Vahti Kılıç
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Vahti Kılıç has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Enise Betül Göçer
ERCİYES ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ, KLİNİK BİLİMLER BÖLÜMÜ, RESTORATİF DİŞ TEDAVİSİ ANABİLİM DALI
3 shared publications - Seda Baktır
Department of Restorative Dentistry, Faculty of Dentistry, Erciyes University, Kayseri, Turkey
3 shared publications Feridun Hürmüzlü
Professor. Department of Restorative Dentistry, Faculty of Dentistry, Lokman Hekim University, Ankara, Turkey
2 shared publications- Feridun Hürmüzlü
Lokman Hekim Universitesi
2 shared publications - Nihal Şenol
ERCİYES ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ, KLİNİK BİLİMLER BÖLÜMÜ, RESTORATİF DİŞ TEDAVİSİ ANABİLİM DALI
2 shared publications - Adem Gök
Department of Restorative Dentistry, Faculty of Dentistry, Fırat University, 23200 Elazığ, Türkiye
1 shared publication
Latest Publications
- Open Access
- 10 September 2026
- Published by Springer Nature in BMC Oral Health
Performance of artificial intelligence chatbots in restorative dentistry: a comparative analysis of clinical and theoretical specialty examination questions
- 10 September 2026
- Published by Springer Nature in BMC Oral Health
Open AccessPerformance of artificial intelligence chatbots in restorative dentistry: a comparative analysis of clinical and theoretical specialty examination questions
- Open Access
- 29 July 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
Color adjustment potential of one-shade composite resins in repaired CAD/CAM blocks: effect of restoration depth, staining, and material type
This study evaluated the effects of CAD/CAM block type, composite resin type, restoration depth, and staining condition on the instrumental and visual colo
- 29 July 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
Open AccessColor adjustment potential of one-shade composite resins in repaired CAD/CAM blocks: effect of restoration depth, staining, and material type
This study evaluated the effects of CAD/CAM block type, composite resin type, restoration depth, and staining condition on the instrumental and visual colo
- 29 April 2026
- Published by Akdeniz University in Akdeniz Diş Hekimliği Dergisi
- Vol. 5 (1) , 19-29
Evaluation of Immediate Post-Polymerization Color Change in One-Shade and Multi-Shade Composite Resins Polymerized with Different Light-Curing Units
ObjectivesThis study aimed to evaluate the effect of different light-curing units on the immediate post-polymerization color change of one-shade and multi-shade composite resins.Material and MethodsEight composite resins, comprising 4 universal one-shade (Omnichroma, Charisma Diamond One, Essentia Universal, and Vittra APS Unique) and 4 multi-shade composite resins (Estelite Sigma Quick, Gænial Universal Injectable, Optishade Universal, and Filtek Ultimate) were evaluated. Standardized specimens were prepared using 8 mm-diameter, 2 mm-thickness Teflon molds (n = 10). Baseline color measurements were obtained with a contact-type spectrophotometer (Vita Easyshade Compact) before polymerization. Then the specimens were polymerized using 4 different light-curing units (Elipar S10, VALO Cordless, Woodpecker LED.E, and Woodpecker iLed), and second color measurements were performed. Color differences were calculated using the CIEDE2000 formula. Data were analyzed using a two-way ANOVA and post hoc Tukey tests, with α = 0.05.ResultsStatistically significant differences in color change were observed among the tested composite resins and light-curing units (P ≤ 0.05). The ΔE00 values ranged from 3.75 to 13.93. The most significant color change was detected in the Omnichroma group polymerized with the Woodpecker iLed unit (ΔE00 = 13.93). In contrast, Estelite Sigma Quick demonstrated the lowest color change when cured with the VALO Cordless (ΔE00 = 3.75).ConclusionWithin the limitations of this study, both the type of composite resin and the light-curing units significantly influenced post-polymerization color change. Therefore, shade selection should be performed after polymerization, and the same light-curing unit should be used for polymerization to achieve optimal aesthetic outcomes in clinical practice.
