Roshan S. Livingstone
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Roshan S. Livingstone has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Alok Srivastava
Haematology Research Unit, St. John's Research Institute and St. John's Medical College Hospital Bengaluru India
1 shared publication - Madhavi Kandagaddala
Department of Radiology, Christian Medical College, Vellore, India
1 shared publication - Pradeep Mathew Poonnoose
Department of Orthopaedic Surgery Christian Medical College Vellore Tamil Nadu India
1 shared publication S Keshava
Christian Medical College Vellore Tamil Nadu
1 shared publication- Shyamkumar Nidugala Keshava
Department of Radiodiagnosis, Division of Clinical Radiology, Christian Medical College, Vellore, Tamil Nadu, India
1 shared publication - Soumya Susan Regi
Christian Med Coll & Hosp, Dept Radiodiag, Vellore, India
1 shared publication
Latest Publications
- 29 March 2021
- Published by Wiley in Haemophilia
- Vol. 27 (3) , 488-493
Ultrasound and magnetic resonance imaging for the detection of blood: An ex‐vivo study
Objectives: Early detection of bleeding into a joint is crucial in patients with haemophilia. This study was designed to evaluate the sensitivity of ultrasonography (USG) and magnetic resonance imaging (MRI) to detect the presence of blood in small concentrations in a simulated model to mimic joint bleeding.Materials and Methods: Different concentrations of blood in plasma, varying from 0.1% to 45%, were collected in 10‐ml plastic syringes and imaged using 12 and 18 MHz USG transducers and with 1.5T and 3T MRI scanners, at different intervals of time following dilution. The images were scored for the presence of blood by four experienced radiologists who were blinded to the concentration of blood.Results: Within the first 2 h, the 18 MHz transducer was able to detect blood consistently up to 0.5%, whereas the 12 MHz transducer could consistently identify blood up to 1.4%. After the first 12 h, both transducers were able to detect blood up to 0.5% concentration. However, at concentrations below 0.5%, there was discordance in the ability to detect blood, with both transducers. There was no correlation between the signal intensities of MRI images and concentration of blood, at different time intervals, irrespective of the magnetic field strength.Conclusions: Detection of blood using the USG is dependent on variables such as the concentration of blood, frequency of the transducer used and timing of the imaging. As the concentration of blood decreases below 0.5%, the discordance between the observers increases, implying that the detection limit of USG affects its reliability at lower concentrations of blood. Caution is urged while interpreting USG imaging studies for the detection of blood in symptomatic joints.
- 29 March 2021
- Published by Wiley in Haemophilia
- Vol. 27 (3) , 488-493
Ultrasound and magnetic resonance imaging for the detection of blood: An ex‐vivo study
Objectives: Early detection of bleeding into a joint is crucial in patients with haemophilia. This study was designed to evaluate the sensitivity of ultrasonography (USG) and magnetic resonance imaging (MRI) to detect the presence of blood in small concentrations in a simulated model to mimic joint bleeding.Materials and Methods: Different concentrations of blood in plasma, varying from 0.1% to 45%, were collected in 10‐ml plastic syringes and imaged using 12 and 18 MHz USG transducers and with 1.5T and 3T MRI scanners, at different intervals of time following dilution. The images were scored for the presence of blood by four experienced radiologists who were blinded to the concentration of blood.Results: Within the first 2 h, the 18 MHz transducer was able to detect blood consistently up to 0.5%, whereas the 12 MHz transducer could consistently identify blood up to 1.4%. After the first 12 h, both transducers were able to detect blood up to 0.5% concentration. However, at concentrations below 0.5%, there was discordance in the ability to detect blood, with both transducers. There was no correlation between the signal intensities of MRI images and concentration of blood, at different time intervals, irrespective of the magnetic field strength.Conclusions: Detection of blood using the USG is dependent on variables such as the concentration of blood, frequency of the transducer used and timing of the imaging. As the concentration of blood decreases below 0.5%, the discordance between the observers increases, implying that the detection limit of USG affects its reliability at lower concentrations of blood. Caution is urged while interpreting USG imaging studies for the detection of blood in symptomatic joints.
- 6 June 2013
- Published by Wiley in Medical Physics
- Vol. 40 (6Part5) , 132
SU-E-I-31: Moving From Image Intensifier to Flat Panel Detector in Interventional Radiology: Initial Experiences in a Tertiary Referral Center in India
- 6 June 2013
- Published by Wiley in Medical Physics
- Vol. 40 (6Part5) , 132
SU-E-I-31: Moving From Image Intensifier to Flat Panel Detector in Interventional Radiology: Initial Experiences in a Tertiary Referral Center in India