Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Peng Zhang has a total of 81 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Acoustic-enhanced fiber optic MZI sensing technology for partial discharge detection in XLPE cable accessories

    by Peng Zhang, Yanpeng Hao, Zikui Shen, Bangwen Yan, Licheng Li

    The research on partial discharge detection using high-sensitivity fiber-optic Mach-Zehnder interferometer (MZI) sensing technology for cable accessory defect recognition is insufficient, which restricts its engineering applications. This paper established a sensitivity frequency-domain model for the acoustic-enhanced structure. Then, an acoustic-enhanced optical fiber MZI sensing system was constructed and the anti-interference capability of the sensing system was analyzed. Finally, the system was used to conduct experimental tests on four types of simulated defects in Cross-linked polyethylene (XLPE) cable accessories, including air gap defects, impurity defects, scratch defects, and moisture defects. The results show that the acoustic-enhanced structure has acoustic amplification capability in the 20-200 kHz frequency range, and acoustic waves can be concentrated at the end of the structure. The acoustic-enhanced fiber-optic MZI sensing system can resist environmental temperature changes and low-frequency vibration interference. It can effectively recognize four types of simulated defects in XLPE cable accessories and outperforms cylindrical fiber-optic MZI sensing systems and piezoelectric transducers sensor. For impurity and moisture defects, the acoustic-enhanced fiber-optic MZI sensing system can detect partial discharges with a minimum charge of 32.0 pC and 54.6 pC, respectively. For air gap and scratch defects, the system has better defect detection ability than high-frequency current transformer, with the initial discharge voltage being 10.0% and 6.8% lower, respectively.


  • Acoustic-Enhanced Fiber-Optic MZI Sensing Technology for Partial Discharge Detection in Silicone Rubber Insulation

    by Peng Zhang, Yanpeng Hao, Zikui Shen, Bangwen Yan, Licheng Li

    The fiber-optic Mach–Zehnder Interferometer (MZI) acoustic sensing technology offers unique advantages in partial discharge (PD) detection. However, its sensitivity for PD detection in silicone rubber insulation remains insufficient, posing significant risks to the safe operation of power equipment. This paper proposes using a fiber-optic MZI system with an acoustic enhancement structure to detect PD in silicone rubber insulation. Firstly, an acoustic-enhanced fiber-optic sensor (AFS) was developed based on the theory of the acoustic black hole. This sensor was then integrated with MZI sensing technology to form a PD detection system. Subsequently, the system was utilized to analyze the frequency-domain response characteristics of the AFS to identify the sensor material with the best performance. Finally, a PD test platform with a needle-plate electrode configuration in silicone rubber was constructed to evaluate the PD detection capability of the AFS. The results indicate that polycarbonate is a suitable material for fabricating AFS. For a needle electrode with a curvature radius of 60 μm in a silicone rubber needle-plate electrode configuration, the AFS can detect a minimum PD magnitude of 56.0 pC. When the curvature radius of the needle electrode is 15 μm, the detection sensitivity of the AFS surpasses that of the high-frequency current transformer, the cylindrical fiber-optic sensor, and the piezoelectric transducers (PZT) sensor. The initial PD voltage detection sensitivity is improved by 7.7%, 25.0%, and 46.1%, respectively. The proposed fiber-optic MZI system with an acoustic enhancement structure significantly improves the sensitivity of PD detection in silicone rubber insulation.


