Daniel Kalús
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daniel Kalús has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Daniela Koudelková
Department of Building Services, Faculty of Civil Engineering, Slovak University of Technology, 810 05 Bratislava, Slovakia
7 shared publications - Martin Sokol
Department of Building Services, Faculty of Civil Engineering, Slovak University of Technology, 810 05 Bratislava, Slovakia
6 shared publications - Mária Kurčová
Department of Building Services, Faculty of Civil Engineering, Slovak University of Technology, 810 05 Bratislava, Slovakia
6 shared publications - Patrik Šťastný
Department of Building Technology, Faculty of Civil Engineering, Slovak University of Technology in Bratislava, 810 05 Bratislava, Slovakia
6 shared publications - Zuzana Straková
Department of Building Services, Faculty of Civil Engineering, Slovak University of Technology in Bratislava, Radlinského 11, 810 05 Bratislava, Slovakia
6 shared publications - Mária Füri
Department of Building Services, Faculty of Civil Engineering, Slovak University of Technology in Bratislava, Radlinského 11, 810 05 Bratislava, Slovakia
5 shared publications
Latest Publications
- Open Access
- 9 July 2026
- Published by Elsevier in SSRN Electronic Journal
Experimental Investigation of Hydraulic System Stability in Building Energy Systems with Heat Pumps: Influence of the Hydraulic Design Parameters of Short-Term Thermal Energy Storage
Short-term thermal energy storage is a key hydraulic design element of building energy systems equipped with heat pumps because it directly influences hydraulic system stability, heat pump operational stability, energy efficiency, and building energy flexibility. Despite the widespread application of thermal energy storage tanks, experimental understanding of the interaction between hydraulic design parameters under realistic operating conditions remains limited. Most published studies are based primarily on numerical modelling or control optimisation and investigate individual hydraulic design parameters separately. The objective of the present study was to experimentally investigate hydraulic system stability in building energy systems incorporating heat pumps. To achieve this objective, the influence of storage tank volume, charging direction, and heat-transfer fluid flow rate, considered the principal hydraulic design parameters of short-term thermal energy storage, was systematically investigated. The study was not intended to evaluate the heating or cooling performance of a building. Experimental measurements were performed on a physical model of a building energy system operating in an experimental cold-water production mode. This operating mode was selected exclusively to provide stable, reproducible, and physically representative operating conditions for evaluating hydraulic system stability and should not be interpreted as an investigation of building cooling performance. The influence of storage tank volume, charging direction, and heat-transfer fluid flow rate was systematically evaluated while maintaining all other operating conditions unchanged. The experimental results demonstrated that incorporating short-term thermal energy storage reduced the number of heat pump starts from 20 to 2 during a 12-hour observation period, corresponding to an approximately 90% reduction in cycling frequency. Changing the storage tank charging direction increased the heat pump operating cycle duration by approximately 80%, whereas increasing the storage tank volume from 100 L to 300 L prolonged the operating cycle by approximately 3.5 times. The investigation further demonstrated that the influence of heat-transfer fluid flow rate on the dynamic operation of the system depends on storage tank volume rather than acting as an independent hydraulic design parameter. The principal scientific contribution of this work is the experimental demonstration that the hydraulic design parameters of short-term thermal energy storage do not act independently. Instead, storage tank volume, charging direction, and heat-transfer fluid flow rate constitute an interconnected hydraulic system whose combined interaction determines hydraulic system stability, the thermal response of the hydraulic circuit, the dynamic operation of the heat pump, and its cycling behaviour. The obtained findings provide an experimentally validated foundation for the hydraulic design of building energy systems equipped with heat pumps and support more effective integration of renewable energy sources, enhanced building energy flexibility, and the development of intelligent low-carbon building energy systems contributing to SDG 7 (Affordable and Clean Energy), SDG 11 (Sustainable Cities and Communities), and SDG 13 (Climate Action).
