Kevin Knappe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kevin Knappe has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Sebastian Jaeger
Research Center of Biomechanics and Implant Technology, Heidelberg University Hospital, Heidelberg, Germany
8 shared publications - Mareike Schonhoff
Research Center of Biomechanics and Implant Technology, Heidelberg University Hospital, Heidelberg, Germany
6 shared publications - Tobias Renkawitz
Department of Orthopaedics, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany
6 shared publications - Andre Lunz
Department of Orthopaedics Heidelberg University Hospital, Ruprecht‐Karls‐University Heidelberg Heidelberg Germany
4 shared publications - Moritz Maximilian Innmann
Orthopädische Universitätsklinik Heidelberg, Heidelberg, Deutschland
4 shared publications - Burkhard Lehner
Department of Orthopaedics, Heidelberg University Hospital, Heidelberg, Germany
3 shared publications
Latest Publications
- Open Access
- 12 September 2026
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 27 (1)
Impact of surface structuring on antibiotic elution from bone cement in two-stage revision for periprosthetic joint infection
Purpose: Periprosthetic joint infection (PJI) is a serious complication after total joint arthroplasty and the leading cause of revision surgery. Two-stage revision with prosthesis removal, radical debridement, and interim antibiotic-loaded bone cement (ALBC) spacers is the current gold standard. ALBC spacers provide high local antibiotic concentrations and maintain joint space, with articulating designs improving interim mobility. Antibiotic release depends on cement composition, antibiotic content, and surface area, but the impact of surface structure remains unclear. This study investigated how surface morphology and area affect gentamicin and vancomycin release from ALBC in vitro. Methods: Copal G + V cement (2 g vancomycin, 0.5 g gentamicin per 43 g) was cast into standardized rectangular blocks according to DIN ISO 5833. A reference group without surface structuring and three groups with progressively increasing surface area and depth were analyzed. After polymerization, specimens were incubated in phosphate-buffered saline at 37 °C. Antibiotic release was measured at defined intervals over six weeks using chemiluminescence immunoassay (CLIA). Results: Surface structuring resulted in a clear increase in cumulative antibiotic release, particularly for vancomycin, with a consistent relationship between surface enlargement and total elution. The greatest surface structuring led to the highest release levels. Gentamicin showed a similar but less pronounced response, with a notable increase only at the highest degree of surface enlargement. The initial burst release contributed substantially to overall elution, while later-phase release differences between groups were less marked. Conclusion: Surface modification of PMMA cement influenced antibiotic elution in this in vitro experimental model, with increased surface depth resulting in enhanced vancomycin release. Gentamicin elution was less affected by surface geometry and showed significant improvement only with the greatest surface enlargement. These findings indicate that structured cement surfaces may influence local antibiotic release characteristics under controlled laboratory conditions. However, the clinical relevance of these surface modifications remains to be determined, as this study was limited to cement blocks incubated in phosphate-buffered saline and did not include a spacer, infection, or in vivo model. Further experimental and in vivo investigations are required to assess whether surface structuring can improve antibiotic delivery in clinically relevant settings.
- 12 September 2026
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 27 (1)
Open AccessImpact of surface structuring on antibiotic elution from bone cement in two-stage revision for periprosthetic joint infection
Purpose: Periprosthetic joint infection (PJI) is a serious complication after total joint arthroplasty and the leading cause of revision surgery. Two-stage revision with prosthesis removal, radical debridement, and interim antibiotic-loaded bone cement (ALBC) spacers is the current gold standard. ALBC spacers provide high local antibiotic concentrations and maintain joint space, with articulating designs improving interim mobility. Antibiotic release depends on cement composition, antibiotic content, and surface area, but the impact of surface structure remains unclear. This study investigated how surface morphology and area affect gentamicin and vancomycin release from ALBC in vitro. Methods: Copal G + V cement (2 g vancomycin, 0.5 g gentamicin per 43 g) was cast into standardized rectangular blocks according to DIN ISO 5833. A reference group without surface structuring and three groups with progressively increasing surface area and depth were analyzed. After polymerization, specimens were incubated in phosphate-buffered saline at 37 °C. Antibiotic release was measured at defined intervals over six weeks using chemiluminescence immunoassay (CLIA). Results: Surface structuring resulted in a clear increase in cumulative antibiotic release, particularly for vancomycin, with a consistent relationship between surface enlargement and total elution. The greatest surface structuring led to the highest release levels. Gentamicin showed a similar but less pronounced response, with a notable increase only at the highest degree of surface enlargement. The initial burst release contributed substantially to overall elution, while later-phase release differences between groups were less marked. Conclusion: Surface modification of PMMA cement influenced antibiotic elution in this in vitro experimental model, with increased surface depth resulting in enhanced vancomycin release. Gentamicin elution was less affected by surface geometry and showed significant improvement only with the greatest surface enlargement. These findings indicate that structured cement surfaces may influence local antibiotic release characteristics under controlled laboratory conditions. However, the clinical relevance of these surface modifications remains to be determined, as this study was limited to cement blocks incubated in phosphate-buffered saline and did not include a spacer, infection, or in vivo model. Further experimental and in vivo investigations are required to assess whether surface structuring can improve antibiotic delivery in clinically relevant settings.
