Loreta Vallja
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Loreta Vallja has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Nevila Broli
Department of Chemistry, Faculty of Natural Sciences, University of Tirana, Tirana, Albania and NanoAlb, Center of Nanomaterials and Nanotechnology, Academy of Science of Albania, Tirana, Albania
3 shared publications - Majlinda Vasjari
Department of Chemistry Faculty of Natural Sciences University of Tirana Tiranë 1000 Albania
2 shared publications - Sadik Cenolli
Department of Chemistry, Faculty of Natural Sciences, University of Tirana, Tirana, Albania and NanoAlb, Center of Nanomaterials and Nanotechnology, Academy of Science of Albania, Tirana, Albania
2 shared publications - Alma Shehu
Tirana University, Faculty of Natural Sciences, Department of Chemistry, Tirana, Albania
1 shared publication - Ana Ameda
Department of Chemistry, Faculty of Natural Sciences, University of Tirana, Tirana, Albania and NanoAlb, Center of Nanomaterials and Nanotechnology, Academy of Science of Albania, Tirana, Albania
1 shared publication - Lueda Kulla
Department of Chemistry Faculty of Natural Sciences University of Tirana Tiranë 1000 Albania
1 shared publication
Latest Publications
- Open Access
- 5 April 2026
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 16
Rapid and sensitive electrochemical determination of phosphate ions using a multi-walled carbon nanotube carbon paste electrode
Phosphates are widely used in food as texture modifiers, preservatives and flavour enhancers, while excessive intake may negatively affect human health and the environment. Consequently, there is a growing demand for low-cost, portable, and reliable tools for phosphate monitoring in food and water samples. In this work, an electrochemical sensor based on a multi-walled carbon nanotube (MWCNT) modified carbon paste electrode (CPE) was developed for phosphate determination. Phosphate detection was based on the electrochemical reduction of an electroactive phosphomolybdate complex formed in acidic medium (50 mM sulfuric acid). Key analytical parameters, including solution acidity and complexation time, were optimized to enhance sensor performance. Carbon nanotube modification significantly enhanced the electrochemical response. While the bare CPE shows weak, poorly defined redox peaks due to limited electron transfer and low surface area, MWCNT-modified CPE exhibits well-defined peaks with ~6-fold higher current, reflecting improved sensitivity, faster electron transfer, and better peak separation. Using square-wave voltammetry, the sensor exhibited a linear response in the phosphate concentration range of 3.1 to 21.7 mg L⁻¹, with a detection limit of 0.03 mg L⁻¹ and a response time of approximately 10 s. The sensor was successfully applied to real sausage samples, yielding recoveries of 94.6 to 97.2 % with relative standard deviation values below 5 %. The presented MWCNT-CPE sensor provides a cost-effective, portable and simple device for fast and reliable in situ detection of phosphate in food and water samples.
- 5 April 2026
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 16
Open AccessRapid and sensitive electrochemical determination of phosphate ions using a multi-walled carbon nanotube carbon paste electrode
Phosphates are widely used in food as texture modifiers, preservatives and flavour enhancers, while excessive intake may negatively affect human health and the environment. Consequently, there is a growing demand for low-cost, portable, and reliable tools for phosphate monitoring in food and water samples. In this work, an electrochemical sensor based on a multi-walled carbon nanotube (MWCNT) modified carbon paste electrode (CPE) was developed for phosphate determination. Phosphate detection was based on the electrochemical reduction of an electroactive phosphomolybdate complex formed in acidic medium (50 mM sulfuric acid). Key analytical parameters, including solution acidity and complexation time, were optimized to enhance sensor performance. Carbon nanotube modification significantly enhanced the electrochemical response. While the bare CPE shows weak, poorly defined redox peaks due to limited electron transfer and low surface area, MWCNT-modified CPE exhibits well-defined peaks with ~6-fold higher current, reflecting improved sensitivity, faster electron transfer, and better peak separation. Using square-wave voltammetry, the sensor exhibited a linear response in the phosphate concentration range of 3.1 to 21.7 mg L⁻¹, with a detection limit of 0.03 mg L⁻¹ and a response time of approximately 10 s. The sensor was successfully applied to real sausage samples, yielding recoveries of 94.6 to 97.2 % with relative standard deviation values below 5 %. The presented MWCNT-CPE sensor provides a cost-effective, portable and simple device for fast and reliable in situ detection of phosphate in food and water samples.
