ZSZuzana Straková

Zuzana Straková

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zuzana Straková has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analysis, evaluation, and optimisation of the operation of the mechanical ventilation of apartment buildings in terms of energy consumption, economic efficiency, and environmental safety

    by Zuzana Straková, Júlia Marková, Daniel Kalús, Tomáš Strenk, Karolína Gábrišová, Lukáš Michalák, Mária Füri, Martina Mudrá

    In this thesis, we present alternative ventilation solutions with heat recovery to reduce energy consumption in apartment buildings: decentralised ventilation compared to local ventilation. The aim is to analyse, evaluate, and optimise the operation of mechanical ventilation. The parametric study of energy, economic, and environmental calculations focuses first on a single apartment and then on the entire apartment building. Local heat recovery units have been designed for the ventilation of the apartment building. The share of heat loss through ventilation is 45% of the total design heat output for heating the building. Considering the UN Sustainable Development Goals, particularly Goal 7 (affordable and clean energy), we evaluated an alternative using decentralised heat recovery units with enthalpy heat exchangers. This approach achieved significant thermal energy savings, covered heat losses due to ventilation, and provided improved air and environmental quality in the apartment building. In this case, the share of ventilation heat losses in the apartment building is only 13% of the total design heat output of the building. The total heat output of the heat source was reduced by almost 78.78 kW, and the energy savings of the decentralised units amounted to 151.30 MWh, a reduction of 44% compared to the local ventilation units. Although the initial investment cost is about 45% higher than for the local units, the return on investment is achieved within 6 years of operation. The proposed solution represents a 58% saving in primary energy for ventilation and an 81% reduction in CO 2 emissions.


  • Open Access

    Energy Sustainability, Resilience, and Climate Adaptability of Modular and Panelized Buildings with a Lightweight Envelope Integrating Active Thermal Protection: Part 2—Design and Implementation of an Experimental Prototype of a Building Module for Modular Buildings

    by Daniel Kalús, Veronika Mučková, Zuzana Straková, Rastislav Ingeli, Naďa Antošová, Patrik Šťastný, Marek Ďubek, Mária Füri, Martin Bolček

    The integration of energy-active elements into the building envelope in the form of large-area heating/cooling, active thermal protection (ATP), thermal barriers (TB), and TABS represents a technical solution that is consistent with the principles of energy sustainability, resilience, and adaptability to climate change and ensures affordable and clean energy for all while protecting the climate in the context of the UN Sustainable Development Goals. The aim and innovation of our research is to develop energy multifunctional facades (EMFs) that are capable of performing a dual role, which includes the primary known energy functions of end elements and the additional innovative ability to serve as a source of heat/cooling/electricity. This new function of EMFs will facilitate heat dissipation from overheated facade surfaces, preheating of hot water, and electricity generation for the operation of building energy systems through integrated photovoltaic components. The theoretical assumptions and hypotheses presented in our previous research work must be verified by experimental measurements with predictions of the optimal operation of building energy systems. Most existing studies on thermal barriers are based on calculations. However, there are few empirical measurements that quantify the benefits of ATP in real operation and specify the conditions under which different types of ATP are feasible. In this article, we present the development, design, and implementation of an experimental prototype of a prefabricated building module with integrated energy-active elements. The aim is to fill the knowledge gaps by providing a comprehensive framework that includes the development, research, design, and implementation of combined energy systems for buildings. The design of energy systems will be developed in BIM. An important result of this research is the development of a technological process for the implementation of a contact insulation system with integrated ATP in modular and panel buildings with a lightweight envelope.


  • Open Access

    Energy Sustainability, Resilience, and Climate Adaptability of Modular and Panelized Buildings with a Lightweight Envelope Integrating Active Thermal Protection. Part 1—Parametric Study and Computer Simulation

    by Veronika Mučková, Daniel Kalús, Simon Muhič, Zuzana Straková, Martina Mudrá, Anna Predajnianska, Mária Füri, Martin Bolček

    Modular and prefabricated buildings are advantageous in terms of construction, transport, energy efficiency, fixed costs, and the use of environmentally friendly materials. Our research aims to analyze, evaluate, and optimize a lightweight perimeter structure with an integrated active thermal protection (ATP). We have developed a mathematical–physical model of a wall fragment, in which we have analyzed several variants through a parametric study. ATP in the energy function of a thermal barrier (TB) represents a high potential for energy savings. Cold tap water (an average temperature of +6 °C, thermal untreated) in the ATP layer of the investigated building structure increases its thermal resistance by up to 27.24%. The TB’s mean temperature can be thermally adjusted to a level comparable to the heated space (e.g., +20 °C). For the fragment under consideration, optimizing the axial distance between the pipes (in the ATP layer) and the insulation thickness (using computer simulation) reveals that a pipe distance of 150 mm and an insulation thickness of 100 mm are the most suitable. ATP has significant potential in the design of sustainable, resilient, and climate-adaptive buildings, thereby meeting the UN SDGs, in particular the Sustainable Development Goal 7 ‘Affordable and Clean Energy’ and the Goal 13 ‘Climate Action’.


