Ege Iseri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ege Iseri has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Gianluca Lazzi
University of Southern California
3 shared publications - Pragya Kosta
Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT, USA
2 shared publications Ben Yi Tew
Department of Translational Genomics, Keck School of Medicine, University of Southern California, USA
1 shared publicationBodour Salhia
Department of Translational Genomics, Keck School of Medicine, University of Southern California, USA
1 shared publication- Bryan William Jones
Moran Eye Center/Ophthalmology, University of Utah
1 shared publication - Constantine Sideris
Stanford University, Stanford, CA, USA
1 shared publication
Latest Publications
- 19 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (1) , 322-332
A Negative Impedance Converter Design to Enhance Capacitive Conduction Through a Neurostimulator Electrode Interface
Objective: With the growing interest in electric field-induced neuromodulation for clinical applications, optimizing circuitry and stimulation parameters is crucial for effective therapy. Studies have shown successful neuroregeneration, neuroprotection, and neuronal activation in vitro when electric fields exceed a certain threshold. However, clinical translation remains challenging, as stimulation amplitudes are often constrained by patient tolerance. Strategies that enhance charge delivery per phase within safety limits can improve the efficacy of these techniques. Approach: This paper presents a method to reduce the electrode-tissue interface time constant by incorporating a negative resistance circuit to lower the series resistance and an RC circuit to reduce the equivalent capacitance in a Thevenin model of the interface. By targeting the capacitive conduction phase with higher amplitudes, a voltage-controlled stimulator can deliver greater charge while remaining within tolerance limits. The proposed circuit models are validated in vivo by assessing the stimulation tolerance of rats at the optic nerve. Main Results: The proposed circuits connected in series with a two-electrode stimulator effectively reduced the time constant of the current waveform, shifting the magnitude response toward higher frequencies in Bode analysis. In vivo experiments confirmed that animals tolerated, on average, 20% greater charge injection within the first 200 $\mu$s of a rectangular pulse—the interval where capacitive charge transfer dominates over faradaic processes. Significance: Enhancing voltage-controlled neurostimulators with external circuits is a promising approach to overcoming amplitude limitations in clinical neurostimulation. As electrotherapy requires a minimum electric field amplitude for efficacy, increasing patient tolerance can improve treatment success rates.
- 19 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (1) , 322-332
A Negative Impedance Converter Design to Enhance Capacitive Conduction Through a Neurostimulator Electrode Interface
Objective: With the growing interest in electric field-induced neuromodulation for clinical applications, optimizing circuitry and stimulation parameters is crucial for effective therapy. Studies have shown successful neuroregeneration, neuroprotection, and neuronal activation in vitro when electric fields exceed a certain threshold. However, clinical translation remains challenging, as stimulation amplitudes are often constrained by patient tolerance. Strategies that enhance charge delivery per phase within safety limits can improve the efficacy of these techniques. Approach: This paper presents a method to reduce the electrode-tissue interface time constant by incorporating a negative resistance circuit to lower the series resistance and an RC circuit to reduce the equivalent capacitance in a Thevenin model of the interface. By targeting the capacitive conduction phase with higher amplitudes, a voltage-controlled stimulator can deliver greater charge while remaining within tolerance limits. The proposed circuit models are validated in vivo by assessing the stimulation tolerance of rats at the optic nerve. Main Results: The proposed circuits connected in series with a two-electrode stimulator effectively reduced the time constant of the current waveform, shifting the magnitude response toward higher frequencies in Bode analysis. In vivo experiments confirmed that animals tolerated, on average, 20% greater charge injection within the first 200 $\mu$s of a rectangular pulse—the interval where capacitive charge transfer dominates over faradaic processes. Significance: Enhancing voltage-controlled neurostimulators with external circuits is a promising approach to overcoming amplitude limitations in clinical neurostimulation. As electrotherapy requires a minimum electric field amplitude for efficacy, increasing patient tolerance can improve treatment success rates.
- 11 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (11) , 3221-3231
Characterization of Induced Current Density During Transcorneal Electrical Stimulation to Promote Neuroprotection in the Degenerating Retina
Objective: Transcorneal electrical stimulation (TES) is a promising approach to delay retinal degeneration by inducing extracellular electric field-driven neuroprotective effects within photoreceptors. Although achieving precise electric field control is feasible in vitro, characterizing these fields becomes intricate and largely unexplored in vivo due to uneven distribution in the heterogeneous body. In this paper, we investigate and characterize electric fields within the retina during TES to assess the potential for therapeutic approaches Methods: We developed a computational model of a rat's head, enabling us to generate predictive simulations of the voltage and current density induced in the retina. Subsequently, an in vivo experimental setup involving Royal College of Surgeon (RCS) rats was implemented to measure the voltage across the retina using identical electrode configurations as employed in the simulations. Results: A stimulation amplitude of 0.2–0.3 mA may be necessary during TES in rats to induce a current density of at least 20 A/ ${{{\bm{m}}}^2}$ in the retina, which is the lower limit for triggering neuroprotective effects according to culture studies on neural cells. Measurement taken from cadaveric pigs’ eyes revealed that a stimulation amplitude of 1 mA is necessary for achieving the same current density. Conclusion: The computational modeling approach presented in this study was validated with experimental data and can be leveraged for predictive simulations to optimize the electrode design and stimulation parameters of TES. Significance: Once validated, the flexibility and low research cost of computational models are valuable in optimization studies where testing on live subjects is not feasible.
- 11 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (11) , 3221-3231
Characterization of Induced Current Density During Transcorneal Electrical Stimulation to Promote Neuroprotection in the Degenerating Retina
Objective: Transcorneal electrical stimulation (TES) is a promising approach to delay retinal degeneration by inducing extracellular electric field-driven neuroprotective effects within photoreceptors. Although achieving precise electric field control is feasible in vitro, characterizing these fields becomes intricate and largely unexplored in vivo due to uneven distribution in the heterogeneous body. In this paper, we investigate and characterize electric fields within the retina during TES to assess the potential for therapeutic approaches Methods: We developed a computational model of a rat's head, enabling us to generate predictive simulations of the voltage and current density induced in the retina. Subsequently, an in vivo experimental setup involving Royal College of Surgeon (RCS) rats was implemented to measure the voltage across the retina using identical electrode configurations as employed in the simulations. Results: A stimulation amplitude of 0.2–0.3 mA may be necessary during TES in rats to induce a current density of at least 20 A/ ${{{\bm{m}}}^2}$ in the retina, which is the lower limit for triggering neuroprotective effects according to culture studies on neural cells. Measurement taken from cadaveric pigs’ eyes revealed that a stimulation amplitude of 1 mA is necessary for achieving the same current density. Conclusion: The computational modeling approach presented in this study was validated with experimental data and can be leveraged for predictive simulations to optimize the electrode design and stimulation parameters of TES. Significance: Once validated, the flexibility and low research cost of computational models are valuable in optimization studies where testing on live subjects is not feasible.
- 30 March 2021
- Published by Elsevier in Experimental Eye Research
- Vol. 207, 108554
Model-based comparison of current flow in rod bipolar cells of healthy and early-stage degenerated retina
- 30 March 2021
- Published by Elsevier in Experimental Eye Research
- Vol. 207, 108554
Model-based comparison of current flow in rod bipolar cells of healthy and early-stage degenerated retina