Turki Almatani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Turki Almatani has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Wafa M. Al-Saleh
3 shared publicationsRichard P. Hugtenburg
2 shared publicationsAfaf Nada
1 shared publicationArtjoms Smakovs
Department of Medical Physics and Clinical Engineering, Swansea Bay University Health Board, Swansea, UK
1 shared publicationHosnia M. Abu-Zeid
1 shared publicationRamadan A. Hassan
1 shared publication
Latest Publications
- Open Access
- 20 February 2026
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 19 (1)
Assessment of radon levels and radiological risk in groundwater of Al-Ahsa Oasis, Eastern Saudi Arabia
- 20 February 2026
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 19 (1)
Open AccessAssessment of radon levels and radiological risk in groundwater of Al-Ahsa Oasis, Eastern Saudi Arabia
- Open Access
- 17 December 2024
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 18 (1)
Modelling of the 6 MV varian clinac iX linear accelerator using EGSnrc for flattening and unflattening beams
- 17 December 2024
- Published by Elsevier in Journal of Radiation Research and Applied Sciences
- Vol. 18 (1)
Open AccessModelling of the 6 MV varian clinac iX linear accelerator using EGSnrc for flattening and unflattening beams
- Open Access
- 18 April 2024
- Published by Taylor & Francis in Journal of Taibah University for Science
- Vol. 18 (1)
Dose enhancement of nanogold for prostate radiation: Monte Carlo simulation using the ICRP voxel computational male phantom
- 18 April 2024
- Published by Taylor & Francis in Journal of Taibah University for Science
- Vol. 18 (1)
Open AccessDose enhancement of nanogold for prostate radiation: Monte Carlo simulation using the ICRP voxel computational male phantom
- Open Access
- 19 February 2024
- Published by Taylor & Francis in Journal of Taibah University for Science
- Vol. 18 (1)
Monte Carlo study on nanogold dose enhancement for breast radiotherapy using an ICRP female computational phantom
- 19 February 2024
- Published by Taylor & Francis in Journal of Taibah University for Science
- Vol. 18 (1)
Open AccessMonte Carlo study on nanogold dose enhancement for breast radiotherapy using an ICRP female computational phantom
- Open Access
- 20 February 2023
- Published by Taylor & Francis in Journal of Taibah University for Science
- Vol. 17 (1)
Investigation of variance reduction techniques on photon fluence and dose calculation efficiency for Elekta Agility head using EGSnrc MC code
The aim of this study is to investigate the effects of these Variance reduction techniques on photon fluence and dose calculation efficiency. Different VRTs available in the BEAMnrc code were used to investigate the simulation efficiency for a 6 MV photon beam from an Elekta Agility head. The optimum combination of directional bremsstrahlung splitting (DBS) and bremsstrahlung cross-section enhancement (BCSE) techniques was investigated for photon fluence and dose calculation efficiency. Further combinations with other VRTs were performed. As a result, the combination of DBS and BCSE was most efficient combination for both efficiencies. Furthermore, the combination of DBS and BCSE with photon splitting VRT in DOSXYZnrc further maximized the efficiency. The setting for combining different VRTs that maximize the photon fluence efficiency at the surface of the phantom can be different to those that maximize the dose efficiency inside the phantom. Different VRT combinations, as presented in this study, can improve the simulation efficiency.
- 20 February 2023
- Published by Taylor & Francis in Journal of Taibah University for Science
- Vol. 17 (1)
Open AccessInvestigation of variance reduction techniques on photon fluence and dose calculation efficiency for Elekta Agility head using EGSnrc MC code
The aim of this study is to investigate the effects of these Variance reduction techniques on photon fluence and dose calculation efficiency. Different VRTs available in the BEAMnrc code were used to investigate the simulation efficiency for a 6 MV photon beam from an Elekta Agility head. The optimum combination of directional bremsstrahlung splitting (DBS) and bremsstrahlung cross-section enhancement (BCSE) techniques was investigated for photon fluence and dose calculation efficiency. Further combinations with other VRTs were performed. As a result, the combination of DBS and BCSE was most efficient combination for both efficiencies. Furthermore, the combination of DBS and BCSE with photon splitting VRT in DOSXYZnrc further maximized the efficiency. The setting for combining different VRTs that maximize the photon fluence efficiency at the surface of the phantom can be different to those that maximize the dose efficiency inside the phantom. Different VRT combinations, as presented in this study, can improve the simulation efficiency.
