Jae Young Jang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jae Young Jang has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Seongcheol Kim
Department of Energy Systems Engineering, Seoul National University 1 , Seoul 08826, Republic of Korea
3 shared publicationsY.S. Hwang
3 shared publications- Yong-Seok Hwang
Department of Nuclear Engineering, Seoul National University, Seoul, Republic of Korea
3 shared publications - Choongki Sung
Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology 1 , Daejeon 34141
2 shared publications - Jung-Hwa Kim
Korea Institute of Fusion Energy, 169-148 Gwahak-ro, Yuseong-gu, Daejeon, Republic of Korea
2 shared publications - Byoung Seung Kim
Department of Plasma and Nuclear Fusion, UST-KFE School, Daejeon 34133, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 1 October 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 233
Operational stability and beam transport constraints in long-pulse neutral beam injection on KSTAR
- 1 October 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 233
Open AccessOperational stability and beam transport constraints in long-pulse neutral beam injection on KSTAR
- 2 September 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 207
The impact of stray magnetic fields on the KSTAR NBI performance
- 2 September 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 207
The impact of stray magnetic fields on the KSTAR NBI performance
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Development of a multi-channel visible bremsstrahlung measurement system for the effective charge in the versatile experiment spherical torus (VEST)
A diagnostic system for measuring the effective charge in the versatile experiment spherical torus (VEST) has been developed. The system utilizes a toroidal array to observe the plasma radius on the low magnetic field side, providing a spatially resolved Zeff. The target wavelength of visible bremsstrahlung (VB) was carefully selected to avoid contamination by line emissions. The detector signal was calibrated using a halogen light source and an integrating sphere to obtain an absolute value of the radiative power from each chord. The local emissivity profile was reconstructed from the line-integrated VB emission using the Abel inversion method. Reconstruction tests were performed on various shapes of phantom profiles to effectively reconstruct the local emissivity from the measurements. We found that the initial measurements of the multi-channel VB system were consistent with the results of other independent measurements, supporting the validity of the new measurements. Finally, we obtained the initial result of Zeff in the VEST.
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Development of a multi-channel visible bremsstrahlung measurement system for the effective charge in the versatile experiment spherical torus (VEST)
A diagnostic system for measuring the effective charge in the versatile experiment spherical torus (VEST) has been developed. The system utilizes a toroidal array to observe the plasma radius on the low magnetic field side, providing a spatially resolved Zeff. The target wavelength of visible bremsstrahlung (VB) was carefully selected to avoid contamination by line emissions. The detector signal was calibrated using a halogen light source and an integrating sphere to obtain an absolute value of the radiative power from each chord. The local emissivity profile was reconstructed from the line-integrated VB emission using the Abel inversion method. Reconstruction tests were performed on various shapes of phantom profiles to effectively reconstruct the local emissivity from the measurements. We found that the initial measurements of the multi-channel VB system were consistent with the results of other independent measurements, supporting the validity of the new measurements. Finally, we obtained the initial result of Zeff in the VEST.
- 1 September 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (9) , 093506
Development of a soft x-ray (SXR) array diagnostic system on versatile experiment spherical torus (VEST)
A new soft x-ray (SXR) array diagnostic system has been developed on versatile experiment spherical torus (VEST) for measurements of 2D SXR emissivity profile and identification of poloidal mode structure. Through tomographic inversion techniques, 2D SXR emissivity profile can be acquired from the line-integrated SXR data, which enables the visualization of mode structure of plasma instability, such as the magnetohydrodynamics mode. The SXR array diagnostic system consists of two 20-channel arrays positioned at the middle and the top on the same poloidal plane for horizontal and vertical lines of sight, respectively. Each array of the diagnostic system uses absolute extreme ultraviolet photodiode array as the detector. To apply appropriate filters (up to four) for different energy regimes without breaking the vacuum, a filter wheel and its rotatable vacuum feed-through are installed behind the pinhole. SXR data are acquired with a digitizer at the sampling rate of up to 125 MHz. Finally, we discuss initial measurement data obtained from Ohmic plasma in VEST.
