet, hindering personalized treatment. Photoacoustic imaging is uniquely positioned to provide information on thrombi composition as it relays optical absorption information from diffuse photons at acoustic propagation depths. Computational modeling enables systematic exploration of microstructural effects on imaging signals, offering insights into developing improved in vivo diagnostic techniques. However, no photoacoustic simulation platform can model microstructural features within centimeter-scale phantoms at reasonable computational cost. In this work, we present recursive iterative fibrin network emulation (REFINE), a topology-driven framework for generating in silico thrombi that replicate their key microstructural traits. Unlike existing methods, REFINE enables controlled, recursive optimization of thrombus topology, making it suitable for accurate photoacoustic modeling and potentially powerful for biomechanical analyses beyond this study. These digital thrombi are embedded into a multiscale photoacoustic simulation platform that bridges microscale acoustic modeling with macroscale thrombus geometries, enabling efficient and realistic simulation of photoacoustic signal responses. We created unique representation of thrombi microstructure for various compositions and porosities. Our simulation framework effectively links microstructural features to macroscale imaging outcomes, in agreement with previous empirical studies. Our simulation results demonstrate that thrombus microstructure significantly affects photoacoustic spectral responses and can be reliably modeled in silico. These findings highlight the potential of a multiscale photoacoustic simulation approach as a powerful tool for characterizing tissue microstructure and demonstrate the utility of our computational framework for in silico thrombi analysis and the development of diagnostic imaging strategies.
- 1 December 2025
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (1) , 015017
Open AccessA multiscale framework for in silico thrombus generation and photoacoustic simulations
Thrombus composition and microstructure play a critical role in determining the treatment success for thrombus-related diseases such as ischemic stroke and deep vein thrombosis. However, no in vivo diagnostic method can fully capture thrombus microstructure yet, hindering personalized treatment. Photoacoustic imaging is uniquely positioned to provide information on thrombi composition as it relays optical absorption information from diffuse photons at acoustic propagation depths. Computational modeling enables systematic exploration of microstructural effects on imaging signals, offering insights into developing improved in vivo diagnostic techniques. However, no photoacoustic simulation platform can model microstructural features within centimeter-scale phantoms at reasonable computational cost. In this work, we present recursive iterative fibrin network emulation (REFINE), a topology-driven framework for generating in silico thrombi that replicate their key microstructural traits. Unlike existing methods, REFINE enables controlled, recursive optimization of thrombus topology, making it suitable for accurate photoacoustic modeling and potentially powerful for biomechanical analyses beyond this study. These digital thrombi are embedded into a multiscale photoacoustic simulation platform that bridges microscale acoustic modeling with macroscale thrombus geometries, enabling efficient and realistic simulation of photoacoustic signal responses. We created unique representation of thrombi microstructure for various compositions and porosities. Our simulation framework effectively links microstructural features to macroscale imaging outcomes, in agreement with previous empirical studies. Our simulation results demonstrate that thrombus microstructure significantly affects photoacoustic spectral responses and can be reliably modeled in silico. These findings highlight the potential of a multiscale photoacoustic simulation approach as a powerful tool for characterizing tissue microstructure and demonstrate the utility of our computational framework for in silico thrombi analysis and the development of diagnostic imaging strategies.
- Open Access
A Multiscale Framework for In Silico Thrombus Generation and Photoacoustic Simulations
Thrombus microstructure plays a critical role in determining the treatment success for thrombus-related diseases such as stroke and deep vein thrombosis. However, no in vivo diagnostic method can fully capture thrombus microstructure yet. Photoacoustic imaging is uniquely positioned to provide information on thrombi composition as it relays optical absorption information from diffuse photons at acoustic propagation depths. Computational modeling enables systematic exploration of microstructural effects on imaging signals, offering insights into developing improved in vivo diagnostic techniques. However, no photoacoustic simulation platform can model microstructural features within centimeter-scale phantoms at reasonable computational cost. Here, we present REFINE, a topology-driven framework for generating in silico thrombi replicating its key replicating their key microstructural traits. REFINE enables controlled, recursive optimization of thrombus topology, making it suitable for accurate photoacoustic modeling and potentially powerful for biomechanical analyses. These digital thrombi are embedded into a multiscale photoacoustic simulation platform that bridges microscale acoustic modeling with macroscale thrombus geometries, enabling efficient and realistic simulation of photoacoustic signal responses. We created unique thrombi microstructure for various compositions and porosities. Our simulation framework effectively links microstructural features to macroscale imaging outcomes, in agreement with previous empirical studies. Our results demonstrate that thrombus microstructure significantly affects photoacoustic spectral responses and can be modeled in silico. These findings highlight that multiscale photoacoustic simulation is a powerful tool for characterizing tissue microstructure and that our framework enables in silico thrombi analysis and diagnostic imaging strategy development