- 9 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessExperimental Investigation of Hydraulic System Stability in Building Energy Systems with Heat Pumps: Influence of the Hydraulic Design Parameters of Short-Term Thermal Energy Storage
Short-term thermal energy storage is a key hydraulic design element of building energy systems equipped with heat pumps because it directly influences hydraulic system stability, heat pump operational stability, energy efficiency, and building energy flexibility. Despite the widespread application of thermal energy storage tanks, experimental understanding of the interaction between hydraulic design parameters under realistic operating conditions remains limited. Most published studies are based primarily on numerical modelling or control optimisation and investigate individual hydraulic design parameters separately. The objective of the present study was to experimentally investigate hydraulic system stability in building energy systems incorporating heat pumps. To achieve this objective, the influence of storage tank volume, charging direction, and heat-transfer fluid flow rate, considered the principal hydraulic design parameters of short-term thermal energy storage, was systematically investigated. The study was not intended to evaluate the heating or cooling performance of a building. Experimental measurements were performed on a physical model of a building energy system operating in an experimental cold-water production mode. This operating mode was selected exclusively to provide stable, reproducible, and physically representative operating conditions for evaluating hydraulic system stability and should not be interpreted as an investigation of building cooling performance. The influence of storage tank volume, charging direction, and heat-transfer fluid flow rate was systematically evaluated while maintaining all other operating conditions unchanged. The experimental results demonstrated that incorporating short-term thermal energy storage reduced the number of heat pump starts from 20 to 2 during a 12-hour observation period, corresponding to an approximately 90% reduction in cycling frequency. Changing the storage tank charging direction increased the heat pump operating cycle duration by approximately 80%, whereas increasing the storage tank volume from 100 L to 300 L prolonged the operating cycle by approximately 3.5 times. The investigation further demonstrated that the influence of heat-transfer fluid flow rate on the dynamic operation of the system depends on storage tank volume rather than acting as an independent hydraulic design parameter. The principal scientific contribution of this work is the experimental demonstration that the hydraulic design parameters of short-term thermal energy storage do not act independently. Instead, storage tank volume, charging direction, and heat-transfer fluid flow rate constitute an interconnected hydraulic system whose combined interaction determines hydraulic system stability, the thermal response of the hydraulic circuit, the dynamic operation of the heat pump, and its cycling behaviour. The obtained findings provide an experimentally validated foundation for the hydraulic design of building energy systems equipped with heat pumps and support more effective integration of renewable energy sources, enhanced building energy flexibility, and the development of intelligent low-carbon building energy systems contributing to SDG 7 (Affordable and Clean Energy), SDG 11 (Sustainable Cities and Communities), and SDG 13 (Climate Action).
- 2 June 2026
- Published by Springer Nature
- p. 148-159
Application of Active Thermal Protection on a Modular Apartment Building with a Lightweight Building Envelope
- 2 June 2026
- Published by Springer Nature
- p. 148-159
Application of Active Thermal Protection on a Modular Apartment Building with a Lightweight Building Envelope
- 22 February 2026
- Published by Springer Nature
- p. 122-141
Digitalisation of the Heat/cooling Source and Combined Building-Energy System at the Experimental Laboratory
- 22 February 2026
- Published by Springer Nature
- p. 122-141
Digitalisation of the Heat/cooling Source and Combined Building-Energy System at the Experimental Laboratory
- Open Access
- 2 September 2025
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 150 (21) , 17637-17660
Analysis, evaluation, and optimisation of the operation of the mechanical ventilation of apartment buildings in terms of energy consumption, economic efficiency, and environmental safety
In this thesis, we present alternative ventilation solutions with heat recovery to reduce energy consumption in apartment buildings: decentralised ventilation compared to local ventilation. The aim is to analyse, evaluate, and optimise the operation of mechanical ventilation. The parametric study of energy, economic, and environmental calculations focuses first on a single apartment and then on the entire apartment building. Local heat recovery units have been designed for the ventilation of the apartment building. The share of heat loss through ventilation is 45% of the total design heat output for heating the building. Considering the UN Sustainable Development Goals, particularly Goal 7 (affordable and clean energy), we evaluated an alternative using decentralised heat recovery units with enthalpy heat exchangers. This approach achieved significant thermal energy savings, covered heat losses due to ventilation, and provided improved air and environmental quality in the apartment building. In this case, the share of ventilation heat losses in the apartment building is only 13% of the total design heat output of the building. The total heat output of the heat source was reduced by almost 78.78 kW, and the energy savings of the decentralised units amounted to 151.30 MWh, a reduction of 44% compared to the local ventilation units. Although the initial investment cost is about 45% higher than for the local units, the return on investment is achieved within 6 years of operation. The proposed solution represents a 58% saving in primary energy for ventilation and an 81% reduction in CO 2 emissions.
