Dinah Maria Brandner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dinah Maria Brandner has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Bernhard G. Zagar
Chair of Electrical Engineering, Montanuniversität Leoben, 8700 Leoben, Austria
2 shared publications - Bernhard G. Zagar
27266 Johannes Kepler Universität Linz , Institut für Elektrische Messtechnik , Altenbergerstraße 69 , 4040 Linz , Austria
1 shared publication Bernhard Gunther Zagar
Institute for Measurement Technology Johannes Kepler University Linz, Linz, Austria
1 shared publicationBernhard Zagar
Institute for Measurement Technology, Johannes Kepler University Linz,Linz,Austria
1 shared publication- Josquin Foiret
Department of Radiology, Stanford University, Stanford, CA, USA
1 shared publication - Katherine W. Ferrara
Department of Radiology, Stanford University, Stanford, CA, USA
1 shared publication
Latest Publications
- 21 June 2023
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 90 (10) , 672-682
Estimators of tissue absorption parameters power-law prefactor and power-law exponent from medical ultrasonic images
Ultrasound is a mechanical wave propagating in tissue which is influenced in its propagation behavior by the locally prevailing acousto-mechanical conditions. By suitable processing of the back-scattered signals received by the ultrasound transducer, tissue parameters such as local bulk modulus, mass density, speed of sound, isotropic scattering coefficient, and also the locally acting tissue absorption can be inferred. A discipline that has received increasing attention in the medical ultrasonic imaging discipline and its scientific publications in recent years is quantitative ultrasound (QUS) which tries to estimate with great accuracy these local acting tissue parameters. In this paper we analyze different algorithms for estimation of high spatial resolution tissue absorption parameters. On the one hand, there is a simple absorption estimator based on the evaluation of the quotient of the power density spectra calculated for different depth regions (spectral-log-difference estimator), which, however, assumes a linearly with frequency increasing absorption, this is contrasted with an estimator which also allows to estimate a polynomial increase of the absorption with frequency (method-of-moments estimator). Since a closed-form solution cannot be given for this, a maximum-likelihood estimator for which there is always an estimate that can be computed numerically efficiently is developed. The results, tissue attenuation, are presented as a color-coded overlay on conventional B-mode ultrasound images showing only morphology.
- 21 June 2023
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 90 (10) , 672-682
Estimators of tissue absorption parameters power-law prefactor and power-law exponent from medical ultrasonic images
Ultrasound is a mechanical wave propagating in tissue which is influenced in its propagation behavior by the locally prevailing acousto-mechanical conditions. By suitable processing of the back-scattered signals received by the ultrasound transducer, tissue parameters such as local bulk modulus, mass density, speed of sound, isotropic scattering coefficient, and also the locally acting tissue absorption can be inferred. A discipline that has received increasing attention in the medical ultrasonic imaging discipline and its scientific publications in recent years is quantitative ultrasound (QUS) which tries to estimate with great accuracy these local acting tissue parameters. In this paper we analyze different algorithms for estimation of high spatial resolution tissue absorption parameters. On the one hand, there is a simple absorption estimator based on the evaluation of the quotient of the power density spectra calculated for different depth regions (spectral-log-difference estimator), which, however, assumes a linearly with frequency increasing absorption, this is contrasted with an estimator which also allows to estimate a polynomial increase of the absorption with frequency (method-of-moments estimator). Since a closed-form solution cannot be given for this, a maximum-likelihood estimator for which there is always an estimate that can be computed numerically efficiently is developed. The results, tissue attenuation, are presented as a color-coded overlay on conventional B-mode ultrasound images showing only morphology.
- Open Access
- 19 August 2022
- Published by Springer Nature in e+i Elektrotechnik und Informationstechnik
- Vol. 139 (6) , 535-543
Schätzung der Gewebeabsorption aus medizinischen Ultraschall-Bildern
Zusammenfassung: Ultraschall ist eine sich im Gewebe ausbreitende mechanische Welle, die von den lokal vorherrschenden akusto-mechanischen Gegebenheiten in ihrem Ausbreitungsverhalten beeinflusst wird. Durch geeignete Verarbeitung der rückgestreuten und vom Ultraschallwandler empfangenen Signale kann daher auf Gewebeparameter, wie lokal wirkende Kompressionsmodule, Massendichte, Schallgeschwindigkeit, den isotropen Streukoeffizienten, aber auch auf die lokal wirkende Gewebeabsorption rückgeschlossen werden. Eine Disziplin, die in den letzten Jahren vermehrt Aufmerksamkeit in den wissenschaftlichen Publikationen zur medizinischen Ultraschallbildgebung gefunden hat, ist die Quantitative Ultraschall(QUS)-Analyse. In diesem Beitrag analysieren wir verschiedene Algorithmen zur Schätzung der örtlich hochaufgelösten Gewebeabsorption. Denn es wurde gezeigt, dass die Bereitstellung von farbcodierten Overlays von Absorptionsparametern über die herkömmlichen B‑mode-Ultraschall-Bilder, die ausschließlich die Morphologie darstellen, die diagnostische Qualität wesentlich verbessern kann.
