Jeongwon Yoo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jeongwon Yoo has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Choongki Sung
Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology 1 , Daejeon 34141
2 shared publications - Junghee Kim
Korea Institute of Fusion Energy 2 , Daejeon 34133
2 shared publications B. H. Park
Korea Institute of Fusion Energy 1 , 169-148 Gwahak-ro, Yuseong-gu, Daejeon 34133, Republic of Korea
1 shared publication- Hong-Sik Yun
Department of Nuclear Engineering, Seoul National University, Seoul, Republic of Korea
1 shared publication J. H. Lee
Korea Institute of Fusion Energy 1 , 169-148 Gwahak-ro, Yuseong-gu, Daejeon 34133, Republic of Korea
1 shared publication- Jae Young Jang
Department of Energy Systems Engineering, Seoul National University 1 , Seoul 08826, Republic of Korea
1 shared publication
Latest Publications
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Development of a multi-channel visible bremsstrahlung measurement system for the effective charge in the versatile experiment spherical torus (VEST)
A diagnostic system for measuring the effective charge in the versatile experiment spherical torus (VEST) has been developed. The system utilizes a toroidal array to observe the plasma radius on the low magnetic field side, providing a spatially resolved Zeff. The target wavelength of visible bremsstrahlung (VB) was carefully selected to avoid contamination by line emissions. The detector signal was calibrated using a halogen light source and an integrating sphere to obtain an absolute value of the radiative power from each chord. The local emissivity profile was reconstructed from the line-integrated VB emission using the Abel inversion method. Reconstruction tests were performed on various shapes of phantom profiles to effectively reconstruct the local emissivity from the measurements. We found that the initial measurements of the multi-channel VB system were consistent with the results of other independent measurements, supporting the validity of the new measurements. Finally, we obtained the initial result of Zeff in the VEST.
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Development of a multi-channel visible bremsstrahlung measurement system for the effective charge in the versatile experiment spherical torus (VEST)
A diagnostic system for measuring the effective charge in the versatile experiment spherical torus (VEST) has been developed. The system utilizes a toroidal array to observe the plasma radius on the low magnetic field side, providing a spatially resolved Zeff. The target wavelength of visible bremsstrahlung (VB) was carefully selected to avoid contamination by line emissions. The detector signal was calibrated using a halogen light source and an integrating sphere to obtain an absolute value of the radiative power from each chord. The local emissivity profile was reconstructed from the line-integrated VB emission using the Abel inversion method. Reconstruction tests were performed on various shapes of phantom profiles to effectively reconstruct the local emissivity from the measurements. We found that the initial measurements of the multi-channel VB system were consistent with the results of other independent measurements, supporting the validity of the new measurements. Finally, we obtained the initial result of Zeff in the VEST.
- 26 August 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 207
Feasibility study of fast-ion velocity-space tomography in KSTAR via phantom tests
- 26 August 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 207
Feasibility study of fast-ion velocity-space tomography in KSTAR via phantom tests
- 1 April 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (4) , 043504
Fast-ion Dα spectroscopy diagnostic at KSTAR
A fast-ion Dα (FIDA) diagnostics system was installed for core and edge measurements on KSTAR. This system has two tangential FIDA arrays that cover both blue- and redshifted Dα lines (cold: 656.09 nm) in active views along the neutral beam 1 A centerline. The spectral band is 647–662.5 nm, and it covers the Doppler shift of the emission from the maximum energy of the neutral beam (100 keV). A curved filter strip with a motorized stage adequately prevents saturation of the electron multiplying charge-coupled device signal by the cold Dα line from the plasma edge. From comparisons of the measured spectra and FIDASIM modeling code, the FIDA spectra are well matched quantitatively. Moreover, the first measurements show that the FIDA radiance agrees with the neutron rate in the time trace during external heating and perturbation. In addition, responses are observed in the core FIDA radiance during the edge-localized mode cycle.
- 1 April 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (4) , 043504
Fast-ion Dα spectroscopy diagnostic at KSTAR
A fast-ion Dα (FIDA) diagnostics system was installed for core and edge measurements on KSTAR. This system has two tangential FIDA arrays that cover both blue- and redshifted Dα lines (cold: 656.09 nm) in active views along the neutral beam 1 A centerline. The spectral band is 647–662.5 nm, and it covers the Doppler shift of the emission from the maximum energy of the neutral beam (100 keV). A curved filter strip with a motorized stage adequately prevents saturation of the electron multiplying charge-coupled device signal by the cold Dα line from the plasma edge. From comparisons of the measured spectra and FIDASIM modeling code, the FIDA spectra are well matched quantitatively. Moreover, the first measurements show that the FIDA radiance agrees with the neutron rate in the time trace during external heating and perturbation. In addition, responses are observed in the core FIDA radiance during the edge-localized mode cycle.