Yoshie Otake
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yoshie Otake has a total of 122 co-authors. Here are the top co-authors by number of shared publications:
- Mingfei Yan
School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an, China
4 shared publications - Masato Takamura
RIKEN Center for Advanced Photonics, RIKEN, Japan
3 shared publications - Yasuo Wakabayashi
RIKEN Center for Advanced Photonics, Neutron Beam Technology Team, Wako, Saitama, Japan
3 shared publications Yujiro Ikeda
Center for Advanced Photonics, RIKEN, Wako, Saitama, Japan
3 shared publications- Atsushi Taketani
RIKEN Center for Advanced Photonics, RIKEN
2 shared publications - Chihiro Iwamoto
Center for Advanced Photonics, RIKEN, Wako, Saitama, Japan
2 shared publications
Latest Publications
- 17 November 2025
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 58 (6) , 2066-2077
Time-of-flight small-angle neutron scattering instrument ib -SAS at the compact accelerator-based neutron source RANS, dedicated to education and industrial use
We report the construction and performance of the small-angle neutron scattering instrument ib -SAS at the compact accelerator-based neutron source RANS, RIKEN, Wako, Japan. With this instrument, we aim to increase the opportunities for using neutrons for university education and/or industrial use ( e.g. screening for inferior goods). A time-of-flight method, combined with pulsed neutrons with a wide wavelength band from 1 to 10 Å, is necessary to compensate for the weak luminescence of the compact neutron source. Further enhancement has been achieved by employing a multi-pinhole collimator as a converging-beam device; 81 (= 9 × 9) pinholes select thermal neutrons emitted from the large surface area of a solid polyethylene (PE) moderator and produce a focused beam on the detector. To reduce the background originating from stray neutrons in the beam hall of RANS, we keep the path of small-angle scattering in a vacuum and cover it by a thick shield of Cd plates and PE blocks containing B 4 C powder. To cover a wide range of length scales d [or wavenumber q (= 2π/ d )], three detector blocks (small-angle, wide-angle and backward scattering) were installed on the ib -SAS instrument. The small-angle scattering obtained for glassy carbon and sodium dodecyl sulfate micelle solutions is quantitatively compared with that obtained from the iMATERIA instrument (BL20) at J-PARC, Tokai, with respect to the covered q range and the measurement efficiency and statistics. Similarly to scanning electron microscopy, the SANS instrument at RANS was used to provide a map image showing the water distribution in a mortar plate, the bottom of which was immersed in water. The incoherent scattering from hydrogen was determined and plotted as a function of height.
- 17 November 2025
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 58 (6) , 2066-2077
Time-of-flight small-angle neutron scattering instrument ib -SAS at the compact accelerator-based neutron source RANS, dedicated to education and industrial use
We report the construction and performance of the small-angle neutron scattering instrument ib -SAS at the compact accelerator-based neutron source RANS, RIKEN, Wako, Japan. With this instrument, we aim to increase the opportunities for using neutrons for university education and/or industrial use ( e.g. screening for inferior goods). A time-of-flight method, combined with pulsed neutrons with a wide wavelength band from 1 to 10 Å, is necessary to compensate for the weak luminescence of the compact neutron source. Further enhancement has been achieved by employing a multi-pinhole collimator as a converging-beam device; 81 (= 9 × 9) pinholes select thermal neutrons emitted from the large surface area of a solid polyethylene (PE) moderator and produce a focused beam on the detector. To reduce the background originating from stray neutrons in the beam hall of RANS, we keep the path of small-angle scattering in a vacuum and cover it by a thick shield of Cd plates and PE blocks containing B 4 C powder. To cover a wide range of length scales d [or wavenumber q (= 2π/ d )], three detector blocks (small-angle, wide-angle and backward scattering) were installed on the ib -SAS instrument. The small-angle scattering obtained for glassy carbon and sodium dodecyl sulfate micelle solutions is quantitatively compared with that obtained from the iMATERIA instrument (BL20) at J-PARC, Tokai, with respect to the covered q range and the measurement efficiency and statistics. Similarly to scanning electron microscopy, the SANS instrument at RANS was used to provide a map image showing the water distribution in a mortar plate, the bottom of which was immersed in water. The incoherent scattering from hydrogen was determined and plotted as a function of height.
