Christophe Guillon
Research Subjects
Christophe Guillon has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
F. Le Guern
F4E Fusion for Energy 5 , Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona
3 shared publications- Fernando Mota
CIEMAT, Avenida Complutense 40, Madrid 28040, Spain
2 shared publications L. Letellier
CEA, IRFM, Saint-Paul-lez-Durance, France
2 shared publications- Marie-Hélène Aumeunier
IRFM
2 shared publications N. Lapcevic
CEA, IRFM, Cadarache 1 , St-Paul-Lez-Durance 13108
2 shared publications- Yannick Peneliau
IRFM
2 shared publications
Latest Publications
- 1 November 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (11)
Design, justification, and prototyping of the visible and infrared wide angle viewing system diagnostic for ITER equatorial port 12
The ITER equatorial visible and infrared Wide Angle Viewing System (WAVS) will play a major role in the protection of plasma facing components by providing surface temperature measurements of these components. It will also image the plasma emission in the visible range. The WAVS is composed of 15 lines of sight located in four Equatorial Ports (EPs) 3, 9, 12, and 17. Its development is being carried out by the Consortium constituted by CEA, CIEMAT, INTA, and Bertin Technologies, within grant contracts financed by F4E. In the EP12, the in-vessel and ex-vessel components of the WAVS are at their final design phase. This article presents an overview of the opto-mechanical design of the WAVS in the EP12 presented at the final design review.
- 1 November 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (11)
Design, justification, and prototyping of the visible and infrared wide angle viewing system diagnostic for ITER equatorial port 12
The ITER equatorial visible and infrared Wide Angle Viewing System (WAVS) will play a major role in the protection of plasma facing components by providing surface temperature measurements of these components. It will also image the plasma emission in the visible range. The WAVS is composed of 15 lines of sight located in four Equatorial Ports (EPs) 3, 9, 12, and 17. Its development is being carried out by the Consortium constituted by CEA, CIEMAT, INTA, and Bertin Technologies, within grant contracts financed by F4E. In the EP12, the in-vessel and ex-vessel components of the WAVS are at their final design phase. This article presents an overview of the opto-mechanical design of the WAVS in the EP12 presented at the final design review.
- 25 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 52 (6) , 2207-2212
Final Design and Tests of the In-Vessel Shutter of the ITER Wide Angle Viewing System (WAVS) in Equatorial Port 12
The ITER wide angle viewing system (WAVS) is a major diagnostic for machine protection, plasma control, and physics analysis. It will measure the surface temperature of the plasma-facing components by infrared thermography and will image the plasma emission in the visible range. The global system is composed of 15 lines of sight (LoS) located in four equatorial ports, covering 70% of the Tokamak internal surface. This article focuses on an in-vessel component, the shutter, present in each line of sight of the WAVS. Indeed, the shutter will protect the first mirrors from direct erosion due to fast particles from the plasma and/or direct contamination due to slow particles from glow discharges during first wall conditioning. Integrated within each first mirror unit, this mechanism is a critical component since it undergoes severe constraints, while it has to perform a robust cinematic to achieve 30 000 cycles over all ITER phases. The shutter mechanism consists of a pneumatic actuated bellows, which rotates a lever blade, thanks to its linear displacement through two pivots. Two electrical end switches monitor its stroke. On top of the protection function, the shutter incorporates an in situ infrared calibration source. This calibration source consists in a heater, regulated by a thermocouple and inserted on its moving blade. The shutter is fully water-cooled, except all mobile parts, such as the bellows and the blade. A prototype of this shutter has been developed, manufactured and tested. Over 100 000 actuations have been achieved under representative conditions while keeping its full operability. This article presents the shutter’s design presented at the FDR and describes its validation thanks to the thermal cycling tests.
- 25 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 52 (6) , 2207-2212
Final Design and Tests of the In-Vessel Shutter of the ITER Wide Angle Viewing System (WAVS) in Equatorial Port 12
The ITER wide angle viewing system (WAVS) is a major diagnostic for machine protection, plasma control, and physics analysis. It will measure the surface temperature of the plasma-facing components by infrared thermography and will image the plasma emission in the visible range. The global system is composed of 15 lines of sight (LoS) located in four equatorial ports, covering 70% of the Tokamak internal surface. This article focuses on an in-vessel component, the shutter, present in each line of sight of the WAVS. Indeed, the shutter will protect the first mirrors from direct erosion due to fast particles from the plasma and/or direct contamination due to slow particles from glow discharges during first wall conditioning. Integrated within each first mirror unit, this mechanism is a critical component since it undergoes severe constraints, while it has to perform a robust cinematic to achieve 30 000 cycles over all ITER phases. The shutter mechanism consists of a pneumatic actuated bellows, which rotates a lever blade, thanks to its linear displacement through two pivots. Two electrical end switches monitor its stroke. On top of the protection function, the shutter incorporates an in situ infrared calibration source. This calibration source consists in a heater, regulated by a thermocouple and inserted on its moving blade. The shutter is fully water-cooled, except all mobile parts, such as the bellows and the blade. A prototype of this shutter has been developed, manufactured and tested. Over 100 000 actuations have been achieved under representative conditions while keeping its full operability. This article presents the shutter’s design presented at the FDR and describes its validation thanks to the thermal cycling tests.
- 1 September 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 170
Electromagnetic analysis of ITER equatorial Wide Angle Viewing System (WAVS) in-vessel components
- 1 September 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 170
Electromagnetic analysis of ITER equatorial Wide Angle Viewing System (WAVS) in-vessel components
- Open Access
- 25 September 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 153, 02005
A Monte-Carlo Benchmark of TRIPOLI-4® and MCNP on ITER neutronics
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- 25 September 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 153, 02005
Open AccessA Monte-Carlo Benchmark of TRIPOLI-4® and MCNP on ITER neutronics
EPJ Web of Conferences, open-access proceedings in physics and astronomy