Amylia Kesha Bal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Amylia Kesha Bal has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Dale Howes
Department of Oral Rehabilitation, Division of Prosthodontics, Sydney Dental School, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW 2000, Australia
2 shared publications - Hedi Verena Kruse
Department of Oral Rehabilitation, Division of Prosthodontics, Sydney Dental School, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW 2000, Australia
2 shared publications - Terry Richard Walton
Department of Oral Rehabilitation, Division of Prosthodontics, Sydney Dental School, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW 2000, Australia
2 shared publications
Latest Publications
- Open Access
An In Vitro Investigation of Gas and Dye Leakage at the Implant–Abutment Junction Using Titanium and Cobalt Chrome-Based Abutments
The lack of integrity at the implant–abutment junction (IAJ) contributes to problems such as micromovements and microbial colonisation. This study aimed to (1) design a protocol for assessing microleakage at the IAJ using chromophore analysis not previously reported for this specific application, (2) compare gas and dye leakage between titanium (Ti) and cobalt chrome (CoCr) abutments, and (3) assess the effect of gold (Au) gilding on sealing. Forty abutments were divided into five groups: milled Ti (MTi); cast CoCr (CCoCr); milled CoCr (MCoCr); cast CoCr with Au gilding (CCoCrG); and milled CoCr with Au gilding (MCoCrG). Samples were subjected to internal pressure within a gas and dye reservoir. Chromophore analysis via UV-Vis spectrometer was used to calculate crystal violet leakage concentrations. Scanning electron microscopy (SEM) revealed close adaptation in the MTi and MCoCr groups, contrasting with irregularities in the CCoCr groups. Correspondingly, gas leakage and dye leakage were most prevalent in the CCoCr group. Fisher exact test demonstrated a statistically significant difference (p = 0.026) between the MCoCr and CCoCr abutments. While CCoCr exhibited the highest failure rate (62.5%), Au gilding demonstrated a trend toward reduced leakage (25% failure rate), though this did not reach statistical significance (p = 0.315). This chromophore analysis represents a viable and objective assessment of IAJ integrity.
Open AccessAn In Vitro Investigation of Gas and Dye Leakage at the Implant–Abutment Junction Using Titanium and Cobalt Chrome-Based Abutments
The lack of integrity at the implant–abutment junction (IAJ) contributes to problems such as micromovements and microbial colonisation. This study aimed to (1) design a protocol for assessing microleakage at the IAJ using chromophore analysis not previously reported for this specific application, (2) compare gas and dye leakage between titanium (Ti) and cobalt chrome (CoCr) abutments, and (3) assess the effect of gold (Au) gilding on sealing. Forty abutments were divided into five groups: milled Ti (MTi); cast CoCr (CCoCr); milled CoCr (MCoCr); cast CoCr with Au gilding (CCoCrG); and milled CoCr with Au gilding (MCoCrG). Samples were subjected to internal pressure within a gas and dye reservoir. Chromophore analysis via UV-Vis spectrometer was used to calculate crystal violet leakage concentrations. Scanning electron microscopy (SEM) revealed close adaptation in the MTi and MCoCr groups, contrasting with irregularities in the CCoCr groups. Correspondingly, gas leakage and dye leakage were most prevalent in the CCoCr group. Fisher exact test demonstrated a statistically significant difference (p = 0.026) between the MCoCr and CCoCr abutments. While CCoCr exhibited the highest failure rate (62.5%), Au gilding demonstrated a trend toward reduced leakage (25% failure rate), though this did not reach statistical significance (p = 0.315). This chromophore analysis represents a viable and objective assessment of IAJ integrity.
- Open Access
- 10 February 2026
- Published by MDPI AG in Preprints.org
An In Vitro Investigation of Gas and Dye Leakage at the Implant-Abutment Junction Using Titanium and Cobalt Chrome-Based Abutments
The lack of integrity at the implant-abutment junction (IAJ) contributes to problems such as micromovements and microbial colonization. This study aimed to (1) design a protocol for assessing microleakage at the IAJ using chromophore analysis that hasn’t been involved in other analysis, (2) compare gas and dye leakage using titanium (Ti) and cobalt chrome (CoCr) abutments, and (3) assess the effect of gold (Au) gilding on sealing. Forty abutments were divided into five groups: milled Ti (MTi); cast CoCr (CCoCr); milled CoCr (MCoCr); cast CoCr with Au gilding (CCoCrG); and milled CoCr with Au gilding (MCoCrG). Samples were connected to a pressurised gas and dye reservoir. Chromophore analysis using crystal violet was performed via UV-Vis spec-trometer to calculate leakage concentration. Scanning electron microscopy (SEM) analysis assessed surface morphology which revealed an intimate contact with the MTi and MCoCr but irregularities at the CCoCr abutments. Results showed gas leakage in CCoCr and MCoCr groups, while no true dye leakage occurred in MTi, MCoCr and MCoCrG assemblies. CCoCr exhibited the poorest seal; however, Au gilding improved the seal in these samples. Chromophore analysis using crystal violet provided an ac-curate quantitative assessment. Milled abutments demonstrated significantly less mi-croleakage than cast (non-gilded) versions, Au gilding effectively reduced leakage.
- 10 February 2026
- Published by MDPI AG in Preprints.org
Open AccessAn In Vitro Investigation of Gas and Dye Leakage at the Implant-Abutment Junction Using Titanium and Cobalt Chrome-Based Abutments
The lack of integrity at the implant-abutment junction (IAJ) contributes to problems such as micromovements and microbial colonization. This study aimed to (1) design a protocol for assessing microleakage at the IAJ using chromophore analysis that hasn’t been involved in other analysis, (2) compare gas and dye leakage using titanium (Ti) and cobalt chrome (CoCr) abutments, and (3) assess the effect of gold (Au) gilding on sealing. Forty abutments were divided into five groups: milled Ti (MTi); cast CoCr (CCoCr); milled CoCr (MCoCr); cast CoCr with Au gilding (CCoCrG); and milled CoCr with Au gilding (MCoCrG). Samples were connected to a pressurised gas and dye reservoir. Chromophore analysis using crystal violet was performed via UV-Vis spec-trometer to calculate leakage concentration. Scanning electron microscopy (SEM) analysis assessed surface morphology which revealed an intimate contact with the MTi and MCoCr but irregularities at the CCoCr abutments. Results showed gas leakage in CCoCr and MCoCr groups, while no true dye leakage occurred in MTi, MCoCr and MCoCrG assemblies. CCoCr exhibited the poorest seal; however, Au gilding improved the seal in these samples. Chromophore analysis using crystal violet provided an ac-curate quantitative assessment. Milled abutments demonstrated significantly less mi-croleakage than cast (non-gilded) versions, Au gilding effectively reduced leakage.