- Open Access
- 5 June 2026
- Published by Wiley in Orthopaedic Surgery
- Vol. 18 (7) , 1398-1405
Long‐Term Results of Anatomic Stemless Shoulder Prosthesis in Patients With Primary Osteoarthritis
Objectives: Shaft‐anchored prostheses have long been the gold standard in shoulder arthroplasty, but there is a growing trend toward bone‐preserving, stemless designs. Despite promising short‐ and midterm results, long‐term data remain limited. This study aims to report the long‐term outcomes of a stemless anatomic shoulder prosthesis in patients with primary osteoarthritis and seeks to answer the question of whether it is comparable to other prostheses. Methods: This retrospective single‐center study included 27 shoulders in 24 patients (mean age 75 ± 8.3 years), who were operated from 2009 to 2011. Outcomes assessed were Constant‐Murley score, range of motion, patient satisfaction, revision rate, and radiological findings. Mean follow‐up was 142 ± 12.2 months. Twenty‐one shoulders underwent total shoulder arthroplasty; six hemiarthroplasty. For the analysis of continuous variables, the Wilcoxon test was used following normality testing. Dichotomous variables were evaluated using the chi 2 test, with a significance level set at p < 0.05. Results: The Constant‐Murley score improved significantly from 23.1 ± 9.4 (27.5% age‐adjusted) preoperatively to 58.8 ± 18.6 (72.3% age‐adjusted) postoperatively ( p < 0.001). Range of motion increased in flexion (89.5°–137.2°), abduction (70.9°–117.2°), and external rotation (10°–36.8°), all statistically significant. Overall, 85% of patients were (very) satisfied. Four revisions were performed: two with conversion to alternative treatment, two within the same system due to loosening and infection. Ten‐ and 12‐year survival rates were 89% and 85%, respectively. A 30% risk of loosening was observed (per Molé), though no glenoid loosening occurred; humeral loosening was seen in one case. Conclusion: The clinical, functional, and radiological outcomes of the investigated stemless shoulder arthroplasty system remain satisfactory even in long‐term follow‐up. High patient satisfaction was observed. The data, which are unique in terms of the length of follow‐up, are comparable to those of other stemless anatomic shoulder arthroplasty designs.