  • Open Access

    Heat Recovery Variable Refrigerant Volume System Installation and Experiences from its Summer Operation

    by Zuzana Straková, Jozef Vojtaššák, Ján Takács, Mária Kurčová, Pavol Štefanič, Samuel Malíšek

    Variable refrigerant volume (VRV) systems operate on the principle of a cooling machine. They extract heat from one side and return it on the other, enabling them to function as a source of heat for both heating and hot water preparation, as well as a source of cold for cooling within a single building. These systems efficiently remove unnecessary excess heat outside and only introduce the required amount of heat from the outside into the building. With an appropriate configuration and setting, a VRV system can transfer heat in both directions within one system, eliminating the requirement for waste heat to be removed without use in the building. Instead, it is transferred to the desired locations where it is needed. This principle necessitates the adjustment of not only the refrigerant temperature but also its flow rate. Consequently, the VRV system can fulfil tasks that are otherwise handled by several individual systems in a building. A heat recovery VRV system was installed in a small retail store to extract waste heat generated by baking ovens during the baking process. This report provides a brief summary of electricity and energy consumption measurements taken during the summer period for cooling purposes. Sequential logic is observed and coherence is ensured, with active voice predominating for clearer and more direct communication. The parameters of interest include cooling setpoints, cooling outside of working hours, and capacity assessment.

  • Open Access

    Contribution to Active Thermal Protection Research—Part 2 Verification by Experimental Measurement

    by Daniel Kalús, Veronika Mučková, Daniela Koudelková, Mária Kurčová, Zuzana Straková, Martin Sokol, Rastislav Ingeli, Patrik Šťastný, Peter Janík

    This article is closely related to the oldest article titled Contribution to Active Thermal Protection Research—Part 1 Analysis of Energy Functions by Parametric Study. It is a continuation of research that focuses on verifying the energy potential and functions of so-called active thermal protection (ATP). As mentioned in the first part, the amount of thermal energy consumed for heating buildings is one of the main parameters that determine their future design, especially the technical equipment. The issue of reducing the consumption of this energy is implemented in various ways, such as passive thermal protection, i.e., by increasing the thermal insulation parameters of the individual materials of the building envelope or by optimizing the operation of the technical equipment of the buildings. On the other hand, there are also methods of active thermal protection that aim to reduce heat leakage through nontransparent parts of the building envelope. This methodology is based on the validation of the results of a parametric study of the dynamic thermal resistance (DTR) and the heat fluxes to the interior and exterior from the ATP for the investigated envelope of the experimental house EB2020 made of aerated concrete blocks, presented in the article “Contribution to the research on active thermal protection—Part 1, Analysis of energy functions by the parametric study”, by long-term experimental measurements. The novelty of the research lies in the involvement of variant-peak heat/cooling sources in combination with RES and in creating a new, original way of operating energy systems with the possibility of changing and combining the operating modes of the ATP. We have verified the operation of the experimental house in the energy functions of thermal barrier, heating/cooling with RES, and without RES and ATP. The energy saving when using RES and ATP is approximately 37%. Based on the synthesis and induction of analogous forms of the results of previous research into recommendations for the development of building envelopes with energy-active elements, we present further possible outcomes in the field of ATP, as well as already realized and upcoming prototypes of thermal insulation panels.