- 2 September 2025
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 150 (21) , 17637-17660
Open AccessAnalysis, evaluation, and optimisation of the operation of the mechanical ventilation of apartment buildings in terms of energy consumption, economic efficiency, and environmental safety
In this thesis, we present alternative ventilation solutions with heat recovery to reduce energy consumption in apartment buildings: decentralised ventilation compared to local ventilation. The aim is to analyse, evaluate, and optimise the operation of mechanical ventilation. The parametric study of energy, economic, and environmental calculations focuses first on a single apartment and then on the entire apartment building. Local heat recovery units have been designed for the ventilation of the apartment building. The share of heat loss through ventilation is 45% of the total design heat output for heating the building. Considering the UN Sustainable Development Goals, particularly Goal 7 (affordable and clean energy), we evaluated an alternative using decentralised heat recovery units with enthalpy heat exchangers. This approach achieved significant thermal energy savings, covered heat losses due to ventilation, and provided improved air and environmental quality in the apartment building. In this case, the share of ventilation heat losses in the apartment building is only 13% of the total design heat output of the building. The total heat output of the heat source was reduced by almost 78.78 kW, and the energy savings of the decentralised units amounted to 151.30 MWh, a reduction of 44% compared to the local ventilation units. Although the initial investment cost is about 45% higher than for the local units, the return on investment is achieved within 6 years of operation. The proposed solution represents a 58% saving in primary energy for ventilation and an 81% reduction in CO 2 emissions.
- Open Access
Energy Sustainability, Resilience, and Climate Adaptability of Modular and Panelized Buildings with a Lightweight Envelope Integrating Active Thermal Protection: Part 2—Design and Implementation of an Experimental Prototype of a Building Module for Modular Buildings
The integration of energy-active elements into the building envelope in the form of large-area heating/cooling, active thermal protection (ATP), thermal barriers (TB), and TABS represents a technical solution that is consistent with the principles of energy sustainability, resilience, and adaptability to climate change and ensures affordable and clean energy for all while protecting the climate in the context of the UN Sustainable Development Goals. The aim and innovation of our research is to develop energy multifunctional facades (EMFs) that are capable of performing a dual role, which includes the primary known energy functions of end elements and the additional innovative ability to serve as a source of heat/cooling/electricity. This new function of EMFs will facilitate heat dissipation from overheated facade surfaces, preheating of hot water, and electricity generation for the operation of building energy systems through integrated photovoltaic components. The theoretical assumptions and hypotheses presented in our previous research work must be verified by experimental measurements with predictions of the optimal operation of building energy systems. Most existing studies on thermal barriers are based on calculations. However, there are few empirical measurements that quantify the benefits of ATP in real operation and specify the conditions under which different types of ATP are feasible. In this article, we present the development, design, and implementation of an experimental prototype of a prefabricated building module with integrated energy-active elements. The aim is to fill the knowledge gaps by providing a comprehensive framework that includes the development, research, design, and implementation of combined energy systems for buildings. The design of energy systems will be developed in BIM. An important result of this research is the development of a technological process for the implementation of a contact insulation system with integrated ATP in modular and panel buildings with a lightweight envelope.