- 29 April 2026
- Published by Akdeniz University in Akdeniz Diş Hekimliği Dergisi
- Vol. 5 (1) , 19-29
Evaluation of Immediate Post-Polymerization Color Change in One-Shade and Multi-Shade Composite Resins Polymerized with Different Light-Curing Units
ObjectivesThis study aimed to evaluate the effect of different light-curing units on the immediate post-polymerization color change of one-shade and multi-shade composite resins.Material and MethodsEight composite resins, comprising 4 universal one-shade (Omnichroma, Charisma Diamond One, Essentia Universal, and Vittra APS Unique) and 4 multi-shade composite resins (Estelite Sigma Quick, Gænial Universal Injectable, Optishade Universal, and Filtek Ultimate) were evaluated. Standardized specimens were prepared using 8 mm-diameter, 2 mm-thickness Teflon molds (n = 10). Baseline color measurements were obtained with a contact-type spectrophotometer (Vita Easyshade Compact) before polymerization. Then the specimens were polymerized using 4 different light-curing units (Elipar S10, VALO Cordless, Woodpecker LED.E, and Woodpecker iLed), and second color measurements were performed. Color differences were calculated using the CIEDE2000 formula. Data were analyzed using a two-way ANOVA and post hoc Tukey tests, with α = 0.05.ResultsStatistically significant differences in color change were observed among the tested composite resins and light-curing units (P ≤ 0.05). The ΔE00 values ranged from 3.75 to 13.93. The most significant color change was detected in the Omnichroma group polymerized with the Woodpecker iLed unit (ΔE00 = 13.93). In contrast, Estelite Sigma Quick demonstrated the lowest color change when cured with the VALO Cordless (ΔE00 = 3.75).ConclusionWithin the limitations of this study, both the type of composite resin and the light-curing units significantly influenced post-polymerization color change. Therefore, shade selection should be performed after polymerization, and the same light-curing unit should be used for polymerization to achieve optimal aesthetic outcomes in clinical practice.
- Open Access
- 29 April 2025
- Published by Diş Hekimliği Fakültesi, Harran Üniversitesi in HRU International Journal of Dentistry and Oral Research
- Vol. 5 (1) , 12-19
Evaluation of Color-Matching Ability of Different Single-Shade Composites in Repair of Aesthetic Composite Resins
Aim: The aim of the study was to evaluate the color-matching ability of four different single-shade composite resins used to repair of two multi-shade aesthetic composite resins after thermal aging. Materials and Methods: A total of 100 disc-shaped samples, 50 from each of two aesthetic composites [GC Kalore (GC), A2 and Filtek™ Ultimate (FU), A2 body] were prepared with a height of 4 mm and a diameter of 10 mm. After initial surface preparation, the samples were aged through 5,000 thermal cycles. Subsequently, the surfaces were treated again using Sof- Lex discs and stored in distilled water at 37 ºC for 24 hours. Initial color parameters (L1, a1, b1, C1, h1) were measured using a clinical spectrophotometer. The samples in each group were then randomly divided into five groups (n = 10 each) and numbered. Cavities of 2 mm depth and 6 mm diameter were prepared on the sample surfaces. After acid etching for 30 seconds, a two-step total-etch adhesive (Adper Single Bond 2) was applied, and the cavities were filled with four different single-shade composite resins (Omnichroma, Vittra APS Unique, Charisma Topaz One and Olident ONEshade). Control groups were restored with FU and GC. After polymerization procedure, the samples were again subjected to surface treatment with the disc polishing system and stored in distilled water at 37 ºC for 24 hours. Final color parameters (L2, a2, b2, C2, h2) were measured, and the color change (ΔE00) was calculated using the CIEDE2000 formula. The data were analyzed using two-way ANOVA and post-hoc Tukey tests. Results: The ΔE00 values varied significantly depending on the single-shade composite used (p