  • Fiber Optic Mach-Zehnder Interferometer Sensor With Acoustic Enhancement for Partial Discharge Acoustic Emission Detection

    by Peng Zhang, Yanpeng Hao, Zikui Shen, Haotian Tan, Licheng Li

    The application prospects of fiber optic Mach-Zehnder Interferometer (MZI) acousto-sensing technology in the field of partial discharge detection are promising. However, current external fiber optic sensors are not sensitive enough to effectively detect partial discharges. There is an urgent need to increase sensor sensitivity. In this paper, a power-function-curved mandrel sensor (PMS) with an acoustic wave enhancement function was developed, and a fiber MZI acoustic wave sensing system was built. Based on the standard sinusoidal signal, the amplitude and frequency response characteristics of the sensor were measured, and the influence of the mandrel curved surface length on the system sensitivity was studied. The results show that the PMS possesses enhanced acousto-sensing effects. When driven by a piezoelectric transducer emitting 40 kHz acoustic waves at 0.36 V, the PMS achieved the lowest detection threshold of the system, which is 0.44 V lower than that of the cylindrical mandrel sensor (CMS). In the 2-60 kHz frequency range, the sensitivity of the PMS is 41.0% higher than that of the CMS, with an average sensitivity increase of 50.4%. At low frequencies, the signal-to-noise ratio of the sensor improves with an increase in the length of the mandrel curved surface. Finally, the effectiveness of the sensing system for detecting rod-rod electrode discharges was tested. It was found that response peak-to-peak value of the PMS is higher than that of the CMS, proving that the acoustic sensing system can be used for external sensing of power equipment discharges.


  • Open Access

    Torsional Optical Fiber Stress Analysis and Vortex-Induced Vibration Study of Three-Core Submarine Cable

    by Haotian Tan, Yanpeng Hao, Peng Zhang, Qishun Li, Wanxing Tian, Linhao Chen, Lin Yang, Licheng Li

    Due to current scouring, submarine cables are prone to be exposed, suspended, and even vortex-induced vibration, which is not conducive to the safe operation of the power grid. In this contribution, the finite element simulation model of a 35 kV three-core optical fiber composite submarine cable with a suspended span length of 9.5 m is established. The natural frequency of the model is obtained through modal analysis. Then the vortex-induced vibration is simulated by the fluid–structure coupling method, and the stress distribution and change law of the torsional optical fiber is extracted. The results show that in the submarine cable, there appears to be a beating vibration and locking phenomena respectively, under two flow velocities. The transverse vibration amplitude of the latter increases significantly due to a resonance state. When the flow direction is perpendicular to the submarine cable, the stress distribution of the torsional optical fiber at the initial moment and at the 1/2 T moment of a vibration cycle approximately represents a mirror image relationship. In addition, the frequency of the stress change is the same as the frequency of the vortex-induced vibration, which can judge whether the vortex-induced vibration occurs. Moreover, the vortex-induced vibration range can be determined by the maximum stress change location.


  • Open Access

    Numerical Study of the Local Scouring Process and Influencing Factors of Semi-Exposed Submarine Cables

    by Qishun Li, Yanpeng Hao, Peng Zhang, Haotian Tan, Wanxing Tian, Linhao Chen, Lin Yang

    Local scouring might result in the spanning of submarine cables, endangering their mechanical and electrical properties. In this contribution, a three-dimensional computational fluid dynamics simulation model is developed using FLOW-3D, and the scouring process of semi-exposed submarine cables is investigated. The effects of the sediment critical Shields number, sediment density, and ocean current velocity on local scouring are discussed, and variation rules for the submarine cables’ spanning time are provided. The results indicate that three scouring holes are formed around the submarine cables. The location of the bottom of the holes corresponds to that of the maximum shear velocity. The continuous development of scouring holes at the wake position leads to the spanning of the submarine cables. The increase in the sediment’s critical Shields number and sediment density, as well as the decrease in the ocean current velocity, will extend the time for maintaining the stability of the upstream scouring hole and retard the development velocity of the wake position and downstream scouring holes. The spanning time has a cubic relationship with the sediment’s critical Shields number, a linear relationship with the sediment density, and an exponential relationship with the ocean current velocity. In this paper, the local scouring process of semi-exposed submarine cables is studied, which provides a theoretical basis for the operation and maintenance of submarine cables.


  • Association of the components of ambient fine particulate matter (PM2.5) and chronic kidney disease prevalence in China

    by Xingyuan Zhang, Jiayi Tao, Fang Lei, Tao Sun, Lijin Lin, Xuewei Huang, Peng Zhang, Yan-Xiao Ji, Jingjing Cai, Xiao-Jing Zhang, et al.