Open AccessEnergy Sustainability, Resilience, and Climate Adaptability of Modular and Panelized Buildings with a Lightweight Envelope Integrating Active Thermal Protection: Part 2—Design and Implementation of an Experimental Prototype of a Building Module for Modular Buildings
The integration of energy-active elements into the building envelope in the form of large-area heating/cooling, active thermal protection (ATP), thermal barriers (TB), and TABS represents a technical solution that is consistent with the principles of energy sustainability, resilience, and adaptability to climate change and ensures affordable and clean energy for all while protecting the climate in the context of the UN Sustainable Development Goals. The aim and innovation of our research is to develop energy multifunctional facades (EMFs) that are capable of performing a dual role, which includes the primary known energy functions of end elements and the additional innovative ability to serve as a source of heat/cooling/electricity. This new function of EMFs will facilitate heat dissipation from overheated facade surfaces, preheating of hot water, and electricity generation for the operation of building energy systems through integrated photovoltaic components. The theoretical assumptions and hypotheses presented in our previous research work must be verified by experimental measurements with predictions of the optimal operation of building energy systems. Most existing studies on thermal barriers are based on calculations. However, there are few empirical measurements that quantify the benefits of ATP in real operation and specify the conditions under which different types of ATP are feasible. In this article, we present the development, design, and implementation of an experimental prototype of a prefabricated building module with integrated energy-active elements. The aim is to fill the knowledge gaps by providing a comprehensive framework that includes the development, research, design, and implementation of combined energy systems for buildings. The design of energy systems will be developed in BIM. An important result of this research is the development of a technological process for the implementation of a contact insulation system with integrated ATP in modular and panel buildings with a lightweight envelope.
- Open Access
Energy Sustainability, Resilience, and Climate Adaptability of Modular and Panelized Buildings with a Lightweight Envelope Integrating Active Thermal Protection. Part 1—Parametric Study and Computer Simulation
Modular and prefabricated buildings are advantageous in terms of construction, transport, energy efficiency, fixed costs, and the use of environmentally friendly materials. Our research aims to analyze, evaluate, and optimize a lightweight perimeter structure with an integrated active thermal protection (ATP). We have developed a mathematical–physical model of a wall fragment, in which we have analyzed several variants through a parametric study. ATP in the energy function of a thermal barrier (TB) represents a high potential for energy savings. Cold tap water (an average temperature of +6 °C, thermal untreated) in the ATP layer of the investigated building structure increases its thermal resistance by up to 27.24%. The TB’s mean temperature can be thermally adjusted to a level comparable to the heated space (e.g., +20 °C). For the fragment under consideration, optimizing the axial distance between the pipes (in the ATP layer) and the insulation thickness (using computer simulation) reveals that a pipe distance of 150 mm and an insulation thickness of 100 mm are the most suitable. ATP has significant potential in the design of sustainable, resilient, and climate-adaptive buildings, thereby meeting the UN SDGs, in particular the Sustainable Development Goal 7 ‘Affordable and Clean Energy’ and the Goal 13 ‘Climate Action’.
Open AccessEnergy Sustainability, Resilience, and Climate Adaptability of Modular and Panelized Buildings with a Lightweight Envelope Integrating Active Thermal Protection. Part 1—Parametric Study and Computer Simulation
Modular and prefabricated buildings are advantageous in terms of construction, transport, energy efficiency, fixed costs, and the use of environmentally friendly materials. Our research aims to analyze, evaluate, and optimize a lightweight perimeter structure with an integrated active thermal protection (ATP). We have developed a mathematical–physical model of a wall fragment, in which we have analyzed several variants through a parametric study. ATP in the energy function of a thermal barrier (TB) represents a high potential for energy savings. Cold tap water (an average temperature of +6 °C, thermal untreated) in the ATP layer of the investigated building structure increases its thermal resistance by up to 27.24%. The TB’s mean temperature can be thermally adjusted to a level comparable to the heated space (e.g., +20 °C). For the fragment under consideration, optimizing the axial distance between the pipes (in the ATP layer) and the insulation thickness (using computer simulation) reveals that a pipe distance of 150 mm and an insulation thickness of 100 mm are the most suitable. ATP has significant potential in the design of sustainable, resilient, and climate-adaptive buildings, thereby meeting the UN SDGs, in particular the Sustainable Development Goal 7 ‘Affordable and Clean Energy’ and the Goal 13 ‘Climate Action’.