- Open Access
- 15 November 2023
- Published by Japan Radioisotope Association in RADIOISOTOPES
- Vol. 72 (3) , 267-279
理研小型中性子源システムRANSプロジェクト
理化学研究所では,産業利用の現場における評価解析装置システムとして,さらに社会インフラを検査する屋外利用可能な可搬型計測システムとして広く利用されることを目標とし,小型中性子源システムRANS, RANS-II, RANS-III, RANS-µを開発している。多様なニーズに的確に対応するため,中性子源をさらに小型化,軽量化しながらも,中性子線の高い透過能と分解能を活かした高度な計測が実現しつつある。
- 15 November 2023
- Published by Japan Radioisotope Association in RADIOISOTOPES
- Vol. 72 (3) , 267-279
Open Access理研小型中性子源システムRANSプロジェクト
理化学研究所では,産業利用の現場における評価解析装置システムとして,さらに社会インフラを検査する屋外利用可能な可搬型計測システムとして広く利用されることを目標とし,小型中性子源システムRANS, RANS-II, RANS-III, RANS-µを開発している。多様なニーズに的確に対応するため,中性子源をさらに小型化,軽量化しながらも,中性子線の高い透過能と分解能を活かした高度な計測が実現しつつある。
- 13 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (11) , 2397-2405
Experimental Verifications for a Multiobjective Shielding Design Method on a p-Be Neutron Source With Injection of 7 MeV Protons
NSGA-MC as a multi-objective shielding design method can optimize the shielding parameters aiming at multiple objectives through evolutionary computations by MCNP calculations and a genetic algorithm, NSGA-II. In our previous study, NSGA-MC has been proven to be effective through simulation results by applying to the target shielding design of a compact accelerator-driven neutron source. However, to confirm the effectiveness of NSGA-MC, experimental verifications are critically important. Thus, we planned to experimentally study sets of multi-layer shielding structures consisting of PE, B4C and Pb layers and optimize with NSGA-MC with two objectives of equivalent dose rate and material density. Three cases identified from the Pareto fronts obtained by NSGA-MC and a non-optimized case based on RANS target station shielding configuration were tested by utilizing RIKEN Accelerator-driven compact Neutron Source (RANS). The dose rates of neutron and gamma-ray after neutron beam penetrated the shielding material were measured with commercially available neutron and gamma-ray dosimeters based on these shielding configurations. Discussions were made on experimental results and simulation results. Validation was assured by this experiment within 42%.
- 13 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (11) , 2397-2405
Experimental Verifications for a Multiobjective Shielding Design Method on a p-Be Neutron Source With Injection of 7 MeV Protons
NSGA-MC as a multi-objective shielding design method can optimize the shielding parameters aiming at multiple objectives through evolutionary computations by MCNP calculations and a genetic algorithm, NSGA-II. In our previous study, NSGA-MC has been proven to be effective through simulation results by applying to the target shielding design of a compact accelerator-driven neutron source. However, to confirm the effectiveness of NSGA-MC, experimental verifications are critically important. Thus, we planned to experimentally study sets of multi-layer shielding structures consisting of PE, B4C and Pb layers and optimize with NSGA-MC with two objectives of equivalent dose rate and material density. Three cases identified from the Pareto fronts obtained by NSGA-MC and a non-optimized case based on RANS target station shielding configuration were tested by utilizing RIKEN Accelerator-driven compact Neutron Source (RANS). The dose rates of neutron and gamma-ray after neutron beam penetrated the shielding material were measured with commercially available neutron and gamma-ray dosimeters based on these shielding configurations. Discussions were made on experimental results and simulation results. Validation was assured by this experiment within 42%.
