Andrew Renshaw
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrew Renshaw has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Alec Habig
University of Minnesota Duluth
5 shared publications - Kate Scholberg
Duke University
5 shared publications - Andrey Sheshukov
Affiliated with an Institute or an International Laboratory Participating within the DUNE Collaboration
4 shared publications - Christopher Tunnell
Department of Physics and Astronomy, Rice University, Houston, Texas 77005, USA
4 shared publications - Jelena Maricic
University of Hawaii
4 shared publications - Marco Pallavicini
Istituto Nazionale di Fisica Nucleare Sezione di Genova
4 shared publications
Latest Publications
- Open Access
- 21 September 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (9) , 1089
Construction and characterisation of the DarkSide-20k veto silicon photo-multiplier tiles
Silicon photo-multipliers (SiPMs) are state-of-the-art sensors capable of detecting a single photoelectron under cryogenic conditions, with potentially lower radioactivity than widely used photomultiplier tubes. The DarkSide-20k experiment, designed to perform direct dark matter searches using liquid argon as the target material, employs SiPM technology to detect interactions in the active detector volumes, including the central dual-phase Time Projection Chamber and the Inner and Outer Veto volumes. The vetoes are designed to discriminate against radiogenic neutron and cosmic muon backgrounds associated with the dark matter search. This paper describes the completed production and test protocols for the “Veto Tiles” (called vTiles , arrays of 24 SiPMs integrated on a printed circuit board providing the power distribution and signal amplification); 16 vTiles are grouped into “Veto Photo-Detector Units” to instrument the Inner Veto volume. Each vTile underwent detailed testing at room and cryogenic temperatures, confirming stable operation, high signal-to-noise ratio, and low radioactive contamination, demonstrating the robustness of the proposed design for cryogenic conditions. The final production yield exceeded 87%, surpassing the 80% requirement and corresponding to 1920 Veto Tiles to populate 120 Veto Photo-Detector Units, plus an additional 6% as spares.
- 21 September 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (9) , 1089
Open AccessConstruction and characterisation of the DarkSide-20k veto silicon photo-multiplier tiles
Silicon photo-multipliers (SiPMs) are state-of-the-art sensors capable of detecting a single photoelectron under cryogenic conditions, with potentially lower radioactivity than widely used photomultiplier tubes. The DarkSide-20k experiment, designed to perform direct dark matter searches using liquid argon as the target material, employs SiPM technology to detect interactions in the active detector volumes, including the central dual-phase Time Projection Chamber and the Inner and Outer Veto volumes. The vetoes are designed to discriminate against radiogenic neutron and cosmic muon backgrounds associated with the dark matter search. This paper describes the completed production and test protocols for the “Veto Tiles” (called vTiles , arrays of 24 SiPMs integrated on a printed circuit board providing the power distribution and signal amplification); 16 vTiles are grouped into “Veto Photo-Detector Units” to instrument the Inner Veto volume. Each vTile underwent detailed testing at room and cryogenic temperatures, confirming stable operation, high signal-to-noise ratio, and low radioactive contamination, demonstrating the robustness of the proposed design for cryogenic conditions. The final production yield exceeded 87%, surpassing the 80% requirement and corresponding to 1920 Veto Tiles to populate 120 Veto Photo-Detector Units, plus an additional 6% as spares.