  • Associations between short-term exposure of ambient particulate matter and hemodialysis patients death: A nationwide, longitudinal case-control study in China

    by Xiaowei Lou, Ping Zhang, Nan Shi, Zhe Ding, Zhonggao Xu, Bicheng Liu, Wenbo Hu, Tiekun Yan, Jinwen Wang, Ling Liu, et al.


  • Open Access

    Effect of Acetylated SEBS/PP for Potential HVAC Cable Insulation

    by Peng Zhang, Xuan Wang, Jiaming Yang, Yongqi Zhang

    Blending polypropylene (PP) with thermoplastic elastomer SEBS can effectively improve the mechanical toughness of PP, thus leading to the promise of SEBS/PP as the primary insulation material for high voltage alternating current (HVAC) cables. However, the growth of electrical trees during cable operation limits the application of SEBS/PP. In this paper, acetylation reaction is used to construct acetophenone group at the end of the benzene ring on SEBS so that it has the effect of both a toughening agent and a voltage stabilizer. Then PP was melt blended with acetylated SEBS (Ac-SEBS), and the effects of Ac-SEBS on the mechanical properties, electrical tree resistance, alternating current (AC) breakdown strength, and dielectric spectrum of PP were mainly investigated with reference to PP and SEBS/PP. The results showed that Ac-SEBS with 30% content could enhance the mechanical toughness of PP and improve the electrical tree resistance and AC breakdown strength of SEBS/PP. The AC breakdown field strength of Ac-SEBS/PP reached the highest when the acetylation level was 4.6%, which was 9.2% higher than that of SEBS/PP. At this time, Ac-SEBS was also able to absorb high-energy electrons through the keto-enol interchange isomerization reaction, which inhibited the initiation and growth of electric trees and caused the development of electric dendrites in a jungle-like manner. Moreover, the dielectric loss factor of AC-SEBS/PP in power frequency is within the allowable range of industry. Therefore, Ac-SEBS/PP is expected to be applied to HVAC cables, thus further improving the efficiency of HVAC power transmission.


  • Open Access

    Effect of Acetylated SEBS/PP for Potential HVDC Cable Insulation

    by Peng Zhang, Yongqi Zhang, Xuan Wang, Jiaming Yang, Wenbin Han

    Blending thermoplastic elastomers into polypropylene (PP) can make it have great potential for high-voltage direct current (HVDC) cable insulation by improving its toughness. However, when a large amount of thermoplastic elastomer is blended, the electrical strength of PP will be decreased consequently, which cannot meet the electrical requirements of HVDC cables. To solve this problem, in this paper, the inherent structure of thermoplastic elastomer SEBS was used to construct acetophenone structural units on its benzene ring through Friedel–Crafts acylation, making it a voltage stabilizer that can enhance the electrical strength of the polymer. The DC electrical insulation properties and mechanical properties of acetylated SEBS (Ac-SEBS)/PP were investigated in this paper. The results showed that by doping 30% Ac-SEBS into PP, the acetophenone structural unit on Ac-SEBS remarkably increased the DC breakdown field strength of SEBS/PP by absorbing high-energy electrons. When the degree of acetylation reached 4.6%, the DC breakdown field strength of Ac-SEBS/ PP increased by 22.4% and was a little higher than that of PP. Ac-SEBS, with high electron affinity, is also able to reduce carrier mobility through electron capture, resulting in lower conductivity currents in SEBS/PP and suppressing space charge accumulation to a certain extent, which enhances the insulation properties. Besides, the highly flexible Ac-SEBS can maintain the toughening effect of SEBS, resulting in a remarkable increase in the tensile strength and elongation at the break of PP. Therefore, Ac-SEBS/PP blends possess excellent insulation properties and mechanical properties simultaneously, which are promising as insulation materials for HVDC cables.