Chakrit Panpean
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chakrit Panpean has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Kongpan Areerak
School of Electrical Engineering, Institute of Engineering, Suranaree University of Technology, Nakhon Ratchasima, Thailand
2 shared publications - Kongpol Areerak
School of Electrical Engineering, Institute of Engineering, Suranaree University of Technology, Nakhon Ratchasima, Thailand
2 shared publications - Phonsit Santiprapan
Department of Electrical and Biomedical Engineering, Faculty of Engineering, Prince of Songkla University, Songkhla, Thailand
2 shared publications - Chirdpong Deelertpaiboon1 shared publication
- Ittiphong Yongyee
Department of Electrical and Computer Engineering, Faculty of Engineering, King Mongkut’s University of Technology North Bangkok (KMUTNB), Bangkok 10800, Thailand
1 shared publication Jeerawan Homjan
Department of Mechatronics Engineering, Rajamangala University of Technology Suvarnabhumi, Nonthaburi, Thailand
1 shared publication
Latest Publications
- 1 December 2026
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 15 (6) , 4850-4862
Artificial intelligence–based design of proportional-integral controllers for active power filters in railway electrification
Conventional tuning of proportional–integral (PI) controllers for active power filters (APFs) cannot ensure optimal improvement of power quality performance in electric railway applications. This research introduces an artificial intelligence (AI) methodology for the design of a PI controller in electric railway systems. The adaptive Tabu search (ATS) algorithm is utilized to search for the optimal parameters of a compensating current controller and direct current (DC) bus voltage controller, with the aim of concurrently optimizing harmonic current suppression, current imbalance compensation, and power factor (PF) correction. The efficacy of the proposed method is assessed via hardware-in-the-loop (HIL) simulation. Experimental results validate that the compensating current controller and DC bus voltage controller, designed using the ATS algorithm, demonstrably improve harmonic mitigation performance. This enhancement is substantiated through the power quality index, specifically the percentage of total harmonic distortion of current (%THDi), percentage of current unbalance factor (%CUF), and the PF compliance with the IEEE standard. Consequently, the proposed approach offers a practical and effective solution for elevating power quality within electric railway systems.
- 1 December 2026
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 15 (6) , 4850-4862
Artificial intelligence–based design of proportional-integral controllers for active power filters in railway electrification
Conventional tuning of proportional–integral (PI) controllers for active power filters (APFs) cannot ensure optimal improvement of power quality performance in electric railway applications. This research introduces an artificial intelligence (AI) methodology for the design of a PI controller in electric railway systems. The adaptive Tabu search (ATS) algorithm is utilized to search for the optimal parameters of a compensating current controller and direct current (DC) bus voltage controller, with the aim of concurrently optimizing harmonic current suppression, current imbalance compensation, and power factor (PF) correction. The efficacy of the proposed method is assessed via hardware-in-the-loop (HIL) simulation. Experimental results validate that the compensating current controller and DC bus voltage controller, designed using the ATS algorithm, demonstrably improve harmonic mitigation performance. This enhancement is substantiated through the power quality index, specifically the percentage of total harmonic distortion of current (%THDi), percentage of current unbalance factor (%CUF), and the PF compliance with the IEEE standard. Consequently, the proposed approach offers a practical and effective solution for elevating power quality within electric railway systems.
- Open Access
- 12 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 160829-160844
Control Strategy Improvement of Active Power Filters for Harmonic Elimination in Heavy Rail Systems With Installed PV Arrays
Electric train transportation requires a substantial amount of electrical energy to power trains’ propulsion systems. Consequently, photovoltaic (PV) arrays are considered for installation at traction substations in heavy rail systems to supply this energy. However, nonlinear loads in heavy rail systems cause power quality issues that affect the grid distribution system. To mitigate these issues, an active power filter (APF) is employed to eliminate harmonics and improve the power factor. This paper introduces an APF control strategy for heavy rail systems integrated with installed PV arrays. The proposed harmonic detection method for calculating the APF reference current has been improved to achieve fast computation and more accurate reference current value. In addition, the injection of compensating current by the APF is controlled using a model predictive current control strategy, which incorporates a current injection model through a transformer for high voltage system. The MPC controller effectively compensates for digital delays and minimizes the ripple in the compensating current. Real-time simulations conducted on OPAL RT-LAB hardware was used to verify the performance of the proposed control strategy. The experimental results confirm that the proposed APF control strategy effectively eliminates harmonics and complies with IEEE 519-2022 and MEA standards for power factor correction in heavy rail systems.