- 19 August 2022
- Published by Springer Nature in e+i Elektrotechnik und Informationstechnik
- Vol. 139 (6) , 535-543
Open AccessSchätzung der Gewebeabsorption aus medizinischen Ultraschall-Bildern
Zusammenfassung: Ultraschall ist eine sich im Gewebe ausbreitende mechanische Welle, die von den lokal vorherrschenden akusto-mechanischen Gegebenheiten in ihrem Ausbreitungsverhalten beeinflusst wird. Durch geeignete Verarbeitung der rückgestreuten und vom Ultraschallwandler empfangenen Signale kann daher auf Gewebeparameter, wie lokal wirkende Kompressionsmodule, Massendichte, Schallgeschwindigkeit, den isotropen Streukoeffizienten, aber auch auf die lokal wirkende Gewebeabsorption rückgeschlossen werden. Eine Disziplin, die in den letzten Jahren vermehrt Aufmerksamkeit in den wissenschaftlichen Publikationen zur medizinischen Ultraschallbildgebung gefunden hat, ist die Quantitative Ultraschall(QUS)-Analyse. In diesem Beitrag analysieren wir verschiedene Algorithmen zur Schätzung der örtlich hochaufgelösten Gewebeabsorption. Denn es wurde gezeigt, dass die Bereitstellung von farbcodierten Overlays von Absorptionsparametern über die herkömmlichen B‑mode-Ultraschall-Bilder, die ausschließlich die Morphologie darstellen, die diagnostische Qualität wesentlich verbessern kann.
- 1 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 943-948
Preliminary Results on Ultrasonic Attenuation and Power-Law Exponent Imaging
Improving the diagnostic quality of imaging ultra-sound can be accomplished by augmenting the displayed B-mode images to also hint on acousto-mechanical tissue properties like speed of sound, mass density, scattering coefficient, and attenuation parameters like power-law prefactor and power-law exponent. The spatial resolution that needs to be attained for imaging these acousto-mechanical properties are related to the typical spatial extend of tissue features of the isonified organs. In case of cancers of the prostate or breast high resolution B-mode ultrasound images can be obtained since features are superficially located and thus allow for higher center frequency transducers with larger relative bandwidths. The parameter estimation ideally should match the B-mode's spatial resolution. We report on preliminary results of jointly estimating the power-law prefactor and the power-law exponent from standard ultrasonic images for typical values of tissue attenuation experienced in the human breast.
- 1 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 943-948
Preliminary Results on Ultrasonic Attenuation and Power-Law Exponent Imaging
Improving the diagnostic quality of imaging ultra-sound can be accomplished by augmenting the displayed B-mode images to also hint on acousto-mechanical tissue properties like speed of sound, mass density, scattering coefficient, and attenuation parameters like power-law prefactor and power-law exponent. The spatial resolution that needs to be attained for imaging these acousto-mechanical properties are related to the typical spatial extend of tissue features of the isonified organs. In case of cancers of the prostate or breast high resolution B-mode ultrasound images can be obtained since features are superficially located and thus allow for higher center frequency transducers with larger relative bandwidths. The parameter estimation ideally should match the B-mode's spatial resolution. We report on preliminary results of jointly estimating the power-law prefactor and the power-law exponent from standard ultrasonic images for typical values of tissue attenuation experienced in the human breast.