- 29 April 2025
- Published by Diş Hekimliği Fakültesi, Harran Üniversitesi in HRU International Journal of Dentistry and Oral Research
- Vol. 5 (1) , 12-19
Open AccessEvaluation of Color-Matching Ability of Different Single-Shade Composites in Repair of Aesthetic Composite Resins
Aim: The aim of the study was to evaluate the color-matching ability of four different single-shade composite resins used to repair of two multi-shade aesthetic composite resins after thermal aging. Materials and Methods: A total of 100 disc-shaped samples, 50 from each of two aesthetic composites [GC Kalore (GC), A2 and Filtek™ Ultimate (FU), A2 body] were prepared with a height of 4 mm and a diameter of 10 mm. After initial surface preparation, the samples were aged through 5,000 thermal cycles. Subsequently, the surfaces were treated again using Sof- Lex discs and stored in distilled water at 37 ºC for 24 hours. Initial color parameters (L1, a1, b1, C1, h1) were measured using a clinical spectrophotometer. The samples in each group were then randomly divided into five groups (n = 10 each) and numbered. Cavities of 2 mm depth and 6 mm diameter were prepared on the sample surfaces. After acid etching for 30 seconds, a two-step total-etch adhesive (Adper Single Bond 2) was applied, and the cavities were filled with four different single-shade composite resins (Omnichroma, Vittra APS Unique, Charisma Topaz One and Olident ONEshade). Control groups were restored with FU and GC. After polymerization procedure, the samples were again subjected to surface treatment with the disc polishing system and stored in distilled water at 37 ºC for 24 hours. Final color parameters (L2, a2, b2, C2, h2) were measured, and the color change (ΔE00) was calculated using the CIEDE2000 formula. The data were analyzed using two-way ANOVA and post-hoc Tukey tests. Results: The ΔE00 values varied significantly depending on the single-shade composite used (p
- Open Access
- 29 April 2025
- Published by Diş Hekimliği Fakültesi, Harran Üniversitesi in HRU International Journal of Dentistry and Oral Research
- Vol. 5 (1) , 36-39
Rehabilitation of Anterior Region Tooth Size Discrepancies After Orthodontic Treatment: A Case Series
Multidisciplinary approaches are used to treat aesthetic and functional problems related to teeth. Following orthodontic treatment, patients may require restorative dental treatment for aesthetic adjustments. Especially in maxillary anterior region, direct composite resin restorations which are one of the restorative treatment options following orthodontic treatment are frequently preferred today due to their minimal invasive and conservative nature. In this case report, it was aimed to eliminate the aesthetic problems observed due to tooth size discrepancies in the anterior region of the maxillary arch with direct composite resin restorations after orthodontic treatment. The patients whose orthodontic treatments were about to be completed at the xxxxxxxx University Department of Orthodontics were referred to the Department of Restorative Dentistry for consultation regarding their aesthetic complaints in the anterior maxillary region before debonding. As a result of intraoral examinations of three patients, tooth size discrepancies and consequently polydiastema were observed. Following the evaluation, it was decided to apply direct aesthetic composite resin restorations to the cases. Tooth size discrepancies and diastemas observed after orthodontic treatment were rehabilitated using direct composite restorations. Minimally invasive rehabilitation of aesthetic problems after orthodontic treatment is possible with direct composite resins.
