NPNisanard Pisuchpen

Nisanard Pisuchpen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nisanard Pisuchpen has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Prostate imaging reporting and data system version 2.1 as a predictor of clinically significant and aggressive prostate cancer: a radical prostatectomy-validated study

    by Nisanard Pisuchpen, Kulyada Eurboonyanun, Aileen O’SHea, Rita Maria Lahoud, Isha D. Atre, Mukesh Harisinghani

    Original Article Prostate imaging reporting and data system version 2.1 as a predictor of clinically significant and aggressive prostate cancer: a radical prostatectomy-validated study Nisanard Pisuchpen, Kulyada Eurboonyanun, Aileen O’Shea, Rita Maria Lahoud, Isha D. Atre, Mukesh Harisinghani

  • Artificial intelligence (AI) and CT in abdominal imaging: image reconstruction and beyond

    by Nisanard Pisuchpen, Shravya Srinivas Rao, Yoshifumi Noda, Sasiprang Kongboonvijit, Abbas Rezaei, Avinash Kambadakone

    Computed tomography (CT) is a cornerstone of abdominal imaging, playing a vital role in accurate diagnosis, appropriate treatment planning, and disease monitoring. The evolution of artificial intelligence (AI) in imaging has introduced deep learning-based reconstruction (DLR) techniques that enhance image quality, reduce radiation dose, and improve workflow efficiency. Traditional image reconstruction methods, including filtered back projection (FBP) and iterative reconstruction (IR), have limitations such as high noise levels and artificial image texture. DLR overcomes these challenges by leveraging convolutional neural networks to generate high-fidelity images while preserving anatomical details. Recent advances in vendor-specific and vendor-agnostic DLR algorithms, such as TrueFidelity, AiCE, and Precise Image, have demonstrated significant improvements in contrast-to-noise ratio, lesion detection, and diagnostic confidence across various abdominal organs, including the liver, pancreas, and kidneys. Furthermore, AI extends beyond image reconstruction to applications such as low contrast lesion detection, quantitative imaging, and workflow optimization, augmenting radiologists’ efficiency and diagnostic accuracy. However, challenges remain in clinical validation, standardization, and widespread adoption. This review explores the principles, advancements, and future directions of AI-driven CT image reconstruction and its expanding role in abdominal imaging.


  • Detectability of Hypoattenuating Liver Lesions with Deep Learning CT Reconstruction: A Phantom and Patient Study

    by Jinjin Cao, Nayla Mroueh, Nathaniel Mercaldo, Simon Lennartz, Sasiprang Kongboonvijit, Shravya Srinivas Rao, Nisanard Pisuchpen, Vinit Baliyan, Theodore T. Pierce, Mark A. Anderson, et al.

    There were no differences in radiologist performance for detecting hypoattenuating liver lesions at abdominal CT between adaptive statistical iterative reconstruction-V at 40% strength and deep learning image reconstruction with different strengths.


  • CT image quality evaluation in the age of deep learning: trade-off between functionality and fidelity

    by Kai Yang, Jinjin Cao, Nisanard Pisuchpen, Avinash Kambadakone, Rajiv Gupta, Theodore Marschall, Xinhua Li, Bob Liu