- 12 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 160829-160844
Open AccessControl Strategy Improvement of Active Power Filters for Harmonic Elimination in Heavy Rail Systems With Installed PV Arrays
Electric train transportation requires a substantial amount of electrical energy to power trains’ propulsion systems. Consequently, photovoltaic (PV) arrays are considered for installation at traction substations in heavy rail systems to supply this energy. However, nonlinear loads in heavy rail systems cause power quality issues that affect the grid distribution system. To mitigate these issues, an active power filter (APF) is employed to eliminate harmonics and improve the power factor. This paper introduces an APF control strategy for heavy rail systems integrated with installed PV arrays. The proposed harmonic detection method for calculating the APF reference current has been improved to achieve fast computation and more accurate reference current value. In addition, the injection of compensating current by the APF is controlled using a model predictive current control strategy, which incorporates a current injection model through a transformer for high voltage system. The MPC controller effectively compensates for digital delays and minimizes the ripple in the compensating current. Real-time simulations conducted on OPAL RT-LAB hardware was used to verify the performance of the proposed control strategy. The experimental results confirm that the proposed APF control strategy effectively eliminates harmonics and complies with IEEE 519-2022 and MEA standards for power factor correction in heavy rail systems.
- Open Access
Harmonic Mitigation in Electric Railway Systems Using Improved Model Predictive Control
An electric multiple unit (EMU) high-speed train is the dynamic load that degrades the power quality in an electric railway system. Therefore, a power quality improvement system using an active power filter (APF) must be considered. Due to the oscillating load current in the dynamic load condition, a fast and accurate harmonic current-tracking performance is required. As such, this paper proposes the design of a model predictive control (MPC) since the minimization of cost function in the MPC process can suitably determine APF switching states. The design technique of MPC is based on the APF mathematical model. This controller was designed to compensate the time delay in the digital control. Moreover, the synchronous detection (SD) method applied the reference current calculations, as shown in this paper. To verify the proposed MPC, the overall control of APF was implemented on a eZdsp F28335 board by using the hardware-in-the-loop technique. The testing results indicated that the proposed MPC can provide a fast and accurate harmonic current-tracking response compared with the proportional-integral controller. In the load changing condition, the MPC was still effective in providing a good result after compensation. The percentage of total harmonic distortion, the percentage current unbalance factor, and the power factor would also be kept within the IEEE Standard 519 and IEEE Standard 1459.
Open AccessHarmonic Mitigation in Electric Railway Systems Using Improved Model Predictive Control
An electric multiple unit (EMU) high-speed train is the dynamic load that degrades the power quality in an electric railway system. Therefore, a power quality improvement system using an active power filter (APF) must be considered. Due to the oscillating load current in the dynamic load condition, a fast and accurate harmonic current-tracking performance is required. As such, this paper proposes the design of a model predictive control (MPC) since the minimization of cost function in the MPC process can suitably determine APF switching states. The design technique of MPC is based on the APF mathematical model. This controller was designed to compensate the time delay in the digital control. Moreover, the synchronous detection (SD) method applied the reference current calculations, as shown in this paper. To verify the proposed MPC, the overall control of APF was implemented on a eZdsp F28335 board by using the hardware-in-the-loop technique. The testing results indicated that the proposed MPC can provide a fast and accurate harmonic current-tracking response compared with the proportional-integral controller. In the load changing condition, the MPC was still effective in providing a good result after compensation. The percentage of total harmonic distortion, the percentage current unbalance factor, and the power factor would also be kept within the IEEE Standard 519 and IEEE Standard 1459.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 545-548
The Harmonic Detection for Co-Phase Railway System in Distorted Voltage Source Condition
This paper presents the enhanced harmonic detection of active power filter (APF) for co-phase railway system in distorted voltage source condition. The instantaneous power theory (PQ) with positive sequence voltage detector (PSVD) is applied for the harmonic detection called PQ+PSVD algorithm. In the paper, the compensating current and DC bus voltage of the APF are controlled by the PI controller. The APFs and the proposed harmonic detection in co-phase traction power system are simulated using MATLAB/Simulink program. In distorted voltage condition, the simulation results show that the APFs with the proposed algorithm can keep a good performance for harmonic elimination. Moreover, the performance index (%{it THD) can also follow the IEEE std.519-2014.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 545-548
The Harmonic Detection for Co-Phase Railway System in Distorted Voltage Source Condition
This paper presents the enhanced harmonic detection of active power filter (APF) for co-phase railway system in distorted voltage source condition. The instantaneous power theory (PQ) with positive sequence voltage detector (PSVD) is applied for the harmonic detection called PQ+PSVD algorithm. In the paper, the compensating current and DC bus voltage of the APF are controlled by the PI controller. The APFs and the proposed harmonic detection in co-phase traction power system are simulated using MATLAB/Simulink program. In distorted voltage condition, the simulation results show that the APFs with the proposed algorithm can keep a good performance for harmonic elimination. Moreover, the performance index (%{it THD) can also follow the IEEE std.519-2014.