- 29 April 2025
- Published by Diş Hekimliği Fakültesi, Harran Üniversitesi in HRU International Journal of Dentistry and Oral Research
- Vol. 5 (1) , 36-39
Open AccessRehabilitation of Anterior Region Tooth Size Discrepancies After Orthodontic Treatment: A Case Series
Multidisciplinary approaches are used to treat aesthetic and functional problems related to teeth. Following orthodontic treatment, patients may require restorative dental treatment for aesthetic adjustments. Especially in maxillary anterior region, direct composite resin restorations which are one of the restorative treatment options following orthodontic treatment are frequently preferred today due to their minimal invasive and conservative nature. In this case report, it was aimed to eliminate the aesthetic problems observed due to tooth size discrepancies in the anterior region of the maxillary arch with direct composite resin restorations after orthodontic treatment. The patients whose orthodontic treatments were about to be completed at the xxxxxxxx University Department of Orthodontics were referred to the Department of Restorative Dentistry for consultation regarding their aesthetic complaints in the anterior maxillary region before debonding. As a result of intraoral examinations of three patients, tooth size discrepancies and consequently polydiastema were observed. Following the evaluation, it was decided to apply direct aesthetic composite resin restorations to the cases. Tooth size discrepancies and diastemas observed after orthodontic treatment were rehabilitated using direct composite restorations. Minimally invasive rehabilitation of aesthetic problems after orthodontic treatment is possible with direct composite resins.
- Open Access
- 28 April 2025
- Published by Necmettin Erbakan Universitesi Dis Hekimligi Dergisi (NEU Dent J), Necmettin Erbakan University in Necmettin Erbakan Universitesi Dis Hekimligi Dergisi (NEUDentJ), Necmettin Erbakan
- Vol. 7 (1) , 41-50
Effect of Whitening Mouthwashes on Color Change of Colored One Shade Composite Resins
Aim: The aim of this study was to evaluate the effects of different whitening mouthwashes on the color change of stained four different one-shade composite resins and to compare them with a multi-shade composite. Materials and Methods: A multi-shade (Filtek Ultimate) and four one-shade (Omnichroma, Charisma Diamond One, Essentia Universal, Vittra Unique) composite resins were used. A total of 160 samples, 32 of each composite were prepared and the initial color parameters of the composite samples were measured with a spectrophotometer and the composite samples in each group were divided into four groups (n=8). Then, the samples were kept in coffee and second color measurements were made. After the samples were kept in four whitening mouthwashes (Colgate Optic White, Listerin Advanced White, Pasta del Capitano Whitening, SPLAT® Professional Bio-Active), third color measurements were made and color changes were calculated with the CIEDE2000 formula. Statistical analyzes were performed using one-way ANOVA and post-hoc Tukey's test. Results: The color changes observed in the stained composite resins after immersion in mouthwash were statistically significant, varying by mouthwashes and composites (p≤0.05). Average color change values (ΔE00) were between 0.85 and 4.87. While the highest color change was observed in the Charisma Diamond One group using Pasta del Capitano Whitening (ΔE00=4.87), the lowest color change in all groups was observed in the use of SPLAT® Professional Bio-Active. Conclusion: One-shade composites showed more color change than the multi-shade composite, with variations depending on the mouthwash used. Almost all groups, whitening mouthwashes caused a color change above the perceptibility threshold level.
- 28 April 2025
- Published by Necmettin Erbakan Universitesi Dis Hekimligi Dergisi (NEU Dent J), Necmettin Erbakan University in Necmettin Erbakan Universitesi Dis Hekimligi Dergisi (NEUDentJ), Necmettin Erbakan
- Vol. 7 (1) , 41-50
Open AccessEffect of Whitening Mouthwashes on Color Change of Colored One Shade Composite Resins
Aim: The aim of this study was to evaluate the effects of different whitening mouthwashes on the color change of stained four different one-shade composite resins and to compare them with a multi-shade composite. Materials and Methods: A multi-shade (Filtek Ultimate) and four one-shade (Omnichroma, Charisma Diamond One, Essentia Universal, Vittra Unique) composite resins were used. A total of 160 samples, 32 of each composite were prepared and the initial color parameters of the composite samples were measured with a spectrophotometer and the composite samples in each group were divided into four groups (n=8). Then, the samples were kept in coffee and second color measurements were made. After the samples were kept in four whitening mouthwashes (Colgate Optic White, Listerin Advanced White, Pasta del Capitano Whitening, SPLAT® Professional Bio-Active), third color measurements were made and color changes were calculated with the CIEDE2000 formula. Statistical analyzes were performed using one-way ANOVA and post-hoc Tukey's test. Results: The color changes observed in the stained composite resins after immersion in mouthwash were statistically significant, varying by mouthwashes and composites (p≤0.05). Average color change values (ΔE00) were between 0.85 and 4.87. While the highest color change was observed in the Charisma Diamond One group using Pasta del Capitano Whitening (ΔE00=4.87), the lowest color change in all groups was observed in the use of SPLAT® Professional Bio-Active. Conclusion: One-shade composites showed more color change than the multi-shade composite, with variations depending on the mouthwash used. Almost all groups, whitening mouthwashes caused a color change above the perceptibility threshold level.
