JRJosé Esteban Ruiz
José Esteban Ruiz
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
José Esteban Ruiz has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Esther Pueyo
Universidad de Zaragoza
3 shared publications - Pablo Laguna
University of Zaragoza
3 shared publications - Carlos Sánchez
BSICoS Group, I3A Institute, IIS Aragón, University of Zaragoza, 50018 Zaragoza, Spain
2 shared publications - Dina Ferreira
Laboratorios Rubió, Castellbisbal, 08755 Barcelona, Spain
2 shared publications - Flavio Palmieri
Biophysics Unit, Department of Physiological Sciences School of Medicine, University of Barcelona, L’Hospitalet de Llobregat, Spain
2 shared publications - Julia Ramírez
University of Zaragoza
2 shared publications
Latest Publications
- Open Access
Monitoring of Serum Potassium and Calcium Levels in End-Stage Renal Disease Patients by ECG Depolarization Morphology Analysis
Objective: Non-invasive estimation of serum potassium, , and calcium, , can help to prevent life-threatening ventricular arrhythmias in patients with advanced renal disease, but current methods for estimation of electrolyte levels have limitations. We aimed to develop new markers based on the morphology of the QRS complex of the electrocardiogram (ECG). Methods: ECG recordings from 29 patients undergoing hemodialysis (HD) were processed. Mean warped QRS complexes were computed in two-minute windows at the start of an HD session, at the end of each HD hour and 48 h after it. We quantified QRS width, amplitude and the proposed QRS morphology-based markers that were computed by warping techniques. Reference and were determined from blood samples acquired at the time points where the markers were estimated. Linear regression models were used to estimate electrolyte levels from the QRS markers individually and in combination with T wave morphology markers. Leave-one-out cross-validation was used to assess the performance of the estimators. Results: All markers, except for QRS width, strongly correlated with (median Pearson correlation coefficients, r, ranging from 0.81 to 0.87) and with (r ranging from 0.61 to 0.76). QRS morphology markers showed very low sensitivity to heart rate (HR). Actual and estimated serum electrolyte levels differed, on average, by less than 0.035 mM (relative error of 0.018) for and 0.010 mM (relative error of 0.004) for when patient-specific multivariable estimators combining QRS and T wave markers were used. Conclusion: QRS morphological markers allow non-invasive estimation of and with low sensitivity to HR. The estimation performance is improved when multivariable models, including T wave markers, are considered. Significance: Markers based on the QRS complex of the ECG could contribute to non-invasive monitoring of serum electrolyte levels and arrhythmia risk prediction in patients with renal disease.Open AccessMonitoring of Serum Potassium and Calcium Levels in End-Stage Renal Disease Patients by ECG Depolarization Morphology Analysis
Objective: Non-invasive estimation of serum potassium, , and calcium, , can help to prevent life-threatening ventricular arrhythmias in patients with advanced renal disease, but current methods for estimation of electrolyte levels have limitations. We aimed to develop new markers based on the morphology of the QRS complex of the electrocardiogram (ECG). Methods: ECG recordings from 29 patients undergoing hemodialysis (HD) were processed. Mean warped QRS complexes were computed in two-minute windows at the start of an HD session, at the end of each HD hour and 48 h after it. We quantified QRS width, amplitude and the proposed QRS morphology-based markers that were computed by warping techniques. Reference and were determined from blood samples acquired at the time points where the markers were estimated. Linear regression models were used to estimate electrolyte levels from the QRS markers individually and in combination with T wave morphology markers. Leave-one-out cross-validation was used to assess the performance of the estimators. Results: All markers, except for QRS width, strongly correlated with (median Pearson correlation coefficients, r, ranging from 0.81 to 0.87) and with (r ranging from 0.61 to 0.76). QRS morphology markers showed very low sensitivity to heart rate (HR). Actual and estimated serum electrolyte levels differed, on average, by less than 0.035 mM (relative error of 0.018) for and 0.010 mM (relative error of 0.004) for when patient-specific multivariable estimators combining QRS and T wave markers were used. Conclusion: QRS morphological markers allow non-invasive estimation of and with low sensitivity to HR. The estimation performance is improved when multivariable models, including T wave markers, are considered. Significance: Markers based on the QRS complex of the ECG could contribute to non-invasive monitoring of serum electrolyte levels and arrhythmia risk prediction in patients with renal disease. - Open Access
Nonlinear T-Wave Time Warping-Based Sensing Model for Non-Invasive Personalised Blood Potassium Monitoring in Hemodialysis Patients: A Pilot Study
Background: End-stage renal disease patients undergoing hemodialysis (ESRD-HD) therapy are highly susceptible to malignant ventricular arrhythmias caused by undetected potassium concentration ([]) variations () out of normal ranges. Therefore, a reliable method for continuous, noninvasive monitoring of [] is crucial. The morphology of the T-wave in the electrocardiogram (ECG) reflects and two time-warping-based T-wave morphological parameters, and its heart-rate corrected version , have been shown to reliably track from the ECG. The aim of this study is to derive polynomial models relating and with , and to test their ability to reliably sense and quantify values. Methods: 48-hour Holter ECGs and [] values from six blood samples were collected from 29 ESRD-HD patients. For every patient, and were computed, and linear, quadratic, and cubic fitting models were derived from them. Then, Spearman’s () and Pearson’s (r) correlation coefficients, and the estimation error () between and the corresponding model-estimated values () were calculated. Results and Discussions: Nonlinear models were the most suitable for estimation, rendering higher Pearson’s correlation (median 0.77 0.92) and smaller estimation error (median 0.20 0.43) than the linear model (median 0.76 0.86 and 0.30 0.40), even if similar Spearman’s were found across models (median 0.77 0.83). Conclusion: Results support the use of nonlinear T-wave-based models as sensors in ESRD-HD patients.Open AccessNonlinear T-Wave Time Warping-Based Sensing Model for Non-Invasive Personalised Blood Potassium Monitoring in Hemodialysis Patients: A Pilot Study