- Open Access
- 12 May 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (9)
Supernova pointing capabilities of DUNE
The determination of the direction of a stellar core collapse via its neutrino emission is crucial for the identification of the progenitor for a multimessenger follow-up. A highly effective method of reconstructing supernova directions within the Deep Underground Neutrino Experiment (DUNE) is introduced. The supernova neutrino pointing resolution is studied by simulating and reconstructing electron-neutrino charged-current absorption on Ar 40 and elastic scattering of neutrinos on electrons. Procedures to reconstruct individual interactions, including a newly developed technique called “brems flipping,” as well as the burst direction from an ensemble of interactions are described. Performance of the burst direction reconstruction is evaluated for supernovae happening at a distance of 10 kpc for a specific supernova burst flux model. The pointing resolution is found to be 3.4 degrees at 68% coverage for a perfect interaction-channel classification and a fiducial mass of 40 kton, and 6.6 degrees for a 10 kton fiducial mass respectively. Assuming a 4% rate of charged-current interactions being misidentified as elastic scattering, DUNE’s burst pointing resolution is found to be 4.3 degrees (8.7 degrees) at 68% coverage. Published by the American Physical Society 2025
- 12 May 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (9)
Open AccessSupernova pointing capabilities of DUNE
The determination of the direction of a stellar core collapse via its neutrino emission is crucial for the identification of the progenitor for a multimessenger follow-up. A highly effective method of reconstructing supernova directions within the Deep Underground Neutrino Experiment (DUNE) is introduced. The supernova neutrino pointing resolution is studied by simulating and reconstructing electron-neutrino charged-current absorption on Ar 40 and elastic scattering of neutrinos on electrons. Procedures to reconstruct individual interactions, including a newly developed technique called “brems flipping,” as well as the burst direction from an ensemble of interactions are described. Performance of the burst direction reconstruction is evaluated for supernovae happening at a distance of 10 kpc for a specific supernova burst flux model. The pointing resolution is found to be 3.4 degrees at 68% coverage for a perfect interaction-channel classification and a fiducial mass of 40 kton, and 6.6 degrees for a 10 kton fiducial mass respectively. Assuming a 4% rate of charged-current interactions being misidentified as elastic scattering, DUNE’s burst pointing resolution is found to be 4.3 degrees (8.7 degrees) at 68% coverage. Published by the American Physical Society 2025
- 12 March 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (6) , 065015
3Dπ: three-dimensional positron imaging, a novel total-body PET scanner using xenon-doped liquid argon scintillator
Objective. This paper introduces a novel PET imaging methodology called 3-dimensional positron imaging (3Dπ), which integrates total-body coverage, time-of-flight (TOF) technology, ultra-low dose imaging capabilities, and ultra-fast readout electronics inspired by emerging technology from the DarkSide collaboration. Approach. The study evaluates the performance of 3Dπ using Monte Carlo simulations based on NEMA NU 2-2018 protocols. The methodology employs a homogenous, monolithic scintillator composed of liquid argon (LAr) doped with xenon (Xe) with silicon photomultipliers (SiPMs) operating at cryogenic temperatures. Main results. Substantial improvements in system performance are observed, with the 3Dπ system achieving a noise equivalent count rate of 3.2 Mcps at 17.3 kBq ml−1, continuing to increase up to 4.3 Mcps at 40 kBq ml−1. Spatial resolution measurements show an average FWHM of 2.7 mm across both axial positions. The system exhibits superior sensitivity, with values reaching 373 kcps MBq−1 with a line source at the center of the field of view. Additionally, 3Dπ achieves a TOF resolution of 151 ps at 5.3 kBq ml−1, highlighting its potential to produce high-quality images with reduced noise levels. Significance. The study underscores the potential of 3Dπ in improving PET imaging performance, offering the potential for shorter scan times and reduced radiation exposure for patients. The Xe-doped LAr offers advantages such as fast scintillation, enhanced light yield, and cost-effectiveness. Future research will focus on optimizing system geometry and further refining reconstruction algorithms to exploit the strengths of 3Dπ for clinical applications.