- Open Access
- 18 July 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (14) , 11187
Implementing the Technologies of Additional Impermeable Layers in a Building of the Monuments Office (Káčerov Majer) from a Sustainability Point of View
This article presents the results of an experiment that involved applying additional impermeable layers on an historical building in the area of Káčerov Majer. The building showed a high level of waterlogging, which was detected by an initial inspection and subsequent moisture measurements that involved taking a set of measurements and recording the data in a spreadsheet linked to the plan view of the building. Then, a suitable method was devised to prevent rising damp and to assist in drying out the building. Several measurements after the application of remediation interventions were used for this purpose. The interventions, together with a comprehensive restoration, were intended to contribute to the reuse of the building, and thus its sustainability from technical, environmental, functional, and economic points of view. The aim of this research was to demonstrate the degree of effectiveness of undercutting technology in combination with local application of stainless-steel sheet piling and grouting technology, as one example of sustainability, which is a very relevant topic at the moment. These technologies were intended to provide remediation of the building against rising damp which was destructive to the structure. The environment in this building was affected by moisture and was also unhealthy, which made it difficult to use the building. For these reasons, it was necessary to take radical steps, by applying invasive anti-moisture technologies. The appropriateness and effectiveness of the technologies used have been evidenced by the results published in this article that have also been supplemented by photographs before and after the application of the remediation measures. This research demonstrates the effectiveness of the interventions and the need to also implement them on certain selected buildings where there is a high level of dampness causing degradation. From a sustainability point of view, such a step is essential to preserve the life of such structures and their continued use. The results of this research clearly demonstrate the appropriateness of comprehensive restoration of selected historical buildings, complemented by invasive damp-proofing interventions, as one of the important aspects of the sustainability of deteriorating monuments, whose numbers are constantly increasing.
- 18 July 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (14) , 11187
Open AccessImplementing the Technologies of Additional Impermeable Layers in a Building of the Monuments Office (Káčerov Majer) from a Sustainability Point of View
This article presents the results of an experiment that involved applying additional impermeable layers on an historical building in the area of Káčerov Majer. The building showed a high level of waterlogging, which was detected by an initial inspection and subsequent moisture measurements that involved taking a set of measurements and recording the data in a spreadsheet linked to the plan view of the building. Then, a suitable method was devised to prevent rising damp and to assist in drying out the building. Several measurements after the application of remediation interventions were used for this purpose. The interventions, together with a comprehensive restoration, were intended to contribute to the reuse of the building, and thus its sustainability from technical, environmental, functional, and economic points of view. The aim of this research was to demonstrate the degree of effectiveness of undercutting technology in combination with local application of stainless-steel sheet piling and grouting technology, as one example of sustainability, which is a very relevant topic at the moment. These technologies were intended to provide remediation of the building against rising damp which was destructive to the structure. The environment in this building was affected by moisture and was also unhealthy, which made it difficult to use the building. For these reasons, it was necessary to take radical steps, by applying invasive anti-moisture technologies. The appropriateness and effectiveness of the technologies used have been evidenced by the results published in this article that have also been supplemented by photographs before and after the application of the remediation measures. This research demonstrates the effectiveness of the interventions and the need to also implement them on certain selected buildings where there is a high level of dampness causing degradation. From a sustainability point of view, such a step is essential to preserve the life of such structures and their continued use. The results of this research clearly demonstrate the appropriateness of comprehensive restoration of selected historical buildings, complemented by invasive damp-proofing interventions, as one of the important aspects of the sustainability of deteriorating monuments, whose numbers are constantly increasing.
- Open Access
Contribution to Active Thermal Protection Research—Part 2 Verification by Experimental Measurement
This article is closely related to the oldest article titled Contribution to Active Thermal Protection Research—Part 1 Analysis of Energy Functions by Parametric Study. It is a continuation of research that focuses on verifying the energy potential and functions of so-called active thermal protection (ATP). As mentioned in the first part, the amount of thermal energy consumed for heating buildings is one of the main parameters that determine their future design, especially the technical equipment. The issue of reducing the consumption of this energy is implemented in various ways, such as passive thermal protection, i.e., by increasing the thermal insulation parameters of the individual materials of the building envelope or by optimizing the operation of the technical equipment of the buildings. On the other hand, there are also methods of active thermal protection that aim to reduce heat leakage through nontransparent parts of the building envelope. This methodology is based on the validation of the results of a parametric study of the dynamic thermal resistance (DTR) and the heat fluxes to the interior and exterior from the ATP for the investigated envelope of the experimental house EB2020 made of aerated concrete blocks, presented in the article “Contribution to the research on active thermal protection—Part 1, Analysis of energy functions by the parametric study”, by long-term experimental measurements. The novelty of the research lies in the involvement of variant-peak heat/cooling sources in combination with RES and in creating a new, original way of operating energy systems with the possibility of changing and combining the operating modes of the ATP. We have verified the operation of the experimental house in the energy functions of thermal barrier, heating/cooling with RES, and without RES and ATP. The energy saving when using RES and ATP is approximately 37%. Based on the synthesis and induction of analogous forms of the results of previous research into recommendations for the development of building envelopes with energy-active elements, we present further possible outcomes in the field of ATP, as well as already realized and upcoming prototypes of thermal insulation panels.
