Chihiro Iwamoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chihiro Iwamoto has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Atsushi Taketani
RIKEN Center for Advanced Photonics, RIKEN
3 shared publications - Takaoki Takanashi
RIKEN RAP, 2-1 Hirosawa Wako, Japan
2 shared publications - Yoshie Otake
RIKEN Center for Advanced Photonics, RIKEN, Wako-shi, Saitama, Japan
2 shared publications - Atsushi Momose
Tohoku Univ, Inst Multidisciplinary Res Adv Mat, 2-1-1 Katahira,Aoba Ku, Sendai 9808577, Japan
1 shared publication - Baolong Ma
School of Nuclear Science and Technology & Shaanxi Engineering Research Center of Advanced Nuclear Energy & Shaanxi Key Laboratory of Advanced Nuclear Energy and Technology & School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, Shaanxi
1 shared publication Daisuke Suzuki
RIKEN Nishina Center , RIKEN, Wako, Saitama, Japan
1 shared publication
Latest Publications
- 13 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (11) , 2397-2405
Experimental Verifications for a Multiobjective Shielding Design Method on a p-Be Neutron Source With Injection of 7 MeV Protons
NSGA-MC as a multi-objective shielding design method can optimize the shielding parameters aiming at multiple objectives through evolutionary computations by MCNP calculations and a genetic algorithm, NSGA-II. In our previous study, NSGA-MC has been proven to be effective through simulation results by applying to the target shielding design of a compact accelerator-driven neutron source. However, to confirm the effectiveness of NSGA-MC, experimental verifications are critically important. Thus, we planned to experimentally study sets of multi-layer shielding structures consisting of PE, B4C and Pb layers and optimize with NSGA-MC with two objectives of equivalent dose rate and material density. Three cases identified from the Pareto fronts obtained by NSGA-MC and a non-optimized case based on RANS target station shielding configuration were tested by utilizing RIKEN Accelerator-driven compact Neutron Source (RANS). The dose rates of neutron and gamma-ray after neutron beam penetrated the shielding material were measured with commercially available neutron and gamma-ray dosimeters based on these shielding configurations. Discussions were made on experimental results and simulation results. Validation was assured by this experiment within 42%.
- 13 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (11) , 2397-2405
Experimental Verifications for a Multiobjective Shielding Design Method on a p-Be Neutron Source With Injection of 7 MeV Protons
NSGA-MC as a multi-objective shielding design method can optimize the shielding parameters aiming at multiple objectives through evolutionary computations by MCNP calculations and a genetic algorithm, NSGA-II. In our previous study, NSGA-MC has been proven to be effective through simulation results by applying to the target shielding design of a compact accelerator-driven neutron source. However, to confirm the effectiveness of NSGA-MC, experimental verifications are critically important. Thus, we planned to experimentally study sets of multi-layer shielding structures consisting of PE, B4C and Pb layers and optimize with NSGA-MC with two objectives of equivalent dose rate and material density. Three cases identified from the Pareto fronts obtained by NSGA-MC and a non-optimized case based on RANS target station shielding configuration were tested by utilizing RIKEN Accelerator-driven compact Neutron Source (RANS). The dose rates of neutron and gamma-ray after neutron beam penetrated the shielding material were measured with commercially available neutron and gamma-ray dosimeters based on these shielding configurations. Discussions were made on experimental results and simulation results. Validation was assured by this experiment within 42%.
- Open Access
- 12 July 2023
- Published by Oxford University Press (OUP) in Progress of Theoretical and Experimental Physics
- Vol. 2023 (8)
Performance of prototype dual gain multilayer thick gas electron multiplier with high-intensity heavy-ion beam injections in low-pressure hydrogen gas
A prototype Dual Gain Multilayer Thick Gas Electron Multiplier (DG-M-THGEM) with an active area of 10 cm × 10 cm was manufactured aiming at the production of a large-volume active-target time projection chamber which can work under the condition of high-intensity heavy-ion beam injections. The DG-M-THGEM has an alternating structure of electrodes and insulators. Effective gas gains of two regions, which are called beam and recoil regions, are separately controlled. Performance of the prototype DG-M-THGEM in hydrogen gas at a pressure of 40 kPa was evaluated. Irradiating a 132Xe beam, an effective gas gain lower than 100 with a charge resolution of 3% was achieved in the beam region while the effective gas gain of 2000 was maintained in the recoil region. Position distributions of measured charges along the beam axis were investigated in order to evaluate gain uniformity in the high intensity beam injection. The gain shift was estimated by simulations considering space charges in the drift region. The gain shift was suppressed within 3% even at the beam intensity of 2.5 × 106 particles per second.