- 12 March 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (6) , 065015
3Dπ: three-dimensional positron imaging, a novel total-body PET scanner using xenon-doped liquid argon scintillator
Objective. This paper introduces a novel PET imaging methodology called 3-dimensional positron imaging (3Dπ), which integrates total-body coverage, time-of-flight (TOF) technology, ultra-low dose imaging capabilities, and ultra-fast readout electronics inspired by emerging technology from the DarkSide collaboration. Approach. The study evaluates the performance of 3Dπ using Monte Carlo simulations based on NEMA NU 2-2018 protocols. The methodology employs a homogenous, monolithic scintillator composed of liquid argon (LAr) doped with xenon (Xe) with silicon photomultipliers (SiPMs) operating at cryogenic temperatures. Main results. Substantial improvements in system performance are observed, with the 3Dπ system achieving a noise equivalent count rate of 3.2 Mcps at 17.3 kBq ml−1, continuing to increase up to 4.3 Mcps at 40 kBq ml−1. Spatial resolution measurements show an average FWHM of 2.7 mm across both axial positions. The system exhibits superior sensitivity, with values reaching 373 kcps MBq−1 with a line source at the center of the field of view. Additionally, 3Dπ achieves a TOF resolution of 151 ps at 5.3 kBq ml−1, highlighting its potential to produce high-quality images with reduced noise levels. Significance. The study underscores the potential of 3Dπ in improving PET imaging performance, offering the potential for shorter scan times and reduced radiation exposure for patients. The Xe-doped LAr offers advantages such as fast scintillation, enhanced light yield, and cost-effectiveness. Future research will focus on optimizing system geometry and further refining reconstruction algorithms to exploit the strengths of 3Dπ for clinical applications.
- Open Access
- 14 November 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 110 (9)
First measurement of the total inelastic cross section of positively charged kaons on argon at energies between 5.0 and 7.5 GeV
ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton liquid argon time projection chamber that operated in a hadron test beam at the CERN Neutrino Platform in 2018. We present a measurement of the total inelastic cross section of charged kaons on argon as a function of kaon energy using 6 and 7 GeV / c beam momentum settings. The flux-weighted average of the extracted inelastic cross section at each beam momentum setting was measured to be 380 ± 26 mbarns for the 6 GeV / c setting and 379 ± 35 mbarns for the 7 GeV / c setting. Published by the American Physical Society 2024
- 14 November 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 110 (9)
Open AccessFirst measurement of the total inelastic cross section of positively charged kaons on argon at energies between 5.0 and 7.5 GeV
ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton liquid argon time projection chamber that operated in a hadron test beam at the CERN Neutrino Platform in 2018. We present a measurement of the total inelastic cross section of charged kaons on argon as a function of kaon energy using 6 and 7 GeV / c beam momentum settings. The flux-weighted average of the extracted inelastic cross section at each beam momentum setting was measured to be 380 ± 26 mbarns for the 6 GeV / c setting and 379 ± 35 mbarns for the 7 GeV / c setting. Published by the American Physical Society 2024
- 31 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (3) , 245-253
On-Chip Fast Signal Generation and Low-Power SAR ADC for SiPM Readout
This paper presents an on-chip fast signal generator and a successive-approximation-register (SAR) analog-to-digital data converter (ADC) for silicon photomultiplier (SiPM) readout applications. The high-pass filter (HPF)-based fast-signal generator sharpens the rising edge of the standard SiPM output signal reducing time jitter due to the dark counts of the detector. It is implemented by leveraging the equivalent resistance of the current mirror transistor and the AC-coupling capacitor between the current mirror and the current discriminator to avoid hardware and power consumption overhead. Compared with off-chip solutions, the on-chip approach eliminates the packaging pins and high-speed buffers needed for carrying the fast signals reducing packaging complexity and power consumption of the readout system. The energy quantizer utilizes the SiPM charge integrator as the ADC track-and-hold (T/H) circuit to improve the front-end power efficiency. The fast signal generator and the SAR ADC are implemented in a current-mode application-specific integrated circuit (ASIC) designed in a 0.18 μm CMOS technology. Measurement results show that the on-chip fast signal generator is effective in improving the timing performance of the readout system. The timing resolutions are measured using SensL’s 3×3 mm 2 SiPM device with a terminal capacitance of 850 pF using an ultrashort laser pulser. Measurement results show that the fast signal generator improves the timing resolution by 23.4% compared with timing measurement using the standard output signal when the output charge is 300 pC. The ASIC achieved a measured ADC signal-to-noise-distortion ratio (SNDR) of 53.08 dB and a spurious-free dynamic range (SFDR) of 62.74 dB at 1 MS/s and a maximum front-end gain non-linearity of 3.3% over 20-800 pC input charge range while dissipating 4.1 mW of power from a 1.8 V supply.
