EMEthan T. Moore

Ethan T. Moore

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ethan T. Moore has a total of 44 co-authors. Here are the top co-authors by number of shared publications:

  • Scott E. Mann

    Department of Otolaryngology—Head and Neck Surgery University of Colorado School of Medicine Aurora Colorado USA

    2 shared publications
  • Aksim Rivera

    Department of Surgery, Jacobi Medical Center, Albert Einstein School of Medicine, Bronx, NY, USA

    1 shared publication
  • Amna Ali

    Department of Surgery, University of California San Francisco Fresno, Fresno, CA, USA

    1 shared publication
  • Anna M Darelli-Anderson

    Department of Surgery, University of Utah School of Medicine, Salt Lake City, UT, USA

    1 shared publication
  • Asad Choudhry

    Department of Surgery, SUNY Upstate University Hospital, Syracuse, NY, USA

    1 shared publication
  • Ashley Cosentino

    Department of Surgery, Barnes Jewish Hospital, Washington University School of Medicine, St. Louis, MO, USA

    1 shared publication

Latest Publications

  • Novel Low‐Cost Open‐Access 3D Printed Microlaryngeal Surgery Trainer

    by Ethan T. Moore, Emily Ambrose, Taylor G. Lackey, Ryan J. Lau, Daniel S. Fink, Scott E. Mann

    Objectives: Otolaryngology trainees often have limited opportunities to practice microlaryngeal surgeries, so there is a need for high‐quality simulation activities to aid in developing these skills. To address this gap, we created a low‐cost, reusable, 3D‐printed microlaryngeal simulator that can be used with various animal/human larynges to practice microlaryngeal surgery. Methods: The simulator was developed through computer‐aided design, iterative prototyping with 3D‐printing, and repeated use in educational activities to guide improvements. Upon completion, a study was performed to evaluate educational value. Porcine larynges were used as a tissue model and study participants included medical students, otolaryngology residents, and laryngologists at the University of Colorado. Participants were instructed to raise a submucosal microflap on the vocal fold. Their simulated operations were video recorded and evaluated by a blinded reviewer to assess construct validity. Participants completed a Modified Michigan Standard Simulation Experience Scale Laryngeal Simulator Questionnaire and answered questions about their confidence performing the procedure to assess face and content validity. Results: The average participant ratings for self‐efficacy, fidelity, educational value, and teaching quality of the simulation experience were above 4/5 for the trainees The average confidence rating for performing microflap surgery increased from 1.8/5 before the simulation to 3.0/5 postsimulation. Experts performed statistically significantly better than novices as determined by blinded review of the procedures. Conclusions: This novel, low‐cost, 3D‐printed surgery trainer allows for the successful practice of microlaryngeal surgery. User‐reported ratings and a blinded review suggest the simulator achieves content, face, and construct validity when used in simulated surgery. Level of Evidence: N/A.


  • Outcomes of Orbit Reconstructive Surgery Utilizing 3D ‐Printed Surgical Guides

    by Scott E. Mann, Ethan T. Moore, Matthew J. Hill, Khaled A. Campa, Sara H. Anderson, Mark J. Glasgow

    Objectives: The purpose of this study is to assess the impact of patient‐specific 3D‐printed surgical guides (3DSG) when utilized during post‐traumatic orbital reconstructive surgery. Methods: Retrospective analysis was conducted of 118 patients who underwent orbital fracture repair at a single institution between January 1, 2018, and July 31, 2024. Inclusion criteria were patients with a unilateral orbital fracture repaired, age over 15, and a postoperative CT scan available. Patients were divided into two groups: those repaired conventionally and those repaired with the use of a 3DSG. Computer‐aided design modeling software was utilized to perform volumetric analysis of postoperative CT scans and characterize the volume of repaired and uninjured orbits. Post‐reconstructive orbital symmetry was calculated and compared between the groups. The frequency of poor orbital volume restoration, defined as volume difference between sides of ≥ 2 mL, 8%, or both, was also compared. Results: Of 118 patients, 87 were repaired conventionally and 31 were repaired with a 3DSG. Asymmetry between the repaired and unaffected orbital volume was greater in the conventional group (1.35 mL, SD ± 0.95 mL) than in the 3DSG group (0.72 mL, SD ± 0.48 mL), p < 0.0001. The incidence of poor postoperative volume restoration was less common when using a 3DSG (3.23% vs. 19.54%, p = 0.039) and NNT of 7. Conclusions: In this retrospective analysis of a single‐center experience, use of patient‐specific 3D surgical guides during reconstruction of unilateral orbital fractures was associated with improved postoperative orbital symmetry and likely decreased risk of postoperative complications such as globe malposition. Level of Evidence : III.


  • Impact of COVID-19 on patients undergoing scheduled procedures for chronic venous disease

    by Ethan Moore, Max V Wohlauer, James Dorosh, Mahmood Kabeil, Rafael D Malgor, Leigh A O’bAnion, Gabriel Lopez-Pena, Riley Gillette, Kathryn Colborn, Robert F Cuff, et al.

    Objective: The COVID-19 pandemic has drastically altered the medical landscape. Various strategies have been employed to preserve hospital beds, personal protective equipment, and other resources to accommodate the surges of COVID-19 positive patients, hospital overcapacities, and staffing shortages. This has had a dramatic effect on vascular surgical practice. The objective of this study is to analyze the impact of the COVID-19 pandemic on surgical delays and adverse outcomes for patients with chronic venous disease scheduled to undergo elective operations. Methods: The Vascular Surgery COVID-19 Collaborative (VASCC) was founded in March 2020 to evaluate the outcomes of patients with vascular disease whose operations were delayed. Modules were developed by vascular surgeon working groups and tested before implementation. A data analysis of outcomes of patients with chronic venous disease whose surgeries were postponed during the COVID-19 pandemic from March 2020 through February 2021 was performed for this study. Results: A total of 150 patients from 12 institutions in the United States were included in the study. Indications for venous intervention were: 85.3% varicose veins, 10.7% varicose veins with venous ulceration, and 4.0% lipodermatosclerosis. One hundred two surgeries had successfully been completed at the time of data entry. The average length of the delay was 91 days, with a median of 78 days. Delays for venous ulceration procedures ranged from 38 to 208 days. No patients required an emergent intervention due to their venous disease, and no patients experienced major adverse events following their delayed surgeries. Conclusions: Interventions may be safely delayed for patients with venous disease requiring elective surgical intervention during the COVID-19 pandemic. This finding supports the American College of Surgeons’ recommendations for the management of elective vascular surgical procedures. Office-based labs may be safe locations for continued treatment when resources are limited. Although the interventions can be safely postponed, the negative impact on quality of life warrants further investigation.