- Open Access
- 19 March 2022
- Published by Taylor & Francis in Journal of Taibah University for Science
- Vol. 16 (1) , 300-307
A Monte Carlo model of an agility head for a 10-MV photon beam
Objective: Modelling linear accelerator (linac) photon beams using the Monte Carlo (MC) technique is presently the most precise technique with which to calculate radiotherapy beam data. Complicated treatment plans can be achieved by using the Agility multileaf collimator. The focus of this study is to model a linac, integrated with an Agility head, using EGSnrc MC code and to investigate its accuracy compared with actual measurements. Methodology: A 10-MV photon beam from an Agility head installed in an Elekta Synergy linac was simulated using BEAMnrc MC code. Various incident electron energies were used to generate percentage depth dose curves for the MC model and were compared with measurements using gamma analysis (γ). Consequently, the focal spot with different full width half-maximums (FWHMs) was used to tune dose profiles. In addition, any differences in dose profiles were further minimized using different angular divergences. Results: The electron energy of 9.6 MeV was found to represent the best match with the measurements, where the γ pass rate was 100%. For dose profile comparisons, a circular focal spot with an FWHM of 0.45 cm and an angular divergence of 0.04 produced the best match with the measurements. Conclusion: The presented MC linac model integrated with an Agility head for a 10-MV photon beam can be reliably used for dose calculations.- 19 March 2022
- Published by Taylor & Francis in Journal of Taibah University for Science
- Vol. 16 (1) , 300-307
Open AccessA Monte Carlo model of an agility head for a 10-MV photon beam
Objective: Modelling linear accelerator (linac) photon beams using the Monte Carlo (MC) technique is presently the most precise technique with which to calculate radiotherapy beam data. Complicated treatment plans can be achieved by using the Agility multileaf collimator. The focus of this study is to model a linac, integrated with an Agility head, using EGSnrc MC code and to investigate its accuracy compared with actual measurements. Methodology: A 10-MV photon beam from an Agility head installed in an Elekta Synergy linac was simulated using BEAMnrc MC code. Various incident electron energies were used to generate percentage depth dose curves for the MC model and were compared with measurements using gamma analysis (γ). Consequently, the focal spot with different full width half-maximums (FWHMs) was used to tune dose profiles. In addition, any differences in dose profiles were further minimized using different angular divergences. Results: The electron energy of 9.6 MeV was found to represent the best match with the measurements, where the γ pass rate was 100%. For dose profile comparisons, a circular focal spot with an FWHM of 0.45 cm and an angular divergence of 0.04 produced the best match with the measurements. Conclusion: The presented MC linac model integrated with an Agility head for a 10-MV photon beam can be reliably used for dose calculations. - Open Access
- 26 March 2021
- Published by Scientific Scholar in Journal of King Saud University – Science
- Vol. 33 (4) , 101421
Optimisation of variance reduction techniques in EGSnrc Monte Carlo for a 6 MV photon beam of an Elekta Synergy linear accelerator
Objective: Monte Carlo (MC) simulations are considered to be the most accurate form of algorithm for dose calculation. However, the main obstacle to using MC, especially in clinical routine, is the simulation time needed to gain results below a desirable level of uncertainty. Variance reduction techniques (VRTs) have been introduced to reduce the simulation time while maintaining the uncertainty at an acceptable level. The aim of this study is to investigate and optimize the VRTs implemented in EGSnrc MC code, BEAMnrc and DOSXYZnrc. Methodology: The BEAMnrc user code was used to model a 10 × 10 cm2 field size of a 6 MV photon beam from an Elekta Synergy linear accelerator. The DOSXYZnrc user code was used to model a water phantom. The effects of different VRTs on the simulation efficiency were investigated either individually or in combination. The directional bremsstrahlung splitting (DBS) technique was investigated further to find the optimum splitting number and splitting field radius. For DOSXYZnrc, the photon splitting was investigated to find the best combination with the VRTs in BEAMnrc and to find the optimum splitting number. Finally, the best combination of VRTs in both BEAMnrc and DOSXYZnrc was compared with the corresponding phase space (PHSP) simulation source. Results: The DBS technique was found to be the most efficient. The optimum splitting number was found to be 10,000 and 15,000 with and without electron splitting, respectively. For the DBS splitting field radius, overestimating by up to 3 cm would be sufficient without causing a significant loss in efficiency. For both BEAMnrc and DOSXYZnrc, the combination of DBS, bremsstrahlung cross-section enhancement, range rejection with 2 MeV and photon splitting (with optimum splitting number of 35) was the most efficient, and was about 8% less efficient than PHSP simulation. Conclusion: The VRTs implemented in EGSnrc MC code made it possible to achieve an acceptably small uncertainty within a reasonable simulation time, if optimised properly. The combination of VRTs presented in this study eliminates the need to spare a large amount of disk space, and where parallel computing could allow for MC dose calculation in real-time adaptive treatment planning.