- 5 June 2026
- Published by Wiley in Orthopaedic Surgery
- Vol. 18 (7) , 1398-1405
Open AccessLong‐Term Results of Anatomic Stemless Shoulder Prosthesis in Patients With Primary Osteoarthritis
Objectives: Shaft‐anchored prostheses have long been the gold standard in shoulder arthroplasty, but there is a growing trend toward bone‐preserving, stemless designs. Despite promising short‐ and midterm results, long‐term data remain limited. This study aims to report the long‐term outcomes of a stemless anatomic shoulder prosthesis in patients with primary osteoarthritis and seeks to answer the question of whether it is comparable to other prostheses. Methods: This retrospective single‐center study included 27 shoulders in 24 patients (mean age 75 ± 8.3 years), who were operated from 2009 to 2011. Outcomes assessed were Constant‐Murley score, range of motion, patient satisfaction, revision rate, and radiological findings. Mean follow‐up was 142 ± 12.2 months. Twenty‐one shoulders underwent total shoulder arthroplasty; six hemiarthroplasty. For the analysis of continuous variables, the Wilcoxon test was used following normality testing. Dichotomous variables were evaluated using the chi 2 test, with a significance level set at p < 0.05. Results: The Constant‐Murley score improved significantly from 23.1 ± 9.4 (27.5% age‐adjusted) preoperatively to 58.8 ± 18.6 (72.3% age‐adjusted) postoperatively ( p < 0.001). Range of motion increased in flexion (89.5°–137.2°), abduction (70.9°–117.2°), and external rotation (10°–36.8°), all statistically significant. Overall, 85% of patients were (very) satisfied. Four revisions were performed: two with conversion to alternative treatment, two within the same system due to loosening and infection. Ten‐ and 12‐year survival rates were 89% and 85%, respectively. A 30% risk of loosening was observed (per Molé), though no glenoid loosening occurred; humeral loosening was seen in one case. Conclusion: The clinical, functional, and radiological outcomes of the investigated stemless shoulder arthroplasty system remain satisfactory even in long‐term follow‐up. High patient satisfaction was observed. The data, which are unique in terms of the length of follow‐up, are comparable to those of other stemless anatomic shoulder arthroplasty designs.
- Open Access
- 19 November 2025
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 20 (1) , 1014
The effect of pulsatile lavage on antibiotic elution from bone cements in two-stage revision for periprosthetic joint infection
Purpose: Periprosthetic joint infection (PJI) is a major complication after total joint replacement, often requiring a two-stage revision with the use of antibiotic-loaded bone cement (ALBC) spacers for local antibiotic therapy. While factors such as cement composition and antibiotic type influence drug release, the impact of pulsatile lavage on antibiotic elution remains unclear. This study investigates the effect of pulsatile saline lavage on the release kinetics of gentamicin and vancomycin from different ALBCs over six weeks. Methods: Three commercially available PMMA bone cements A, B and C were prepared with identical antibiotic concentrations (0.5 g gentamicin, 2 g vancomycin). Rectangular cement blocks were manufactured according to ISO standards. Group A1/B1/C1 (non-lavage) was placed into a buffer solution without further processing. Group A2/B2/C2 (lavage) was treated with a defined amount of saline solution using high-pressure pulsatile saline lavage before being placed into the buffer solution. Antibiotic release was analyzed at ten predefined time points (T) over six weeks (5 h, 1 d, 2 d, 4 d, 1/2/3/4/5/6 weeks). All samples were stored in an incubator at 36 °C. Results: Statistically significant differences in the release kinetics of both gentamicin and vancomycin were observed for bone cement A and B after processing with saline lavage. Gentamicin release differed significantly between A1/A2 at T2 and T7–T10, and between B1/B2 at T1, T7, and T10; no significant differences were found between C1/C2. Cumulatively, only B1 vs. B2 showed a significant difference in gentamicin release ( p = 0.033). Vancomycin release differed significantly between A1/A2 at T1 and T5–T9, and between B1/B2 at T6; again, no significant differences were seen in C1/C2. Cumulative vancomycin release was significantly reduced in B2 compared to B1 ( p < 0.001). In four of six cements, vancomycin release declined by over 85% from T1 (5 h) to T3 (48 h). Conclusion: Pulsatile high-pressure lavage is an essential part of revision surgery due to its mechanical cleansing effects. However, this study indicates that its impact on antibiotic release from loaded bone cement is minimal. While variations exist depending on cement type, lavage does not seem to substantially alter the elution profile or expected antimicrobial efficacy.