- Open Access
- 31 July 2024
- Published by Zeus Publishing in Journal of Medical and Dental Investigations
- Vol. 5, e240325
Clinical applications and improvement of resin bonding for PEEK in resin-bonded fixed dental prosthesis: A review
Resin-bonded fixed dental prostheses (RBFDPs) are a commonly used precision treatment, such as fixed dental prosthesis (FDP) and implant-supported dentures. Full crown preparation of vital teeth, which is required for traditional FDPs, may result in a risk of pulp reaction as a large portion of the coronal tooth structure must be removed. RBFDP has been recognized as a non-invasive or minimally invasive treatment modality for the replacement of single missing teeth. RBFDPs require much less tooth preparation than conventional FDPs. These dental treatments are restorative solutions used to cover missing teeth and achieve an aesthetic smile. The biomechanical rules, aesthetics, polishability, and bond strength have been emphasized in RBFDP treatments. Polyetheretherketone (PEEK) is one of the most widely used biomaterials in dentistry. The material, which stands out especially with its acceptable aesthetics, biocompatibility and modulus of elasticity close to dentin, has enabled it to be used in RBFDP treatments. Since PEEK is lighter than metal alloys, patients experience less discomfort and a feeling closer to natural teeth. Furthermore, the thermoplastic properties of PEEK are claimed to provide a precise fit, allowing the restoration to better integrate into the natural tooth structure. In addition, its ability to be customized using different modern manufacturing techniques is thought to offer dentists and patients a reliable option for successful long-term treatment. Our review is about the use of PEEK material as an alternative material in RBFDPs with low negative effects on periodontal tissues and their bonding with resins.
- 31 July 2024
- Published by Zeus Publishing in Journal of Medical and Dental Investigations
- Vol. 5, e240325
Open AccessClinical applications and improvement of resin bonding for PEEK in resin-bonded fixed dental prosthesis: A review
Resin-bonded fixed dental prostheses (RBFDPs) are a commonly used precision treatment, such as fixed dental prosthesis (FDP) and implant-supported dentures. Full crown preparation of vital teeth, which is required for traditional FDPs, may result in a risk of pulp reaction as a large portion of the coronal tooth structure must be removed. RBFDP has been recognized as a non-invasive or minimally invasive treatment modality for the replacement of single missing teeth. RBFDPs require much less tooth preparation than conventional FDPs. These dental treatments are restorative solutions used to cover missing teeth and achieve an aesthetic smile. The biomechanical rules, aesthetics, polishability, and bond strength have been emphasized in RBFDP treatments. Polyetheretherketone (PEEK) is one of the most widely used biomaterials in dentistry. The material, which stands out especially with its acceptable aesthetics, biocompatibility and modulus of elasticity close to dentin, has enabled it to be used in RBFDP treatments. Since PEEK is lighter than metal alloys, patients experience less discomfort and a feeling closer to natural teeth. Furthermore, the thermoplastic properties of PEEK are claimed to provide a precise fit, allowing the restoration to better integrate into the natural tooth structure. In addition, its ability to be customized using different modern manufacturing techniques is thought to offer dentists and patients a reliable option for successful long-term treatment. Our review is about the use of PEEK material as an alternative material in RBFDPs with low negative effects on periodontal tissues and their bonding with resins.
