EIEge Iseri

Ege Iseri

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ege Iseri has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Negative Impedance Converter Design to Enhance Capacitive Conduction Through a Neurostimulator Electrode Interface

    by Ege Iseri, Manjunath Machnoor, Thanh D. Nguyen, Constantine Sideris, Kimberly K. Gokoffski, Gianluca Lazzi

    Objective: With the growing interest in electric field-induced neuromodulation for clinical applications, optimizing circuitry and stimulation parameters is crucial for effective therapy. Studies have shown successful neuroregeneration, neuroprotection, and neuronal activation in vitro when electric fields exceed a certain threshold. However, clinical translation remains challenging, as stimulation amplitudes are often constrained by patient tolerance. Strategies that enhance charge delivery per phase within safety limits can improve the efficacy of these techniques. Approach: This paper presents a method to reduce the electrode-tissue interface time constant by incorporating a negative resistance circuit to lower the series resistance and an RC circuit to reduce the equivalent capacitance in a Thevenin model of the interface. By targeting the capacitive conduction phase with higher amplitudes, a voltage-controlled stimulator can deliver greater charge while remaining within tolerance limits. The proposed circuit models are validated in vivo by assessing the stimulation tolerance of rats at the optic nerve. Main Results: The proposed circuits connected in series with a two-electrode stimulator effectively reduced the time constant of the current waveform, shifting the magnitude response toward higher frequencies in Bode analysis. In vivo experiments confirmed that animals tolerated, on average, 20% greater charge injection within the first 200 $\mu$s of a rectangular pulse—the interval where capacitive charge transfer dominates over faradaic processes. Significance: Enhancing voltage-controlled neurostimulators with external circuits is a promising approach to overcoming amplitude limitations in clinical neurostimulation. As electrotherapy requires a minimum electric field amplitude for efficacy, increasing patient tolerance can improve treatment success rates.


  • Characterization of Induced Current Density During Transcorneal Electrical Stimulation to Promote Neuroprotection in the Degenerating Retina

    by Ege Iseri, Pragya Kosta, Dimitrios Pollalis, Pei-An Lo, Ben Yi Tew, Stan Louie, Bodour Salhia, Mark Humayun, Gianluca Lazzi

    Objective: Transcorneal electrical stimulation (TES) is a promising approach to delay retinal degeneration by inducing extracellular electric field-driven neuroprotective effects within photoreceptors. Although achieving precise electric field control is feasible in vitro, characterizing these fields becomes intricate and largely unexplored in vivo due to uneven distribution in the heterogeneous body. In this paper, we investigate and characterize electric fields within the retina during TES to assess the potential for therapeutic approaches Methods: We developed a computational model of a rat's head, enabling us to generate predictive simulations of the voltage and current density induced in the retina. Subsequently, an in vivo experimental setup involving Royal College of Surgeon (RCS) rats was implemented to measure the voltage across the retina using identical electrode configurations as employed in the simulations. Results: A stimulation amplitude of 0.2–0.3 mA may be necessary during TES in rats to induce a current density of at least 20 A/ ${{{\bm{m}}}^2}$ in the retina, which is the lower limit for triggering neuroprotective effects according to culture studies on neural cells. Measurement taken from cadaveric pigs’ eyes revealed that a stimulation amplitude of 1 mA is necessary for achieving the same current density. Conclusion: The computational modeling approach presented in this study was validated with experimental data and can be leveraged for predictive simulations to optimize the electrode design and stimulation parameters of TES. Significance: Once validated, the flexibility and low research cost of computational models are valuable in optimization studies where testing on live subjects is not feasible.


  • Model-based comparison of current flow in rod bipolar cells of healthy and early-stage degenerated retina

    by Pragya Kosta, Ege Iseri, Kyle Loizos, Javad Paknahad, Rebecca L. Pfeiffer, Crystal L. Sigulinsky, James R. Anderson, Bryan W. Jones, Gianluca Lazzi