- 19 November 2025
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 20 (1) , 1014
Open AccessThe effect of pulsatile lavage on antibiotic elution from bone cements in two-stage revision for periprosthetic joint infection
Purpose: Periprosthetic joint infection (PJI) is a major complication after total joint replacement, often requiring a two-stage revision with the use of antibiotic-loaded bone cement (ALBC) spacers for local antibiotic therapy. While factors such as cement composition and antibiotic type influence drug release, the impact of pulsatile lavage on antibiotic elution remains unclear. This study investigates the effect of pulsatile saline lavage on the release kinetics of gentamicin and vancomycin from different ALBCs over six weeks. Methods: Three commercially available PMMA bone cements A, B and C were prepared with identical antibiotic concentrations (0.5 g gentamicin, 2 g vancomycin). Rectangular cement blocks were manufactured according to ISO standards. Group A1/B1/C1 (non-lavage) was placed into a buffer solution without further processing. Group A2/B2/C2 (lavage) was treated with a defined amount of saline solution using high-pressure pulsatile saline lavage before being placed into the buffer solution. Antibiotic release was analyzed at ten predefined time points (T) over six weeks (5 h, 1 d, 2 d, 4 d, 1/2/3/4/5/6 weeks). All samples were stored in an incubator at 36 °C. Results: Statistically significant differences in the release kinetics of both gentamicin and vancomycin were observed for bone cement A and B after processing with saline lavage. Gentamicin release differed significantly between A1/A2 at T2 and T7–T10, and between B1/B2 at T1, T7, and T10; no significant differences were found between C1/C2. Cumulatively, only B1 vs. B2 showed a significant difference in gentamicin release ( p = 0.033). Vancomycin release differed significantly between A1/A2 at T1 and T5–T9, and between B1/B2 at T6; again, no significant differences were seen in C1/C2. Cumulative vancomycin release was significantly reduced in B2 compared to B1 ( p < 0.001). In four of six cements, vancomycin release declined by over 85% from T1 (5 h) to T3 (48 h). Conclusion: Pulsatile high-pressure lavage is an essential part of revision surgery due to its mechanical cleansing effects. However, this study indicates that its impact on antibiotic release from loaded bone cement is minimal. While variations exist depending on cement type, lavage does not seem to substantially alter the elution profile or expected antimicrobial efficacy.
- Open Access
- 18 August 2025
- Published by Springer Nature in International Orthopaedics
- Vol. 49 (10) , 2539-2547
Long-term results of cementless humeral head resurfacing for humeral head osteonecrosis – a monocentric longitudinal observational study
Purpose: Humeral head osteonecrosis (HHN) is a joint-destructive condition, for which cementless humeral head resurfacing (CHHR) offers a bone-preserving treatment option. The aim of this study was to report long-term outcomes and implant survival of CHHR in patients with HHN. Methods: Patients with humeral head osteonecrosis treated with cementless humeral head resurfacing (CHHR) between 2004 and 2007 were included. Implant survival was assessed according to Kaplan-Meier analysis. Clinical evaluation included Constant-Murley-Score (CMS), Simple Shoulder Test (SST), Subjective Shoulder Value (SSV) and patient centered outcomes regarding satisfaction and quality of life. Radiographs were evaluated for glenoid erosion, Walch glenoid types as well as signs of implant loosening. Statistical comparison was performed using students t-tests with a significance level set to p < 0.05. Results: Seventeen shoulders were retrospectively included in the implant survival analysis. Two patients underwent revision surgery. five patients died with the implant and were therefore censored. Cumulative survival rate was 100% after ten years and 93.3% after 15 years. Seven shoulders were available for clinical and radiological evaluation at a mean follow-up of 19 years (range 17–22 years). Age- and sex-adjusted CMS improved from preoperative to the latest follow-up (44.4% vs. 82.9%; p < 0.01). No glenoid erosion of higher degree (Sperling grade > 2) and no signs of implant loosening were observed. All patients had Walch type A glenoids preoperatively. Conclusion: In this small cohort with long-term follow-up of 17–22 years, CHHR showed promising durability and functional outcomes in carefully selected patients. Level of evidence: Level IV Case series with no comparison group.