- Open Access
- 29 September 2023
- Published by Cumhuriyet University in Cumhuriyet Dental Journal
- Vol. 26 (3) , 310-320
The Effect of Food-Simulating Liquids and Thermal Aging on Surface Roughness and Color Stability of Bulk-Fill and Conventional Composites
Objectives: The aim of this study was to evaluate the effect of food-simulating liquids (FSLs) and thermal aging on the surface roughness and color stability of bulk-fill and conventional composites. Materials and Methods: A total of 320 disc-shaped samples were prepared, with 40 samples from each of 4 different bulk-fill composites (Filtek Bulk Fill, X-tra fil, Beautifil Bulk Restorative, and Estelite Bulk Fill Flow), and 4 conventional nano-filled composite resins (Filtek Z550, CeramX SphereTEC one, Admira, and Kalore). The prepared samples were randomly divided into subgroups for exposure to FSLs (ethanol, heptane, citric acid) and thermal cycling (TC) (n=10 per subgroup) for 28 days. Initial profilometric surface roughness measurements (Ra0) of all samples and AFM and SEM analyses of selected samples were followed by exposure to FSLs and TC. After completion of aging protocols, measurements and analyses were repeated to obtain the Ra1 (post-treatment surface roughness), and change in surface roughness (∆Ra1-0) was then calculated. Subsequently, initial color measurement of the samples was conducted using a spectrophotometer, followed by immersion of the samples in a coffee solution for 24 hours. Color measurements were repeated, and color change (∆E) was calculated. Two-way repeated measures ANOVA was used to compare Ra0 and Ra1 values and one-way ANOVA for comparing ∆Ra and ∆E values. Tukey and post hoc tests were employed for pairwise comparisons. The significance level was set at α=.05. Results: While the surface roughness of bulk-fill composites was affected by the protocols applied (p<0.05), conventional composites generally remained unaffected. Bulk-fill composites exhibited greater ΔRa and ∆E values. The highest ∆Ra and ∆E values were observed in the Beautifil Bulk Restorative group, with the greatest discoloration seen after immersion in citric acid. Conclusions: Thermal cycling and immersion in FSLs affect surface roughness and color stability of composite resins depending on the content and structure of the composites.
- 29 September 2023
- Published by Cumhuriyet University in Cumhuriyet Dental Journal
- Vol. 26 (3) , 310-320
Open AccessThe Effect of Food-Simulating Liquids and Thermal Aging on Surface Roughness and Color Stability of Bulk-Fill and Conventional Composites
Objectives: The aim of this study was to evaluate the effect of food-simulating liquids (FSLs) and thermal aging on the surface roughness and color stability of bulk-fill and conventional composites. Materials and Methods: A total of 320 disc-shaped samples were prepared, with 40 samples from each of 4 different bulk-fill composites (Filtek Bulk Fill, X-tra fil, Beautifil Bulk Restorative, and Estelite Bulk Fill Flow), and 4 conventional nano-filled composite resins (Filtek Z550, CeramX SphereTEC one, Admira, and Kalore). The prepared samples were randomly divided into subgroups for exposure to FSLs (ethanol, heptane, citric acid) and thermal cycling (TC) (n=10 per subgroup) for 28 days. Initial profilometric surface roughness measurements (Ra0) of all samples and AFM and SEM analyses of selected samples were followed by exposure to FSLs and TC. After completion of aging protocols, measurements and analyses were repeated to obtain the Ra1 (post-treatment surface roughness), and change in surface roughness (∆Ra1-0) was then calculated. Subsequently, initial color measurement of the samples was conducted using a spectrophotometer, followed by immersion of the samples in a coffee solution for 24 hours. Color measurements were repeated, and color change (∆E) was calculated. Two-way repeated measures ANOVA was used to compare Ra0 and Ra1 values and one-way ANOVA for comparing ∆Ra and ∆E values. Tukey and post hoc tests were employed for pairwise comparisons. The significance level was set at α=.05. Results: While the surface roughness of bulk-fill composites was affected by the protocols applied (p<0.05), conventional composites generally remained unaffected. Bulk-fill composites exhibited greater ΔRa and ∆E values. The highest ∆Ra and ∆E values were observed in the Beautifil Bulk Restorative group, with the greatest discoloration seen after immersion in citric acid. Conclusions: Thermal cycling and immersion in FSLs affect surface roughness and color stability of composite resins depending on the content and structure of the composites.
