SMScott E. Mann

Scott E. Mann

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Scott E. Mann has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Impact of the HeLa Cell in the Field of Otolaryngology: Honoring Henrietta Lacks

    by Taylor L. Jamil, Carissa M. Thomas, Scott Mann, Andrew P. Johnson, Cristina Cabrera‐Muffly

    Introduction: The HeLa cell, which was first taken from Henrietta Lacks in 1952, was the first in vitro cell line discovered and propagated in mass. From polio vaccine development to understanding cancer biology, the HeLa cell has allowed for immeasurable scientific advances. No prior review has examined how the HeLa cell has influenced the field of otolaryngology. Methods: A PRISMA‐style approach was taken in this narrative literature review to understand the historical context of the human papilloma virus (HPV) and how the HeLa cell elucidated HPV‐mediated cancers. Then, using MeSH terminology, each subspecialty of otolaryngology (i.e., head and neck cancer, audiology, otology, rhinology, and laryngology) was used to identify studies that incorporated HeLa cells to understand how HeLa cells made direct impacts on otolaryngology research. Results: The HeLa cell was crucial to identifying how HPV causes tumorigenesis, and due to enhanced cervical cancer knowledge, this boosted head and neck tumor discoveries. Basic biology, such as how cisplatin functions, which is now a common chemotherapeutic used for head and neck cancer, was studied using the HeLa cell line. Due to the cells' reliable, accessible, and rapidly dividing characteristics, the HeLa cell was also used broadly in hearing and sensory research. Discussion: Although the HeLa cell line comes with great bioethical controversy, the HeLa cell has improved the lives of countless people. It is important to consider the lives of historically underserved communities and individuals, such as Henrietta Lacks, to both honor and recognize the contributions diverse people from every racial and economic background make to science.

  • Top Cited Papers
    Open Access

    AI at the Sella Turcica: Multi-Model Large Language Model Evaluation in Pituitary Adenomas

    by Aynur Aliyeva, Edin Nevzati, Fabio Grassia, Muhammad Riaz, Scott Mann, Rauf Nasirov


  • Novel Low‐Cost Open‐Access 3D Printed Microlaryngeal Surgery Trainer

    by Ethan T. Moore, Emily Ambrose, Taylor G. Lackey, Ryan J. Lau, Daniel S. Fink, Scott E. Mann

    Objectives: Otolaryngology trainees often have limited opportunities to practice microlaryngeal surgeries, so there is a need for high‐quality simulation activities to aid in developing these skills. To address this gap, we created a low‐cost, reusable, 3D‐printed microlaryngeal simulator that can be used with various animal/human larynges to practice microlaryngeal surgery. Methods: The simulator was developed through computer‐aided design, iterative prototyping with 3D‐printing, and repeated use in educational activities to guide improvements. Upon completion, a study was performed to evaluate educational value. Porcine larynges were used as a tissue model and study participants included medical students, otolaryngology residents, and laryngologists at the University of Colorado. Participants were instructed to raise a submucosal microflap on the vocal fold. Their simulated operations were video recorded and evaluated by a blinded reviewer to assess construct validity. Participants completed a Modified Michigan Standard Simulation Experience Scale Laryngeal Simulator Questionnaire and answered questions about their confidence performing the procedure to assess face and content validity. Results: The average participant ratings for self‐efficacy, fidelity, educational value, and teaching quality of the simulation experience were above 4/5 for the trainees The average confidence rating for performing microflap surgery increased from 1.8/5 before the simulation to 3.0/5 postsimulation. Experts performed statistically significantly better than novices as determined by blinded review of the procedures. Conclusions: This novel, low‐cost, 3D‐printed surgery trainer allows for the successful practice of microlaryngeal surgery. User‐reported ratings and a blinded review suggest the simulator achieves content, face, and construct validity when used in simulated surgery. Level of Evidence: N/A.


