Igor Bezukladnikov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Igor Bezukladnikov has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Dmitriy Nikolaevich Trushnikov
Department of Welding Production, Metrology and Technology of Material, Perm National Research Polytechnic University, 29 Komsomolsky Prospect, 614990 Perm, Russia
4 shared publications - Alexander A. Oskolkov
Department of Welding Production, Metrology and Technology of Material, Perm National Research Polytechnic University, 29 Komsomolsky Prospect, 614990 Perm, Russia
3 shared publications - Alexander A. Yuzhakov
Perm National Research Polytechnic University
3 shared publications Aleksandr Yuzhakov
2 shared publicationsAnna Mironova
2 shared publications- Alexey Elovikov
Permskiy gosudarstvennyy medicinskiy universitet imeni akademika E. A. Vagnera
1 shared publication
Latest Publications
- 1 September 2025
- Published by Allerton Press in Russian Engineering Research
- Vol. 45 (9) , 1288-1289
Improving Wire Supply for Electron Beam Additive Surfacing
A system for wire supply in electron beam additive surfacing is proposed. This system ensures high accuracy in wire supply to the electron beam and effecti
- 1 September 2025
- Published by Allerton Press in Russian Engineering Research
- Vol. 45 (9) , 1288-1289
Improving Wire Supply for Electron Beam Additive Surfacing
A system for wire supply in electron beam additive surfacing is proposed. This system ensures high accuracy in wire supply to the electron beam and effecti
- Open Access
- 10 February 2025
- Published by TIRAZH Publishing House in Actual problems in dentistry
- Vol. 20 (4) , 168-174
BIONIC EAR AS A NEW SYSTEM FOR REHABILITATION OF PATIENTS WITH MICROTIA
Subject – the technology for prosthetics of patients with microtia (anotia) using the developed design of a bionic auricular prosthesis, the use of which is aimed at replacing facial defects and restoring conductive and mixed hearing. Objectives. To develop a design of a bionic ear prosthesis and a method for its fixation based on the use of biocompatible materials and modern technologies. Methodology. The epithesis is manufactured using computer modeling, using the patient's CT scan as the initial data. The main structural elements (the frame of the external overhead device and the fixation elements) are obtained using 3D printing. The electronic components of the hearing aid, including the sound vibration emitter (transducer) and battery, are located inside the prosthesis structure. Results. The bionic ear prosthesis consists of several structures, including a silicone auricle with an inserted sound processor. The epithesis of the auricle in the structure of the bionic ear prosthesis can be combined – consisting of a polymer frame coated with silicone or completely made of silicone material. The structure can be fixed both with titanium osseointegrative implants and combined implantation systems, including a sleeve made of carbon-carbon composite material of compact structure and a titanium rod, used depending on the existing clinical conditions. The bionic ear prosthesis is integrated into the patient's digital environment based on modern engineering and medical 3D technologies. Conclusion. The proposed approach to auricular prosthetics will allow achieving the naturalness of the replacement structure by introducing bone conduction into its structure of the hearing apparatus.
- 10 February 2025
- Published by TIRAZH Publishing House in Actual problems in dentistry
- Vol. 20 (4) , 168-174
Open AccessBIONIC EAR AS A NEW SYSTEM FOR REHABILITATION OF PATIENTS WITH MICROTIA
Subject – the technology for prosthetics of patients with microtia (anotia) using the developed design of a bionic auricular prosthesis, the use of which is aimed at replacing facial defects and restoring conductive and mixed hearing. Objectives. To develop a design of a bionic ear prosthesis and a method for its fixation based on the use of biocompatible materials and modern technologies. Methodology. The epithesis is manufactured using computer modeling, using the patient's CT scan as the initial data. The main structural elements (the frame of the external overhead device and the fixation elements) are obtained using 3D printing. The electronic components of the hearing aid, including the sound vibration emitter (transducer) and battery, are located inside the prosthesis structure. Results. The bionic ear prosthesis consists of several structures, including a silicone auricle with an inserted sound processor. The epithesis of the auricle in the structure of the bionic ear prosthesis can be combined – consisting of a polymer frame coated with silicone or completely made of silicone material. The structure can be fixed both with titanium osseointegrative implants and combined implantation systems, including a sleeve made of carbon-carbon composite material of compact structure and a titanium rod, used depending on the existing clinical conditions. The bionic ear prosthesis is integrated into the patient's digital environment based on modern engineering and medical 3D technologies. Conclusion. The proposed approach to auricular prosthetics will allow achieving the naturalness of the replacement structure by introducing bone conduction into its structure of the hearing apparatus.
- Open Access
Mathematical Model of the Layer-by-Layer FFF/FGF Polymer Extrusion Process for Use in the Algorithm of Numerical Implementation of Real-Time Thermal Cycle Control
An approach for improving and maintaining a consistent weld quality of the deposited material during the FFF printing process is proposed. The approach is based on the analysis of the printing process thermal cycle and the real-time nozzle temperature control. The mathematical model of the FFF printing process has been developed with the use of real-time control in the algorithm of numerical implementation. The successful solution of the thermal conductivity problem made it possible to determine segment-wise heating settings for use during the printing process, resulting in a high and stable quality of welding. Comparison of the results of modeling with other well-known mathematical models of the FFF printing process and experimental results showed the adequacy of the proposed model. A maximum deviation of 17.7% between the simulation results and the thermography data was observed. The proposed model was verified using rectangular 3D polylactide shapes printed with and without regulation of the power of the heat source according to the previously estimated settings. The overall quality of regulation, stability of the system, and the PI coefficients of the controller were evaluated using a simulated model of the control system. The results of the experiment fully correspond with the modeling results.
