A Monte Carlo model of an agility head for a 10-MV photon beam
Authors:
Open Access
- 19 March 2022
- journal article
- research article
- Published by Taylor & Francis in Journal of Taibah University for Science
- Vol. 16 (1) , 300-307
Abstract
Objective: Modelling linear accelerator (linac) photon beams using the Monte Carlo (MC) technique is presently the most precise technique with which to calculate radiotherapy beam data. Complicated treatment plans can be achieved by using the Agility multileaf collimator. The focus of this study is to model a linac, integrated with an Agility head, using EGSnrc MC code and to investigate its accuracy compared with actual measurements. Methodology: A 10-MV photon beam from an Agility head installed in an Elekta Synergy linac was simulated using BEAMnrc MC code. Various incident electron energies were used to generate percentage depth dose curves for the MC model and were compared with measurements using gamma analysis (γ). Consequently, the focal spot with different full width half-maximums (FWHMs) was used to tune dose profiles. In addition, any differences in dose profiles were further minimized using different angular divergences. Results: The electron energy of 9.6 MeV was found to represent the best match with the measurements, where the γ pass rate was 100%. For dose profile comparisons, a circular focal spot with an FWHM of 0.45 cm and an angular divergence of 0.04 produced the best match with the measurements. Conclusion: The presented MC linac model integrated with an Agility head for a 10-MV photon beam can be reliably used for dose calculations.
Keywords
This publication has 21 references indexed in Scilit:
- EP-1498: Beam matching of linacs with Elekta agility and MLCi2 heads - Energy, profiles, and output factorsRadiotherapy and Oncology, 2014
- Verification of dosimetric accuracy on the TrueBeam STx: Rounded leaf effect of the high definition MLCMedical Physics, 2012
- Monte Carlo modeling and simulations of the High Definition (HD120) micro MLC and validation against measurements for a 6 MV beamMedical Physics, 2011
- Monte Carlo linear accelerator simulation of megavoltage photon beams: Independent determination of initial beam parametersMedical Physics, 2011
- 6 MV dosimetric characterization of the 160 MLC™, the new Siemens multileaf collimatorMedical Physics, 2008
- Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planningMedical Physics, 2007
- On the discrepancies between Monte Carlo dose calculations and measurements for the Varian photon beamMedical Physics, 2007
- Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM codeMedical Physics, 2002
- A technique for the quantitative evaluation of dose distributionsMedical Physics, 1998
- Monte Carlo techniques in medical radiation physicsPhysics in Medicine & Biology, 1991