Open AccessA Multiscale Framework for In Silico Thrombus Generation and Photoacoustic Simulations
Thrombus microstructure plays a critical role in determining the treatment success for thrombus-related diseases such as stroke and deep vein thrombosis. However, no in vivo diagnostic method can fully capture thrombus microstructure yet. Photoacoustic imaging is uniquely positioned to provide information on thrombi composition as it relays optical absorption information from diffuse photons at acoustic propagation depths. Computational modeling enables systematic exploration of microstructural effects on imaging signals, offering insights into developing improved in vivo diagnostic techniques. However, no photoacoustic simulation platform can model microstructural features within centimeter-scale phantoms at reasonable computational cost. Here, we present REFINE, a topology-driven framework for generating in silico thrombi replicating its key replicating their key microstructural traits. REFINE enables controlled, recursive optimization of thrombus topology, making it suitable for accurate photoacoustic modeling and potentially powerful for biomechanical analyses. These digital thrombi are embedded into a multiscale photoacoustic simulation platform that bridges microscale acoustic modeling with macroscale thrombus geometries, enabling efficient and realistic simulation of photoacoustic signal responses. We created unique thrombi microstructure for various compositions and porosities. Our simulation framework effectively links microstructural features to macroscale imaging outcomes, in agreement with previous empirical studies. Our results demonstrate that thrombus microstructure significantly affects photoacoustic spectral responses and can be modeled in silico. These findings highlight that multiscale photoacoustic simulation is a powerful tool for characterizing tissue microstructure and that our framework enables in silico thrombi analysis and diagnostic imaging strategy development
- Open Access
Amorphous Silicon-Carbide Photonics for Ultrasound Imaging
Photonic ultrasound sensors offer unparalleled potential for improving spatial and temporal resolution in ultrasound imaging applications due to their size-independent noise figure, high sensitivity, and broad bandwidth characteristics. The exploration of optical materials in ultrasound sensing has attracted significant interest due to their potential to further enhance device performance, fabrication compatibility, and long-term stability. This work introduces amorphous silicon carbide (a-SiC) as a material for optical ultrasound sensing. a-SiC offers a balanced combination of optical confinement, low propagation loss, and high material stability, enabling sensitive and miniaturized microring sensors. We demonstrate a compact ultrasound detection system with a linear array of 20 transducers coupled to a single bus waveguide. The sensors feature a maximum optical finesse of 1320 and an intrinsic platform sensitivity of 78 fm/kPa, leading to a noise equivalent pressure density below 55 $\mathrm{mPa}/\sqrt{\mathrm{Hz}}$, which is calibrated to a hydrophone from 3.36 MHz to 30 MHz. Additionally, we perform high-resolution ultrasound imaging of fine structures, highlighting the viability of these sensors in real-world applications. Moreover, its low deposition temperature allows a-SiC material for optical ultrasound sensors to be integrated on most substrates. These results position a-SiC as a promising material for optical ultrasound sensing, offering a miniaturized, low-loss, and high-sensitivity solution for next-generation photoacoustic imaging applications.Open AccessAmorphous Silicon-Carbide Photonics for Ultrasound Imaging
Photonic ultrasound sensors offer unparalleled potential for improving spatial and temporal resolution in ultrasound imaging applications due to their size-independent noise figure, high sensitivity, and broad bandwidth characteristics. The exploration of optical materials in ultrasound sensing has attracted significant interest due to their potential to further enhance device performance, fabrication compatibility, and long-term stability. This work introduces amorphous silicon carbide (a-SiC) as a material for optical ultrasound sensing. a-SiC offers a balanced combination of optical confinement, low propagation loss, and high material stability, enabling sensitive and miniaturized microring sensors. We demonstrate a compact ultrasound detection system with a linear array of 20 transducers coupled to a single bus waveguide. The sensors feature a maximum optical finesse of 1320 and an intrinsic platform sensitivity of 78 fm/kPa, leading to a noise equivalent pressure density below 55 $\mathrm{mPa}/\sqrt{\mathrm{Hz}}$, which is calibrated to a hydrophone from 3.36 MHz to 30 MHz. Additionally, we perform high-resolution ultrasound imaging of fine structures, highlighting the viability of these sensors in real-world applications. Moreover, its low deposition temperature allows a-SiC material for optical ultrasound sensors to be integrated on most substrates. These results position a-SiC as a promising material for optical ultrasound sensing, offering a miniaturized, low-loss, and high-sensitivity solution for next-generation photoacoustic imaging applications. - Open Access
- 1 June 2021
- Published by Elsevier in Photoacoustics
- Vol. 22, 100261
Micro Spectroscopic Photoacoustic (μsPA) imaging of advanced carotid atherosclerosis
- 1 June 2021
- Published by Elsevier in Photoacoustics
- Vol. 22, 100261
Open AccessMicro Spectroscopic Photoacoustic (μsPA) imaging of advanced carotid atherosclerosis