    Objective To quantitatively compare DLIR and ASiR-V with realistic anatomical images. Methods CT scans of an anthropomorphic phantom were acquired using three routine protocols (brain, chest, and abdomen) at four dose levels, with images reconstructed at five levels of ASiR-V and three levels of DLIR. Noise power spectrum (NPS) was estimated using a difference image by subtracting two matching images from repeated scans. Using the max-dose FBP reconstruction as the ground truth, the structure similarity index (SSIM) and gradient magnitude (GM) of difference images were evaluated. Image noise magnitude (σ), frequency location of the NPS peak (fpeak), mean SSIM (MSSIM), and mean GM (MGM) were used as quantitative metrics to compare image quality, for each anatomical region, protocol, algorithm, dose level, and slice thickness. Results Image noise had a strong (R2 > 0.99) power law relationship with dose for all algorithms. For the abdomen and chest, fpeak shifted from 0.3 (FBP) down to 0.15 mm-1 (ASiR-V 100%) with increasing ASiR-V strength but remained 0.3 mm-1 for all DLIR levels. fpeak shifted down for the brain protocol with increasing DLIR levels. Three levels of DLIR produced similar image noise levels as ASiR-V 40%, 80%, and 100%, respectively. DLIR had lower MSSIM but higher MGM than ASiR-V while matching imaging noise. Conclusion Compared to ASiR-V, DLIR presents trade-offs between functionality and fidelity: it has a noise texture closer to FBP and more edge enhancement, but reduced structure similarity. These trade-offs and unique protocol-dependent behaviors of DLIR should be considered during clinical implementation and deployment. Key Points • DLIR reconstructed images demonstrate closer noise texture and lower structure similarity to FBP while producing equivalent noise levels comparable to ASiR-V. • DLIR has additional edge enhancement as compared to ASiR-V. • DLIR has unique protocol-dependent behaviors that should be considered for clinical implementation.


  • Concordance of EUS and MRI/MRCP findings among high-risk individuals undergoing pancreatic cancer screening

    by Ava Siegel, Madeline Friedman, Dan Feldman, Kumar Krishnan, Brenna Casey, Nisanard Pisuchpen, Avinash Kambadakone, Daniel C. Chung


  • The absolute tumor-capsule contact length in the diagnosis of extraprostatic extension of prostate cancer

    by Kulyada Eurboonyanun, Nisanard Pisuchpen, Aileen O’sHea, Rita Maria Lahoud, Isha D. Atre, Mukesh Harisinghani

    Background Extraprostatic extension (EPE) of prostate cancer is associated with a poor prognosis. The broad-based capsule-tumor interface has been recognized as one of the worrisome imaging features in multiparametric prostate MRI (mpMRI). However, there was significant heterogeneity among the measurement method used in prior studies. Objectives This study’s objectives were to investigate and compare the accuracy between the curvilinear and linear measurement, find the optimal cut-off contact surface threshold for the diagnosis of EPE, and assess the benefit of the additional contact surface measurement versus visual assessment alone. Methods The status of EPE in mpMRI and the overall PI-RADS were assessed. The tumor’s dimensions, the actual tumor-capsule contact length (ACTCL), and the absolute tumor-capsule contact length (ABTCL) were measured. The parameters were analyzed and correlated with the EPE status from prostatectomy specimens. Results Ninety-five patients who underwent mpMRI followed by prostatectomy were included in the study. High Gleason score (score 8–9), radiologist’s impression of EPE, and PI-RADS 5 were significantly correlated with EPE in surgical specimens (p = 0.014, p < 0.001, and p < 0.001, respectively). Both ACTCL and ABTCL of patients with EPE were significantly higher than those without EPE in all imaging sequences (p < 0.001 to p = 0.003). The ABTCL has higher accuracy than the ACTCL. Dynamic contrast enhancement (DCE) was the most accurate sequence to measure the contact interface. The recommended cut-off value of ABTCL was 15.0 mm, which had a sensitivity and specificity of 75.86% and 72.09%. Multivariable analysis revealed that the ABTCL > 15 mm and the radiologist’s impression on visual assessment were the only two independent predictors for the prediction of EPE (p = 0.048 and p = 0.016, respectively). Improvement of diagnostic performance was achieved when the two factors were combined. Conclusion The ABTCL has better accuracy than the curvilinear measurement in the prediction of EPE. The optimum sequence for the measurement of the contact surface is the DCE. We recommended using 15.0 mm as a cut-off point. Clinical impact The addition of the ABTCL measurement showed an increase in diagnostic performance. We encourage radiologists to use the capsular contact measurement in addition to their visual assessment to detect EPE in pre-operative MRI.