- 18 August 2025
- Published by Springer Nature in International Orthopaedics
- Vol. 49 (10) , 2539-2547
Open AccessLong-term results of cementless humeral head resurfacing for humeral head osteonecrosis – a monocentric longitudinal observational study
Purpose: Humeral head osteonecrosis (HHN) is a joint-destructive condition, for which cementless humeral head resurfacing (CHHR) offers a bone-preserving treatment option. The aim of this study was to report long-term outcomes and implant survival of CHHR in patients with HHN. Methods: Patients with humeral head osteonecrosis treated with cementless humeral head resurfacing (CHHR) between 2004 and 2007 were included. Implant survival was assessed according to Kaplan-Meier analysis. Clinical evaluation included Constant-Murley-Score (CMS), Simple Shoulder Test (SST), Subjective Shoulder Value (SSV) and patient centered outcomes regarding satisfaction and quality of life. Radiographs were evaluated for glenoid erosion, Walch glenoid types as well as signs of implant loosening. Statistical comparison was performed using students t-tests with a significance level set to p < 0.05. Results: Seventeen shoulders were retrospectively included in the implant survival analysis. Two patients underwent revision surgery. five patients died with the implant and were therefore censored. Cumulative survival rate was 100% after ten years and 93.3% after 15 years. Seven shoulders were available for clinical and radiological evaluation at a mean follow-up of 19 years (range 17–22 years). Age- and sex-adjusted CMS improved from preoperative to the latest follow-up (44.4% vs. 82.9%; p < 0.01). No glenoid erosion of higher degree (Sperling grade > 2) and no signs of implant loosening were observed. All patients had Walch type A glenoids preoperatively. Conclusion: In this small cohort with long-term follow-up of 17–22 years, CHHR showed promising durability and functional outcomes in carefully selected patients. Level of evidence: Level IV Case series with no comparison group.
- Open Access
- 26 May 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (9) , 3324-3332
Cemented mobile‐bearing medial unicompartmental knee arthroplasty provides long‐term implant survival and sustained functional performance in young and active patients aged 60 or below
Purpose: To evaluate long‐term outcomes of cemented, mobile‐bearing medial unicompartmental knee arthroplasty (UKA) in patients aged 60 or younger, focusing on implant survival, functional results, patient‐reported outcome measures (PROMs), and radiographic findings over >10 years.Methods: This retrospective single‐centre study included 119 knees (102 patients). Implant survival was evaluated using Kaplan–Meier analysis. PROMs included the Oxford Knee Score (OKS), American Knee Society Score (AKSS), UCLA Activity Score and Visual Analogue Scale (VAS). Assessments were performed preoperatively, at mid‐term (2–10 years), and at long‐term follow‐up (>10 years). OKS and AKSS were analysed in relation to Patient Acceptable Symptom State (PASS) thresholds. Radiographs were graded using the Kellgren–Lawrence classification to evaluate lateral osteoarthritis (LOA) progression.Results: The implant survival rate was 86.7% (95% CI: 78.5–91.9%) at 15 years, and 81.7% (95% CI: 71.4%–88.5%) at 17.5 years. Revision surgery was required in 18 knees (mean time to revision: 8.7 years), primarily due to progression of LOA. All PROMs improved significantly from baseline to the final follow‐up (mean: 16 years; p < 0.0001). Although minor functional declines occurred between mid‐ and long‐term follow‐ups, these were not statistically significant (p > 0.05), except for functional AKSS. At the final assessment, 96% of patients exceeded the PASS threshold for OKS, 84% for AKSS objective, and 80% for AKSS functional scores. Radiographic LOA progression was frequent but did not significantly impair functional outcomes.Conclusions: Cemented mobile‐bearing medial UKA in patients aged ≤60 years demonstrated high long‐term implant survival and sustained functional benefit. Even in the presence of radiographic LOA progression, clinical outcomes remained excellent. UKA represents a durable and effective treatment for younger patients with isolated medial compartment osteoarthritis.Level of Evidence: Level IV.
- 26 May 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (9) , 3324-3332
Open AccessCemented mobile‐bearing medial unicompartmental knee arthroplasty provides long‐term implant survival and sustained functional performance in young and active patients aged 60 or below
Purpose: To evaluate long‐term outcomes of cemented, mobile‐bearing medial unicompartmental knee arthroplasty (UKA) in patients aged 60 or younger, focusing on implant survival, functional results, patient‐reported outcome measures (PROMs), and radiographic findings over >10 years.Methods: This retrospective single‐centre study included 119 knees (102 patients). Implant survival was evaluated using Kaplan–Meier analysis. PROMs included the Oxford Knee Score (OKS), American Knee Society Score (AKSS), UCLA Activity Score and Visual Analogue Scale (VAS). Assessments were performed preoperatively, at mid‐term (2–10 years), and at long‐term follow‐up (>10 years). OKS and AKSS were analysed in relation to Patient Acceptable Symptom State (PASS) thresholds. Radiographs were graded using the Kellgren–Lawrence classification to evaluate lateral osteoarthritis (LOA) progression.Results: The implant survival rate was 86.7% (95% CI: 78.5–91.9%) at 15 years, and 81.7% (95% CI: 71.4%–88.5%) at 17.5 years. Revision surgery was required in 18 knees (mean time to revision: 8.7 years), primarily due to progression of LOA. All PROMs improved significantly from baseline to the final follow‐up (mean: 16 years; p < 0.0001). Although minor functional declines occurred between mid‐ and long‐term follow‐ups, these were not statistically significant (p > 0.05), except for functional AKSS. At the final assessment, 96% of patients exceeded the PASS threshold for OKS, 84% for AKSS objective, and 80% for AKSS functional scores. Radiographic LOA progression was frequent but did not significantly impair functional outcomes.Conclusions: Cemented mobile‐bearing medial UKA in patients aged ≤60 years demonstrated high long‐term implant survival and sustained functional benefit. Even in the presence of radiographic LOA progression, clinical outcomes remained excellent. UKA represents a durable and effective treatment for younger patients with isolated medial compartment osteoarthritis.Level of Evidence: Level IV.
