  • Open Access

    An In Vitro Investigation of Gas and Dye Leakage at the Implant–Abutment Junction Using Titanium and Cobalt Chrome-Based Abutments

    by Amylia Kesha Bal, Terry Richard Walton, Hedi Verena Kruse, Dale Geoffrey Howes

    The lack of integrity at the implant–abutment junction (IAJ) contributes to problems such as micromovements and microbial colonisation. This study aimed to (1) design a protocol for assessing microleakage at the IAJ using chromophore analysis not previously reported for this specific application, (2) compare gas and dye leakage between titanium (Ti) and cobalt chrome (CoCr) abutments, and (3) assess the effect of gold (Au) gilding on sealing. Forty abutments were divided into five groups: milled Ti (MTi); cast CoCr (CCoCr); milled CoCr (MCoCr); cast CoCr with Au gilding (CCoCrG); and milled CoCr with Au gilding (MCoCrG). Samples were subjected to internal pressure within a gas and dye reservoir. Chromophore analysis via UV-Vis spectrometer was used to calculate crystal violet leakage concentrations. Scanning electron microscopy (SEM) revealed close adaptation in the MTi and MCoCr groups, contrasting with irregularities in the CCoCr groups. Correspondingly, gas leakage and dye leakage were most prevalent in the CCoCr group. Fisher exact test demonstrated a statistically significant difference (p = 0.026) between the MCoCr and CCoCr abutments. While CCoCr exhibited the highest failure rate (62.5%), Au gilding demonstrated a trend toward reduced leakage (25% failure rate), though this did not reach statistical significance (p = 0.315). This chromophore analysis represents a viable and objective assessment of IAJ integrity.

  • Open Access

    An In Vitro Investigation of Gas and Dye Leakage at the Implant-Abutment Junction Using Titanium and Cobalt Chrome-Based Abutments

    by Amylia Bal, Terry Walton, Hedi Verena Kruse, Dale Howes

    The lack of integrity at the implant-abutment junction (IAJ) contributes to problems such as micromovements and microbial colonization. This study aimed to (1) design a protocol for assessing microleakage at the IAJ using chromophore analysis that hasn’t been involved in other analysis, (2) compare gas and dye leakage using titanium (Ti) and cobalt chrome (CoCr) abutments, and (3) assess the effect of gold (Au) gilding on sealing. Forty abutments were divided into five groups: milled Ti (MTi); cast CoCr (CCoCr); milled CoCr (MCoCr); cast CoCr with Au gilding (CCoCrG); and milled CoCr with Au gilding (MCoCrG). Samples were connected to a pressurised gas and dye reservoir. Chromophore analysis using crystal violet was performed via UV-Vis spec-trometer to calculate leakage concentration. Scanning electron microscopy (SEM) analysis assessed surface morphology which revealed an intimate contact with the MTi and MCoCr but irregularities at the CCoCr abutments. Results showed gas leakage in CCoCr and MCoCr groups, while no true dye leakage occurred in MTi, MCoCr and MCoCrG assemblies. CCoCr exhibited the poorest seal; however, Au gilding improved the seal in these samples. Chromophore analysis using crystal violet provided an ac-curate quantitative assessment. Milled abutments demonstrated significantly less mi-croleakage than cast (non-gilded) versions, Au gilding effectively reduced leakage.

  • Open Access

    Effect of Electrodeposited Gold Coatings on Micro-Gaps, Surface Profile and Bacterial Leakage of Cast UCLA Abutments Attached to External Hexagon Dental Implants

    by Terry R. Walton

    Purpose: The objective of the study was to qualitatively assess the micro-gap dimensions, connecting fitting surface profile, and bacterial leakage of cast high-gold-alloy UCLA abutments, with or without electrodeposited gold coatings attached to external hexagon implants. Materials and methods: Sixteen plastic UCLAs (PUCLAs) were cast with a high-gold-content alloy. Eight were electrolytically gold plated. Five machined cast-to-UCLA (GUCLA) control abutments were cast with the same alloy. All abutments were attached to external hexagon implants, giving 21 implant-abutment combinations (IACs). External perimeter micro-gaps measured with SEM under shadow eliminating silhouette illumination and 2000× magnification were averaged over three regions. The IACs were examined for E. coli leakage following an initial sterility test. Disassembled combinations were examined with SEM, and surface profiles were qualitatively assessed. Results: External micro-gap measurements did not reflect the variable connecting surface profiles, but average values < 5.0 μm were observed for all IACs measured under the shadow eliminating silhouette illumination for both cast and pre-machined external hexagon abutments with and without Au plating. E. coli transfer was observed in 3 of 5 PUCLA-plated and 2 of 5 PUCLA-non-plated IACs. No transfer occurred in the 3 GUCLA-non-plated or 2 GUCLA-plated control IACs. Abutment connecting surfaces, both Au-plated and not Au-plated, showed plastic deformation (smearing) in variable mosaic patterns across the micro-gap. Conclusions: Micro-gap dimensions < 5μm were obtained with both the high noble metal cast and pre-machined control external hexagon abutments with and without Au electrodeposited on the abutment connecting surface. Regions of intimate contact due to plastic deformation (smearing) of these surfaces were observed. A continuous smeared region around the circumference of the surfaces can provide an effective barrier to the egress of E. coli bacteria from the internal regions of the implant under static loading. The sample size was insufficient to determine if the gold coating resulted in a superior bacterial barrier.