  • Outcomes of Orbit Reconstructive Surgery Utilizing 3D ‐Printed Surgical Guides

    by Scott E. Mann, Ethan T. Moore, Matthew J. Hill, Khaled A. Campa, Sara H. Anderson, Mark J. Glasgow

    Objectives: The purpose of this study is to assess the impact of patient‐specific 3D‐printed surgical guides (3DSG) when utilized during post‐traumatic orbital reconstructive surgery. Methods: Retrospective analysis was conducted of 118 patients who underwent orbital fracture repair at a single institution between January 1, 2018, and July 31, 2024. Inclusion criteria were patients with a unilateral orbital fracture repaired, age over 15, and a postoperative CT scan available. Patients were divided into two groups: those repaired conventionally and those repaired with the use of a 3DSG. Computer‐aided design modeling software was utilized to perform volumetric analysis of postoperative CT scans and characterize the volume of repaired and uninjured orbits. Post‐reconstructive orbital symmetry was calculated and compared between the groups. The frequency of poor orbital volume restoration, defined as volume difference between sides of ≥ 2 mL, 8%, or both, was also compared. Results: Of 118 patients, 87 were repaired conventionally and 31 were repaired with a 3DSG. Asymmetry between the repaired and unaffected orbital volume was greater in the conventional group (1.35 mL, SD ± 0.95 mL) than in the 3DSG group (0.72 mL, SD ± 0.48 mL), p < 0.0001. The incidence of poor postoperative volume restoration was less common when using a 3DSG (3.23% vs. 19.54%, p = 0.039) and NNT of 7. Conclusions: In this retrospective analysis of a single‐center experience, use of patient‐specific 3D surgical guides during reconstruction of unilateral orbital fractures was associated with improved postoperative orbital symmetry and likely decreased risk of postoperative complications such as globe malposition. Level of Evidence : III.


  • Open Access

    Impact of modern recreational conveyances on rates of pediatric craniofacial fractures

    by Scott Hirsch, Tammy Wang, Scott Mann

    Objective: Trauma remains the leading cause of death for children over a year old. Motorized recreational conveyances (RCs) adds another potential cause of pediatric trauma. This study aims to determine the impact of adding electric motors to RCs on the severity and frequency of pediatric injuries and craniofacial fractures.Methods: Pediatric trauma information was obtained from the National Electronic Injury Surveillance System (NEISS) database between 2012 and 2021. Demographics, injury cause, diagnoses, and incident narrative were collected. Bivariate and multivariate regression analyses were used to determine injury factors associated with serious injuries.Results: One million five hundred ninety‐six thousand five hundred fifty‐nine encounters were examined; 113,905 (7.1%) were related to pediatric RCs and 5354 (5.4%) of those involved RCs with electric motors. 14.3% of injuries were related to scooters, 18.6% to skateboards, 54.2% to bicycles, and 12.9% to other RCs. There were significant differences in age, sex, race, helmet use, serious injuries, and craniofacial fractures between RC modalities. RC users were more likely to develop facial fractures (OR 2.12; 95%CI 2.01, 2.23; p < .001) and be involved in serious injuries (OR 1.42; 95%CI 1.38, 1.46; p < .001). Compared to their self‐propelled counterparts, motorized scooters (OR 2.24; 95%CI 1.86, 2.69; p < .001) but not motorized skateboards (OR 1.01; 95%CI 0.88, 1.17; p = 0.88) were more likely to cause serious injuries. Helmet use was associated with fewer serious injuries (OR 0.5; 95%CI 0.46, 0.54; p < .001), facial fractures (OR 0.48; 95%CI 0.41, 0.55; p < .001), and skull fractures (OR 0.13; 95%CI 0.09, 0.17; p < .001).Conclusions: The addition of electric motors to RCs significantly increases the risk of pediatric craniofacial fractures and serious injuries.Level of Evidence: 3.


  • Open Access

    Cerebellar Compression by Giant Extracanalicular Osteoma with Central Cholesterol Granuloma

    by Caroline F. Smith, Conner J. Massey, Scott E. Mann

    Temporal bone osteomas comprise 0.1–1% of benign tumors involving the skull, the majority of which arise in the external auditory canal. More rarely, they can arise from the mastoid portion of the temporal bone. These generally present as a slow growing skull base lesion that can cause cosmetic deformity, headache, and/or hearing loss. Here, we report a case of extracanalicular mastoid osteoma uniquely presenting with posterior fossa and cerebellar compression with associated dizziness and imbalance.