- 18 January 2023
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 24 (3-4) , 411-419
Development of the neutron salt-meter RANS-μ for non-destructive inspection of concrete structure at on-site use
We have started the development of a transportable neutron salt-meter, we call it RANS-μ, combining a 252Cf neutron source and a prompt gamma neutron activation analysis. Trials of chloride detection measurement with RANS-μ were performed outdoor using removed bridges damaged by chloride attack at an outdoor yard in Public Works Research Institute (PWRI) and a test bridge in Fukushima Robot Test Field. For the measurement at PWRI, the results obtained by RANS-μ were compared with those of the automatic potentiometric titration by drilled powder, and then consistent results were obtained.
- 18 January 2023
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 24 (3-4) , 411-419
Development of the neutron salt-meter RANS-μ for non-destructive inspection of concrete structure at on-site use
We have started the development of a transportable neutron salt-meter, we call it RANS-μ, combining a 252Cf neutron source and a prompt gamma neutron activation analysis. Trials of chloride detection measurement with RANS-μ were performed outdoor using removed bridges damaged by chloride attack at an outdoor yard in Public Works Research Institute (PWRI) and a test bridge in Fukushima Robot Test Field. For the measurement at PWRI, the results obtained by RANS-μ were compared with those of the automatic potentiometric titration by drilled powder, and then consistent results were obtained.
- Open Access
- 23 December 2022
- Published by MDPI AG in Nanomaterials
- Vol. 13 (1) , 76
New Material Exploration to Enhance Neutron Intensity below Cold Neutrons: Nanosized Graphene Flower Aggregation
It is proposed that nanosized graphene aggregation could facilitate coherent neutron scattering under particle size conditions similar to nanodiamonds to enhance neutron intensity below cold neutrons. Using the RIKEN accelerator-driven compact neutron source and iMATERIA at J-PARC, we performed neutron measurement experiments, total neutron cross-section and small-angle neutron scattering on nanosized graphene aggregation. For the first time, the measured data revealed that nanosized graphene aggregation increased the total neutron cross-sections and small-angle scattering in the cold neutron energy region. This is most likely due to coherent scattering, resulting in higher neutron intensities, similar to nanodiamonds.
- 23 December 2022
- Published by MDPI AG in Nanomaterials
- Vol. 13 (1) , 76
Open AccessNew Material Exploration to Enhance Neutron Intensity below Cold Neutrons: Nanosized Graphene Flower Aggregation
It is proposed that nanosized graphene aggregation could facilitate coherent neutron scattering under particle size conditions similar to nanodiamonds to enhance neutron intensity below cold neutrons. Using the RIKEN accelerator-driven compact neutron source and iMATERIA at J-PARC, we performed neutron measurement experiments, total neutron cross-section and small-angle neutron scattering on nanosized graphene aggregation. For the first time, the measured data revealed that nanosized graphene aggregation increased the total neutron cross-sections and small-angle scattering in the cold neutron energy region. This is most likely due to coherent scattering, resulting in higher neutron intensities, similar to nanodiamonds.
- Open Access
- 1 June 2022
- Published by MDPI AG in Quantum Beam Science
- Vol. 6 (2) , 22
Demonstration of Neutron Phase Imaging Based on Talbot–Lau Interferometer at Compact Neutron Source RANS
Neutron imaging based on a compact Talbot–Lau interferometer was demonstrated using the RIKEN accelerator-driven compact neutron source (RANS). A compact Talbot–Lau interferometer consisting of gadolinium absorption gratings and a silicon phase grating was constructed and connected to the RANS. Because of pulsed thermal neutrons from the RANS and a position-sensitive detector equipped with time-of-flight (TOF) analysis, moiré interference patterns generated using the interferometer were extracted at a TOF range around the design wavelength (2.37 Å) optimal for the interferometer. Differential phase and scattering images of the metal rod samples were obtained through phase-stepping measurements with the interferometer. This demonstrates the feasibility of neutron phase imaging using a compact neutron facility and the potential for flexible and unique applications for nondestructive evaluation.