  • Open Access

    Effect of Electrodeposited Gold Coatings on Micro-Gaps, Surface Profile and Bacterial Leakage of UCLA Abutments Attached to External Hexagon Dental Implants

    by Terry R Walton

    Purpose: The objective of the study was to qualitatively assess micro-gap dimensions, connecting fitting surface profile and bacterial leakage of machined and cast high gold alloy UCLA abutments, with or without electrodeposited gold coatings attached to external hexagon implants. Materials and methods: 16 plastic UCLA (PUCLA) and 5 machined cast-to UCLA (GUCLA) abutments were cast with a high gold content alloy. 10 were electrolytically gold plated (8 - PUCLA, 2 - GUCLA). All abutments were attached to implants giving 21 implant-abutment combinations (IACs). External perimeter micro-gaps measured with SEM under different illumination and magnification conditions were averaged over three regions. The IACs were examined for E.coli leakage following an initial sterility test. Disassembled combinations were examined with SEM and surface profiles qualitatively assessed. Results: External micro-gap measurements did not reflect the variable connecting surface profiles but average values < 3.5 μm were observed for all IACs. Bacterial transfer was observed in 3 of 5 PUCLA plated and 2 of 5 PUCLA non-plated IACs. No transfer occurred in the 3 GUCLA non-plated or 2 GUCLA plated IACs. Abutment connecting surfaces, both Au plated and not Au plated, showed plastic deformation (smearing) in variable mosaic patterns across the micro-gap. External micro-gap dimensions although not truly reflective of surface connecting profiles averaged < 3.5 μm measured under shadow eliminating silhouette illumination for both cast and pre-machined external hexagon abutments with and without Au plating. Conclusions: Micro-gap dimensions < 5 μm were obtained with both high noble metal cast and pre-machined external hexagon abutments with and without Au electrodeposited on the abutment connecting surface. Regions of intimate contact due to plastic deformation (smearing) of these surfaces was observed. A continuous smeared region around the circumference of the surfaces can provide an effective barrier to egress of E.coli bacteria from the internal regions of the implant under static loading.


  • Open Access

    Characterisation of Electroplated Gold Coatings for Dental Applications: Estimation of Thickness Using Non-Destructive Electron-Probe Microanalysis Related to Plating Time

    by Terry R Walton

    Objectives: This study aimed to measure non-destructively gold (Au) electrodeposited on a high-gold alloy by modulating coating time and comparing this to sputtering Au to known thicknesses. Methods: Au was electrodeposited (plated) on 11 high-gold alloy plates (A–K) at 2.8V between 20 and 220 min. Seven Au strips were sputter coated on the same alloy to known thicknesses (range 50–500 nm). Energy dispersive X-ray spectroscopy (EDS) was used to measure minimal electron energy (E0) required to penetrate Au coatings and generate x-ray signals of 1% atomic palladium (Pd) from the underlying alloy for test samples and Au strips. % Pd X-ray concentration at maximum 30 kV was also obtained. The obtained signal–thickness relationship of known Au strip thicknesses was used to calculate Au thickness on the A–K samples based on two analytical relations. Energy dispersive X-ray fluorescence spectroscopy (XRF) was used as a complementary method to ensure coating thickness estimations were accurate. Results: EDS values for all reference and unknown thicknesses were obtained and verified with XRF. Correlating these signals with the Data Analysis Software and matching with known plating times allowed estimation of Au thickness of the unknown samples (range 27–425 nm). Estimated thicknesses were shown to have a linear relationship with plating time except for samples C–D, where there was an inverted relationship. Significance: A non-destructive method for measuring electrodeposited thickness of Au on high-gold alloys related to plating time was developed and verified. There is a linear relationship to Au thickness and plating time between 20 and 220 min.


  • Mediotrusive Occlusal Contacts: Best Evidence Consensus Statement

    by Terry R Walton, Danielle M Layton

    Purpose: The impact of mediotrusive (MT) occlusal contacts has been a topic of controversy and confusion in both clinical practice and in the dental literature. The purpose of this Best Evidence Consensus Statement was to explore whether MT interferences are harmful in the natural or therapeutic occlusion directed by 4 focus questions relating to prevalence, jaw function, jaw dysfunction and biomechanical models.Materials and Methods: An electronic search in October 2020 sought evidence in MEDLINE (Ovid) using (mediotrus* OR nonworking side OR nonworking contact OR balancing side OR interfer* side OR premature contact) in the multipurpose (.mp) search field; and in Google Scholar using permutations of the above. Supplementary articles were sourced from the associated reference lists. There was no language restriction. The search yield was reviewed in duplicate.Results: The electronic search identified 420 articles. Following screening, 164 were selected for eligibility assessments. Of these, 47 were included in the current paper.Conclusions: Non‐standardized nomenclature and methodology is used to identify MT interferences in patient populations, with resultant prevalence varying from 0% to 77%, (median = 16%). MT interferences may alter the biomechanics of mandibular function. Together with the presence of repeated high loads resultant strain can manifest as pathophysiology of the temporomandibular joint and associated muscle structures. MT interferences should be avoided in any therapeutic occlusal scheme to minimize pulpal, periodontal, structural and mechanical complications or exacerbation of temporomandibular disorders (TMDs). Naturally occurring molar MT interferences should be eliminated only if signs and symptoms of TMDs are present. Literature supports there being a biomechanical basis which can explain how MT interferences may affect temporomandibular joint morphology and jaw function.