  • Open Access

    Contribution to Active Thermal Protection Research—Part 1 Analysis of Energy Functions by Parametric Study

    by Veronika Mučková, Daniel Kalús, Daniela Koudelková, Mária Kurčová, Zuzana Straková, Martin Sokol, Rastislav Ingeli, Patrik Šťastný, Peter Janík

    The thermal energy consumption for heating objects is one of the main parameters deciding their technical and structural solution. Reducing energy consumption is realized in various ways. The most used method is passive thermal protection, that is, increasing the thermal insulation parameters of the envelope constructions and optimizing the operation of the technical equipment of the buildings. There are also methods of active thermal protection to reduce heat leakage through non-transparent parts of the building envelope. Active thermal protection (ATP) is a dynamic process that applies primarily to building structures with integrated energetically active elements that fulfill one or more functions in mutually exclusive operating modes of energy systems and heat sources, such as thermal barriers (TB), large-scale heating/cooling, long-term heat/cool storage, capturing solar energy, and energy from the surroundings or even recovering heat in the cold season or cold in the warm season and other combinations. The research area focuses on analyzing active thermal protection’s energy potential. The methodology is based on a parametric study of dynamic thermal resistance (DTR), and heat flows to the interior and exterior from ATP for the investigated envelope of the experimental house EB2020 made of aerated concrete blocks. Such constructions generally show a consistently high DTR of 11.8 to 30.8 ((m2·K)/W) at a low mean heat transfer temperature of 10 to 16 °C, corresponding to the thermal insulation of 300 to 1000 mm. In the case of ATP storage heating with an average temperature of the heat-carrying substance of 30 °C, the heat flow into the interior of the investigated structure would be only 2.31 W/m2. Therefore, they are only suitable for a thermal barrier and heat/cold accumulation. Based on the synthesis and induction of analogical forms of the results of previous research into recommendations for the design of individual energy functions of ATP for perimeter structures of buildings, we present heat flows to the interior/exterior when changing the material of the layers towards the interior from ATP and describe possible variants of the development of building structures with integrated energetically active elements.


  • Open Access

    Analysis of the Dynamic Thermal Barrier in Building Envelopes

    by Veronika Mučková, Daniel Kalús, Daniela Koudelková, Mária Kurčová, Zuzana Straková, Martin Sokol, Rastislav Ingeli, Patrik Šťastný

    This article focuses on the investigation of the dynamic thermal barrier (TB) and dynamic thermal resistance (DTR) of the building envelope. The aim is to analyze the DTR as a function of the temperature change of the heat transfer medium supplied to the dynamic TB layer and to determine the energy potential of several materially different fragments of the building envelope. The functions of TB and DTR depend on the uniform and continuous maintenance of temperature in a given layer of the building structure. The methodology is based on the analysis and synthesis of thermal resistance calculation, wall heating, and computer simulation. The research results show that the relatively low mean temperature of the heat transfer medium of approximately θm = 17 °C delivered to the TB layer represents RDTR = up to 30 ((m2·K)/W) for an equivalent dynamic thermal insulation thickness of 1000 mm for a required standard resistance of RSTANDARD = 6.50 ((m2·K)/W) of the individual fragments analyzed with static thermal insulation of 65 to 210 mm. The energy potential of a thermal barrier (TB) represents an increase of approximately 500% in the thermal resistance and up to 1500% in the thickness of the dynamic thermal insulation. Further research on the dynamic thermal barrier and verification of the results of the parametric study will continue with comprehensive computer simulations and experimental measurements on the test cell.


  • Open Access

    A New Perspective on Residential Building Ventilation from the Point of View of Achieving the Desired Indoor Air Quality using Different Ventilation Systems

    by Zuzana Straková, Júlia Marková

    The case study analyses a specifically described situation from the present and a summary of events from the past, finds alternative solutions, and decides on one of them. The target of such a detailed analysis was a concrete apartment building, which was still in the project phase; the efforts to change its proposed air conditioning system to a more energy-efficient one are the subject of the case study. Apartment buildings with modern technology installed in terms of sanitary equipment, heating, and simple methods of ventilation and cooling do not constitute part of the project. Through a detailed analysis of the calculation of the heat losses through ventilation in the case of local and decentralised ventilation applied to one apartment unit, this failure to address modern solutions is remedied.


  • Parametric Study of Heating and Cooling Capacity of Interior Thermally Active Panels

    by Daniel Kalús, Zuzana Straková, Matej Kubica

    ITAP panels - interior thermally active panels with an integrated active surface in an innovative way combine existing building and energy systems into one compact unit, and thus create combined building and energy systems. These are building structures with an internal energy source. Low heat losses, respectively, thermal gains predestine for energy-efficient buildings the application of lowtemperature heating/high-temperature cooling systems such as large-area floor, wall, and ceiling heating/cooling. The main benefit of ITAP panels is the possibility of unified and prefabricated production. At the same time, they represent a reduction of production costs due to their technological process of production, a reduction of assembly costs due to a reduction of steps during implementation on the construction site and a reduction of implementation time due to their method of application.