William Monteleone
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
William Monteleone has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Fabian Ochs
University of Innsbruck
11 shared publications - Georgios Dermentzis
University of Innsbruck
5 shared publications - Elisa Venturi
University of Innsbruck
2 shared publications Fabian Ochs
University of Innsbruck
2 shared publicationsMarco Romani
2 shared publications- Paolo Emilio Santangelo
Univ Modena & Reggio Emilia, Dipartimento Sci & Metodi Ingn, Reggio Emilia, Italy
2 shared publications
Latest Publications
- 14 November 2026
- Published by Elsevier in Energy and Buildings
Comprehensive modelling of exhaust air heat pumps for residential applications under cooling operation
- 14 November 2026
- Published by Elsevier in Energy and Buildings
Comprehensive modelling of exhaust air heat pumps for residential applications under cooling operation
- Open Access
- 1 September 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3302 (1)
Mould risk evaluation through testing and hygrothermal simulations of façade-integrated split heat pumps
To achieve a fully decarbonized building stock in the European Union by 2050, renovation rates must significantly increase. In dense urban areas, multi-family buildings require efficient and cost-effective solutions to improve building envelope performance and replace outdated fossil-fuel boilers used for space heating (SH) and domestic hot water (DHW) with minimal disruption. Heat pumps (HPs) are a promising alternative, but their adoption in renovated multi-family buildings is often limited by restricted access to heat sources, noise, and disruptive installation processes. Façade integration represents a promising solution, enabling prefabrication that reduces costs and construction time while allowing the installation of silent air-source HPs with minimal disturbance to existing apartments. At the University of Innsbruck (UIBK), a silent mini-split air-to-water HP for decentralized DHW preparation was developed and tested. The system includes a façade-integrated outdoor unit with a compact evaporator and four axial fans, while the indoor unit houses the compressor, condenser, expansion valve, and a hot water storage tank. Because façade-integrated HPs interact with the building envelope, thermo-hygrometric analyses are required to prevent low temperatures that could lead to condensation, mould growth, and long-term damage. Simulations in DELPHIN over five years show that sufficient insulation is needed around the outdoor unit to avoid thermal bridges; installing a 5 cm aerogel panel behind the unit prevents condensation.
- 1 September 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3302 (1)
Open AccessMould risk evaluation through testing and hygrothermal simulations of façade-integrated split heat pumps
To achieve a fully decarbonized building stock in the European Union by 2050, renovation rates must significantly increase. In dense urban areas, multi-family buildings require efficient and cost-effective solutions to improve building envelope performance and replace outdated fossil-fuel boilers used for space heating (SH) and domestic hot water (DHW) with minimal disruption. Heat pumps (HPs) are a promising alternative, but their adoption in renovated multi-family buildings is often limited by restricted access to heat sources, noise, and disruptive installation processes. Façade integration represents a promising solution, enabling prefabrication that reduces costs and construction time while allowing the installation of silent air-source HPs with minimal disturbance to existing apartments. At the University of Innsbruck (UIBK), a silent mini-split air-to-water HP for decentralized DHW preparation was developed and tested. The system includes a façade-integrated outdoor unit with a compact evaporator and four axial fans, while the indoor unit houses the compressor, condenser, expansion valve, and a hot water storage tank. Because façade-integrated HPs interact with the building envelope, thermo-hygrometric analyses are required to prevent low temperatures that could lead to condensation, mould growth, and long-term damage. Simulations in DELPHIN over five years show that sufficient insulation is needed around the outdoor unit to avoid thermal bridges; installing a 5 cm aerogel panel behind the unit prevents condensation.