- 22 January 2026
- Published by IJEES in International journal of ecosystems and ecology science (IJEES)
- Vol. 16 (1) , 101-108
AWARENESS OF NITRITE AND PHOSPHATE PRESERVATIVES IN PROCESSED MEAT PRODUCTS: A QUANTITATIVE ASSESSMENT IN ALBANIA
- 22 January 2026
- Published by IJEES in International journal of ecosystems and ecology science (IJEES)
- Vol. 16 (1) , 101-108
AWARENESS OF NITRITE AND PHOSPHATE PRESERVATIVES IN PROCESSED MEAT PRODUCTS: A QUANTITATIVE ASSESSMENT IN ALBANIA
- Open Access
- 20 January 2026
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- p. 3150
Electrochemical sensing of atenolol using silver-reduced graphene oxide carbon paste nanocomposite electrode
Atenolol, one of the most prescribed β₁-selective adrenergic blockers, has been increasingly detected in aquatic ecosystems due to incomplete elimination in sewage treatment plants, posing an ecotoxicological hazard to the environment. Here, an electrochemical sensor based on silver-decorated reduced graphene oxide composite carbon paste electrode (rGO@Ag-CPE) was designed for the ultrasensitive electroanalytical determination of atenolol in real-world samples. The morphology and chemical composition of rGO@Ag-CPE were investigated by transmission electron microscopy and energy-dispersive spectroscopy analyses, while the electrochemical properties were evaluated by cyclic and square wave voltammetry techniques. The rGO@Ag-CPE demonstrated excellent electrocatalytic performance toward Atenolol oxidation, attributed to the unique properties of reduced graphene oxide and silver nanoparticles, which provide high conductivity and efficient electrocatalysis, thereby helping to prevent unwanted Atenolol degradation. Under optimized electrochemical sensing conditions, the rGO@Ag-CPE sensor exhibited a linear dynamic range of 20-859 μM (R² = 0.9953), a low detection limit of 2.9 μM, and good reproducibility (relative standard deviation < 4.0 %). A validation study on real-world samples showed good atenolol recovery of 88.8-102% in natural waters and 97-99.2 % in pharmaceutical tablets.
- 20 January 2026
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- p. 3150
Open AccessElectrochemical sensing of atenolol using silver-reduced graphene oxide carbon paste nanocomposite electrode
Atenolol, one of the most prescribed β₁-selective adrenergic blockers, has been increasingly detected in aquatic ecosystems due to incomplete elimination in sewage treatment plants, posing an ecotoxicological hazard to the environment. Here, an electrochemical sensor based on silver-decorated reduced graphene oxide composite carbon paste electrode (rGO@Ag-CPE) was designed for the ultrasensitive electroanalytical determination of atenolol in real-world samples. The morphology and chemical composition of rGO@Ag-CPE were investigated by transmission electron microscopy and energy-dispersive spectroscopy analyses, while the electrochemical properties were evaluated by cyclic and square wave voltammetry techniques. The rGO@Ag-CPE demonstrated excellent electrocatalytic performance toward Atenolol oxidation, attributed to the unique properties of reduced graphene oxide and silver nanoparticles, which provide high conductivity and efficient electrocatalysis, thereby helping to prevent unwanted Atenolol degradation. Under optimized electrochemical sensing conditions, the rGO@Ag-CPE sensor exhibited a linear dynamic range of 20-859 μM (R² = 0.9953), a low detection limit of 2.9 μM, and good reproducibility (relative standard deviation < 4.0 %). A validation study on real-world samples showed good atenolol recovery of 88.8-102% in natural waters and 97-99.2 % in pharmaceutical tablets.
- Open Access
- 20 March 2021
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 33 (4) , 925-929
Seasonal Assessment of Physico-Chemical Parameters and Water Quality Evaluation of Kune-Vaini Lagoon Complex, Lezha, Albania
The evaluation of the water quality of the Kune-Vain lagoon complex with regard to general physico-chemical and chemical parameters was the main focus of the present study. This evaluation was based on the requirement of Council Directive of 18 July 1978 on the “quality of fresh waters needing protection or improvement in order to support fish life”, [78/659/EEC] and the requirement of Council Directive of 3 November 1998 relating to the “quality of water intended for human consumption”, [98/83/EC]. Five sampling stations were selected to successfully perform the water monitoring on the Kune-Vaini lagoon complex with a frequency of every two months, from July, 2018- July, 2019. The parameters measured were temperature, pH, conductivity, salinity, DO, BOD, TDS, total hardness, Ca2+, Mg2+, Cl– and some heavy metals. The monitored lagoons have shown notable differences based on physico-chemical parameters.
- 20 March 2021
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 33 (4) , 925-929
Open AccessSeasonal Assessment of Physico-Chemical Parameters and Water Quality Evaluation of Kune-Vaini Lagoon Complex, Lezha, Albania
The evaluation of the water quality of the Kune-Vain lagoon complex with regard to general physico-chemical and chemical parameters was the main focus of the present study. This evaluation was based on the requirement of Council Directive of 18 July 1978 on the “quality of fresh waters needing protection or improvement in order to support fish life”, [78/659/EEC] and the requirement of Council Directive of 3 November 1998 relating to the “quality of water intended for human consumption”, [98/83/EC]. Five sampling stations were selected to successfully perform the water monitoring on the Kune-Vaini lagoon complex with a frequency of every two months, from July, 2018- July, 2019. The parameters measured were temperature, pH, conductivity, salinity, DO, BOD, TDS, total hardness, Ca2+, Mg2+, Cl– and some heavy metals. The monitored lagoons have shown notable differences based on physico-chemical parameters.