- 14 April 2021
- Published by Wiley in Microscopy Research and Technique
- Vol. 84 (10) , 2206-2218
Effects of different remineralizing agents on color stability and surface characteristics of the teeth following vital bleaching
The aim of the study was to investigate the effects of various remineralizing agents on the color stability and surface characteristics of the teeth after vital bleaching. The extracted 96 human incisors were used for the study. Initially, the samples were randomly divided into two groups and exposed to in‐office and at‐home bleaching agents. Then, the groups were divided into six subgroups (n = 8), including the control group did not undergo remineralization after bleaching, according to five remineralizing agents (Gelato APF Gel, Remin Pro, Tooth Mousse, MI Paste Plus, Curodont Protect). Surface roughness was assessed at baseline, after bleaching and remineralization procedures. Color measurements of the samples were obtained at baseline, after bleaching and then after immersion in the staining solution following remineralization process. Scanning electron microscopy and atomic force microscopy (AFM) analyzes were carried out in order to examine the morphological changes on the surface of the enamel. The independent t‐test, paired‐samples t‐test, and one‐way ANOVA was used to compare the data and post‐hoc LSD test to compare the difference among the study groups (α = .05). Surface roughness increased following in‐office and at‐home bleaching in all groups, and reduced after application of remineralizing agents in all groups. Significant differences were found among the groups with respect to changes in surface roughness and color values following treatment with remineralizing agents (p <.05). AFM analyses revealed increased surface roughness after bleaching and a reduction of rough surfaces following treatment with remineralizing agents. Remineralizing agents can be used to reduce postbleaching increase in surface roughness and to maintain color stability after bleaching.
- 14 April 2021
- Published by Wiley in Microscopy Research and Technique
- Vol. 84 (10) , 2206-2218
Effects of different remineralizing agents on color stability and surface characteristics of the teeth following vital bleaching
The aim of the study was to investigate the effects of various remineralizing agents on the color stability and surface characteristics of the teeth after vital bleaching. The extracted 96 human incisors were used for the study. Initially, the samples were randomly divided into two groups and exposed to in‐office and at‐home bleaching agents. Then, the groups were divided into six subgroups (n = 8), including the control group did not undergo remineralization after bleaching, according to five remineralizing agents (Gelato APF Gel, Remin Pro, Tooth Mousse, MI Paste Plus, Curodont Protect). Surface roughness was assessed at baseline, after bleaching and remineralization procedures. Color measurements of the samples were obtained at baseline, after bleaching and then after immersion in the staining solution following remineralization process. Scanning electron microscopy and atomic force microscopy (AFM) analyzes were carried out in order to examine the morphological changes on the surface of the enamel. The independent t‐test, paired‐samples t‐test, and one‐way ANOVA was used to compare the data and post‐hoc LSD test to compare the difference among the study groups (α = .05). Surface roughness increased following in‐office and at‐home bleaching in all groups, and reduced after application of remineralizing agents in all groups. Significant differences were found among the groups with respect to changes in surface roughness and color values following treatment with remineralizing agents (p <.05). AFM analyses revealed increased surface roughness after bleaching and a reduction of rough surfaces following treatment with remineralizing agents. Remineralizing agents can be used to reduce postbleaching increase in surface roughness and to maintain color stability after bleaching.