Background: End-stage renal disease patients undergoing hemodialysis (ESRD-HD) therapy are highly susceptible to malignant ventricular arrhythmias caused by undetected potassium concentration ([]) variations () out of normal ranges. Therefore, a reliable method for continuous, noninvasive monitoring of [] is crucial. The morphology of the T-wave in the electrocardiogram (ECG) reflects and two time-warping-based T-wave morphological parameters, and its heart-rate corrected version , have been shown to reliably track from the ECG. The aim of this study is to derive polynomial models relating and with , and to test their ability to reliably sense and quantify values. Methods: 48-hour Holter ECGs and [] values from six blood samples were collected from 29 ESRD-HD patients. For every patient, and were computed, and linear, quadratic, and cubic fitting models were derived from them. Then, Spearman’s () and Pearson’s (r) correlation coefficients, and the estimation error () between and the corresponding model-estimated values () were calculated. Results and Discussions: Nonlinear models were the most suitable for estimation, rendering higher Pearson’s correlation (median 0.77 0.92) and smaller estimation error (median 0.20 0.43) than the linear model (median 0.76 0.86 and 0.30 0.40), even if similar Spearman’s were found across models (median 0.77 0.83). Conclusion: Results support the use of nonlinear T-wave-based models as sensors in ESRD-HD patients. - Open Access
- 10 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (8) , 2467-2478
Characterization of T Wave Amplitude, Duration and Morphology Changes During Hemodialysis: Relationship With Serum Electrolyte Levels and Heart Rate
Objective: Chronic kidney disease affects more than 10% of the world population. Changes in serum ion concentrations increase the risk for ventricular arrhythmias and sudden cardiac death, particularly in end-stage renal disease (ESRD) patients. We characterized how T wave amplitude, duration and morphology descriptors change with variations in serum levels of potassium and calcium and in heart rate, both in ESRD patients and in simulated ventricular fibers. Methods: Electrocardiogram (ECG) recordings from twenty ESRD patients undergoing hemodialysis (HD) and pseudo-ECGs (pECGs) calculated from twenty-two simulated ventricular fibers at varying transmural heterogeneity levels were processed to quantify T wave width ( ${\rm T_{w}}$ ), T wave slope-to-amplitude ratio ( ${\rm T_{S/A}}$ ) and four indices of T wave morphological variability based on time warping ( ${\rm d_{w}, d_{w}^{NL},d_{a}\ and\ d_{a}^{NL}}$ ). Serum potassium and calcium levels and heart rate were measured along HD. Results: ${\rm d_{w}^{NL}}$ was the marker most strongly correlated with serum potassium, ${\rm d_{w}}$ with calcium and ${\rm d_{a}}$ with heart rate, after correction for covariates. Median values of partial correlation coefficients were 0.75, -0.74 and -0.90, respectively. For all analyzed T wave descriptors, high inter-patient variability was observed in the pattern of such relationships. This variability, accentuated during the first HD time points, was reproduced in the simulations and shown to be influenced by differences in transmural heterogeneity. Conclusion: Changes in serum potassium and calcium levels and in heart rate have markable effects on T wave descriptors, particularly those quantifying morphological variability. Significance: ECG markers have the potential to be used for monitoring serum ion concentrations in ESRD patients.- 10 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (8) , 2467-2478
Open AccessCharacterization of T Wave Amplitude, Duration and Morphology Changes During Hemodialysis: Relationship With Serum Electrolyte Levels and Heart Rate
Objective: Chronic kidney disease affects more than 10% of the world population. Changes in serum ion concentrations increase the risk for ventricular arrhythmias and sudden cardiac death, particularly in end-stage renal disease (ESRD) patients. We characterized how T wave amplitude, duration and morphology descriptors change with variations in serum levels of potassium and calcium and in heart rate, both in ESRD patients and in simulated ventricular fibers. Methods: Electrocardiogram (ECG) recordings from twenty ESRD patients undergoing hemodialysis (HD) and pseudo-ECGs (pECGs) calculated from twenty-two simulated ventricular fibers at varying transmural heterogeneity levels were processed to quantify T wave width ( ${\rm T_{w}}$ ), T wave slope-to-amplitude ratio ( ${\rm T_{S/A}}$ ) and four indices of T wave morphological variability based on time warping ( ${\rm d_{w}, d_{w}^{NL},d_{a}\ and\ d_{a}^{NL}}$ ). Serum potassium and calcium levels and heart rate were measured along HD. Results: ${\rm d_{w}^{NL}}$ was the marker most strongly correlated with serum potassium, ${\rm d_{w}}$ with calcium and ${\rm d_{a}}$ with heart rate, after correction for covariates. Median values of partial correlation coefficients were 0.75, -0.74 and -0.90, respectively. For all analyzed T wave descriptors, high inter-patient variability was observed in the pattern of such relationships. This variability, accentuated during the first HD time points, was reproduced in the simulations and shown to be influenced by differences in transmural heterogeneity. Conclusion: Changes in serum potassium and calcium levels and in heart rate have markable effects on T wave descriptors, particularly those quantifying morphological variability. Significance: ECG markers have the potential to be used for monitoring serum ion concentrations in ESRD patients.