- 26 March 2021
- Published by Scientific Scholar in Journal of King Saud University – Science
- Vol. 33 (4) , 101421
Open AccessOptimisation of variance reduction techniques in EGSnrc Monte Carlo for a 6 MV photon beam of an Elekta Synergy linear accelerator
Objective: Monte Carlo (MC) simulations are considered to be the most accurate form of algorithm for dose calculation. However, the main obstacle to using MC, especially in clinical routine, is the simulation time needed to gain results below a desirable level of uncertainty. Variance reduction techniques (VRTs) have been introduced to reduce the simulation time while maintaining the uncertainty at an acceptable level. The aim of this study is to investigate and optimize the VRTs implemented in EGSnrc MC code, BEAMnrc and DOSXYZnrc. Methodology: The BEAMnrc user code was used to model a 10 × 10 cm2 field size of a 6 MV photon beam from an Elekta Synergy linear accelerator. The DOSXYZnrc user code was used to model a water phantom. The effects of different VRTs on the simulation efficiency were investigated either individually or in combination. The directional bremsstrahlung splitting (DBS) technique was investigated further to find the optimum splitting number and splitting field radius. For DOSXYZnrc, the photon splitting was investigated to find the best combination with the VRTs in BEAMnrc and to find the optimum splitting number. Finally, the best combination of VRTs in both BEAMnrc and DOSXYZnrc was compared with the corresponding phase space (PHSP) simulation source. Results: The DBS technique was found to be the most efficient. The optimum splitting number was found to be 10,000 and 15,000 with and without electron splitting, respectively. For the DBS splitting field radius, overestimating by up to 3 cm would be sufficient without causing a significant loss in efficiency. For both BEAMnrc and DOSXYZnrc, the combination of DBS, bremsstrahlung cross-section enhancement, range rejection with 2 MeV and photon splitting (with optimum splitting number of 35) was the most efficient, and was about 8% less efficient than PHSP simulation. Conclusion: The VRTs implemented in EGSnrc MC code made it possible to achieve an acceptably small uncertainty within a reasonable simulation time, if optimised properly. The combination of VRTs presented in this study eliminates the need to spare a large amount of disk space, and where parallel computing could allow for MC dose calculation in real-time adaptive treatment planning.
- Open Access
- 23 March 2021
- Published by Scientific Scholar in Journal of King Saud University – Science
- Vol. 33 (4) , 101406
Validation of a 10 MV photon beam Elekta Synergy linear accelerator using the BEAMnrc MC code
Objective: The Monte Carlo (MC) technique can accurately model any linear accelerator where accurate details about the treatment head and the incident electron beam have been provided. However, manufacturers generally do not provide such details as the energy, radial intensity (spot size), or the angular spread of the incident electron beam. The aim of this study is to predict these details and validate a MC Linac model with the measurements. Methodology: A 10 MV photon beam from an Elekta Synergy Linac was modelled using the BEAMnrc code. The percentage depth dose of the MC model was generated using different electron energies and compared with the measurements using a Gamma index () with two different criteria sets. The dose profiles of the fine-tuned electron energy were generated using different spot sizes and compared with appropriate measurements. In addition, the fine-tuned electron energy and spot size dose profiles were generated using different angular spreads to minimise any differences. Finally, the output factors for different field sizes, with and without a wedge, and also the quality index, were compared. Results: The fine-tuned electron energy of the MC model was found to be 9.8 MeV, where 94.12% of the calculation points pass the test. For the spot size, a circular radial intensity of 0.35 cm best described the 10 MV photon beam. Furthermore, a mean angular spread of 0.05° minimised the cross-field profile differences between calculation and measurement. The largest differences between the output factors from the MC model and measurements were -0.8% and 4.7% for an open and wedged field, respectively. Ultimately, a difference of 0.82% in the quality index was achieved. Conclusion: A reliable MC model of a 10 MV photon beam Elekta Synergy Linac can be achieved as presented in this study using the BEAMnrc code. This model can be reliably used to calculate dose distributions.- 23 March 2021
- Published by Scientific Scholar in Journal of King Saud University – Science
- Vol. 33 (4) , 101406
Open AccessValidation of a 10 MV photon beam Elekta Synergy linear accelerator using the BEAMnrc MC code
Objective: The Monte Carlo (MC) technique can accurately model any linear accelerator where accurate details about the treatment head and the incident electron beam have been provided. However, manufacturers generally do not provide such details as the energy, radial intensity (spot size), or the angular spread of the incident electron beam. The aim of this study is to predict these details and validate a MC Linac model with the measurements. Methodology: A 10 MV photon beam from an Elekta Synergy Linac was modelled using the BEAMnrc code. The percentage depth dose of the MC model was generated using different electron energies and compared with the measurements using a Gamma index () with two different criteria sets. The dose profiles of the fine-tuned electron energy were generated using different spot sizes and compared with appropriate measurements. In addition, the fine-tuned electron energy and spot size dose profiles were generated using different angular spreads to minimise any differences. Finally, the output factors for different field sizes, with and without a wedge, and also the quality index, were compared. Results: The fine-tuned electron energy of the MC model was found to be 9.8 MeV, where 94.12% of the calculation points pass the test. For the spot size, a circular radial intensity of 0.35 cm best described the 10 MV photon beam. Furthermore, a mean angular spread of 0.05° minimised the cross-field profile differences between calculation and measurement. The largest differences between the output factors from the MC model and measurements were -0.8% and 4.7% for an open and wedged field, respectively. Ultimately, a difference of 0.82% in the quality index was achieved. Conclusion: A reliable MC model of a 10 MV photon beam Elekta Synergy Linac can be achieved as presented in this study using the BEAMnrc code. This model can be reliably used to calculate dose distributions.