- 31 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (3) , 245-253
On-Chip Fast Signal Generation and Low-Power SAR ADC for SiPM Readout
This paper presents an on-chip fast signal generator and a successive-approximation-register (SAR) analog-to-digital data converter (ADC) for silicon photomultiplier (SiPM) readout applications. The high-pass filter (HPF)-based fast-signal generator sharpens the rising edge of the standard SiPM output signal reducing time jitter due to the dark counts of the detector. It is implemented by leveraging the equivalent resistance of the current mirror transistor and the AC-coupling capacitor between the current mirror and the current discriminator to avoid hardware and power consumption overhead. Compared with off-chip solutions, the on-chip approach eliminates the packaging pins and high-speed buffers needed for carrying the fast signals reducing packaging complexity and power consumption of the readout system. The energy quantizer utilizes the SiPM charge integrator as the ADC track-and-hold (T/H) circuit to improve the front-end power efficiency. The fast signal generator and the SAR ADC are implemented in a current-mode application-specific integrated circuit (ASIC) designed in a 0.18 μm CMOS technology. Measurement results show that the on-chip fast signal generator is effective in improving the timing performance of the readout system. The timing resolutions are measured using SensL’s 3×3 mm 2 SiPM device with a terminal capacitance of 850 pF using an ultrashort laser pulser. Measurement results show that the fast signal generator improves the timing resolution by 23.4% compared with timing measurement using the standard output signal when the output charge is 300 pC. The ASIC achieved a measured ADC signal-to-noise-distortion ratio (SNDR) of 53.08 dB and a spurious-free dynamic range (SFDR) of 62.74 dB at 1 MS/s and a maximum front-end gain non-linearity of 3.3% over 20-800 pC input charge range while dissipating 4.1 mW of power from a 1.8 V supply.
- Open Access
- 31 January 2022
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 925 (2) , 107
SNEWPY: A Data Pipeline from Supernova Simulations to Neutrino Signals
Current neutrino detectors will observe hundreds to thousands of neutrinos from Galactic supernovae, and future detectors will increase this yield by an order of magnitude or more. With such a data set comes the potential for a huge increase in our understanding of the explosions of massive stars, nuclear physics under extreme conditions, and the properties of the neutrino. However, there is currently a large gap between supernova simulations and the corresponding signals in neutrino detectors, which will make any comparison between theory and observation very difficult. SNEWPY is an open-source software package that bridges this gap. The SNEWPY code can interface with supernova simulation data to generate from the model either a time series of neutrino spectral fluences at Earth, or the total time-integrated spectral fluence. Data from several hundred simulations of core-collapse, thermonuclear, and pair-instability supernovae is included in the package. This output may then be used by an event generator such as sntools or an event rate calculator such as the SuperNova Observatories with General Long Baseline Experiment Simulator (SNOwGLoBES). Additional routines in the SNEWPY package automate the processing of the generated data through the SNOwGLoBES software and collate its output into the observable channels of each detector. In this paper we describe the contents of the package, the physics behind SNEWPY, the organization of the code, and provide examples of how to make use of its capabilities.
- 31 January 2022
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 925 (2) , 107
Open AccessSNEWPY: A Data Pipeline from Supernova Simulations to Neutrino Signals
Current neutrino detectors will observe hundreds to thousands of neutrinos from Galactic supernovae, and future detectors will increase this yield by an order of magnitude or more. With such a data set comes the potential for a huge increase in our understanding of the explosions of massive stars, nuclear physics under extreme conditions, and the properties of the neutrino. However, there is currently a large gap between supernova simulations and the corresponding signals in neutrino detectors, which will make any comparison between theory and observation very difficult. SNEWPY is an open-source software package that bridges this gap. The SNEWPY code can interface with supernova simulation data to generate from the model either a time series of neutrino spectral fluences at Earth, or the total time-integrated spectral fluence. Data from several hundred simulations of core-collapse, thermonuclear, and pair-instability supernovae is included in the package. This output may then be used by an event generator such as sntools or an event rate calculator such as the SuperNova Observatories with General Long Baseline Experiment Simulator (SNOwGLoBES). Additional routines in the SNEWPY package automate the processing of the generated data through the SNOwGLoBES software and collate its output into the observable channels of each detector. In this paper we describe the contents of the package, the physics behind SNEWPY, the organization of the code, and provide examples of how to make use of its capabilities.