- 1 June 2022
- Published by MDPI AG in Quantum Beam Science
- Vol. 6 (2) , 22
Open AccessDemonstration of Neutron Phase Imaging Based on Talbot–Lau Interferometer at Compact Neutron Source RANS
Neutron imaging based on a compact Talbot–Lau interferometer was demonstrated using the RIKEN accelerator-driven compact neutron source (RANS). A compact Talbot–Lau interferometer consisting of gadolinium absorption gratings and a silicon phase grating was constructed and connected to the RANS. Because of pulsed thermal neutrons from the RANS and a position-sensitive detector equipped with time-of-flight (TOF) analysis, moiré interference patterns generated using the interferometer were extracted at a TOF range around the design wavelength (2.37 Å) optimal for the interferometer. Differential phase and scattering images of the metal rod samples were obtained through phase-stepping measurements with the interferometer. This demonstrates the feasibility of neutron phase imaging using a compact neutron facility and the potential for flexible and unique applications for nondestructive evaluation.
- Open Access
- 1 January 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (1) , 013304
Neutron flat-panel detector using In–Ga–Zn–O thin-film transistor
Neutron imaging is a powerful tool for observing the internal structure of an object without destroying the object. Neutron imaging (neutron radiography) is a prominent application of neutrons but still requires significant improvements, for example, in sensitivity, resolution, radiation hardness, and handling of neutron imaging detectors. This paper presents the development and the first neutron imaging results of a neutron flat-panel detector (nFPD) based on an In–Ga–Zn–O (IGZO) thin-film transistor (TFT)/photodiode array coupled with a LiF/ZnS scintillator sheet. Direct photo-coupling to the scintillator increases the light collection efficiency. Moreover, unlike lens-coupled neutron cameras, the proposed detector is compact and easy to handle. Owing to the high off-state resistance of IGZO TFTs, their leakage current is lower than that of conventional TFTs, enabling the IGZO TFTs to hold an accumulated charge for a longer period of time and allowing longer exposure times for imaging. This would be a powerful feature for imaging at compact neutron sources with limited flux. This paper reports on the first neutron imaging results with an IGZO nFPD, its performance evaluation, and a demonstration of three-dimensional computed tomography with neutrons.
- 1 January 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (1) , 013304
Open AccessNeutron flat-panel detector using In–Ga–Zn–O thin-film transistor
Neutron imaging is a powerful tool for observing the internal structure of an object without destroying the object. Neutron imaging (neutron radiography) is a prominent application of neutrons but still requires significant improvements, for example, in sensitivity, resolution, radiation hardness, and handling of neutron imaging detectors. This paper presents the development and the first neutron imaging results of a neutron flat-panel detector (nFPD) based on an In–Ga–Zn–O (IGZO) thin-film transistor (TFT)/photodiode array coupled with a LiF/ZnS scintillator sheet. Direct photo-coupling to the scintillator increases the light collection efficiency. Moreover, unlike lens-coupled neutron cameras, the proposed detector is compact and easy to handle. Owing to the high off-state resistance of IGZO TFTs, their leakage current is lower than that of conventional TFTs, enabling the IGZO TFTs to hold an accumulated charge for a longer period of time and allowing longer exposure times for imaging. This would be a powerful feature for imaging at compact neutron sources with limited flux. This paper reports on the first neutron imaging results with an IGZO nFPD, its performance evaluation, and a demonstration of three-dimensional computed tomography with neutrons.
- 27 September 2021
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 23 (2-3) , 119-125
RIKEN Accelerator-driven compact Neutron systems, RANS project -RANS, RANS-II, III, RANS-μ-
RIKEN Accelerator-driven compact neutron source, RANS, has been operational since 2013. There are two major goals of RANS research and development. One is to establish a new compact low energy neutron non-destructive evaluation system on-site of floor-standing type for industrial use. Another goal is to invent a novel transportable compact neutron system for the preventive maintenance of large scale construction such as a bridge. For the realization of the preventive maintenance usage with neutron methods for non-destructive test of large scale structures on-site, “Standardization”, such as inclusion in manuals and inspection procedures, is essential. Technology research association for the infrastructure preventive maintenance standardization is established. RANS and RANS-II are in operation, and RANS-III, and RANS-μ, neutron salt-meter, are under development.