- Open Access
- 30 October 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (21) , 6846
Reply to Alt et al. Comment on “Lunz et al. Impact and Modification of the New PJI-TNM Classification for Periprosthetic Joint Infections. J. Clin. Med. 2023, 12, 1262”
We greatly appreciate the comments made by Alt et al.
- 30 October 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (21) , 6846
Open AccessReply to Alt et al. Comment on “Lunz et al. Impact and Modification of the New PJI-TNM Classification for Periprosthetic Joint Infections. J. Clin. Med. 2023, 12, 1262”
We greatly appreciate the comments made by Alt et al.
- Open Access
- 11 August 2023
- Published by Springer Nature in International Orthopaedics
- Vol. 47 (11) , 2655-2661
Enhanced antibiotic release from bone cement spacers utilizing dual antibiotic loading with elevated vancomycin concentrations in two-stage revision for periprosthetic joint infection
Purpose: Antibiotic loaded bone cement spacers provide high local antibiotic concentrations, preserve bone stock, and reduce soft tissue contractions. The objective of this in-vitro study was to compare antibiotic release from spacers, aiming to discover the most optimal preparation and identify modifiable factors that can further enhance antibiotic release. Methods: Six distinct spacer preparation were created using three different bone cements and manual incorporation of antibiotics. During a six-week period, the release of antibiotics from each spacer was measured individually at ten predetermined time points using a chemiluminescent immunoassay. Results: Manually adding 4 g of vancomycin to every 40 g of “Palacos R + G” yielded the most favorable release profile. Throughout all preparations, antibiotic release consistently and significantly decreased over the six-week period. When incorporating a higher concentration of vancomycin, a significantly higher cumulative release of vancomycin was observed, with varying effects on the release of gentamicin. The choice of bone cement had a significant impact on antibiotic release. Conclusion: To enhance antibiotic release from spacers, surgeons should manually incorporate high antibiotic concentrations into the most appropriate bone cement and keep the interim period as short as possible. Specifically, we suggest manual incorporation of 4 g of vancomycin to every 40 g of gentamicin premixed "Palacos R + G" to create bone cement spacers.
- 11 August 2023
- Published by Springer Nature in International Orthopaedics
- Vol. 47 (11) , 2655-2661
Open AccessEnhanced antibiotic release from bone cement spacers utilizing dual antibiotic loading with elevated vancomycin concentrations in two-stage revision for periprosthetic joint infection
Purpose: Antibiotic loaded bone cement spacers provide high local antibiotic concentrations, preserve bone stock, and reduce soft tissue contractions. The objective of this in-vitro study was to compare antibiotic release from spacers, aiming to discover the most optimal preparation and identify modifiable factors that can further enhance antibiotic release. Methods: Six distinct spacer preparation were created using three different bone cements and manual incorporation of antibiotics. During a six-week period, the release of antibiotics from each spacer was measured individually at ten predetermined time points using a chemiluminescent immunoassay. Results: Manually adding 4 g of vancomycin to every 40 g of “Palacos R + G” yielded the most favorable release profile. Throughout all preparations, antibiotic release consistently and significantly decreased over the six-week period. When incorporating a higher concentration of vancomycin, a significantly higher cumulative release of vancomycin was observed, with varying effects on the release of gentamicin. The choice of bone cement had a significant impact on antibiotic release. Conclusion: To enhance antibiotic release from spacers, surgeons should manually incorporate high antibiotic concentrations into the most appropriate bone cement and keep the interim period as short as possible. Specifically, we suggest manual incorporation of 4 g of vancomycin to every 40 g of gentamicin premixed "Palacos R + G" to create bone cement spacers.