- Open Access
- 27 November 2021
- Published by The Open Journal in Journal of Open Source Software
- Vol. 6 (67) , 3772
SNEWPY: A Data Pipeline from Supernova Simulations to Neutrino Signals
- 27 November 2021
- Published by The Open Journal in Journal of Open Source Software
- Vol. 6 (67) , 3772
Open AccessSNEWPY: A Data Pipeline from Supernova Simulations to Neutrino Signals
- 1 March 2021
- Published by AIP Publishing in Physics of Fluids
- Vol. 33 (3) , 037122
The novel Mechanical Ventilator Milano for the COVID-19 pandemic
This paper presents the Mechanical Ventilator Milano (MVM), a novel intensive therapy mechanical ventilator designed for rapid, large-scale, low-cost production for the COVID-19 pandemic. Free of moving mechanical parts and requiring only a source of compressed oxygen and medical air to operate, the MVM is designed to support the long-term invasive ventilation often required for COVID-19 patients and operates in pressure-regulated ventilation modes, which minimize the risk of furthering lung trauma. The MVM was extensively tested against ISO standards in the laboratory using a breathing simulator, with good agreement between input and measured breathing parameters and performing correctly in response to fault conditions and stability tests. The MVM has obtained Emergency Use Authorization by U.S. Food and Drug Administration (FDA) for use in healthcare settings during the COVID-19 pandemic and Health Canada Medical Device Authorization for Importation or Sale, under Interim Order for Use in Relation to COVID-19. Following these certifications, mass production is ongoing and distribution is under way in several countries. The MVM was designed, tested, prepared for certification, and mass produced in the space of a few months by a unique collaboration of respiratory healthcare professionals and experimental physicists, working with industrial partners, and is an excellent ventilator candidate for this pandemic anywhere in the world.
- 1 March 2021
- Published by AIP Publishing in Physics of Fluids
- Vol. 33 (3) , 037122
The novel Mechanical Ventilator Milano for the COVID-19 pandemic
This paper presents the Mechanical Ventilator Milano (MVM), a novel intensive therapy mechanical ventilator designed for rapid, large-scale, low-cost production for the COVID-19 pandemic. Free of moving mechanical parts and requiring only a source of compressed oxygen and medical air to operate, the MVM is designed to support the long-term invasive ventilation often required for COVID-19 patients and operates in pressure-regulated ventilation modes, which minimize the risk of furthering lung trauma. The MVM was extensively tested against ISO standards in the laboratory using a breathing simulator, with good agreement between input and measured breathing parameters and performing correctly in response to fault conditions and stability tests. The MVM has obtained Emergency Use Authorization by U.S. Food and Drug Administration (FDA) for use in healthcare settings during the COVID-19 pandemic and Health Canada Medical Device Authorization for Importation or Sale, under Interim Order for Use in Relation to COVID-19. Following these certifications, mass production is ongoing and distribution is under way in several countries. The MVM was designed, tested, prepared for certification, and mass produced in the space of a few months by a unique collaboration of respiratory healthcare professionals and experimental physicists, working with industrial partners, and is an excellent ventilator candidate for this pandemic anywhere in the world.