- 1 September 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (9) , 093506
Development of a soft x-ray (SXR) array diagnostic system on versatile experiment spherical torus (VEST)
A new soft x-ray (SXR) array diagnostic system has been developed on versatile experiment spherical torus (VEST) for measurements of 2D SXR emissivity profile and identification of poloidal mode structure. Through tomographic inversion techniques, 2D SXR emissivity profile can be acquired from the line-integrated SXR data, which enables the visualization of mode structure of plasma instability, such as the magnetohydrodynamics mode. The SXR array diagnostic system consists of two 20-channel arrays positioned at the middle and the top on the same poloidal plane for horizontal and vertical lines of sight, respectively. Each array of the diagnostic system uses absolute extreme ultraviolet photodiode array as the detector. To apply appropriate filters (up to four) for different energy regimes without breaking the vacuum, a filter wheel and its rotatable vacuum feed-through are installed behind the pinhole. SXR data are acquired with a digitizer at the sampling rate of up to 125 MHz. Finally, we discuss initial measurement data obtained from Ohmic plasma in VEST.
- 25 October 2021
- Published by IOP Publishing in Nuclear Fusion
- Vol. 61 (12) , 126011
Acceleration of ion rotation during internal reconnection events in the versatile experiment spherical torus (VEST)
- 25 October 2021
- Published by IOP Publishing in Nuclear Fusion
- Vol. 61 (12) , 126011
Acceleration of ion rotation during internal reconnection events in the versatile experiment spherical torus (VEST)
- 1 October 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 171
Commissioning and initial heating results of the neutral beam injection system in Versatile Experiment Spherical Torus
- 1 October 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 171
Commissioning and initial heating results of the neutral beam injection system in Versatile Experiment Spherical Torus
- 1 May 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (5) , 053525
Development of an ultrafast charge exchange spectroscopy system on the KSTAR tokamak
An ultrafast charge exchange spectroscopy (UFCES) system has been designed for measuring fluctuations in ion temperature and toroidal rotation velocity. The UFCES on the KSTAR tokamak is a powerful tool for investigating plasma instabilities and long-wavelength turbulence related to ion temperature gradient and flow. The UFCES system is designed to measure the C VI line (n = 8 → 7, λ0 = 529.05 nm) from the charge exchange reaction between a deuterium-heating neutral beam and the intrinsic carbon impurity in KSTAR. The ion temperature and toroidal rotation velocity at two radial positions will be observed simultaneously with UFCES. The key difference between the UFCES system and conventional charge exchange spectrometers is the application of high-throughput collection optics, a high-efficiency transmission grating combined with prisms, and a high-speed detector. We use a comprehensive spectrum simulation code with input parameters of KSTAR’s plasmas and a neutral beam injection system to estimate the performance of the designed UFCES system. The results simulated with the code show that the diagnostic achieves a turbulence-relevant time resolution of 10 µs with a high enough signal-to-noise ratio. Furthermore, a preliminary test is performed using a complementary metal–oxide semiconductor camera and Ne spectral lamp to confirm the linear dispersion and curvature radius.
- 1 May 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (5) , 053525
Development of an ultrafast charge exchange spectroscopy system on the KSTAR tokamak
An ultrafast charge exchange spectroscopy (UFCES) system has been designed for measuring fluctuations in ion temperature and toroidal rotation velocity. The UFCES on the KSTAR tokamak is a powerful tool for investigating plasma instabilities and long-wavelength turbulence related to ion temperature gradient and flow. The UFCES system is designed to measure the C VI line (n = 8 → 7, λ0 = 529.05 nm) from the charge exchange reaction between a deuterium-heating neutral beam and the intrinsic carbon impurity in KSTAR. The ion temperature and toroidal rotation velocity at two radial positions will be observed simultaneously with UFCES. The key difference between the UFCES system and conventional charge exchange spectrometers is the application of high-throughput collection optics, a high-efficiency transmission grating combined with prisms, and a high-speed detector. We use a comprehensive spectrum simulation code with input parameters of KSTAR’s plasmas and a neutral beam injection system to estimate the performance of the designed UFCES system. The results simulated with the code show that the diagnostic achieves a turbulence-relevant time resolution of 10 µs with a high enough signal-to-noise ratio. Furthermore, a preliminary test is performed using a complementary metal–oxide semiconductor camera and Ne spectral lamp to confirm the linear dispersion and curvature radius.
- 1 December 2018
- Published by Elsevier in Fusion Engineering and Design
- Vol. 137, 358-361
Effect of boronization in VEST: Achieving 0.1 MA discharge
- 1 December 2018
- Published by Elsevier in Fusion Engineering and Design
- Vol. 137, 358-361
Effect of boronization in VEST: Achieving 0.1 MA discharge