- Open Access
- 5 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (4) , 1262
Impact and Modification of the New PJI-TNM Classification for Periprosthetic Joint Infections
The comprehensive “PJI-TNM classification” for the description of periprosthetic joint infections (PJI) was introduced in 2020. Its structure is based on the well-known oncological TNM classification to appreciate the complexity, severity, and diversity of PJIs. The main goal of this study is to implement the new PJI-TNM classification into the clinical setting to determine its therapeutic and prognostic value and suggest modifications to further improve the classification for clinical routine use. A retrospective cohort study was conducted at our institution between 2017 and 2020. A total of 80 consecutive patients treated with a two-stage revision for periprosthetic knee joint infection were included. We retrospectively assessed correlations between patients’ preoperative PJI-TNM classification and their therapy and outcome and identified several statistically significant correlations for both classifications, the original and our modified version. We have demonstrated that both classifications provide reliable predictions already at the time of diagnosis regarding the invasiveness of surgery (duration of surgery, blood and bone loss during surgery), likelihood of reimplantation, and patient mortality during the first 12 months after diagnosis. Orthopedic surgeons can use the classification system preoperatively as an objective and comprehensive tool for therapeutic decisions and patient information (informed consent). In the future, comparisons between different treatment options for truly similar preoperative baseline situations can be obtained for the first time. Clinicians and researchers should be familiar with the new PJI-TNM classification and start implementing it into their routine practice. Our adjusted and simplified version (“PJI-pTNM”) might be a more convenient alternative for the clinical setting.
- 5 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (4) , 1262
Open AccessImpact and Modification of the New PJI-TNM Classification for Periprosthetic Joint Infections
The comprehensive “PJI-TNM classification” for the description of periprosthetic joint infections (PJI) was introduced in 2020. Its structure is based on the well-known oncological TNM classification to appreciate the complexity, severity, and diversity of PJIs. The main goal of this study is to implement the new PJI-TNM classification into the clinical setting to determine its therapeutic and prognostic value and suggest modifications to further improve the classification for clinical routine use. A retrospective cohort study was conducted at our institution between 2017 and 2020. A total of 80 consecutive patients treated with a two-stage revision for periprosthetic knee joint infection were included. We retrospectively assessed correlations between patients’ preoperative PJI-TNM classification and their therapy and outcome and identified several statistically significant correlations for both classifications, the original and our modified version. We have demonstrated that both classifications provide reliable predictions already at the time of diagnosis regarding the invasiveness of surgery (duration of surgery, blood and bone loss during surgery), likelihood of reimplantation, and patient mortality during the first 12 months after diagnosis. Orthopedic surgeons can use the classification system preoperatively as an objective and comprehensive tool for therapeutic decisions and patient information (informed consent). In the future, comparisons between different treatment options for truly similar preoperative baseline situations can be obtained for the first time. Clinicians and researchers should be familiar with the new PJI-TNM classification and start implementing it into their routine practice. Our adjusted and simplified version (“PJI-pTNM”) might be a more convenient alternative for the clinical setting.
- Open Access
- 13 September 2022
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 49 (1) , 327-333
Pulsatile lavage systems and their potential to penetrate soft tissue
Background: In orthopedic and trauma surgery, pulsatile lavage systems are used to clean soft tissue. This may be necessary in septic surgeries or in case of contaminated wounds after trauma. Positive features such as reduction of bacterial contamination and removal of foreign particles are counterbalanced by negative aspects such as bacterial seeding in deeper tissue layers, damage to various tissues and even cases of air embolism. Purpose: The aim of this prospective experimental in vitro study was to compare impact pressure and flow rate in three different pulsatile lavage systems and to determine, whether these parameters alter their ability to reach deeper soft tissue layers. Methods: To test the penetration of soft tissue, the muscle tissue was flushed with contrast medium instead of saline fluid and afterwards scanned by computed tomography. Results: Impact pressure and flow rate showed significant differences between the different systems. There were no significant differences between the three devices in terms of total penetration volume, but there were significant differences in penetration depth. Conclusion: In this study, we found that higher impact pressure leads to deeper penetration and therefore bacteria are likely to be transferred to deeper tissue layers.