- 26 March 2021
- Published by Wiley in Microscopy Research and Technique
- Vol. 84 (9) , 2058-2067
Effect of different polishing systems on the surface roughness of various bulk‐fill and nano‐filled resin‐based composites: An atomic force microscopy and scanning electron microscopy study
The aim of the study was to evaluate the effects of different polishing systems on the surface roughness of various bulk‐fill and nano‐filled resin‐based composites using different methods. For the study, a total of 192 disc‐shaped samples (10‐mm wide and 2‐mm thick) were prepared from four different bulk‐fill composites (Filtek Bulk Fill, X‐tra fil, Beautifil‐Bulk Restorative and Fill Up) and two nano‐filled resin‐based composites (Ceram.x SphereTEC and Filtek Z550). The samples in each composite group were divided into four subgroups according to the polishing system to be used (n = 8). Four different polishing systems (Sof‐Lex Diamond, Clearfil Twist Dia, HiLuster Plus, OptiDisc) were applied. Then, surface roughness measurements were carried out using a contact‐type profilometer. One sample from each group was subjected to atomic force microscopy (AFM) and scanning electron microscope (SEM) examinations. Surface roughness (Ra) values were statistically analyzed in terms of composites and polishing systems using the two‐way analysis of variance (ANOVA) and comparisons among groups were performed using the Tukey test (α = .05). Surface roughness values differed significantly in relation to the composite and polishing system used (p < .05). Among all composites, the lowest surface roughness values were obtained in the groups treated with the OptiDisc polishing system (except Beautifil‐Bulk Restorative), whereas the highest roughness values were observed in the group polished with Clearfil Twist Dia (except Filtek Z550). X‐tra fil showed the highest roughness value with all polishing systems tested. The findings of AFM analyses were consistent with profilometric measurements. The nano‐filled resin‐based composites showed smoother surface than bulk‐fill composites and the type of the polishing systems was found to affect surface roughness.
- 26 March 2021
- Published by Wiley in Microscopy Research and Technique
- Vol. 84 (9) , 2058-2067
Effect of different polishing systems on the surface roughness of various bulk‐fill and nano‐filled resin‐based composites: An atomic force microscopy and scanning electron microscopy study
The aim of the study was to evaluate the effects of different polishing systems on the surface roughness of various bulk‐fill and nano‐filled resin‐based composites using different methods. For the study, a total of 192 disc‐shaped samples (10‐mm wide and 2‐mm thick) were prepared from four different bulk‐fill composites (Filtek Bulk Fill, X‐tra fil, Beautifil‐Bulk Restorative and Fill Up) and two nano‐filled resin‐based composites (Ceram.x SphereTEC and Filtek Z550). The samples in each composite group were divided into four subgroups according to the polishing system to be used (n = 8). Four different polishing systems (Sof‐Lex Diamond, Clearfil Twist Dia, HiLuster Plus, OptiDisc) were applied. Then, surface roughness measurements were carried out using a contact‐type profilometer. One sample from each group was subjected to atomic force microscopy (AFM) and scanning electron microscope (SEM) examinations. Surface roughness (Ra) values were statistically analyzed in terms of composites and polishing systems using the two‐way analysis of variance (ANOVA) and comparisons among groups were performed using the Tukey test (α = .05). Surface roughness values differed significantly in relation to the composite and polishing system used (p < .05). Among all composites, the lowest surface roughness values were obtained in the groups treated with the OptiDisc polishing system (except Beautifil‐Bulk Restorative), whereas the highest roughness values were observed in the group polished with Clearfil Twist Dia (except Filtek Z550). X‐tra fil showed the highest roughness value with all polishing systems tested. The findings of AFM analyses were consistent with profilometric measurements. The nano‐filled resin‐based composites showed smoother surface than bulk‐fill composites and the type of the polishing systems was found to affect surface roughness.