Pulsatile lavage systems and their potential to penetrate soft tissue
Open Access
- 13 September 2022
- journal article
- research article
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 49 (1) , 327-333
Abstract
Background: In orthopedic and trauma surgery, pulsatile lavage systems are used to clean soft tissue. This may be necessary in septic surgeries or in case of contaminated wounds after trauma. Positive features such as reduction of bacterial contamination and removal of foreign particles are counterbalanced by negative aspects such as bacterial seeding in deeper tissue layers, damage to various tissues and even cases of air embolism. Purpose: The aim of this prospective experimental in vitro study was to compare impact pressure and flow rate in three different pulsatile lavage systems and to determine, whether these parameters alter their ability to reach deeper soft tissue layers. Methods: To test the penetration of soft tissue, the muscle tissue was flushed with contrast medium instead of saline fluid and afterwards scanned by computed tomography. Results: Impact pressure and flow rate showed significant differences between the different systems. There were no significant differences between the three devices in terms of total penetration volume, but there were significant differences in penetration depth. Conclusion: In this study, we found that higher impact pressure leads to deeper penetration and therefore bacteria are likely to be transferred to deeper tissue layers.Keywords
Funding Information
- Heraeus Medical, Wehrheim, Germany
- Universitätsklinikum Heidelberg
This publication has 32 references indexed in Scilit:
- Tibial cleaning method for cemented total knee arthroplasty: An experimental studyIndian Journal of Orthopaedics, 2013
- Intramuscular Air as a Complication of Pulse-Lavage IrrigationJournal of Bone and Joint Surgery, 2009
- Pulsed lavage reduces the incidence of radiolucent lines under the tibial tray of Oxford unicompartmental knee arthroplastyInternational Orthopaedics, 2009
- Comparison of Irrigation Solutions and Devices in a Contaminated Musculoskeletal Wound Survival ModelJournal of Bone and Joint Surgery, 2009
- An experimental comparison of different devices for pulsatile high-pressure lavage and their relevance to cement intrusion into cancellous boneArchives of orthopaedic and trauma surgery, 2007
- User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliabilityNeuroImage, 2006
- Intraoperative air embolism with pulse irrigation deviceJournal of Clinical Anesthesia, 1996
- Air Embolism during Pulsed Saline Irrigation of an Open Pelvic Fracture1989
- Evaluation of Wound Irrigation by Pulsatile Jet and Conventional MethodsAnnals of Surgery, 1978
- Effectiveness of pulsating water jet lavage in treatment of contaminated crushed woundsThe American Journal of Surgery, 1972