Shunsuke Shibata
Research Subjects
Research Interests
Shunsuke Shibata has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Goro Ueda
DENSO CORPORATION, Kariya, Aichi 448-8661, Japan
1 shared publication - Hiroyuki Mori
SOKEN, INC., Nisshin, Aichi 470-0111, Japan
1 shared publication - Jianqing Wang
Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya, Japan
1 shared publication - Kazutaka Mitsui
Nagoya Institute of Technology, Nagoya 466-8555, Japan
1 shared publication - Takashi Saito
SOKEN, INC., Nisshin, Aichi 470-0111, Japan
1 shared publication - Yang Zheng
College of Mechatronic Engineering and Automation, Shanghai University, Shanghai, China
1 shared publication
Latest Publications
- Open Access
Non-Contact Heart-Rate Measurement Method Using Both Transmitted Wave Extraction and Wavelet Transform
Continuous monitoring of heart-rate is expected to lead to early detection of physical discomfort. In this study, we propose a non-contact heart-rate measurement method which can be used in an environment such as driver heart-rate monitoring with body movement. The method is based on the electric field strength transmitted through the human body that changes with the diastole and systole of the heart. Unlike conventional displacement detection of the skin surface, we attempted to capture changes in the internal structure of the human body by irradiating the human body with microwaves and acquiring microwaves that pass through the heart. We first estimated the electric field strength transmitted through the heart using three receiving sensors to reduce the body movement effect. Then we decomposed the estimated transmitted electric field using stationary wavelet transform to eliminate significant distortion due to body movement. As a result, we achieved an estimation accuracy of heart-rate as high as 98% in a verification experiment with normal body movement.
Open AccessNon-Contact Heart-Rate Measurement Method Using Both Transmitted Wave Extraction and Wavelet Transform
Continuous monitoring of heart-rate is expected to lead to early detection of physical discomfort. In this study, we propose a non-contact heart-rate measurement method which can be used in an environment such as driver heart-rate monitoring with body movement. The method is based on the electric field strength transmitted through the human body that changes with the diastole and systole of the heart. Unlike conventional displacement detection of the skin surface, we attempted to capture changes in the internal structure of the human body by irradiating the human body with microwaves and acquiring microwaves that pass through the heart. We first estimated the electric field strength transmitted through the heart using three receiving sensors to reduce the body movement effect. Then we decomposed the estimated transmitted electric field using stationary wavelet transform to eliminate significant distortion due to body movement. As a result, we achieved an estimation accuracy of heart-rate as high as 98% in a verification experiment with normal body movement.