Open AccessMathematical Model of the Layer-by-Layer FFF/FGF Polymer Extrusion Process for Use in the Algorithm of Numerical Implementation of Real-Time Thermal Cycle Control
An approach for improving and maintaining a consistent weld quality of the deposited material during the FFF printing process is proposed. The approach is based on the analysis of the printing process thermal cycle and the real-time nozzle temperature control. The mathematical model of the FFF printing process has been developed with the use of real-time control in the algorithm of numerical implementation. The successful solution of the thermal conductivity problem made it possible to determine segment-wise heating settings for use during the printing process, resulting in a high and stable quality of welding. Comparison of the results of modeling with other well-known mathematical models of the FFF printing process and experimental results showed the adequacy of the proposed model. A maximum deviation of 17.7% between the simulation results and the thermography data was observed. The proposed model was verified using rectangular 3D polylactide shapes printed with and without regulation of the power of the heat source according to the previously estimated settings. The overall quality of regulation, stability of the system, and the PI coefficients of the controller were evaluated using a simulated model of the control system. The results of the experiment fully correspond with the modeling results.
- Open Access
- 11 August 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (16) , 8064
Rapid Temperature Control in Melt Extrusion Additive Manufacturing Using Induction Heated Lightweight Nozzle
An approach for improving and maintaining consistent fusion quality of the deposited material during FDM 3d-printing is proposed. This approach is based on the nozzle temperature control during the printing process to adjust the polymer extrusion temperature with a speed and accuracy adequate to the FDM process. High frequency induction heating of the lightweight nozzle (<1 g) was used. To control the temperature of a lightweight nozzle, the resonant temperature measurement method based on the analysis of the high frequency eddy currents is proposed. To determine the parameters of the nozzle and the inductor as a plant, a FEM model of the inductive heating of the nozzle and a simulated model of a serial-parallel resonant circuit containing inductor were developed. Linearization of the automatic control system was performed to ensure the equal quality of regulation when operating in a wide temperature range. The quality of regulation, stability of the system, and coefficients of the PID controller were evaluated using a simulated model of the control system. A number of test samples were printed from various materials, and tensile stress testing was carried out. The developed control method reduces the nozzle temperature control error from 20 to 0.2 °C and decreases control delay by more than six times.
- 11 August 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (16) , 8064
Open AccessRapid Temperature Control in Melt Extrusion Additive Manufacturing Using Induction Heated Lightweight Nozzle
An approach for improving and maintaining consistent fusion quality of the deposited material during FDM 3d-printing is proposed. This approach is based on the nozzle temperature control during the printing process to adjust the polymer extrusion temperature with a speed and accuracy adequate to the FDM process. High frequency induction heating of the lightweight nozzle (<1 g) was used. To control the temperature of a lightweight nozzle, the resonant temperature measurement method based on the analysis of the high frequency eddy currents is proposed. To determine the parameters of the nozzle and the inductor as a plant, a FEM model of the inductive heating of the nozzle and a simulated model of a serial-parallel resonant circuit containing inductor were developed. Linearization of the automatic control system was performed to ensure the equal quality of regulation when operating in a wide temperature range. The quality of regulation, stability of the system, and coefficients of the PID controller were evaluated using a simulated model of the control system. A number of test samples were printed from various materials, and tensile stress testing was carried out. The developed control method reduces the nozzle temperature control error from 20 to 0.2 °C and decreases control delay by more than six times.
- Open Access
Indirect Temperature Measurement in High Frequency Heating Systems
One of the biggest challenges of fused deposition modeling (FDM)/fused filament fabrication (FFF) 3D-printing is maintaining consistent quality of layer-to-layer adhesion, and on the larger scale, homogeneity of material inside the whole printed object. An approach for mitigating and/or resolving those problems, based on the rapid and reliable control of the extruded material temperature during the printing process, was proposed. High frequency induction heating of the nozzle with a minimum mass ( 300 W) heating system, an indirect (eddy current) temperature measurement method was proposed. It is based on dynamic analysis over various temperature-dependent parameters directly in the process of heating. To ensure better temperature measurement accuracy, a series-parallel resonant circuit containing an induction heating coil, an approach of desired signal detection, algorithms for digital signal processing and a regression model that determines the dependence of the desired signal on temperature and magnetic field strength were proposed. The testbed system designed to confirm the results of the conducted research showed the effectiveness of the proposed indirect measurement method. With an accuracy of ±3 °C, the measurement time is 20 ms in the operating temperature range from 50 to 350 °C. The designed temperature control system based on an indirect measurement method will provide high mechanical properties and consistent quality of printed objects.
Open AccessIndirect Temperature Measurement in High Frequency Heating Systems
One of the biggest challenges of fused deposition modeling (FDM)/fused filament fabrication (FFF) 3D-printing is maintaining consistent quality of layer-to-layer adhesion, and on the larger scale, homogeneity of material inside the whole printed object. An approach for mitigating and/or resolving those problems, based on the rapid and reliable control of the extruded material temperature during the printing process, was proposed. High frequency induction heating of the nozzle with a minimum mass ( 300 W) heating system, an indirect (eddy current) temperature measurement method was proposed. It is based on dynamic analysis over various temperature-dependent parameters directly in the process of heating. To ensure better temperature measurement accuracy, a series-parallel resonant circuit containing an induction heating coil, an approach of desired signal detection, algorithms for digital signal processing and a regression model that determines the dependence of the desired signal on temperature and magnetic field strength were proposed. The testbed system designed to confirm the results of the conducted research showed the effectiveness of the proposed indirect measurement method. With an accuracy of ±3 °C, the measurement time is 20 ms in the operating temperature range from 50 to 350 °C. The designed temperature control system based on an indirect measurement method will provide high mechanical properties and consistent quality of printed objects.