Open AccessContribution to Active Thermal Protection Research—Part 2 Verification by Experimental Measurement
This article is closely related to the oldest article titled Contribution to Active Thermal Protection Research—Part 1 Analysis of Energy Functions by Parametric Study. It is a continuation of research that focuses on verifying the energy potential and functions of so-called active thermal protection (ATP). As mentioned in the first part, the amount of thermal energy consumed for heating buildings is one of the main parameters that determine their future design, especially the technical equipment. The issue of reducing the consumption of this energy is implemented in various ways, such as passive thermal protection, i.e., by increasing the thermal insulation parameters of the individual materials of the building envelope or by optimizing the operation of the technical equipment of the buildings. On the other hand, there are also methods of active thermal protection that aim to reduce heat leakage through nontransparent parts of the building envelope. This methodology is based on the validation of the results of a parametric study of the dynamic thermal resistance (DTR) and the heat fluxes to the interior and exterior from the ATP for the investigated envelope of the experimental house EB2020 made of aerated concrete blocks, presented in the article “Contribution to the research on active thermal protection—Part 1, Analysis of energy functions by the parametric study”, by long-term experimental measurements. The novelty of the research lies in the involvement of variant-peak heat/cooling sources in combination with RES and in creating a new, original way of operating energy systems with the possibility of changing and combining the operating modes of the ATP. We have verified the operation of the experimental house in the energy functions of thermal barrier, heating/cooling with RES, and without RES and ATP. The energy saving when using RES and ATP is approximately 37%. Based on the synthesis and induction of analogous forms of the results of previous research into recommendations for the development of building envelopes with energy-active elements, we present further possible outcomes in the field of ATP, as well as already realized and upcoming prototypes of thermal insulation panels.
- Open Access
Contribution to Active Thermal Protection Research—Part 1 Analysis of Energy Functions by Parametric Study
The thermal energy consumption for heating objects is one of the main parameters deciding their technical and structural solution. Reducing energy consumption is realized in various ways. The most used method is passive thermal protection, that is, increasing the thermal insulation parameters of the envelope constructions and optimizing the operation of the technical equipment of the buildings. There are also methods of active thermal protection to reduce heat leakage through non-transparent parts of the building envelope. Active thermal protection (ATP) is a dynamic process that applies primarily to building structures with integrated energetically active elements that fulfill one or more functions in mutually exclusive operating modes of energy systems and heat sources, such as thermal barriers (TB), large-scale heating/cooling, long-term heat/cool storage, capturing solar energy, and energy from the surroundings or even recovering heat in the cold season or cold in the warm season and other combinations. The research area focuses on analyzing active thermal protection’s energy potential. The methodology is based on a parametric study of dynamic thermal resistance (DTR), and heat flows to the interior and exterior from ATP for the investigated envelope of the experimental house EB2020 made of aerated concrete blocks. Such constructions generally show a consistently high DTR of 11.8 to 30.8 ((m2·K)/W) at a low mean heat transfer temperature of 10 to 16 °C, corresponding to the thermal insulation of 300 to 1000 mm. In the case of ATP storage heating with an average temperature of the heat-carrying substance of 30 °C, the heat flow into the interior of the investigated structure would be only 2.31 W/m2. Therefore, they are only suitable for a thermal barrier and heat/cold accumulation. Based on the synthesis and induction of analogical forms of the results of previous research into recommendations for the design of individual energy functions of ATP for perimeter structures of buildings, we present heat flows to the interior/exterior when changing the material of the layers towards the interior from ATP and describe possible variants of the development of building structures with integrated energetically active elements.