- 13 September 2022
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 49 (1) , 327-333
Open AccessPulsatile lavage systems and their potential to penetrate soft tissue
Background: In orthopedic and trauma surgery, pulsatile lavage systems are used to clean soft tissue. This may be necessary in septic surgeries or in case of contaminated wounds after trauma. Positive features such as reduction of bacterial contamination and removal of foreign particles are counterbalanced by negative aspects such as bacterial seeding in deeper tissue layers, damage to various tissues and even cases of air embolism. Purpose: The aim of this prospective experimental in vitro study was to compare impact pressure and flow rate in three different pulsatile lavage systems and to determine, whether these parameters alter their ability to reach deeper soft tissue layers. Methods: To test the penetration of soft tissue, the muscle tissue was flushed with contrast medium instead of saline fluid and afterwards scanned by computed tomography. Results: Impact pressure and flow rate showed significant differences between the different systems. There were no significant differences between the three devices in terms of total penetration volume, but there were significant differences in penetration depth. Conclusion: In this study, we found that higher impact pressure leads to deeper penetration and therefore bacteria are likely to be transferred to deeper tissue layers.
- Open Access
- 24 December 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (1) , 88
Pulsatile Lavage Systems with High Impact Pressure and High Flow Produce Cleaner Cancellous Bone Prior to Cementation in Cemented Arthroplasty
In cemented joint arthroplasty, state-of-the-art cementing techniques include high-pressure pulsatile saline lavage prior to cementation. Even with its outstanding importance in cementation, there are surprisingly few studies regarding the physical parameters that define pulsatile lavage systems. To investigate the parameters of impact pressure, flow rate, frequency and the cleaning effect in cancellous bone, we established a standardized laboratory model. Standardized fat-filled carbon foam specimens representing human cancellous bone were cleaned with three different high-pressure pulsatile lavage systems. Via CT scans before and after cleaning, the cleaning effect was evaluated. All systems showed a cleaning depth of at least 3.0 mm and therefore can be generally recommended to clean cancellous bone in cemented joint arthroplasty. When comparing the three lavage systems, the study showed significant differences regarding cleaning depths and volume, with one system being superior to its peer systems. Regarding the physical parameters, high impact pressure in combination with high flow rate and longer distance to the flushed object seems to be the best combination to improve the cleaning of cancellous bone and therefore increase the chances of a deeper cement penetration that is required in cemented joint arthroplasty. In summary, this study provides the first standardized comparison of different lavage systems and thus gives initial guidance on how to optimally prepare cancellous bone for cemented joint arthroplasty.
- 24 December 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (1) , 88
Open AccessPulsatile Lavage Systems with High Impact Pressure and High Flow Produce Cleaner Cancellous Bone Prior to Cementation in Cemented Arthroplasty
In cemented joint arthroplasty, state-of-the-art cementing techniques include high-pressure pulsatile saline lavage prior to cementation. Even with its outstanding importance in cementation, there are surprisingly few studies regarding the physical parameters that define pulsatile lavage systems. To investigate the parameters of impact pressure, flow rate, frequency and the cleaning effect in cancellous bone, we established a standardized laboratory model. Standardized fat-filled carbon foam specimens representing human cancellous bone were cleaned with three different high-pressure pulsatile lavage systems. Via CT scans before and after cleaning, the cleaning effect was evaluated. All systems showed a cleaning depth of at least 3.0 mm and therefore can be generally recommended to clean cancellous bone in cemented joint arthroplasty. When comparing the three lavage systems, the study showed significant differences regarding cleaning depths and volume, with one system being superior to its peer systems. Regarding the physical parameters, high impact pressure in combination with high flow rate and longer distance to the flushed object seems to be the best combination to improve the cleaning of cancellous bone and therefore increase the chances of a deeper cement penetration that is required in cemented joint arthroplasty. In summary, this study provides the first standardized comparison of different lavage systems and thus gives initial guidance on how to optimally prepare cancellous bone for cemented joint arthroplasty.