  • Open Access

    Transient patulous eustachian tube in severe anorexia nervosa: A prospective observational study

    by Scott E. Mann, Jeff Hollis, Trudy Frederics, Ashlie Watters, Judy Oakes, Stephen P. Cass, Philip S. Mehler

    Objectives: To understand the presence of transient autophony symptoms in patients being treated for severe anorexia nervosa (AN), and whether those symptoms were due to patulous eustachian tube (PET).Methods: A prospective observational study was performed in patients requiring admission for treatment of severe AN. All enrolled patients completed The Eustachian Tube Dysfunction Questionnaire (ETDQ‐7) and were screened for symptoms of autophony. If patients reported autophony and had a score of ≥14.5 on the ETDQ‐7 they were asked to undergo comprehensive audiological testing and an evaluation with an otolaryngologist.Results: Of the 73 patients enrolled in the study, 35 patients (44%) reported autophony and 36 (49%) scored 14.5 or higher on the ETDQ‐7. Of the 16 (22%) patients who had both autophony and an ETDQ‐7 score of 14.5 or higher, 7 patient s (representing 11 symptomatic ears) underwent evaluations by audiology and otolaryngology. Every evaluation of a symptomatic ear revealed objective evidence of PET. Nine of 11 (81.8%) symptomatic ears had subjectively resolved within 12 days of admission after nutritional rehabilitation and weight gain.Conclusion: Transient autophony in severe AN patients is due to PET, and was present in at least 8% of patients within our cohort. Further study is warranted to understand the quality of life impact and pathophysiology of transient PET in this patient population.


  • Effect of the COVID‐19 Pandemic on Otolaryngology Trainee Surgical Case Numbers: A Multi‐institutional Review

    by Scott Mann, James Duffy, Tyler Muffly, Keval Tilva, Stacey Gray, Laura Hetzler, Shannon Kraft, Sonya Malekzadeh, Steven Pletcher, Cristina Cabrera-Muffly

    Objective: To determine the effect of the initiation of COVID‐19–related restrictions on the volume of surgical cases performed by otolaryngology trainees.Study Design: Multi‐institutional retrospective analysis of resident surgical case logs.Setting: Accredited residency training programs in otolaryngology head and neck surgery.Methods: Resident surgical case logs were combined from 6 residency training programs from different regions of the United States. Case volumes were compared between the calendar year before March 1, 2020, and the year afterward. Subgroup analyses were performed for the type of hospital (university, pediatric, veteran, county) and the key index cases by subspecialty.Results: All 6 participating residency programs had a decrease in resident operative case volume. Surgical volume decreased from a mean of 6014 to 4161 (P < .05). There were decreases observed in key index cases in every subspecialty (P < .01), without statistical differences seen among subspecialties. There were decreases observed in every hospital type (university, pediatric, veteran, county) without statistical differences among types. Postgraduate year 5 residents were the most affected by volume reductions (51.6%), and postgraduate year 3 residents were the least affected (1.4%).Conclusion: In the year following initiation of COVID‐19–related restrictions, there was a significant decrease in trainee surgical case volumes within residencies for otolaryngology–head and neck surgery. There were no statistical differences in the volume decreases seen at different institutions, among hospital types, or within various subspecialties.


  • Autophony in inpatients with anorexia nervosa or avoidant restrictive food intake disorder

    by Jeff Hollis, Scott Mann, Ashlie Watters, Judy Oakes, Philip S. Mehler

    Objective To assess for the prevalence of autophony, a distressing auditory symptom commonly attributed to patulous eustachian tube, in a cohort of individuals with severe malnourishment due to an eating disorder. Method A cross-sectional survey study was performed. Patients admitted for inpatient medical stabilization of an eating disorder, who were also at low body weight, were asked to complete a survey assessing aural symptoms present in the previous 24 hr, including autophony. Anthropometric data and prealbumin levels were collected. Results Of 101 patients enrolled, 43 (42.6%) reported symptoms of autophony. The presence of autophony was associated with lower serum prealbumin levels and lower body weight as measured by percentage of ideal body weight. Discussion Autophony is a commonly reported, albeit rarely discussed, symptom in individuals with severe eating disorders and correlates with degree of malnutrition.