CLChunsheng Lin

Chunsheng Lin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chunsheng Lin has a total of 29 co-authors. Here are the top co-authors by number of shared publications:

  • Lei Xu

    College of Weapons Engineering, Naval University of Engineering, Wuhan, China

    3 shared publications
  • Pengfei Lin

    College of Weapons Engineering, Naval University of Engineering, Wuhan, China

    3 shared publications
  • Liqing Fang

    Department of Artillery Engineering, Army Engineering University of PLA, Shijiazhuang 050003, China

    2 shared publications
  • Ming Chang

    College of Weapons Engineering, Naval University of Engineering, Wuhan, China

    2 shared publications
  • Ning Zhang

    College of Weapons Engineering, Naval University of Engineering, Wuhan, China

    2 shared publications
  • Aihua Zhang

    Key Laboratory of Tropical Translational Medicine of Ministry of Education, School of Basic Medical Sciences, Traditional Chinese Medicine Innovation and Translation Laboratory, School of Traditional Chinese Medicine, Engineering Research Center for Hainan Biological Sample Resources of Major Diseases, the First Affiliated Hospital, Key Laboratory of Emergency and Trauma of Ministry of Education, Hainan Medical University, Haikou, China

    1 shared publication

Latest Publications

  • Open Access

    Association between the triglyceride glucose index and obstructive sleep apnea and its symptoms: results from the NHANES

    by Chao Wang, Mengdi Shi, Chunsheng Lin, Jingyi Wang, Liangzhen Xie, Yan Li

    Background: Certain studies have indicated a link between obstructive sleep apnea and insulin resistance in specific populations. To gain more clarity, extensive research involving a broad sample of the overall population is essential. The primary objective of this study was to investigate this correlation by utilizing data from the National Health and Nutrition Examination Survey database. Methods: The analysis incorporated data from the National Health and Nutrition Examination Survey database spanning the time periods from 2005 to 2008 and from 2015 to 2018, with a focus on American adults aged 18 years and older after applying weight adjustments. Key variables such as obstructive sleep apnea, triglyceride glucose index, and various confounding factors were considered. A generalized linear logistic regression model was used to investigate the association between obstructive sleep apnea and the triglyceride glucose index, with additional exploration of the consistency of the results through hierarchical analysis and other techniques. Results: The study included participants aged between 18 and 90 years, with an average age of 46.75 years. Among the total sample, 50.76% were male. The triglyceride glucose index demonstrated a diagnostic capability for obstructive sleep apnea, with an AUC of 0.701 (95% CI: 0.6619–0.688). According to the fully adjusted model, individuals in the fourth quartile of the triglyceride glucose index showed an increased likelihood of having obstructive sleep apnea compared to those in the first quartile (OR: 1.45; 95% CI: 1.02–2.06; P < 0.05). Subgroup analysis indicated that male sex (OR: 2.09; 95% CI: 1.76–2.45; P < 0.05), younger age (OR: 2.83; 95% CI: 2.02–3.96; P < 0.05), white ethnicity (OR: 2.29; 95% CI: 1.93–2.73; P < 0.05), and obesity (OR: 1.54; 95% CI: 1.28–1.85; P < 0.05) were correlated with an elevated risk of OSA. Conclusions: This study demonstrated a strong association between an elevated TG index and OSA. Additionally, the triglyceride glucose index could serve as an independent predictor of obstructive sleep apnea.


  • Detection, mechanisms, and therapeutic implications of oncometabolites

    by Ying Cai, Zhibo Wang, Sifan Guo, Chunsheng Lin, Hong Yao, Qiang Yang, Yan Wang, Xiaodan Yu, Xiaowen He, Wanying Sun, et al.


  • Magnetic Target Linear Location Method Using Two-Point Gradient Full Tensor

    by Lei Xu, Hongcan Gu, Ming Chang, Liqing Fang, Pengfei Lin, Chunsheng Lin

    Presently used magnetic target location methods are greatly affected by geomagnetism and involve complex solution processes. To address these problems, herein, a linear location method based on the two-point magnetic gradient full tensor is proposed. Moreover, the principle of single-point magnetic gradient full tensor positioning is analyzed in detail. Based on this principle, a two-point magnetic gradient full tensor location model is constructed. A linear location method is proposed. Measuring the magnetic gradient full tensor at two locations and using a linear method for the calculation of the positioning model, a more precise location of the magnetic target is achieved. The simulation results show that the proposed method significantly reduces the relative error percentages in the three magnet field directions, with the minimum value being 0.0021% in the X-direction. The maximum X-direction error of the proposed method is reduced by 18.66% compared with that of the single-point magnetic gradient full tensor positioning method. In addition, the positioning accuracy of the method is experimentally verified. The Z-direction error value is reduced to 5.48%.


  • Factor Analysis on Integrated Error Model of Magnetic Gradient Tensor

    by Lei Xu, Ning Zhang, Ming Chang, Huadong Chen, Chunsheng Lin, Pengfei Lin

    In order to comprehensively analyze the effect of error factors on the magnetic gradient tensor, an integrated error model of the magnetic gradient tensor is established. It integrates five error factors, including three-axis non-orthogonal (TANO), three-axis sensitivity inconsistency (TASI), zero offset (ZO), coordinate system misalignment (CSM) and three-axis non-common point (TANCP). In addition, an iterative orthogonal experiment method is proposed to analyze the values of error caused by these factors and determine the calibration priority of all factors. The simulation result shows that the five error factors on the magnetic tensor from great to small is: TASI, TANO, CSM, ZO, TANCP. At the same time, the error factor which has a greater effect has a higher calibration priority level. When the circumstances occur, in which not all errors need be calibrated, error factors with higher priority should be calibrated first.


  • Open Access

    Simulation Analysis of Magnetic Gradient Full-Tensor Measurement System

    by Lei Xu, Ning Zhang, Liqing Fang, Huadong Chen, Pengfei Lin, Chunsheng Lin

    The magnetic gradient full-tensor measurement system is diverse, and the magnetometer array structure is complex. Aimed at the problem, seven magnetic gradient full-tensor measurement system models are studied in detail. The full-tensor measurement theories of the tensor measurement arrays are analyzed. Under the same baseline distance, the magnetic dipole model is used to simulate the measurement system. Based on different measurement systems, the paper quantitatively compares and analyzes the error of the structure. A more optimized magnetic gradient full-tensor measurement system is suggested. The simulation results show that the measurement accuracy of the planar measurement system is slightly higher than that of the stereo measurement system. Among them, the cross-shaped and square measurement systems have relatively smaller structural errors and higher measurement accuracy.