Open AccessContribution to Active Thermal Protection Research—Part 1 Analysis of Energy Functions by Parametric Study
The thermal energy consumption for heating objects is one of the main parameters deciding their technical and structural solution. Reducing energy consumption is realized in various ways. The most used method is passive thermal protection, that is, increasing the thermal insulation parameters of the envelope constructions and optimizing the operation of the technical equipment of the buildings. There are also methods of active thermal protection to reduce heat leakage through non-transparent parts of the building envelope. Active thermal protection (ATP) is a dynamic process that applies primarily to building structures with integrated energetically active elements that fulfill one or more functions in mutually exclusive operating modes of energy systems and heat sources, such as thermal barriers (TB), large-scale heating/cooling, long-term heat/cool storage, capturing solar energy, and energy from the surroundings or even recovering heat in the cold season or cold in the warm season and other combinations. The research area focuses on analyzing active thermal protection’s energy potential. The methodology is based on a parametric study of dynamic thermal resistance (DTR), and heat flows to the interior and exterior from ATP for the investigated envelope of the experimental house EB2020 made of aerated concrete blocks. Such constructions generally show a consistently high DTR of 11.8 to 30.8 ((m2·K)/W) at a low mean heat transfer temperature of 10 to 16 °C, corresponding to the thermal insulation of 300 to 1000 mm. In the case of ATP storage heating with an average temperature of the heat-carrying substance of 30 °C, the heat flow into the interior of the investigated structure would be only 2.31 W/m2. Therefore, they are only suitable for a thermal barrier and heat/cold accumulation. Based on the synthesis and induction of analogical forms of the results of previous research into recommendations for the design of individual energy functions of ATP for perimeter structures of buildings, we present heat flows to the interior/exterior when changing the material of the layers towards the interior from ATP and describe possible variants of the development of building structures with integrated energetically active elements.
- Open Access
Analysis of the Dynamic Thermal Barrier in Building Envelopes
This article focuses on the investigation of the dynamic thermal barrier (TB) and dynamic thermal resistance (DTR) of the building envelope. The aim is to analyze the DTR as a function of the temperature change of the heat transfer medium supplied to the dynamic TB layer and to determine the energy potential of several materially different fragments of the building envelope. The functions of TB and DTR depend on the uniform and continuous maintenance of temperature in a given layer of the building structure. The methodology is based on the analysis and synthesis of thermal resistance calculation, wall heating, and computer simulation. The research results show that the relatively low mean temperature of the heat transfer medium of approximately θm = 17 °C delivered to the TB layer represents RDTR = up to 30 ((m2·K)/W) for an equivalent dynamic thermal insulation thickness of 1000 mm for a required standard resistance of RSTANDARD = 6.50 ((m2·K)/W) of the individual fragments analyzed with static thermal insulation of 65 to 210 mm. The energy potential of a thermal barrier (TB) represents an increase of approximately 500% in the thermal resistance and up to 1500% in the thickness of the dynamic thermal insulation. Further research on the dynamic thermal barrier and verification of the results of the parametric study will continue with comprehensive computer simulations and experimental measurements on the test cell.
Open AccessAnalysis of the Dynamic Thermal Barrier in Building Envelopes
This article focuses on the investigation of the dynamic thermal barrier (TB) and dynamic thermal resistance (DTR) of the building envelope. The aim is to analyze the DTR as a function of the temperature change of the heat transfer medium supplied to the dynamic TB layer and to determine the energy potential of several materially different fragments of the building envelope. The functions of TB and DTR depend on the uniform and continuous maintenance of temperature in a given layer of the building structure. The methodology is based on the analysis and synthesis of thermal resistance calculation, wall heating, and computer simulation. The research results show that the relatively low mean temperature of the heat transfer medium of approximately θm = 17 °C delivered to the TB layer represents RDTR = up to 30 ((m2·K)/W) for an equivalent dynamic thermal insulation thickness of 1000 mm for a required standard resistance of RSTANDARD = 6.50 ((m2·K)/W) of the individual fragments analyzed with static thermal insulation of 65 to 210 mm. The energy potential of a thermal barrier (TB) represents an increase of approximately 500% in the thermal resistance and up to 1500% in the thickness of the dynamic thermal insulation. Further research on the dynamic thermal barrier and verification of the results of the parametric study will continue with comprehensive computer simulations and experimental measurements on the test cell.