- 7 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Ultrasonic Attenuation Imaging — Comparison of Algorithms
According to the American Cancer Society, breast cancer is the second most common form of cancer in american women after skin cancer and the second major cause of cancer-related death after lung cancer. Still mammography is the imaging option guaranteeing the best diagnostic sensitivity but it causes high cost, is subjecting women to ionizing radiation, and is not readily available and not advisable to screen women on a very dense regular basis. Ultrasonic imaging, however is readily available in any gynecologist's clinic but still lags behind in sensitivity. Ultrasonic attenuation imaging, an imaging modality providing information on the local absorption property of the propagation medium, the various breast tissues, can help the clinician in her diagnosis by providing a color-coded overlay over the morphology that can be imaged using standard B-mode. We discuss and compare the results obtained by two attenuation estimation algorithms, the Method-of-Moments and the Spectral-log-Difference method operating on k-wave-simulated ultrasonic B-mode volume data. We also elaborate on the numerical complexity and the cost in terms of processing power necessary for both algorithms. The results show comparable performance with the MoM resulting in a smaller processor load as compared to the SLD technique.
- 7 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Ultrasonic Attenuation Imaging — Comparison of Algorithms
According to the American Cancer Society, breast cancer is the second most common form of cancer in american women after skin cancer and the second major cause of cancer-related death after lung cancer. Still mammography is the imaging option guaranteeing the best diagnostic sensitivity but it causes high cost, is subjecting women to ionizing radiation, and is not readily available and not advisable to screen women on a very dense regular basis. Ultrasonic imaging, however is readily available in any gynecologist's clinic but still lags behind in sensitivity. Ultrasonic attenuation imaging, an imaging modality providing information on the local absorption property of the propagation medium, the various breast tissues, can help the clinician in her diagnosis by providing a color-coded overlay over the morphology that can be imaged using standard B-mode. We discuss and compare the results obtained by two attenuation estimation algorithms, the Method-of-Moments and the Spectral-log-Difference method operating on k-wave-simulated ultrasonic B-mode volume data. We also elaborate on the numerical complexity and the cost in terms of processing power necessary for both algorithms. The results show comparable performance with the MoM resulting in a smaller processor load as compared to the SLD technique.
- Open Access
Estimation of Tissue Attenuation from Ultrasonic B-Mode Images—Spectral-Log-Difference and Method-of-Moments Algorithms Compared
We report on results from the comparison of two algorithms designed to estimate the attenuation coefficient from ultrasonic B-mode scans obtained from a numerical phantom simulating an ultrasound breast scan. It is well documented that this parameter significantly diverges between normal tissue and malignant lesions. To improve the diagnostic accuracy it is of great importance to devise and test algorithms that facilitate the accurate, low variance and spatially resolved estimation of the tissue’s attenuation properties. A numerical phantom is realized using k-Wave, which is an open source Matlab toolbox for the time-domain simulation of acoustic wave fields that facilitates both linear and nonlinear wave propagation in homogeneous and heterogeneous tissue, as compared to strictly linear ultrasound simulation tools like Field II. k-Wave allows to simulate arbitrary distributions, resolved down to single voxel sizes, of parameters including the speed of sound, mass density, scattering strength and to include power law acoustic absorption necessary for simulation tasks in medical diagnostic ultrasound. We analyze the properties and the attainable accuracy of both the spectral-log-difference technique, and a statistical moments based approach and compare the results to known reference values from the sound field simulation.
Open AccessEstimation of Tissue Attenuation from Ultrasonic B-Mode Images—Spectral-Log-Difference and Method-of-Moments Algorithms Compared
We report on results from the comparison of two algorithms designed to estimate the attenuation coefficient from ultrasonic B-mode scans obtained from a numerical phantom simulating an ultrasound breast scan. It is well documented that this parameter significantly diverges between normal tissue and malignant lesions. To improve the diagnostic accuracy it is of great importance to devise and test algorithms that facilitate the accurate, low variance and spatially resolved estimation of the tissue’s attenuation properties. A numerical phantom is realized using k-Wave, which is an open source Matlab toolbox for the time-domain simulation of acoustic wave fields that facilitates both linear and nonlinear wave propagation in homogeneous and heterogeneous tissue, as compared to strictly linear ultrasound simulation tools like Field II. k-Wave allows to simulate arbitrary distributions, resolved down to single voxel sizes, of parameters including the speed of sound, mass density, scattering strength and to include power law acoustic absorption necessary for simulation tasks in medical diagnostic ultrasound. We analyze the properties and the attainable accuracy of both the spectral-log-difference technique, and a statistical moments based approach and compare the results to known reference values from the sound field simulation.