- 27 September 2021
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 23 (2-3) , 119-125
RIKEN Accelerator-driven compact Neutron systems, RANS project -RANS, RANS-II, III, RANS-μ-
RIKEN Accelerator-driven compact neutron source, RANS, has been operational since 2013. There are two major goals of RANS research and development. One is to establish a new compact low energy neutron non-destructive evaluation system on-site of floor-standing type for industrial use. Another goal is to invent a novel transportable compact neutron system for the preventive maintenance of large scale construction such as a bridge. For the realization of the preventive maintenance usage with neutron methods for non-destructive test of large scale structures on-site, “Standardization”, such as inclusion in manuals and inspection procedures, is essential. Technology research association for the infrastructure preventive maintenance standardization is established. RANS and RANS-II are in operation, and RANS-III, and RANS-μ, neutron salt-meter, are under development.
- 27 September 2021
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 23 (2-3) , 207-213
Conceptual study of salt-meter with 252Cf neutron source for on-site inspection of bridge structure
We studied the feasibility of a portable salt-meter incorporating a prompt gamma neutron activation analysis with a californium-252 neutron source to meet urgent demands for non-destructive methods without pre-processing in large bulk materials such as concrete structures. This technique is aiming at the chloride ion concentration in concrete structures with a depth profile from the surface to steel bar. From the portability point of view, a californium-252 neutron source is adopted and we have performed a preliminary experiment and simulations with a simple geometry. In this paper, we describe the performances of salt detection sensitivities by applying the prompt gamma neutron activation analysis.
- 27 September 2021
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 23 (2-3) , 207-213
Conceptual study of salt-meter with 252Cf neutron source for on-site inspection of bridge structure
We studied the feasibility of a portable salt-meter incorporating a prompt gamma neutron activation analysis with a californium-252 neutron source to meet urgent demands for non-destructive methods without pre-processing in large bulk materials such as concrete structures. This technique is aiming at the chloride ion concentration in concrete structures with a depth profile from the surface to steel bar. From the portability point of view, a californium-252 neutron source is adopted and we have performed a preliminary experiment and simulations with a simple geometry. In this paper, we describe the performances of salt detection sensitivities by applying the prompt gamma neutron activation analysis.
- 12 April 2021
- Published by American Physical Society (APS) in Physical Review C
- Vol. 103 (4) , 044001
Proton- elastic scattering at intermediate energiesWe present a precise measurement of the cross section, proton and analyzing powers, and spin correlation coefficient for elastic scattering near 65 MeV, and a comparison with rigorous four-nucleon scattering calculations based on realistic nuclear potentials and a model with -isobar excitation. Clear discrepancies are seen in some of the measured observables in the regime around the cross section minimum. Theoretical predictions using scaling relations between the calculated cross section and the binding energy are not successful in reproducing the data. Large sensitivity to the potentials and rather small -isobar effects in the calculated cross section are noticed as different features from those in the deuteron-proton elastic scattering. The results obtained above indicate that scattering at intermediate energies is an excellent tool to explore nuclear interactions not accessible by three-nucleon scattering.- 12 April 2021
- Published by American Physical Society (APS) in Physical Review C
- Vol. 103 (4) , 044001
Proton- elastic scattering at intermediate energiesWe present a precise measurement of the cross section, proton and analyzing powers, and spin correlation coefficient for elastic scattering near 65 MeV, and a comparison with rigorous four-nucleon scattering calculations based on realistic nuclear potentials and a model with -isobar excitation. Clear discrepancies are seen in some of the measured observables in the regime around the cross section minimum. Theoretical predictions using scaling relations between the calculated cross section and the binding energy are not successful in reproducing the data. Large sensitivity to the potentials and rather small -isobar effects in the calculated cross section are noticed as different features from those in the deuteron-proton elastic scattering. The results obtained above indicate that scattering at intermediate energies is an excellent tool to explore nuclear interactions not accessible by three-nucleon scattering.