- Open Access
- 3 August 2026
- Published by Elsevier in SSRN Electronic Journal
Comprehensive modeling and experimental analysis of exhaust air heat pumps for residential applications under cooling operation
Decarbonization of the building sector calls for more efficient heating, cooling, and ventilation solutions. Exhaust air heat pumps, which combine heat or enthalpy recovery and exhaust-to-supply air heat pump operation, offer a promising approach for low-energy buildings, but their performance depends on complex interactions and accurate prediction requires advanced numerical modeling and experimental validation. In this study, a high-fidelity digital model of an exhaust air heat pump is presented and validated under cooling operation through a dedicated experimental campaign. The model integrates detailed physics-based representations of all major components and of the onboard control logic, enabling accurate prediction of unit behavior. A comparison of the simulation results with experimental measurements across the full cooling operating range, including both full- and partial-load conditions, showed that overall performance indicators were predicted within ±10% across all tested conditions. The validated model was subsequently employed to explore operating scenarios and control strategies beyond the experimental campaign that still require investigation. Specifically, the analysis assessed the impact, on overall system-level performance, of the integration of an auxiliary outdoor-to-exhaust fan, the heat recovery strategy and the heat recovery bypass fraction, in on-design and off-design conditions. The analysis revealed the need to pursue a trade-off between maximizing system energy efficiency and ensuring the fulfillment of the required cooling capacity, highlighting how design and control choices can substantially influence overall system performance. These findings demonstrate the potential of digital models to advance the understanding, optimization, and operation of next-generation Heating, Ventilation and Air Conditioning systems in low-energy buildings.
- 3 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessComprehensive modeling and experimental analysis of exhaust air heat pumps for residential applications under cooling operation
Decarbonization of the building sector calls for more efficient heating, cooling, and ventilation solutions. Exhaust air heat pumps, which combine heat or enthalpy recovery and exhaust-to-supply air heat pump operation, offer a promising approach for low-energy buildings, but their performance depends on complex interactions and accurate prediction requires advanced numerical modeling and experimental validation. In this study, a high-fidelity digital model of an exhaust air heat pump is presented and validated under cooling operation through a dedicated experimental campaign. The model integrates detailed physics-based representations of all major components and of the onboard control logic, enabling accurate prediction of unit behavior. A comparison of the simulation results with experimental measurements across the full cooling operating range, including both full- and partial-load conditions, showed that overall performance indicators were predicted within ±10% across all tested conditions. The validated model was subsequently employed to explore operating scenarios and control strategies beyond the experimental campaign that still require investigation. Specifically, the analysis assessed the impact, on overall system-level performance, of the integration of an auxiliary outdoor-to-exhaust fan, the heat recovery strategy and the heat recovery bypass fraction, in on-design and off-design conditions. The analysis revealed the need to pursue a trade-off between maximizing system energy efficiency and ensuring the fulfillment of the required cooling capacity, highlighting how design and control choices can substantially influence overall system performance. These findings demonstrate the potential of digital models to advance the understanding, optimization, and operation of next-generation Heating, Ventilation and Air Conditioning systems in low-energy buildings.
- Open Access
- 24 April 2026
- Published by Elsevier in SSRN Electronic Journal
Thermal characterisation of insulation materials for large-scale thermal energy storage systems
Large-scale thermal energy storage (TES) will gain importance with the transition to renewable energy-based district heating. Their performance depends on the quality of the insulation of the cover as well as the walls. Hence, evaluating the performance of insulating materials applied to the vertical walls under realistic boundary conditions is important. High temperatures (ca. 90 °C) and high temperature gradients can have significant impact on the thermal characteristics of the insulation. In particular, if natural convection occurs, this significantly affects the effective thermal conductivity of porous insulation materials; hence methods to assess the risk of its development and solutions on how to prevent it are required. Starting with an initial selection of suitable materials from existing TES projects, their apparent thermal conductivity is determined using standard laboratory tests, lab-scale mock-ups and real-scale mock-ups. Both, analytical (i.e., Rayleigh number) and numerical methods are applied to evaluate the apparent thermal conductivity and to predict the presence of convection and the evaluate its influence. Experimental mock-ups are used to assess the material performance in real TES operation conditions.This study considers bulk insulation materials such as foam glass gravel (FGG) and expanded glass gravel (EGG), as well as sheets of fibrous materials such as rock wool (RW), and rigid materials like foam glass (FG) and lightweight concrete. The Rayleigh number is used to rank the materials according to their risk of convection development, when used as lateral TES insulation. Experimental mock-ups show good agreement with the laboratory measurements, proving that reducing the open porosity of FGG by mixing it with a material with smaller grains like EGG is promising for lowering convection risk. Nevertheless, insulation material selection and installation procedure is important to ensure homogeneous distribution and avoid material segregation or internal bulking that would lead to inhomogeneous insulation distribution.
