Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ittiphong Yongyee has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Artificial intelligence–based design of proportional-integral controllers for active power filters in railway electrification

    by Chakrit Panpean, Chirdpong Deelertpaiboon, Jeerawan Homjan, Ittiphong Yongyee, Warunee Srisongkram, Napat Watjanatepin

    Conventional tuning of proportional–integral (PI) controllers for active power filters (APFs) cannot ensure optimal improvement of power quality performance in electric railway applications. This research introduces an artificial intelligence (AI) methodology for the design of a PI controller in electric railway systems. The adaptive Tabu search (ATS) algorithm is utilized to search for the optimal parameters of a compensating current controller and direct current (DC) bus voltage controller, with the aim of concurrently optimizing harmonic current suppression, current imbalance compensation, and power factor (PF) correction. The efficacy of the proposed method is assessed via hardware-in-the-loop (HIL) simulation. Experimental results validate that the compensating current controller and DC bus voltage controller, designed using the ATS algorithm, demonstrably improve harmonic mitigation performance. This enhancement is substantiated through the power quality index, specifically the percentage of total harmonic distortion of current (%THDi), percentage of current unbalance factor (%CUF), and the PF compliance with the IEEE standard. Consequently, the proposed approach offers a practical and effective solution for elevating power quality within electric railway systems.

  • Open Access

    Creating a digital industrial production system for control in mechatronics works

    by Ittiphong Yongyee, Promphak Boonraksa, Wipada Wongsuriya, Sarun Chattunyakit, Warunee Srisongkram

    This study presents the design and implementation of a production system for digital industrial applications with a focus on mechatronics control. The primary objective is to evaluate system performance using Overall Equipment Effectiveness (OEE) within a digitally integrated manufacturing environment. Operational parameters were established to maintain optimal production cycle times, and the Ideal Cycle Time (ICT) per unit was defined to ensure controllability. Experimental evaluations were conducted across multiple production cycles to quantify the principal OEE components: Availability, representing machine uptime and mitigation of unplanned downtime; Performance, reflecting production rate relative to predefined standards; and Quality, indicating product conformance and defect rates. The results demonstrate that the production system attains high overall effectiveness, exhibiting consistent availability, production speed, and product quality in alignment with industrial benchmarks. Notably, the system shows robustness in maintaining stable cycle times and product quality across most production rounds. Nevertheless, certain cycles experienced reduced availability due to elevated downtime, directly affecting overall OEE. The findings suggest that implementing strategies to minimize unplanned downtime and optimize planned maintenance can further enhance system performance, promoting sustained operational efficiency and reliability in advanced manufacturing settings.

  • Open Access

    Age Estimation of Transmission Line Using Statistical Health Index and Failure Probability Curve-Fitting Method

    by Cattareeya Suwanasri, Ittiphong Yongyee, Thanapong Suwanasri

    The aging process of transmission lines has a direct impact on the reliability and safety of the power grid. Therefore, an accurate age estimation method is imperative for effective maintenance planning and infrastructure investment. This paper introduces a systematic methodology for estimating the age of overhead transmission lines, utilizing the percentage statistical health index (%SHI) and the failure probability curve-fitting (FPCF) method. The %SHI, employing a scoring and weighting approach derived from test results and inspections, is used to assess the actual condition of transmission line equipment. Additionally, the FPCF approach is applied to illustrate the connection between the SHI and the likelihood of failure, facilitating the assessment of transmission line age by fitting failure probability curves to the SHI data. This age is directly associated with the probability of experiencing a failure. The evaluation was conducted on 924 towers situated along four transmission lines connecting the 115 kV substations S1–S2, S3–S4, S5–S6, and S7–S8. These transmission lines are in four regions with diverse terrain and environments such as mountains, rice fields, and more. In the SHI calculation, practical testing results and historical failure data were applied. The results clearly indicate that there were notable disparities in the age estimations for transmission lines in diverse geographical regions of Thailand when compared to their actual ages. These discrepancies can be attributed to various factors, including the local environment, such as rainfall, flooding, and salt-laden air as well as specific geographical features like mountainous and coastal terrain. To mitigate the deterioration of transmission lines in all regions, it is essential to implement a proactive maintenance strategy. This strategy should involve more frequent inspections, the use of advanced monitoring technologies, and the establishment of robust maintenance procedures, with which it would become possible to enhance the accuracy of equipment condition assessments, ultimately resulting in an overall improvement in the reliability of transmission lines.