- 12 July 2023
- Published by Oxford University Press (OUP) in Progress of Theoretical and Experimental Physics
- Vol. 2023 (8)
Open AccessPerformance of prototype dual gain multilayer thick gas electron multiplier with high-intensity heavy-ion beam injections in low-pressure hydrogen gas
A prototype Dual Gain Multilayer Thick Gas Electron Multiplier (DG-M-THGEM) with an active area of 10 cm × 10 cm was manufactured aiming at the production of a large-volume active-target time projection chamber which can work under the condition of high-intensity heavy-ion beam injections. The DG-M-THGEM has an alternating structure of electrodes and insulators. Effective gas gains of two regions, which are called beam and recoil regions, are separately controlled. Performance of the prototype DG-M-THGEM in hydrogen gas at a pressure of 40 kPa was evaluated. Irradiating a 132Xe beam, an effective gas gain lower than 100 with a charge resolution of 3% was achieved in the beam region while the effective gas gain of 2000 was maintained in the recoil region. Position distributions of measured charges along the beam axis were investigated in order to evaluate gain uniformity in the high intensity beam injection. The gain shift was estimated by simulations considering space charges in the drift region. The gain shift was suppressed within 3% even at the beam intensity of 2.5 × 106 particles per second.
- 18 January 2023
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 24 (3-4) , 421-426
Sample-motion-synchronized neutron stroboscope at RANS
A sample-motion-synchronized neutron stroboscope is developed using the RIKEN accelerator-based compact neutron source (RANS). When a sample reaches a specified rotation phase, a phase timing signal is generated, triggering a proton pulse at the proton accelerator. A neutron pulse exposes the imaging detector through the sample. By controlling the delay time between the phase signal and the proton pulse timing, the neutron exposure timing is always synchronized with the specific sample rotation phase. A sample rotating at a speed of 1800 RPM is prepared, and clear still images of neutrons are taken.
- 18 January 2023
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 24 (3-4) , 421-426
Sample-motion-synchronized neutron stroboscope at RANS
A sample-motion-synchronized neutron stroboscope is developed using the RIKEN accelerator-based compact neutron source (RANS). When a sample reaches a specified rotation phase, a phase timing signal is generated, triggering a proton pulse at the proton accelerator. A neutron pulse exposes the imaging detector through the sample. By controlling the delay time between the phase signal and the proton pulse timing, the neutron exposure timing is always synchronized with the specific sample rotation phase. A sample rotating at a speed of 1800 RPM is prepared, and clear still images of neutrons are taken.
- Open Access
- 1 June 2022
- Published by MDPI AG in Quantum Beam Science
- Vol. 6 (2) , 22
Demonstration of Neutron Phase Imaging Based on Talbot–Lau Interferometer at Compact Neutron Source RANS
Neutron imaging based on a compact Talbot–Lau interferometer was demonstrated using the RIKEN accelerator-driven compact neutron source (RANS). A compact Talbot–Lau interferometer consisting of gadolinium absorption gratings and a silicon phase grating was constructed and connected to the RANS. Because of pulsed thermal neutrons from the RANS and a position-sensitive detector equipped with time-of-flight (TOF) analysis, moiré interference patterns generated using the interferometer were extracted at a TOF range around the design wavelength (2.37 Å) optimal for the interferometer. Differential phase and scattering images of the metal rod samples were obtained through phase-stepping measurements with the interferometer. This demonstrates the feasibility of neutron phase imaging using a compact neutron facility and the potential for flexible and unique applications for nondestructive evaluation.
