NZNing Zhang

Ning Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ning Zhang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Factor Analysis on Integrated Error Model of Magnetic Gradient Tensor

    by Lei Xu, Ning Zhang, Ming Chang, Huadong Chen, Chunsheng Lin, Pengfei Lin

    In order to comprehensively analyze the effect of error factors on the magnetic gradient tensor, an integrated error model of the magnetic gradient tensor is established. It integrates five error factors, including three-axis non-orthogonal (TANO), three-axis sensitivity inconsistency (TASI), zero offset (ZO), coordinate system misalignment (CSM) and three-axis non-common point (TANCP). In addition, an iterative orthogonal experiment method is proposed to analyze the values of error caused by these factors and determine the calibration priority of all factors. The simulation result shows that the five error factors on the magnetic tensor from great to small is: TASI, TANO, CSM, ZO, TANCP. At the same time, the error factor which has a greater effect has a higher calibration priority level. When the circumstances occur, in which not all errors need be calibrated, error factors with higher priority should be calibrated first.


  • Open Access

    Simulation Analysis of Magnetic Gradient Full-Tensor Measurement System

    by Lei Xu, Ning Zhang, Liqing Fang, Huadong Chen, Pengfei Lin, Chunsheng Lin

    The magnetic gradient full-tensor measurement system is diverse, and the magnetometer array structure is complex. Aimed at the problem, seven magnetic gradient full-tensor measurement system models are studied in detail. The full-tensor measurement theories of the tensor measurement arrays are analyzed. Under the same baseline distance, the magnetic dipole model is used to simulate the measurement system. Based on different measurement systems, the paper quantitatively compares and analyzes the error of the structure. A more optimized magnetic gradient full-tensor measurement system is suggested. The simulation results show that the measurement accuracy of the planar measurement system is slightly higher than that of the stereo measurement system. Among them, the cross-shaped and square measurement systems have relatively smaller structural errors and higher measurement accuracy.