- 7 February 2020
- Published by Office of Scientific and Technical Information (OSTI)
Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume II: DUNE Physics
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume II of this TDR, DUNE Physics, describes the array of identified scientific opportunities and key goals. Crucially, we also report our best current understanding of the capability of DUNE to realize these goals, along with the detailed arguments and investigations on which this understanding is based. This TDR volume documents the scientific basis underlying the conception and design of the LBNF/DUNE experimental configurations. As a result, the description of DUNE's experimental capabilities constitutes the bulk of the document. Key linkages between requirements for successful execution of the physics program and primary specifications of the experimental configurations are drawn and summarized. This document also serves a wider purpose as a statement on the scientific potential of DUNE as a central component within a global program of frontier theoretical and experimental particle physics research. Thus, the presentation also aims to serve as a resource for the particle physics community at large.
- 7 February 2020
- Published by Office of Scientific and Technical Information (OSTI)
Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume II: DUNE Physics
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume II of this TDR, DUNE Physics, describes the array of identified scientific opportunities and key goals. Crucially, we also report our best current understanding of the capability of DUNE to realize these goals, along with the detailed arguments and investigations on which this understanding is based. This TDR volume documents the scientific basis underlying the conception and design of the LBNF/DUNE experimental configurations. As a result, the description of DUNE's experimental capabilities constitutes the bulk of the document. Key linkages between requirements for successful execution of the physics program and primary specifications of the experimental configurations are drawn and summarized. This document also serves a wider purpose as a statement on the scientific potential of DUNE as a central component within a global program of frontier theoretical and experimental particle physics research. Thus, the presentation also aims to serve as a resource for the particle physics community at large.
- Open Access
Solar Neutrino Measurements in Super-Kamiokande-IV
Upgraded electronics, improved water system dynamics, better calibration and analysis techniques allowed Super-Kamiokande-IV to clearly observe very low-energy 8B solar neutrino interactions, with recoil electron kinetic energies as low as 3.49 MeV. Super-Kamiokande-IV data-taking began in September of 2008; this paper includes data until February 2014, a total livetime of 1664 days. The measured solar neutrino flux is (2.308+-0.020(stat.) + 0.039-0.040(syst.)) x 106/(cm2sec) assuming no oscillations. The observed recoil electron energy spectrum is consistent with no distortions due to neutrino oscillations. An extended maximum likelihood fit to the amplitude of the expected solar zenith angle variation of the neutrino-electron elastic scattering rate in SK-IV results in a day/night asymmetry of (-3.6+-1.6(stat.)+-0.6(syst.))%. The SK-IV solar neutrino data determine the solar mixing angle as sin2 theta_12 = 0.327+0.026-0.031, all SK solar data (SK-I, SK-II, SK III and SKIV) measures this angle to be sin2 theta_12 = 0.334+0.027-0.023, the determined mass-squared splitting is Delta m2_21 = 4.8+1.5-0.8 x10-5 eV2.
Open AccessSolar Neutrino Measurements in Super-Kamiokande-IV
Upgraded electronics, improved water system dynamics, better calibration and analysis techniques allowed Super-Kamiokande-IV to clearly observe very low-energy 8B solar neutrino interactions, with recoil electron kinetic energies as low as 3.49 MeV. Super-Kamiokande-IV data-taking began in September of 2008; this paper includes data until February 2014, a total livetime of 1664 days. The measured solar neutrino flux is (2.308+-0.020(stat.) + 0.039-0.040(syst.)) x 106/(cm2sec) assuming no oscillations. The observed recoil electron energy spectrum is consistent with no distortions due to neutrino oscillations. An extended maximum likelihood fit to the amplitude of the expected solar zenith angle variation of the neutrino-electron elastic scattering rate in SK-IV results in a day/night asymmetry of (-3.6+-1.6(stat.)+-0.6(syst.))%. The SK-IV solar neutrino data determine the solar mixing angle as sin2 theta_12 = 0.327+0.026-0.031, all SK solar data (SK-I, SK-II, SK III and SKIV) measures this angle to be sin2 theta_12 = 0.334+0.027-0.023, the determined mass-squared splitting is Delta m2_21 = 4.8+1.5-0.8 x10-5 eV2.