- 1 June 2022
- Published by MDPI AG in Quantum Beam Science
- Vol. 6 (2) , 22
Open AccessDemonstration of Neutron Phase Imaging Based on Talbot–Lau Interferometer at Compact Neutron Source RANS
Neutron imaging based on a compact Talbot–Lau interferometer was demonstrated using the RIKEN accelerator-driven compact neutron source (RANS). A compact Talbot–Lau interferometer consisting of gadolinium absorption gratings and a silicon phase grating was constructed and connected to the RANS. Because of pulsed thermal neutrons from the RANS and a position-sensitive detector equipped with time-of-flight (TOF) analysis, moiré interference patterns generated using the interferometer were extracted at a TOF range around the design wavelength (2.37 Å) optimal for the interferometer. Differential phase and scattering images of the metal rod samples were obtained through phase-stepping measurements with the interferometer. This demonstrates the feasibility of neutron phase imaging using a compact neutron facility and the potential for flexible and unique applications for nondestructive evaluation.
- Open Access
- 15 May 2022
- Published by Iron and Steel Institute of Japan in ISIJ International
- Vol. 62 (5) , 1013-1022
Improvement of Neutron Diffraction at Compact Accelerator-driven Neutron Source RANS Using Peak Profile Deconvolution and Delayed Neutron Reduction for Stress Measurements
Neutron diffraction is a powerful non-destructive method for evaluating the microscopic structure and internal stress of metal plates as a bulk average. Precise neutron diffraction measurements with a high-intensity neutron beam have already been carried out at large-scale neutron facilities. However, it is not easy to provide users with enough experimental opportunities. We are working on upgrading the neutron diffractometer with techniques of time-of-flight to enable stress measurements at RIKEN accelerator-driven compact neutron source (RANS). To improve neutron diffraction resolution, delayed neutrons, which expand neutron beam pulse width, should be suppressed. However, it is difficult to separate the delayed neutrons experimentally. In this study, a new analysis method has been proposed to deconvolute the diffraction peak from the delayed neutron component. Moreover, a new collimator system, called decoupled collimator system, has been developed to reduce the number of delayed neutrons. The diffraction patterns from a powder sample of pure body-centered cubic iron were measured with the decoupled collimator and the diffraction peak of {211} reflection was analyzed by the new analysis method using a model function of a single exponential decay function convoluted with a Gaussian function. By this method, the decoupled collimator system has been confirmed to achieve a smaller measurement limit of lattice strain Δε than a small-aperture polyethylene collimator system and a non-collimator system. The currently available Δε was 6.7×10−4, this means that the internal stress up to 130 MPa can be well evaluated for steel materials with a Young’s modulus of 200 GPa at RANS.
- 15 May 2022
- Published by Iron and Steel Institute of Japan in ISIJ International
- Vol. 62 (5) , 1013-1022
Open AccessImprovement of Neutron Diffraction at Compact Accelerator-driven Neutron Source RANS Using Peak Profile Deconvolution and Delayed Neutron Reduction for Stress Measurements
Neutron diffraction is a powerful non-destructive method for evaluating the microscopic structure and internal stress of metal plates as a bulk average. Precise neutron diffraction measurements with a high-intensity neutron beam have already been carried out at large-scale neutron facilities. However, it is not easy to provide users with enough experimental opportunities. We are working on upgrading the neutron diffractometer with techniques of time-of-flight to enable stress measurements at RIKEN accelerator-driven compact neutron source (RANS). To improve neutron diffraction resolution, delayed neutrons, which expand neutron beam pulse width, should be suppressed. However, it is difficult to separate the delayed neutrons experimentally. In this study, a new analysis method has been proposed to deconvolute the diffraction peak from the delayed neutron component. Moreover, a new collimator system, called decoupled collimator system, has been developed to reduce the number of delayed neutrons. The diffraction patterns from a powder sample of pure body-centered cubic iron were measured with the decoupled collimator and the diffraction peak of {211} reflection was analyzed by the new analysis method using a model function of a single exponential decay function convoluted with a Gaussian function. By this method, the decoupled collimator system has been confirmed to achieve a smaller measurement limit of lattice strain Δε than a small-aperture polyethylene collimator system and a non-collimator system. The currently available Δε was 6.7×10−4, this means that the internal stress up to 130 MPa can be well evaluated for steel materials with a Young’s modulus of 200 GPa at RANS.