- 24 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThermal characterisation of insulation materials for large-scale thermal energy storage systems
Large-scale thermal energy storage (TES) will gain importance with the transition to renewable energy-based district heating. Their performance depends on the quality of the insulation of the cover as well as the walls. Hence, evaluating the performance of insulating materials applied to the vertical walls under realistic boundary conditions is important. High temperatures (ca. 90 °C) and high temperature gradients can have significant impact on the thermal characteristics of the insulation. In particular, if natural convection occurs, this significantly affects the effective thermal conductivity of porous insulation materials; hence methods to assess the risk of its development and solutions on how to prevent it are required. Starting with an initial selection of suitable materials from existing TES projects, their apparent thermal conductivity is determined using standard laboratory tests, lab-scale mock-ups and real-scale mock-ups. Both, analytical (i.e., Rayleigh number) and numerical methods are applied to evaluate the apparent thermal conductivity and to predict the presence of convection and the evaluate its influence. Experimental mock-ups are used to assess the material performance in real TES operation conditions.This study considers bulk insulation materials such as foam glass gravel (FGG) and expanded glass gravel (EGG), as well as sheets of fibrous materials such as rock wool (RW), and rigid materials like foam glass (FG) and lightweight concrete. The Rayleigh number is used to rank the materials according to their risk of convection development, when used as lateral TES insulation. Experimental mock-ups show good agreement with the laboratory measurements, proving that reducing the open porosity of FGG by mixing it with a material with smaller grains like EGG is promising for lowering convection risk. Nevertheless, insulation material selection and installation procedure is important to ensure homogeneous distribution and avoid material segregation or internal bulking that would lead to inhomogeneous insulation distribution.
- 23 November 2025
- Published by Springer Nature
- p. 998-1007
Optimization of a Multi-apartment HVAC System Using Simulation and Monitoring Data
- 23 November 2025
- Published by Springer Nature
- p. 998-1007
Optimization of a Multi-apartment HVAC System Using Simulation and Monitoring Data
- 23 November 2025
- Published by Springer Nature
- p. 499-509
Assessment of the Impact of Sound Emissions of Central and Decentral Air-to-Water Heat Pumps in a Renovation Project
- 23 November 2025
- Published by Springer Nature
- p. 499-509
Assessment of the Impact of Sound Emissions of Central and Decentral Air-to-Water Heat Pumps in a Renovation Project
- Open Access
- 29 April 2025
- Published by Elsevier in Journal of Building Engineering
- Vol. 107
Hygrothermal analysis of prefabricated façades with active components for minimal invasive renovations
- 29 April 2025
- Published by Elsevier in Journal of Building Engineering
- Vol. 107
Open AccessHygrothermal analysis of prefabricated façades with active components for minimal invasive renovations
- 6 December 2024
- Published by Springer Nature
- p. 11-17
Towards Digital Twin - Holistic Planning of Thermal Renovations with Heat Pumps in Multi-apartment Buildings
- 6 December 2024
- Published by Springer Nature
- p. 11-17
Towards Digital Twin - Holistic Planning of Thermal Renovations with Heat Pumps in Multi-apartment Buildings
- Open Access
- 2 February 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 243
Simulation-assisted design of a silent façade-integrated R290 mini-split heat pump
- 2 February 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 243
Open AccessSimulation-assisted design of a silent façade-integrated R290 mini-split heat pump
- Open Access
- 27 June 2023
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 17 (1) , 1-26
Monitoring and simulation-based optimization of two multi-apartment NZEBs with heat pump, solar thermal and PV
- 27 June 2023
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 17 (1) , 1-26
Open AccessMonitoring and simulation-based optimization of two multi-apartment NZEBs with heat pump, solar thermal and PV